MOUNTING GUIDE. MOUNTING INSTRUCTIONS FOR MODULAR UNDERFLOOR HEATING MESH FOR INDOOR code PVMR

Similar documents
Heating Mat and Mesh for indoors, modular or customized

Intro. Intro. Table of Contents

electric floor heating Heating mats Heating cables Temperature controllers

ELECTRIC HEATING THERMOSYSTEM

electric floor heating Heating mats Heating cables Temperature controllers

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

UNDERWOOD HEATING SYSTEM

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

electric floor heating for everyone Heating mats Heating cables Temperature controllers

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Installation Guide For your AHT Underfloor Heating System

Toll Free:

LIFETIME. INSTALLATION MANUAL efoil WARRANTY

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

Installation Manual. Warmset. Warmset srl. Floor heating system

Underlaminate Foil Heater

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Always make sure to check the heating film before, during, and after installation of the floor covering.

Underfloor Heating Mat Installation Manual

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

Polymer solutions Heating mat EM2-CM

Classic Mats Installation Manual

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

FloorHeat Installation Manual

VADA - Rain2Main Automatic Rainwater Controller

Hydronic Underfloor Heating

Uponor Comfort E AL-Foil Mat

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com

INSTALLATION. For more information on this product or to order samples call or visit our website at builddirect.com.

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Installation Instruction

Carbon Film Installation Instructions

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

Instructions for the fan motor control system, SILVER C

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

IMPORTANT SAFEGUARDS Ensure that your mains supply voltage is the same as that marked on the underside of your kettle.

amuheat Cable Mat floor heating systems Installation Manual CM02-12

floor heating system

Contact Details. Please note that some of the contact details on this PDF document may not be current.

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

Electric Warm-Stretch under floor heating

V80-H Multistage Pump Instruction Manual

SMART Electronic control for towel radiators

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

F1202 TRACE HEATING. Road & Ramp

Undertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1

Underfloor Heating Inscreed Cable System

DOMOTHERM CLASSIC TWIN/S MAT

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

Installation Instruction Devidry - for installation with Devidry Pro Kit

INSTALLATION INSTRUCTIONS SINGLE CIRCUIT

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

Installation Manual. Warmset. Warmset srl. Floor heating system

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Royden. Look how easy it is to roll out the heat

ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

Carbon Fibre Heating Technology Heating Systems for Industrial Use

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Cooker Hood LA-72-CAN.

GB User and maintenance manual

IDL/ De Longhi Appliances via Seitz, Treviso Italia

MINI HAIRSTYLER. Straight & Curls HS 2930 ENGLISH

MX-DS1 Desoldering Gun for the MX-500P & MX-5200 Series

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

Greentrol Automation, Inc.

Operation Manual PM-NIT-14006E

When using an electric appliance, basic precautions should always be followed, including the following:

PO Box 827 Hawley, MN (218) Fax (218)

Installation And User Instructions

INSTALLATION INSTRUCTIONS: these are intended for the qualified technician who must carry out the installation, hook-up and testing of the appliance.

OWNER S MANUAL FOR ELECTRIC FRYERS. Model Numbers PARAFRYER (240V) ELECTRIC FRYER

Underfloor Heating Cable Installation Manual

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

PROFESSIONAL HAIR STYLER

PRO SPEED Model 5541CU

ELECTRIC ASH CAN Model: CVACASH500 Part No:

Electrical Heating Solutions. Energy efficient building technology

TH100 Three in One Instant Hot Water Tap

INSTALLATION AND USER INSTRUCTIONS BUILT-IN ELECTRIC DEEP FAT FRYER DF-Z01

900W OIL FILLED RADIATOR

INDUSTRIAL GLASS AND DISHWASHER USERS MANUAL - -

BIG HAIR. Model 2775U

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

MBCE-110/230UV Flame Sensor Module

Steam Mop with Foldable Handle 1500W

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

DIRTY WATER SUBMERSIBLE PUMP KIT

INSTALLATION AND MAINTENANCE INSTRUCTIONS

HOM COLLECTION. h tab ELECTRICAL TOWEL WARMER. INSTALLATION INSTRUCTION Pag. 2

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

Transcription:

