AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

Similar documents
0ACDT2000MV Ultasonic/Infared Occ Sensor

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Arrow Hart hospital grade self-test GFCI receptacles

Residential Occupancy & Vacancy Sensors

Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

AF/GF dual-purpose receptacles

Arrow Hart specification grade GFCI receptacles

Gfci Self Test Duplex 20A 125V WH

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Aspire LED, CFL & Incandescent Dimmer

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Toggle AL series dimmer

Slide AL series dimmer

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Smart AL series dimmers

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Tamper & Weather Resistant Receptacles

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

Toggle AL series dimmer

Supporting the Requirements of EPAct 2005 Tax Deductions

Installation Instructions

Decorator AL series dimmer

Aspire smart AL dimmer

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Wherever the best is needed. Sensors for professionals.

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

SAL06PBK 300/600W 120V Dimmer. Features. Dimensions and Weight. Long Description

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

A. This Section includes the following lighting control devices:

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper

180 Degree Ceiling Mounted Occupancy Sensors

Smart AL series dimmers

Versatile wall switch sensors maximize payback and simplify code compliance

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Never forget to turn the lights off again. Motion Sensors

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

Ever evolving energy code requirements and the large demand for energy

Sensors and Detectors

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Installation Instructions

Maestro 0 10 V Dimmer Sensor

IN2 Lighting Control Devices

ENERGY EFFICIENCY EXPERTS

A. This Section includes the following lighting control devices:

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

WaveLinx Wireless Connected System

Infrared Ceiling Mount Sensor

Wireless Plug Load Control

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

H-MOSS Occupancy Sensors Control Units and Add-A-Relay

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

RTC Recessed LED center basket

STANDARD FEATURES SPECIFICATIONS

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

Infrared Wall Mount Occupancy Sensor

Mini Product Guide.

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

Installation Instructions

CONTENTS SENSOR SWITCH

Infrared Ceiling Mount Sensor

Accessories. Desk Top Controls

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

LIGHTING CONTROL DEVICES

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

SECTION LIGHTING CONTROL DEVICES

Sensors Explained AUTOMATION

SECTION. Occupancy Sensors & Lighting Control Products

ArcLine Recessed LED luminaire

Applied Lighting Controls

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

Sensor Product Guide. Smart Sensing Control Solutions

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

SAFEPATH Mass Notification System (SPMNS)

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Installation Instructions

Lighting Control Strategies. to meet code requirements save energy and improve building performance

RLN Recessed LED luminaire

APPENDIX E LIGHTING CONTROL DATA

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

National Grid Small Business Program Rebate Manual

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Honeywell ENERGY SAVINGS KIT

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

GE LightSweep Lighting Control System Guideform Specification

Connected Buildings Sales positioning guide

Transcription:

s Ceiling sensors description The dual technology sensor s combination of ultrasonic and passive infrared technologies offers the most complete sensing equipment available today. MicroSet self-adjusting dual technology sensors drastically simplify and reduce a contractor s installation and adjustment time period. Design features MicroSet self-adjusting time delay and sensitivity Products tested to NEMA WD 7-211 Occupancy Motion Sensors Standard Built-in light level sensor (Low voltage only) BAS/HVAC isolated relay (Low voltage only) Selectable walk-through mode (Low voltage only) Dual relay control (Low voltage only) Units available for control of single or two separate loads ( voltage only) AHAC-DT Table 1. MicroSet dual tech - line voltage ceiling sensor Field of view Frequency Features AHAC-DT-2-MV 2 sq. ft. Two way (36 ) 32 khz With daylight sensor AHAC-DT-2-DMV 2 sq. ft. Two way (36 ) 32 khz Dual relay with daylight sensor AHAC-STEM - Table 2. MicroSet dual tech - low voltage ceiling sensor Field of view Frequency Features AHAC-DT-2 2 sq. ft. Two way (36 ) 32 khz - AHAC-DT-1 1 sq. ft. Two way (36 ) 32 khz AHAC-DT-51 5 sq. ft One way (18 ) 4 khz AHAC-STEM - AHSP2-MV Table 3. Heavy duty switchpack Description Features AHSP2-MV* Heavy duty switchpack Capable of switching up to 2A * For more information about switchpack visit our website at www.eaton.com/wiringdevices

