,Chaojian He6, f. School of Guangxi University, Nanning , China.

Similar documents
A study of Transient Performance of A Cascade Heat Pump System

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

Experimental study of fan coil assisting radiant floor heating system

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Best Row Number Ratio Study of Surface Air Coolers for Segmented Handling Air-conditioning System

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Thermal Comfort with Convective and Radiant Cooling Systems

ABHINAVA KARABA, V VIJENDRA BHAT, PRAMOD UPADHYAYA R, ANUPRAJ JATHANNA, ARUN M KRAMADHARI

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Analysis on combinations of indoor thermal microclimate parameters in radiant cooled residential buildings and drawing of new thermal comfort charts

American Society of Heating, Refrigerating and Air-Conditioning Engineers

Simulation of Full-scale Smoke Control in Atrium

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

IMPLEMENTATION OF DISPLACEMENT VENTILATION SYSTEM BY USING A WALL-MOUNTED AIR CONDITIONER

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

Study on an environmental simulation system of low/high temperature. for great space

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

Optimisation of cooling coil performance during operation stage for improved humidity control

Recent Advances in Energy, Environment and Economic Development

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Comparison of radiant and convective cooling of office room: effect of workstation layout

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Available online at ScienceDirect. Energy Procedia 70 (2015 ) Yanjun Dai*, Xian Li, Ruzhu Wang

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

To describe human body heat transfer, the concept. Thermal comfort with radiant and convective cooling systems. Articles. REHVA Journal June

Flexible and efficient: Close Climate Control for IT equipment

A study of radiant cooling for a room with daytime application in tropical climate

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

The Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

EFFECT OF SATURATION EFFICIENCY OF DIRECT EVAPORATIVE COOLER ON INDOOR CONDITIONS AND THERMAL COMFORT IN A SMALL OFFICE ROOM OF A BUILDING

Performance of the Variable Refrigerant Volume Air-Conditioning System. with Heat Recovery

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

Study on a novel variable capacity technology and control strategy for refrigerated shipping container unit

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental study of space cooling using ceiling panels equipped with capillary mats

K.F. Fong *, C.K. Lee, T.T. Chow

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

A STUDY ON THE APPLICATION OF THE RADIANT FLOOR COOLING SYSTEM INTEGRATED WITH A DEHUMIDIFICATION SYSTEM

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Development of Large Size Hybrid Fan

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

A new method for preventing air-source heat pumps and refrigerators from frosting

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

How to ensure Thermal Comfort in buildings with CFD

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Application of Fuzzy Control in Central Air-conditioning Terminal Units Energy-saving

Comfort and health-indoor air quality

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

A Novel Approach for the Thermal Management. of PC Power Supply

Performance enhancement of photovoltaic household refrigerator using a phase change material in contact with evaporator

Review of Temperature and Humidity Control Technology for Air Conditioning and Heat Pump Systems Paper 2386

Design of Humidity Monitoring System Based on Virtual Instrument

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Human response to thermal environment in rooms with chilled beams

Transcription:

