Sensistor ISH2000 Hydrogen Leak Detector

Similar documents
Leak testing in the HVACR Industry

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

AGILENT VS SERIES LEAK DETECTORS

Sensistor XRS9012. Maintenance manual. Hy d r o g e n Leak Det e c t o r

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Dew-Point Transmitters and Instruments

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

T.ex Single Gas Detector VISA

USER MANUAL MINITRACER PORTABLE SNIFFER

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

REFRIGERANT LEAK DETECTOR

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

ELD500 PRECISION LEAK DETECTOR

Using the Model 1500 Portable Chilled Mirror Hygrometer

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

Dräger Pac 8500 Single-Gas Detector

Series 9000 Total Hydrocarbon Analyzer

Improving Productivity, Quality and Security

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Safe Operation Manual. Honeywell IQ Force Gas Detector

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

Dräger Pac 6000 Single-Gas Detector

AIR CONDITIONNING 95 CODE 002

Dräger X-am 7000 Multi-Gas Detection

D-TEK Select. Refrigerant Leak Detector

Datalogging as standard

User Manual for ULTRASCAN High Pressure Leak and Corona Discharge Detector

Refrigerant Leak Detection Solutions

LS1. Operator Manual. Kane International Ltd

Recalibrate the way you look at gas detection

Helium Leak Detection Systems

Whisper. Ultrasonic Leak Detector

ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

LD-5000 REFRIGERANT LEAK DETECTOR

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

intrinsically safe detector for hydrocarbon gases

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Dräger Pac 3500 Single-Gas Detection Device

CO warning instruments and gas spillage detectors

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

Model OEM-2 INSTRUCTIONS FOR USE

H-10PM. Refrigerant Leak Detector

Dräger Pac 6000 Single-Gas Detection Device

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

PHOENIXL 300 New Standards in Leak Testing. Technical information

Dräger Pac 7000 Single-Gas Detection Device

Refrigerant Leak Detector

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Dräger Pac 8500 Single-Gas Detection Device

F-900 Portable Ethylene Analyzer

C A T A L O G

TEK-Mate. Refrigerant Leak Detector

CO2 Incubators The Complete Line

Dräger X-zone 5500 Area Monitoring

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

GAS ANALYSIS / DETECTION Gas Detector

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

incubator, the best in its class

Dräger Pac 5500 Single-Gas Detection Device

NJSP HMRU. Module 5 B HM Operations 1

IT S WHAT S INSIDE THAT

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Portable Holiday Detectors

NEW Restek Electronic Leak Detector

NGD8800 USER S MANUAL

ALTAIR 5X Multigas Detector

Mercury Vapor Monitor VM-3000

Vacuum in the laboratory. products and solutions

Overview SENSING AND CONTROL. Part Innovation. Part Engineering. Total Solutions.

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Safety Laboratory Gas Burner. - A step ahead! Technical Data: The range of delivery:

Leak Detection C A T A L O G

Software-Aided Operation of Modern Industrial Leak Detectors

Dräger Pac 8000 Single-Gas Detection Device

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Are Thermistors the Right Choice for Your Temperature Measurement Application?

Dräger X-am 2500 Multi-Gas Detector

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

RLD-H10P Refrigerant Leak Detector

For the Safety of Your

We measure it. testo 316-Ex CH 4 testo 316-1

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

VM-3000 Mercury Vapor Monitor

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

Dräger X-am 2500 Multi-Gas Detection

WORLD LEADER IN TEST TECHNOLOGY InterTech is a manufacturer of turnkey automated systems with proven technology for leak and functional testing.

TECHNICAL INFORMATION Super Scanner V Metal Detector Catalog No. MDWAND

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

What extinguishes fires without pressure peaks?