MOUNTING INSTRUCTIONS FOR MODULAR UNDERFLOOR HEATING MESH FOR INDOOR code PVMR MOUNTING GUIDE WARNING: only qualified personnel must perform installation. A B A. Before starting the montage it is indispensable to know exactly how the elements must be disposed on the floor surface, by following the project, which indicates their disposal and the points of power supply. Lay out the elements ensuring that the floor surface is flat and clean. C B. Each element has a label on the margin with the text LATO SCALDANTE/HEATING SURFACE. The elements must be laid side by side, they must not overlap and/or fold and they must not be larger than the laying surface. D Gomma IP67 - Rubber IP67 C. Afterwards you can proceed with elements linkage using special connectors, placed on the corner of each heating element. E D.The connectors have a mandatory direction of linkage, which must be respected. The male connector is equipped with black rubber IP 67 for insulation,which SHOULD NOT BE REMOVED. F E. Proceed with installation testing by inserting temporarily the power cord plug into the electric outlet. Do not let the heaters powered more than 2 minutes. F. Check weather each element heats. Using a current clamp, check the correct power consumption confronting it with power indicated on the label of each element. The measurement could slightly differ from the indicated values (grid tension is not constantly at 230 Vac). The measurement must be performed after each phase of installation: element laying, screed application, tiling or else. http://www.thermaltt.com/resources/products-pdf/heating-pdf/interior-heaters-pdf/pvmr_instructions_en.pdf PVMR - pag. 1 of 6

G H G. The modules are equipped with heat-shrinking sheath for connector insulation, which is fixed near male connector. H. If the heating test is positive, the sheath must be detached and inserted on the male connector. If the testing was negative, control each element until you find the defected heater, which must be replaced. I L I. Link the male connector with female connector of the next module, paying attention to the blocking tabs, they should be well inserted. Male connector is equipped with black rubber IP 67 for insulation, WHICH SHOULD NOT BE REMOVED. Apply the heat shrinking sheath to cover the connection. L. Heat the sheath by aim of hot air gun or something similar. M N M. Verify the sheath, which must adhere perfectly on all the connecter s surface. N. Cover the connection with provided tissue. http://www.thermaltt.com/resources/products-pdf/heating-pdf/interior-heaters-pdf/pvmr_instructions_en.pdf PVMR - pag. 2 of 6

O P O. If two enclosed heating elements do not have coincident connectors, use the extension cord (see table 2 at page 4) for their connection. P. Extension cord linkage with a connector. Q R Q. Once all the elements are connected, it is necessary to insulate with a tap the connector of the first installed element, left free. NOT BE REMOVED BLACK RUBBER. R. Link the connector left free of the last installed heating element, with a proper power cord (see table 2 at page 4). S T S. Once made all the necessary links, verify the connectors are well joint, than insert the power cord into the outlet, or, eliminating the outlet, link it with a chrono thermostat. T. Use elastic adhesive (for example Mapei Keraflex or Mapei Keraflex Maxi) and plastic toothless spatulas and tools to apply the glue. Apply a light glue layer; the adhesive must cover the mesh. Let the glue to dry. Start floor finish ng application, using again, an adhesive on elastic basis and plastic, toothless tools.it s possible to cover the mesh with a self-leveling. http://www.thermaltt.com/resources/products-pdf/heating-pdf/interior-heaters-pdf/pvmr_instructions_en.pdf PVMR - pag. 3 of 6