5th International Conference on Environment, Materials, Chemistry and Power Electronics (EMCPE 2016) The Research on Running Characteristics of A New Type of Radiant Air Conditioning Combined with Fresh Air System Yingning Hu1, a, Xuan Yao2, b, Weiming Zhong3, c, Yan Wang4, d Shanshan Hu5, e,chaojian He6, f. 1 School of Guangxi University, Nanning 530004, China. 2 School of Guangxi University, Nanning 530004, China. a hyn@gxu.edu.cn, bmissailisi@126.com, czwm198@126.com, d532807271@qq.com, e chloee_2000@163.com, fhcj_2016@163.com Keywords: Radiant air conditioning, Fresh air system, Temperature field, Comfortable, Running performance, Energy-saving Abstract: The aim of the article is to comprehensively test and explore the running performance of a new type of radiant air conditioning combined with fresh air system by simulating the climate that summer is hot and winter is warm, which is developed by the laboratory research group. The test results show that, Under the working conditions of refrigerating, heating and dehumidifying, The indoor temperature difference is about 2 in horizontal direction and less than 1 in vertical direction. The temperature distribution is uniform and indoor thermal environment is comfortable. the fresh air system has higher dehumidifying effect so it is able to prevent condensing phenomenon and the running performance of the system is stable and reliable. Introduction With the progress of science and technology and the change of lifestyle, People's Daily life almost spend 80% time in the room so it has an increasing demand on indoor environment. Radiant air conditioning with comfort, health, environmental protection and energy-saving gets extensive attention and application gradually. Domestic and foreign scholars have studied all aspects in the field of radiation air conditioning. Corgnati S P et al[1] carried out the numerical simulation experiments by CFD in two conditions of using mixed ventilation system separately and combined with ceiling radiant cooling system together. Results showed radiant system and ventilation system used together would make the indoor air quality more comfortable. Aleksandra et al[2] put forward when the temperature of supplying air provided by personalized ventilation system was 25 it was beneficial to improve the indoor thermal environment. At the same time personalized ventilation system provided 10 times fresh air than hybrid ventilation system which can improve indoor air quality. Yoshidomi T et al[3] assessed the performance of radiant ceiling system on-site. They found that no matter in heating or cooling mode, the indoor temperature difference at 0.1 m and 1.7 m in vertical direction was less than 1.5 the level of 0.7 m in horizontal direction was less than 1.5. At the same time they measured the range of PMV was ±0.5 and PPD was less than 10%. De Adana et al[4] predicted the time range for the ceiling radiant cooling system by liquid (water) circulation heating to achieve the set point for thermal comfort in the room with different heat load by experimentation. Moon Keun Kim et al[5] and Catalin Teodosiu et al[6] found that the radiant system combined with ventilation system can improve the air dew-point temperature on the ceiling surface, which not only to avoid the risk of condensation but also save energy consumption by numerical simulation and experiment analysis. Oxizidisa S et al[7] indicated that according to the indoor temperature to adjust the water temperature and then to control the radiant system, which was able to prevent the damage of air conditioning equipments due to frequently turn on compressor and the waste of energy consumption. Takehito Imanari et al[8] and Yasin Khan et al[9] analyzed the energy consumption and thermal comfort between ceiling radiant cooling system and traditional all-air system. Experiments showed 2016. The authors - Published by Atlantis Press 351

that the radiant air conditioning system can excellently provide suitable temperature range and uniform temperature distribution and the energy-saving is over 10% than traditional all-air system. Most studies about radiant air conditioning system at home and abroad used water as heat exchange medium, its running effect was strongly influenced by supplying water temperature. In this paper, there was a new type of radiant air conditioning combined with fresh air system that temperature and relative humidity can be controlled independently and the fresh air system can dehumidify fresh air before it getting into the room therefore indoor comfortable level was high and more energy efficiency. Experimental platform In this paper, the experimental platform is composed of two rooms, The size of big room is 7.8 m * 5.8 m * 5.8 m that depend on conventional air conditioning and ultrasonic humidifier to simulate the temperature and humidity of outdoor environment; the size of small room is 4 m * 4 m * 2.8 m that install the new type of radiant air conditioning combined with fresh air system. The new type of radiant air conditioning combined with fresh air system with the rated power of 2.2KW was consisted of the radiant module and the air system. The whole unit used refrigerant ( R410A) as the medium. The operation schematic diagram of this new radiant air conditioning was shown in figure1. Fig. 1 Operation schematic diagram of the new radiant air conditioning Experimental design This experiment respectively simulated the outdoor temperature and relative humidity of summer, winter, transition seasons and then run the new radiant air conditioning combined with fresh air system in the test room to research the indoor temperature distribution and running performance and dehumidifying efficiency of the system. On refrigerating and dehumidifying conditions there was extra heat load of 500w in the room, which was equivalent of the total heat load from fluorescent lamp, computer, doors and windows normally. Result and analysis The change of temperature and humidity of indoor environment directly influence the comfortable feeling of people, and low energy consumption is important indicator of economic and environmental. So this article aims at researching indoor temperature field distribution, dehumidifying efficiency of the air system, running performance of system and energy consumption 352