Pressure measuring instruments

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Transcription:

Hydrogen Leak Detector IDEAL FOR FINDING BOTH BIG AND SMALL LEAKS

Fast, Simple and Cost Effective Industrial Leak Detection and Leak Testing The is a robust instrument for professional leak detection. The unique method involving the use of inexpensive forming gas (5 % hydrogen and 95 % nitrogen) as tracer gas combines unmatched measuring properties with user-friendly technology, low costs and minimal service requirements. This makes Sensistor ISH2000 the best option for a wide range of production and maintenance applications, especially for finding leaks of a size that would leak liquids such as water, fuel and oils, or in environments with occasional large leaks. With its unique tolerance to high gas concentrations, the is superior in precisely pinpointing leak location, irrespective of leak size. INFICON provides a range of detectors, probes and instruments for tracer gas filling and fixture control that make it quick and simple to build tailor-made stations for leak testing and leak detection. For many applications, you do not even need to make any adjustments it is simply a matter of pressing the start button on the Sensistor ISH2000 to start locating leaks. FLEXIBLE AND VERSATILE FOR EVERY TEST ENVIRONMENT The is a stationary, mains connected instrument for rapid leak detection in a multitude of environments. The model is delivered with the P50 hand probe for exact measurement and locating of leaks. PERFECT FOR AUTOMATIC LEAK TESTING The P has the same functions as the desktop model, but is designed for panel mounting into fully or semi-automatic systems for leak testing and leak detection. BATTERY POWERED AND TOUGH FOR ROUGH ENVIRONMENTS The C is portable and battery powered for maximum freedom in leak detection processes. With the battery charger connected, this model functions just as well as a stationary instrument.

Alternative alarms through different types of audio signals and/or visual indicators on the screen. Combined screen display for Measure and Locate improves the efficiency of the operator s work. Adjustable audio indication makes the measurement procedure easier. Choose between continuous audio signal, audio signal only at alarm level, or audio signal at a defined percentage of the alarm level. The audio alarm can be clearly heard even in noisy environments, and in cases where themeasurement point and the instrument are far apart. Easy sensor fitting makes it simple to replace the sensor in a matter of seconds. Short recovery time reduces downtime when detecting gross leaks. Built-in illumination source of the probe helps precisely position the probe tip. LED Leak/Tight indication in the hand probe provides the operator with fast information during the leak detection process. ACCESSORIES There are plenty of ways to increase your application area with the broad range of ISH2000 accessories. AP29ECO SAMPLING PROBE For automatic leak testing of entire products or parts of products. AP55 SNIFFER PROBE For fast manual leak location in hardto-reach places. AP57 COUNTER FLOW PROBE Provides a protective air curtain against a high background level of tracer gas.

Unique Sensistor sensor technology is at the very heart of INFICON hydrogen leak detectors and ensures unsurpassed selectivity, sensitivity and reaction time. High sensitivity detects smaller leaks and shortens the time for each test cycle. A choice between pre-defined measurement units for leak flow, PLUS programmable unit, supports the setting up of the instrument for different measurement situations. Multi-point measurement with accumulation of the values makes it possible to add several leaks and compare with the total threshold value. Long autonomy fast charging (for battery-powered model). Automatic and manual zero setting eliminates problems with high background levels of tracer gas. Simply push a button to eliminate background disturbance. Ergonomic hand probe with built-in intelligence facilitates the operator s control of the instrument. P50 FLEX HAND PROBE With a flexible neck. Facilitates leak detection in hard-to-reach places. SENSISTOR ILS500 LEAK TESTING SYSTEM For advanced control in automated systems. C21 PROBE CABLES In lengths of 3, 6 and 9 meters (9.8, 19.6 and 29.5 ft.) for a variety of test situations. TGF10 TRACER GAS FILLER For controlled filling and evacuation of tracer gas in the test object. H65 INSERT SENSOR Replaces the standard hand probe in automated tests. REFERENCE LEAKS For calibration and function tests of the.