HEATING MESH BETWEEN CEMENT SCREED AND CERAMIC-SANDSTONE-MARBLE FLOOR Installation between screed and floor allows fast heating of the room and rapid achievement of thermal inertia due to the small thick of the system. The system is recommended for places with occasional use, for example: holiday homes, offices, shops, meeting rooms, restaurants, hotel rooms, etc... 1. Ceramic-marble floor. 4. Cement screed. 5. Insulating panel. 6. Filling sub-base. 7. Floor slab. HEATING MESH BETWEEN CEMENT SCREED AND WOOD/LAMINATE FLOOR Installation between screed and floor allows fast heating of the room and rapid achievement of thermal inertia due to the small thick of the system. The system is recommended for places with occasional use, for example: holiday homes, offices, shops, meeting rooms, restaurants, hotel rooms, etc... 1. Wooden/laminate floor, glued or floating. 4. Cement screed. 5. Insulating panel. 6. Filling sub-base. 7. Floor slab. HEATING MESH ON TOP OF EXISTING FLOOR This installation method is ideal for renovation works, when should be avoided the overloading of the floor slab, and inside height maintained. Installation between cement screed and new floor allows fast heating of the room and rapid achievement of thermal inertia due to the small thick of the system. The system is recommended for places with occasional use, for example: holiday homes, offices, shops, meeting rooms, restaurants, hotel rooms, etc... 1. Ceramic/marble floor 4. Old tiles floor. 5. Filling sub-base. 6. Floor slab. HEATING MESH ABOVE INSULATING PANEL The installation involves gluing the tiles or wood directly on an insulating panel (polystyrene panel with a special resin surface). This method of installation creates a mass to be heated only 1.5 cm thick (tile + adhesive) allowing to achieve the desired surface temperature in the shortest time. 1. Ceramic/marble floor 4. Insulating carrier panel. 5. Filling sub-baseo. 6. Floor slab. 6. Solaio. http://www.thermaltt.com/resources/products-pdf/heating-pdf/interior-heaters-pdf/pvmr_instructions_en.pdf PVMR - pag. 4 of 6

CONNECTION TO POWER SUPPLY The module provides two output cables for the electrical connection. It must be powered at 230Vac. The temperature is regulated through a thermostat. Protezione impianto/wiring protection ELECTRICAL INSTALLATION CONFIGURATION EXAMPLE Termostato zona 1 Zone 1 thermostat L1 N1 -Q1 230 Vac Neutro/Neutral L1 N1 -T1 Interruttore differenziale 1P+N 25A RCD 1P+N 25A Elemento riscaldante/modular mesh Elemento riscaldante 1 Modular mesh 1 - R1 xxxwatt 230 Vac Relè/Relay TABLE 1 - DIMENSIONS OF STANDARD MODULES CODE DIMENSIONS (cm/in) m 2 /ft 2 POWER CODE TABLE 2 - MODULAR MESH ACCESSOIRES DESCRIPTION PVMR.060100 60X100 / 23.62x39.37 0,60/6.46 60W PVMR.060150 60X150 / 23.62x59.05 0,90/9.67 90W PVMR.060250 60X250 / 23.62x98.42 1,50/16.15 150W PVMR.060350 60X350 / 23.62x137.79 2,10/22.60 210W PVMR.090150 90X150 / 35,43x59.05 1,35/14.53 135W PVMR.090250 90X250 / 35.43x98.42 2,25/24.22 225W PVMR.090350 90X350 / 35.43x137.79 3,15/33.91 315W PVMR.090450 90X450 / 35.43x177.16 4,05/43.59 405W PVMR.150150 150X150 / 59.05x59.05 2,25/24.22 225W PVMR.150250 150X250 / 59.05x98.42 3,75/40.36 375W PVMR.150350 150X350 / 59.05x137.79 5,25/56.51 525W PVMR.150450 150X450 / 59.05x177.16 6,75/72.66 675W PVMM.00PL80 PVMM.0PL200 PVMM.0PL400 CODE Power supply Power consumption Protection degree Cables and Connectors Extension cord module module 80 cm (31.50 in) Extension cord module module 200 cm (78.74 in) Extension cord power module 400 cm (157.48 in) TABLE 3 - TECHNICAL FEATURES DESCRIPTION 230 Vac 50/60 Hz max 8A from 25W/m2 to 100W/m2 IP67 FG7 power cable - IP67 connectors Phone: + 40 359 800 893 - Fax: + 40 359 800 894 - www.thermaltt.com - info@thermaltt.com http://www.thermaltt.com/resources/products-pdf/heating-pdf/interior-heaters-pdf/pvmr_instructions_en.pdf PVMR - pag. 5 of 6