Applications The MicroSet self-adjusting technology continuously monitors multiple sub-frequencies in the event that if a continuous Doppler shift occurs, such as those created by airflow from an air duct, the sensor will identify the noise as continuous and then block it out of view at a select sub-frequency. It will continue to monitor other sub-frequencies for human motion. This avoids false-activation, while still maintaining the high level of sensitivity that is necessary for sensing minor motion in a changing environment. Separate concurrent time delays for both Passive Infrared and Ultrasonic technologies avoid false activations or deactivations. In Automatic ON Mode, the lights turn ON when a person enters the room. Table 4. Specifications Table 5. Specifications Technology Power Requirements Time Delays Light Level Sensing Operating Environment Housing Size Mounting LED Indicators Standards AHAC-DT - low voltage series Passive Infrared (PIR) and Ultrasonic (US) Input 1-3 VDC from Greengate Switchpack or Greengate system Maximum current needed is 25mA per sensor Output Open collector output to switch up to ten Greengate Switchpacks Isolated Form C Relay Ratings: 1A 3 VDC/V/AC Self-adjustable, 15 seconds/test (1 minutes Auto), or Selectable 5, 15, 3 minutes, or Zero Time Delay 5, 1, and 2 sq. ft. to 3 foot-candles Temperature: 32 F - 14 F ( C - 4 C) Relative humidity: 2% to 9%, non-condensing (For indoor use only) Durable, injection molded housing. Polycarbonate resin complies with UL 94V- 1.42 H x 4.5 W (36.68mm x 114.3mm) Mounts directly to ceiling tile, to a 4 square box and round mud ring or to 4 octagon box Red LED for PIR detection; Green LED for Ultrasonic detection FCC Compliant culus Listed RoHS Compliant Technology Power Requirements Time Delays Light Level Sensing Operating Environment Housing Size Mounting LED Indicators Standards AHAC-DT - line voltage series Passive Infrared (PIR) and Ultrasonic (US) 12 to 347 V/AC, 5/6 Hz - required 12 V/AC Incandescent/Tungsten - to 8W, 5/6 Hz Fluorescent/Ballast - to 12W, 5/6 Hz Motor Load: 1/4 HP @ 125 V/AC 23 V/AC Fluorescent/Ballast - to 12W, 5/6 Hz 277 V/AC Fluorescent/Ballast - to 27W, 5/6 Hz 347 V/AC Fluorescent/Ballast - to 15W, 5/6 Hz Self-Adjusting, 15 seconds/test (1 minutes Auto), or Selectable 5, 15, 3 minutes 2 sq. ft to 3 foot-candles Temperature: 32 F - 14 F ( C - 4 C) Relative humidity: 2% to 9%, non-condensing (For indoor use only) Durable, injection molded housing. Polycarbonate resin complies with UL 94V- 1.42 H x 4.5 W (36.68mm x 114.3mm) Mounts directly to ceiling tile, to a 4 square box and round mud ring or to 4 octagon box Red LED for PIR detection; Green LED for Ultrasonic detection FCC Compliant culus Listed RoHS Compliant Table 6. Color information W () W 2 EATON www.eaton.com/wiringdevices