under different working conditions. Refrigeration Condition [simulative ambient: T=35, RH=80%] The changing of indoor temperature field Fig. 2 The ceiling surface temperature Fig. 3 The vertical temperature From the figure 2 we can seen that temperature changing trend of tests are consistent and the maximum temperature difference is about 1.8. When achieving steady state the ceiling surface (plane A) temperature basically maintain at 22.2, it is so higher than the dew-point temperature of air that it can prevent condensing phenomenon in the process of refrigerating.. In the figure 3 we found the average temperature of plane A, plane B and plane C all fluctuate slightly, the maximum temperature difference is about 1.2 in the vertical direction. After 2.5 hours indoor temperature has dropped from 31.2 to 23, the average cooling rate was fast. Data showed that indoor temperature field distribution is uniform and temperature gradient is small, so the thermal performance of indoor environment is well. Running performance of the system Fig. 4 Running performance of the system Figure 4 showed the changing trend of refrigerant temperature into/out of radiant panels and the air system are consistent. After 1 hour the running performance achieved stability. Temperature difference of refrigerant into/out of the radiant panel and the air system were 4.9 and 4.6. By the effect of simulative environment, the temperature fluctuations of the refrigerant into/out of air system is slightly bigger than the refrigerant into/out radiant panel. But the maximum swings was below 2.5, which showed that refrigerant conducted on thermal cycling effectively and the running performance of unit is stable, reliable and efficient. 353

Heating Condition [simulative ambient: T=5, RH=70%] The changing of indoor temperature field Fig. 5 The ceiling surface temperature Fig. 6 The vertical temperature From the figure 5 we can see that all test points are periodically changed with time. The temperature range of ceiling surface was 26.6 ~ 28.2 and the fluctuant amplitude is less than 2. From the figure 6, in horizontal direction the maximum temperature difference does not exceed 2. Plane B was equal to near the height of the head when a man sitting in the room and plane C closed to the height of the ankle. Temperature difference of plane B and plane C was minimal so that human body would feel comfortable. After 4 hours the temperature field achieved steady state and the average temperature kept at 25.3 in the room, which meeting the requirements of national standard[gb50736-2012] of comfortable air conditioning. 3.2.2 The running performance of system Fig. 7 Running performance of the system From the figure 7, Temperature difference of refrigerant into/out of the radiant panel and the air system were 15 and 27, heat transfer was large at system terminal. After 9.5 hours, the inverter compressor appeared the reverse circulation phenomenon to defrost and spend 6 minutes on defrosting a time, which effectively protected the heating capacity and prolong the service life of the unit. Inverter control system of the unit is agility and running performance of the system is stable and reliable. 354

Dehumidifying Condition [simulative ambient: T= 20, RH=85%] The change of Indoor temperature field Fig. 8 The ceiling surface temperature Fig. 9 The vertical temperature It can be seen from the figure 8 and figure 9 that the temperature curve of ceiling surface waved gently and the maximum temperature difference is about 1. When achieving steady state the ceiling surface temperature is 19.5, it was also higher than the dew-point temperature. Plane C closed to the floor so it is affected by the temperature of supplying air slightly and the volatility is slightly heavy than plane B. After 1.5 hours, the indoor average temperature achieved 19.8. In the vertical direction the maximum temperature difference was less than 1. The temperature field distribution in the room was very uniform and thermal environment was comfortable. Dehumidifying efficiency of fresh air system Fig. 10 The change of temperature and relative humidity Figure 10 showed that the indoor temperature and relative humidity changed with the supplying air temperature and relative humidity. We can get relative humidity ratio of air by checking the enthalpy wet figure, as shown in table 1. Table 1 Humidity ratio of supplying air, indoor air and outdoor air Name The average The average relative Humidity ratio temperature( ) humidity(%) (g/kg dry air) supplying air 15.4 55.1 6.04 indoor air 19.8 60.9 8.86 outdoor air 22 87.5 14.71 From table 1 we can see that relatively to outdoor air the dehumidifying quantity of air system is 8.67 g/kg and the relative humidity is 60.9% in the room, which meet the requirements of national standard [GB50736-2012] of comfortable air conditioning. The dehumidifying capacity of air system is great. 355

