Classification Report

Similar documents
DELTA Classification Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Centrum stavebního inženýrství a.s.

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

TFI Report Classification

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Test Report No: ICL/H17/7967

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

New European Cable Testing and Classification

Additional reaction to fire classification report No H

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Construction Products Regulation (CPR)

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Additional Reaction to Fire Classification Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Üntel is ready for CPR

Test Report: ICL/CR15/11/087

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Reaction to fire classification report No C

Construction Products Regulation (CPR) and BS 6701

Reaction to fire classification report No C-rev.1

Classification report

YOUR GUIDE TO UNDERSTANDING CPR

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

WORLDWIDE CABLE EXPERTS

Centrum stavebního inženýrství a.s.

TFI Report Classification

CLASSIFICATION REPORT

New European Fire Testing Classification for Construction Products

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

Copper and Fibre Cabling Infrastructure Offering - Europe

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Analysis Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Construction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

UK Direction BS7671 BS 8492 BS /01/2018

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

Form: KSD-100:10 Page 1 of 3

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Centexbel. General certification regulations. Construction products

The new Gas Appliances Regulation (EU) 2016/426

Guide to Gate Safety Legislation & the Machinery Directive

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

Catalogue Telecommunication Cables INTRODUCCIÓN

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

High Performance LSZH Fire Resistant Cable

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

Abrasion Resistance of Fluoropolymer and polyester Coatings

BCTC CARPET TECHNICAL CENTRE

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Total Fire Solutions. Includes BS 8519 and the updated BS :

BS EN ISO : 2010

~~oeti. Report VN71 O Classification Report. Reference

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Telecommunication Cables

EN 1155:1997 TESTS OF : PERKO R106 FS CONCEALED FIXED ELECTRICALLY POWERED FREE SWING DEVICES FOR SWING DOORS. Leopold Street, Birmingham.

BS EN : 2001 & IEC :2000

~,oeti. Report VN Classification Report. Reference

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

BS EN ISO 1716: Determination Of The Heat Of Combustion For Building Products

Havells Fire Survival Cables

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Comtran Cable. Hub-LINK Cables for Transit Applications

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

BS 476: Part 3: External Fire Exposure Roof Test. WF Report Number: Date: 28 th April Test Sponsor: Tapco Europe Limited

Europacable FAQ on CPR Status: 26/01/17

BS EN ISO : 2010

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Transcription:

Classification Report BASEC Client Report No. Hubbell Inc. (Delaware) L1CPRT801-1 Classification Number of pages in this Report: 6 Issue Date 3 January 2018 Items Tested 1 sample of Copper Communication Cable Specification(s) BS EN 13501-6:2014 Authorised by: Issue Date: I McGuinness 3 January 2018 Laboratory Manager This Classification Report does not represent type approval or certification of the product. This Classification Report shall not be reproduced except in full, without written approval of the laboratory. British Approvals Service for Cables Presley House Presley Way Crownhill Milton Keynes MK8 0ES UK T: 01908 267300 F: 01908 267255 Notified Body No. 2661 E: mail@basec.org.uk W: www.basec.org.uk

Introduction This classification report defines the classification assigned to the product, Copper Communication Cable, in accordance with the procedures given in BS EN 13501-6:2014 CLASSIFICATION OF REACTION TO FIRE FOR ELECTRIC CABLES IN ACCORDANCE WITH BS EN 13501-6:2014 Sponsor: Hubbell Inc. (Delaware) Prepared for: Hubbell Inc. (Delaware), Premise Wiring Division, Suite 103, 23 Clara Drive, Mystic, CT 06355, USA Prepared by: British Approvals Service for Cables, Presley House, Presley Way, Crownhill Milton Keynes, MK8 0ES, United Kingdom Notified Body No. 2661 Cable Family Name: U/UTP Cat 6 24AWG LSZH Classification Report No. L1CPRT801-1 Classification Issue number: 1 Date of issue: 3 January 2018 This classification report consists of 6 pages and may only be used or reproduced in its entirety. Report Issue Date: 03/01/2018 Page 2 of 6