INSTALLATION IN AMBIANCES WITH OCCASIONAL OR CONSTANT PRESENCE OF WATER Install a metallic grid above the heating elements, which must cover the entire installation including fixing points The grid must be protected against the corrosion but not insulated electrically. The grid must be connected to earthing system. The grid must have adequate clamps for connection of 2 conductible cables, each having a section of 4 mm² if not protected mechanically, and a section of 2,5 mm² if mechanically protected. Perform operational tests for electric continuity before proceeding with following installation phases. WARNINGS The relays, cables and the residual-current breaker must be dimensioned in dependence of the rated power of the installed elements sum. The circuit must be protected by a device able to interfere and section the power line in case of short circuit; it must be installed an automatic cut out residual current breaker with Id 30mA current or with insulation transformer. A planimetric map should be placed near the distribution switchboard, with indication of the supply points of the heating system. The power line minimal section must be of 1,5 mm² from the protective switch to the heater; respecting the rated current of the source protection. Each circuit must have elements linked together for a maximum power of 1.700W / 8A; in case this power is exceeded it must be divided in several circuits. Do not use the heating elements on surfaces with an inclination over the 45 on vertical. The heating system should not be used by persons (including children) whose physical, sensory or mental capabilities; or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction. Do not let children play with the appliance. If one or several power cables are damaged, they must be replaced by qualified personnel, indicated by manufacturer or distributor. In case of installation under a metallic finishing, it must be connected to earthing. CAUTIONS Do not pierce, cut, or damage the heating elements. Do not poor liquids. Do not burn. Do not lay the heaters on the disconnected surfaces. Do not power the heater if it is rolled. Do not install outdoor. Do not power with different voltage from that indicated by manufacturer. Install the elements by orienting their heating surface upwards, respecting the indication label Heating surface. The heating elements must be kept away from another heat sources as lighting equipment or fireplaces If you want to use different products than those specified here, please contact the manufacturer The thickness of the finishing material (ceramics, laminate, etc.) must be at least 5,00 mm. Do not use this heating system if outside temperature is lower than 30 C. The heating elements must be installed at a distance of at least 30 mm from the conductive parts of the building, like pipes (methane gas pipelines included, if not protected by sheathing or cement/mortar). Maximal power of each circuit with connected elements is of 1.700W / 8A; if this power is exceeded it must be divided in several circuits. IF YOU NEED ANOTHER INFORMATION CONTACT THE SUPPLIER (The manufacturer declines all responsibility in case of improper use.) Appropriate for installation under flooring Do not burn or fire Do not install on disconnected surfaces Do not wet Equipped with reinforced insulation SAFETY REGULATIONS The device should only be operated with a voltage of 230 Va 50/60 Hz. Users must not perform any reparation of the product. In case of short circuit and/or another damage, please contact the manufacturer. The connection to the electric grid must be performed by qualified personnel from authorized companies by normative 46/90 D.M. 37, January 2008. ATTENTION!!!! Risk of electric shock. Close the connectors before powering the circuit. CONFORMITY This product complies with the electrical safety measures in accordance with 2006/95/EC Low Voltage Directive. The product complies with the 2004/108/EC, which refers to the electromagnetic fields. Do not dispose the product in environment in order to avoid potential damage to people and objects. To facilitate the disposal of the components/materials and protect the environment itself, take the product to special collection centres. Product disposal in the environment or common waste is penalized in accordance with current legislation. Phone: + 40 359 800 893 - Fax: + 40 359 800 894 - www.thermaltt.com - info@thermaltt.com http://www.thermaltt.com/resources/products-pdf/heating-pdf/interior-heaters-pdf/pvmr_instructions_en.pdf PVMR - pag. 6 of 6