CVS Model Inline Multi-Port Ventilators

Similar documents
DBF 4XL Dryer Booster Fans

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

e Bath Fan with Light User s Guide

e Heater/Exhaust Fan/Light User s Guide

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Bathroom Exhaust Fan/Fluorescent Light Combination

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

HUMIDITY SENSING BATH FAN

READ AND SAVE THESE INSTRUCTIONS

Easy installation in both new construction and retrofit

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Easy installation in both new construction and retrofit

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Bathroom Exhaust Fan/Fluorescent Light Combination

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

VENTILATION FAN / LED LIGHT

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Bathroom Exhaust Fan

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

MODEL CDB8 INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.


Active Thermal Management. SEC-1 Installation Instructions

OKB, OKD, & OKH Series

SYSTEM CONTROL KIT Model: CK-41P

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

RDF INSTALLATION INSTRUCTIONS

breeze easytm model # F100-1W

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

User s guide RUH series Economical unit heater Replacement component list included

Easy installation. T080LP ENERGY STAR Lo Profile Ventilation Fan INSTALLATION GUIDE

VENTILATION FAN WITH LIGHT AND HEATER

SF180 Installation Instructions

Installation & Maintenance Instructions

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Please Read and Save These Instructions Safety Information

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

RP, GP, XP Pro Series Installation Instructions

MODEL BVS 120 AND 200

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Light commercial models

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

120 VAC SYSTEM CONTROL KIT

120 VAC SYSTEM CONTROL KIT Model: CK-63

Please Read and Save These Instructions.

September 2016 Humidex GVS-H Rev. 2.2En. Owner s Manual. Manufactured by: Clairitech Innovations Inc Ohio Rd. Boudreau-West, NB Canada E4P 6N4

USER S guide. Wall fan heater. This unit complies with the CSA standards. Recommended heating capacity: 1,25 W/cubic foot (0.03 m³).

55-Gallon Dispenser Package

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

Insulated Ventilators. Operating Instructions & Parts Manual

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

VENTILATION FAN WITH BLUETOOTH SPEAKER

20 High velocity Air

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

MaxLite LED High Bay Fixtures

HS Series Installation & Operating Instructions RadonAway

XCHANGER TM MODEL X2D

INSTALLATION INSTRUCTIONS

October 2016 Humidex GVS-SD Rev. 1.2En. Owner s Manual. Manufactured by: Clairitech Innovations Inc Ohio Rd. Boudreau-West, NB Canada E4P 6N4

COMBUSTION AIR SYSTEM

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

MH70230AS MH70236AS MH70248AS

COMBUSTION AIR SYSTEM Model: CAS-3

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

VSA/VSB & KSA/KSB Series Air Doors

Installation and Operating Instructions

(HSTAT Series) Instruction Manual

40E ELECTRIC FAN HEATER

HI Industrial Utility Heater HI Soleus Air International

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

INSTALLATION MANUAL AND USER GUIDE

HS Series Installation & Operating Instructions RadonAway

HotPoly Tote Tank / IBC Heaters (TTH Series)

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

FloorHeat Installation Manual

Instruction Leaflet. Read instructions before operating. Retain for future reference.

INSTALLATION AND OPERATION GUIDE

Transcription:

Installation Manual Item #: 402332 Rev Date: 081613 CVS Model Inline Multi-Port Ventilators United States 10048 Industrial Blvd., Lenexa, KS, 66215 Tel.: 800.747.1762 Fax: 800.487.9915 Canada 50 Kanalflakt Way, Bouctouche, NB, E4S 3M5 Tel.: 800.565.3548 Fax: 877.747.8116

2 Note Warning / Important note Information Technical information Practical tip READ THESE INSTRUCTIONS COMPLETELY BEFORE INSTALLING FAN AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. Before Servicing or Cleaning Unit, Switch Power Off At Service Panel and Lock Service Panel To Prevent Power From Being Switched On Accidentally. Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction. When cutting or drilling into walls or ceilings, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application. NEVER place a switch where it can be reached from a tub or shower. FOR INTERIOR USE ONLY DO NOT USE WITH HEATED AIR IN EXCESS OF 60 C (140 F). CAUTION: For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit s operation. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