Power consumption of the system The power consumption of air conditioning is the important indicator on energy-efficient of building and how to reduce the power consumption is always the development proposition in the field of HVAC. In this experiment, after running the system on 24 hours under the working conditions of refrigerating, heating and dehumidifying respectively the power consumption is 11.9, 10.1, 8.7 KWh. The power consumption of refrigeration condition is highest and dehumidifying condition is minimum. If used a conventional air conditioning in the same room and the EER (energy efficiency ratio) of unit in cooling mode is 3, we can calculate the power consumption is 20.4 KWh. The new radiant air conditioning system was energy-saving 42% than a conventional air conditioning. Conclusion 1)The indoor temperature were 23, 25.3 and 25.3 respectively on the working conditions of refrigerating, heating and dehumidifying. The maximum temperature difference in the room all less than 2, the temperature field distribution was uniform and the indoor thermal environment was comfortable. 2)On the working conditions of refrigerating and dehumidifying, the ceiling temperature was much higher than the dew-point temperature of air and the air system can prevent condensing phenomenon. 3)Temperature difference of refrigerant into/out of the radiant panel and the air system remained stable, refrigerant conducted on thermal cycling effectively and the running performance of unit is stable, reliable and efficient. 4)On the working conditions of refrigerating, heating and dehumidifying respectively the power consumption is 11.9 KWh, 10.1 KWh, 8.7 KWh. With the same conditions the new radiant air conditioning combined with fresh air system was energy-saving 42% than a conventional air conditioning. Reference [1] Corgnati S P, Perino M, Fracastoro G V, et al. Experimental and numerical analysis of air and radiant cooling systems in offices[j]. Building and Environment, 2008,44(4). [2] Lipczynska A, Kaczmarczyk J, Melikov A K. Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling[j]. Building and Environment, 2015,92:603-614. [3] Li R, Yoshidomi T, Ooka R, et al. Field evaluation of performance of radiant heating/cooling ceiling panel system[j]. Energy and Buildings, 2015,86:58-65. [4] De Adana, Ruiz M, Olmedo, et al. Experimental Evaluation of the Thermal Comfort in an Occupied Office under Transient Conditions using a Hydronic Radiant Ceiling Cooling System[J]. ASHRAE Transactions, 2014,120. [5] Kim M K, Leibundgut H. Evaluation of the humidity performance of a novel radiant cooling system connected with an Airbox convector as a low exergy system adapted to hot and humid climates[j]. Energy and Buildings, 2014,84:224-232. [6] Teodosiu C, Ilie V, Teodosiu R. Numerical Prediction of Thermal Comfort and Condensation Risk in a Ventilated Office, Equipped with a Cooling Ceiling[J]. Energy Procedia, 2016,85:550-558. [7] Oxizidis S, Papadopoulos A M. Performance of radiant cooling surfaces with respect to energy 356

consumption and thermal comfort[j]. Energy & Buildings, 2013,57. [8] Imanari T, Omori T, Bogaki K. Thermal comfort and energy consumption of the radiant ceiling panel system.: Comparison with the conventional all-air system[j]. Energy and Buildings, 1999,30(2):167-175. [9] Khan Y, Khare V R, Mathur J, et al. Performance evaluation of radiant cooling system integrated with air system under different operational strategies[j]. Energy and Buildings, 2015,97:118-128. 357