APPLICATIONS The Hydrogen Leak Detector is the ideal instrument for finding typical liquid leaks. It is also the best choice in environments where large leaks occur occasionally. The combination of inexpensive tracer gas, flexible testing procedures and high reliability makes the optimal system solution for a variety of demanding applications. INDUSTRY INFICON hydrogen leak detectors are used to reliably test a variety of industrial products, such as plastic containers, hoses, valves and hydraulic components. High sensitivity and flexibility make the the natural choice for several industrial applications. High sensitivity Simple and accurate location of leaks Suitable for both automatic and manual measurement Inexpensive tracer gas Accurate leak size measurements AUTOMOTIVE Ensuring that fuel tanks, AC systems, oil pipes, gearboxes and light fittings are absolutely tight demands fast and efficient leak testing. The Sensistor method achieves high sensitivity and short cycle times. Simple leak location without using fluids Higher sensitivity than pressure-decay measurement The testing is unaffected by temperature variations The test method can be automated NIST traceability Accurate leak size measurements AEROSPACE Leaks in the fuel, oxygen or cooling systems often result in long and unpredictable repair times. The Sensistor ISH2000 instrument is unparalleled in simplicity and reliability both for maintenance and assembly situations. Clean and dry test method Exact location of invisible leaks High sensitivity Inexpensive tracer gas Complete system for gas injection For explosion proof detector option please see Extrima PACKAGING The opens the door to a completely dry test method that can easily be adapted, automatically or manually, to both flexible and hard packaging material. The tracer gas contains the approved packaging gases hydrogen (E 949) and nitrogen (E 941), which live up to the demands of the foods industry. Special model ISH2000 HySpeed for up to 4 tests per second Exact detection of the position of the leak Higher sensitivity than conventional methods RAC Leak testing using tracer gas is a standard procedure in the manufacture of white goods and air conditioning units. The dissemination capacity of hydrogen minimizes the risk of the detector being blinded in the event of major leaks. Inexpensive tracer gas Maintenance-free test equipment < 0.5 g/y equivalent refrigerant sensitivity (<0.02 oz/year for USA) No risk of the measurement probe becoming clogged MEDICAL High demands on quality control make the an attractive solution for leak testing implants, blood pumps, fluid bags, catheters and other types of consumables. The test method is completely dry and the tracer gas does not affect the material tested in any way. Higher sensitivity than pressure decay measurement Not affected by elastomeric creep Exact detection of the position of the leak Accurate leak size measurements PROCESS Extremely high demands on tightness are often made in the process industry. Pipe systems, valves and containers, hydrogen-cooled generators and fuel cells are just some examples. In the context of both production and service, hydrogen leak detection provides a fast and reliable method for tightness control and leak detection. Leak detection with portable equipment High sensitivity Superior method to bubble testing For explosion proof detector option please see Extrima

SPECIFICATIONS Minimum detectable leak rate Detection Mode with P50 standard probe Analysis Mode with P50 standard probe Start time Calibration Operating time (C) Charging time (C) 1x10-7 mbarl/s or cc/s with 5% H 2 0.5 ppm H 2 ; 5x10-7 mbarl/s or cc/s with 5% H 2 1 Minute External reference leak or calibration gas >9h at 20 C <7h at 20 C Inputs / Outputs 25 pin, D-Sub with status signals 24V DC / 0.5A 9 pin, D-Sub with RS232 Probe connector (P) Maintenance Power supply P C Dimensions (W x H x D) P C Weight P C * Charged using adapter supplied, 100-240 V, 50/60 Hz, 0.3 A Maintenance-free 100 240V AC, 50/60 Hz, 2 A 24V DC, 3 A Internal, rechargeable battery* (Li-Ion) 275 x 155 x 170 mm (11 x 6 x 7 inch) 275 x 140 x 75 mm (11 x 6 x 3 inch) 275 x 190 x 170 mm (11 x 7 x 7 inch) 3.9 kg (8.6 lb) excl. probe and probe cable 1.8 kg (4.0 lb) 4.0 kg (8.8 lb) excl. probe and probe cable ORDERING INFORMATION Part no. 590-750 P 590-760 C 590-770 Accessories Hand Probe P50 590-780 Hand Probe P50 Flex 590-790 Robot Probe R50 590-920 AP29ECO Sampling probe AP55 Sniffer probe 590-550 AP57 Counter flow probe 590-555 TGF10 Tracer gas filler 590-557 Sensistor ILS500 Leak Detection System C21 Probe cables H65 Insert sensor 590-250 Reference leaks Combox 590-820 590-035 (3cc/sec sample flow) 590-036 (1cc/sec sample flow) see separate data sheet 590-161 (3m, 9.8 ft) 590-175 (6m, 19.6 ft) 590-165 (9m, 29.5 ft) see separate data sheet www.inficon.com reachus@inficon.com Due to our continuing program of product improvements, specifications are subject to change without notice. niba60e1-d (1206) 2012 INFICON