Dimensions 3 F D A1 A2 A2 Air flow A1 E E 2 1/ 1 4 / 1/ 4 2 1 / 4 C Model A1 A2 C D E F CVS275A 6 5 11 15 7 3 / 4 12 Dimensional information is in inches A2 FF D A2 Air flow A1 1 3/ 4 E 1 3 / A1 A2 A2 1 3/ 4 3 4 / 4 C Model A1 A2 C D E F CVS300A 6 4 13 18 3 / 4 8 1 / 4 16 CVS400A 6 4 13 18 3 / 4 8 1 / 4 16 Dimensional information is in inches

4 Installation Installing the Mounting Casing and Fan STEP 1. When selecting a fan mounting location, the following criteria should be considered: a) type of application; b) service accessibility; and c) mounting to minimize noise generated by fan operation. a) Intermittent ventilation - i.e. bathroom exhaust, kitchen area exhaust; continuous ventilation for indoor air quality. Important Notice: When using the fan in a continuous system, adequate makeup air should be provided in order to prevent backdrafting of combustion appliances. b) Fan location should allow sufficient access for service. c) Mounting the fan as far as possible from the exhaust point will minimize fan operating noise from being transmitted back through the duct work. If the fan is to be used as a booster for moving the air between two rooms, a central point along the duct may be optimal. Insulated type duct work (recommended for all bathroom exhaust applications) will also result in quieter operation. STEP 2. To fasten the mounting casing to the ceiling, use either threaded rod or wires to suspend the unit from the ceiling. You may also install the unit by fastening it to a frame using either wood or sheet-metal screws depending on the surface to which you chose to attach the unit. The frame should be designed to eliminate vibration. STEP 3. Connect duct work to inlet and outlet of fan using FC clamps or duct tape. When using insulated duct, it is recommended that the inner vinyl core be clamped or taped to the inlet and outlet collar and that the vapor barrier surrounding the insulation be duct taped to the side of the unit. Installing the Supply/Exhaust Grill STEP 1. Select the grill mounting point within the area to be ventilated. To ease installation, locations of framing beams within the walls or joists supporting the ceiling should be considered. STEP 2. Place the mounting collar in the selected location and trace a circle onto the surface. From the interior side of the room, cut through the surface. Please note: in order to assure a smoother finish when mounting through a sheetrock or tile type ceiling, it is recommended that a razor knife be used to make the cut. STEP 3. From within the attic or crawl space, place the ducting into the hole until the edge of the duct is flush with the interior wall or ceiling surface. Attach collar to the duct work and clamp or tape into place, if necessary. If grills are equipped with mounting screws, install them before installing the duct work. STEP 4. Insert grill. Multi-Port Ventilation System Residential Application We recommend the use of flexible duct Vent #1 Duct Vent #2 Fantech CVS Series Fan Louvered Exhaust Outlet Duct Back-draft Damper Grill

Electrical Connections 5 Do not connect power supply until fan is completely installed. Make sure electrical service to the fan is locked in OFF position. STEP 1. Punch out the knockout on the same side as where the female plugin cover is located. Note that it is possible to place the plug-in on the other side of the unit by simply removing the screw securing the cover and installing it on the other side where a pre-drilled hole is provided. Remember to also move the grounding screw to the same side as the female plug. STEP 2. Run the two lead wires through the knockout. Connect the electrical power source (see wiring diagram). Use wire connectors-insulators to join each lead wire to the power source. Fasten the ground wire from the electrical source to the screw provided (indicated by the ground symbol ). If the motor assembly is already installed and plugged into the female plug-in, skip step 3 and 4. STEP 3. Insert the motor assembly into the square hole so that the mounting holes align. Hint: Insert one side of the motor assembly and slide it so that the fan is partially under the motorplate, then insert the other side. Fasten with four (4) sheet metal screws, included. STEP 4. Before starting the unit, turn the fan by hand to assure a free rotation. If it hits the orifice, check the screws holding the motor bracket. Adjustments can be made by loosening the motor bracket screws. STEP 5. Plug in the motor assembly to the female plug-in. STEP 6. Place the cover on top of the unit and fasten with the two (2) sheet metal screws provided.