Wiring diagrams Hot **Use black lead for 12 VAC Use orange lead for 277 VAC Cap unused lead. **Hot Load A Manual Mode Operation: 1. Switches are required to turn corresponding loads ON. times out or with the switches. 3. If daylight sensor is enabled and light level is above setpoint, switchpack connected to yellow lead will not turn load ON 1. When sensor activates, both loads turn on. 2. Switches can be used to turn lights ON or OFF. 3. If daylight sensor is enabled and light level is above setpoint, switchpack connected to yellow lead will not turn ON. Recommended Wire: 18-3 AWG Stranded Wire non/shielded. Purple (Normally Closed) Gray (Isolated Relay Common) Orange (Normally Closed) Red (1-3 VDC) (Control-OCC) Yellow (Control-Occ/Day) Brown ( Control) Brown/ (Yellow Control) Red (15 VDC) (Control) Model GMDS - Load B (Normally Open Momentary Switch) SWITCH- PACK **Use black lead for 12 VAC Use orange lead for 277 VAC Cap unused lead. Red (15 VDC) (Control) Hot SWITCH- PACK **Hot Load B *Wiring diagram for single sensor application. Visit our website for other wiring diagrams. Model GMDS - Load A (Normally Open Momentary Switch) NOTES 1. LOADS MAY BE ON SAME CIRCUIT OR DIFFERENT CIRCUIT OR VOLTAGES 2. SP2-MV SWITCHPACK SHOWN. 12/277 VAC 2AMP RATING. Figure 1. AHAC-DT-2 Model 1. When sensor activates, load turns ON times out 12-347 V/AC 1. When sensor activates, both loads turn ON times out 12-347 V/AC Black Load 1 Black Red Red Load 1 Load 2 Red leads are non-polorarity sensitive. Figure 2. Single relay - line voltage series Figure 3. Dual relay - line voltage series EATON www.eaton.com/wiringdevices 3

16 ft (4.87 m) DT1k Minor Major Minor Major 1 ft 1 (3.5 m) (4.57 m) (7.1 m) 3 ft (.91) (7.1 m) 17 ft 1 1 ft (5.18 m) (4.57 m) (3 m) (1.5 m) (1.5 m) 1 ft 1 17 ft (3 m) (4.57 m) (5.18 m) (7.1 m) 16 ft (4.87 m) 3 ft (.91) 32 ft (9.75 m) 1 (7.1 m) (4.57 m) 1 ft (3 m) 1 ft 1 (3 m) (4.57 m) (7.1 m) 32 ft (9.75 m) Major Motion, Minor IRMotion, Ultrasonic vary somewhat Maximum according coverage to room area may shape and vary the presence somewhat of obstacles. according to room The shape NEMA WD and 7 Guide the and presence robotic of obstacles. vary somewhat according to room shape Maximum and the presence coverage of obstacles. area may vary The somewhat NEMA WD 7 Guide according and robotic to room shape and coverage the presence patterns. of obstacles. vary somewhat according to room shape and the presence of obstacles. AHAC-DT-51 5 sq. ft. AHAC-DT-1 1 sq. ft. AHAC-DT-2/MV/DMV 2 sq. ft. Controls (Low voltage) LEDs Override Sweep Full/Half Logic HVAC/Tracking Zero Time Delay Normal Swap Daylight Sensor Adjustment Ultrasonic Sensitivity Adjustment ON PIR Detector 1 2 3 4 5 6 7 8 9 1 11 12 Controls ( voltage) Not Used LEDs Override Not Used Daylighting Bathroom Mode Relay Swap Relay 2 Relay 1 & 2 (DMV model only) (DMV model only) (DMV model only) Daylight Sensor Adjustment Ultrasonic Sensitivity Adjustment ON PIR Detector 1 2 3 4 5 6 7 8 9 1 11 12 4 EATON www.eaton.com/wiringdevices

Certifications & compliances AHAC-DT-2 AHAC-DT-1 AHAC-DT-51 AHAC-DT-2-MV AHAC-DT-2-DMV AHAC-STEM KEY: culus RoHS 23 Cooper Circle Peachtree City, GA 3269 United States Eaton.com Canada Operations 5925 McLaughlin Road Mississauga, Ontario, L5R 1B8 Canada EatonCanada.ca Mexico Operations Carr. Tlalnepantla - Cuautitlan Km 17.8 s/n Col. Villa Jardin esq. Cerrada 8 de Mayo Cuautitlan, Mexico CP 548 Mexico Eaton.mx Eaton 1 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 218 Eaton All Rights Reserved Printed in USA Publication No. TD6242EN (REV 1) September 218 Eaton is a registered trademark. All other trademarks are property of their respective owners.