Details of classified product General The product U/UTP Cat 6 24AWG LSZH is classified in accordance with the procedures given in BS EN 13501-6:2014 and is defined as a copper communication cable according to BS EN 50575:2014+A1:2016. Product description The copper communication cable U/UTP Cat 6 24AWG LSZH is as described in the Sample details below. Traceability The test sample was selected by UL on behalf of BASEC and received on 14 April 2107 Sample details Parameter Test sponsor Contact address Details Hubbell Inc. (Delaware) Premise Wiring Division, Suite 103, 23 Clara Drive, Mystic, CT 06355, USA Cables submitted for test U/UTP Cat 6 24AWG LSZH (Sample 62) Trade Name 4 pair 24AWG U/UTP cable. Class 1 (solid) copper conductors, HD-PE insulation, NHFR filler, NHFR jacket OD = 6.0mm SPEEDCHANNEL 4 PR/24AWG LSZH Category 6 U/UTP Cable Report Issue Date: 03/01/2018 Page 3 of 6

Reports & results in support of this classification Reports Name of Laboratory Name of test sponsor Test reports Nos. Test method/field of application rules BS EN 50399:2011+A1:2016 BASEC Hubbell Inc. (Delaware) L1CPRT773 BS EN 60332-1-2:2004+A11:2016 BS EN 61034-2:2005+A1:2013 L1CPRT773a BS EN 60754-2:2014 Results Test method Parameter No. tests runs Continuous parameter Results Compliance parameters FS 1.09m 1.5m = B2ca compliant THR1200s 4.6MJ 15MJ = B2ca compliant 1 Peak HRR 15.5kW 30kW = B2ca compliant BS EN 50399:2011 +A1:2016 FIGRA 104.9W/s 150W/s = B2ca compliant TSP1200s 15.9m 2 50m 2 = s1 compliant 1 Peak SPR 0.06m 2 /s 0.25m 2 /s = s1 compliant Flaming droplets/particles 1 <10s Flaming <10s = d1 compliant BS EN 60332-1-2:2004 +A11:2016 BS EN 61034-2005 +A1:2013 H 1 82mm 425mm = Eca compliant Minimum transmission 1 80.8% 80% = s1a compliant BS EN 60754-2:2014 ph/conductivity 3 ph = 5.2*, conductivity = 0µS/mm* ph > 4.3 + conductivity <2.5µS/mm = a1 compliant * The least best result for all components tested Report Issue Date: 03/01/2018 Page 4 of 6

Classification and field of application Reference of classification This classification has been carried out in accordance with BS EN 13501-6:2014 Classification The communication cable in relation to reaction to fire behaviour is classified: B2 ca The additional classification in relation to smoke production is: The additional classification in relation to flaming droplets / particles is: s1a The additional classification in relation to acidity is: d1 The format of the reaction to fire classification for electric cables is: a1 Fire Behaviour Smoke Production Flaming Droplets Acidity B2 ca - s 1a, d 1, a 1 Reaction to fire classification: B2 ca -s1a,d1,a1 The classification assigned to the products in this report is appropriate to a declaration of conformity by the manufacturer within the context of system 1+ attestation of conformity and CE marking under the Construction Products Regulation. Report Issue Date: 03/01/2018 Page 5 of 6

Field of application This classification is valid for the copper communication cables described in Sample details and listed below: Brand Name Cable Identification Product Code Hubbell Inc (Delaware) U/UTP Cat 6 24AWG LSZH C6SCBZFRB22cc SPEEDCHANNEL 4 PR/24AWG, LSZH, Category 6 U/UTP Cable Reaction to Fire Classification B2 ca-s1a,d1,a1 This classification is valid for all end-use applications. Limitations This classification will be valid whilst; The test methods remain unchanged, The product standard or technical approval remains unchanged, Constructional or material modifications do not exceed limits of the field of application. The manufacturer has made a declaration, which is held on file, that the product placed in the marketplace, named in the product description section of this report and produced at the manufacturing plant listed therein, is exactly the same as the product that was tested. This classification document does not represent type approval or certification of the product. - - END OF REPORT - - - Report Issue Date: 03/01/2018 Page 6 of 6