6 Notes

Warranty 7 Five (5) Year Warranty This warranty supersedes all prior warranties DURING ENTIRE WARRANTY PERIOD: Fantech will repair or replace any part which has a factory defect in workmanship or material. Product may need to be returned to the Fantech factory, together with a copy of the bill of sale and identified with RMA number. FOR FACTORY RETURN YOU MUST: Have a Return Materials Authorization (RMA) number. This may be obtained by calling Fantech either in the USA at 1.800.747.1762 or in CANADA at 1.800.565.3548. Please have bill of sale available. The RMA number must be clearly written on the outside of the carton, or the carton will be refused. All parts and/or product will be repaired/replaced and shipped back to buyer; no credit will be issued. OR The Distributor may place an order for the warranty part and/or product and is invoiced. The Distributor will receive a credit equal to the invoice only after product is returned prepaid and verified to be defective. Fantech WARRANTY TERMS DO NOT PROVIDE FOR REPLACEMENT WITHOUT CHARGE PRIOR TO INSPECTION FOR A DEFECT. REPLACEMENTS ISSUED IN ADVANCE OF DEFECT INSPECTION ARE INVOICED, AND CREDIT IS PENDING INSPECTION OF RETURNED MATERIAL. DEFECTIVE MATERIAL RETURNED BY END USERS SHOULD NOT BE REPLACED BY THE DISTRIBUTOR WITHOUT CHARGE TO THE END USER, AS CREDIT TO DISTRIBUTOR S ACCOUNT WILL BE PENDING INSPECTION AND VERIFICATION OF ACTUAL DEFECT BY Fantech. THE FOLLOWING WARRANTIES DO NOT APPLY: Damages from shipping, either concealed or visible. Claim must be filed with freight company. Damages resulting from improper wiring or installation. Damages or failure caused by acts of God, or resulting from improper consumer procedures, such as: 1. Improper maintenance 2. Misuse, abuse, abnormal use, or accident, and 3. Incorrect electrical voltage or current. Removal or any alteration made on the Fantech label control number or date of manufacture. Any other warranty, expressed, implied or written, and to any consequential or incidental damages, loss or property, revenues, or profit, or costs of removal, installation or reinstallation, for any breach of warranty. WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date. These warranties give you specific legal rights, and are subject to an applicable consumer protection legislation. You may have additional rights which vary from state to state. Limitation of Warranty and Liability This warranty does not apply to any Fantech product or part which has failed as a result of faulty installation or abuse, incorrect electrical connections or alterations made by others, or use under abnormal operating conditions or misapplication of the product or parts. We will not approve for payment any repair not made by us or our authorized agent without prior written consent. The foregoing shall constitute our sole and exclusive warranty and our sole exclusive liability, and is in lieu of any other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the description on the page hereof. In no event, whether as a result of breach of contract, or warranty or alleged negligence, defect incorrect advice or other causes, shall Fantech be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of equipment or any other associated equipment, cost of capital, cost of substitute equipment, facilities or services, downtime costs, or claims of customers of purchase for such damages. Fantech neither assumes or authorizes any person to assume for it any other liability in connection with the sale of product(s) or part(s). Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you. Warning Fantech products are designed and manufactured to provide reliable performance, but they are not guaranteed to be 100% free from defects. Even reliable products will experience occasional failures and this possibility should be recognized by the user. If these products are used in a life support ventilation system where failure could result in loss or injury, the user should provide adequate backup ventilation, supplementary natural ventilation, failure alarm system, or acknowledge willingness to accept the risk of such loss or injury.

Fantech reserves the right to make technical changes. For updated documentation please refer to www..net Fantech