Attention Items: I. Brief Introduction

Similar documents
Intelligent Speed Dome Installation Manual. Version 1.0.0

IR Intelligent Positioning System Installation Manual

IR Intelligent Speed Dome Installation Manual

High Speed Positioning System Installation Manual

Network Speed Dome Installation Manual

IR Intelligent Speed Dome Installation Manual

EST User Manual. (Please read this manual carefully before using)

2-inch Network Speed Dome Installation Manual

2-inch HDCVI Speed Dome Installation Manual

SCR100 User Manual. Version:1.1 Date:Dec 2009

Danfoss gas detection unit Type GD Heavy Duty

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Addressable NAC Output Module D327A

Analog Room Pressure Monitor RPC Series

EL-USB-1-LCD Temperature Data Logger with LCD

InBio X60 Series Access Control Panel User Manual

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Installation Guide for inbiox60 Series Access Control Panel

Models TX-KE and TX-KP Toxic Gas Transmitters

C Installation and Operation Manual

EasyLog Data Logger Series

Presented By. BEI Security

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

2-wire Passive Intelligent Loop (LED) Display Meter

6-inch Intelligent Speed Dome Installation Manual

E1000 Portable gas detector

Dahua 2-inch HDCVI Speed Dome Installation Manual Version Dahua Technology CO., LTD

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

PH/ORP PH/ORP Tester. Instruction for use

EasyLog Data Logger Series

IMR EX610. Portable Gas Detector. Operation Manual

2-wire Passive Intelligent Loop (LED) Display Meter

RS485 MODBUS Module 8AI

SonoSelect and SonoSafe energy meters

Installation and Operating Manual

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

APPLICATION DATA SHEET

Dahua 2-inch Network Speed Dome Installation Manual Version Dahua Technology CO., LTD

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

LH-20S (RESISTANCE ALARM SYSTEM)

Interface and EOL Modules 8

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

EL-OEM-3 OEM Packaged Voltage Data Logger

Dryer Controller M720

DC Inverter Smart VRF Products(R410A)

ACTIVE INFRARED BARRIER

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Recalibrate the way you look at gas detection

EL-USB-1-LCD Temperature Data Logger with LCD

System 57. An advanced world of intelligent gas detection system management

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

GLD-30 Gas Leak Detector

LIGHTNING PROTECTION SYSTEM

Distribution Control Center Operator Training

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

Frequently asked questions: Intelligent Transmitter Series

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Gas Detection System TOX ALARM DG2000-Garage

Operating Instructions

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

PMAC202 Branch Circuit Power Meter User Manual V1.0

IMR IX176 Portable Gas Detector User Manual

Wireless Weather Station with Solar Transmitter Instruction Manual

Fiber Optical Multiplexer

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

On the job around the clock 24/7: Fire detection systems

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Danfoss gas detection units

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

NetworX Series NX-870E Fire Supervision Module Installation and Startup

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

SPECIFICATIONS. HCA131A-High Accuracy 4 directions Control Switch(Switch Output) Item No.:HCA131A

GSM POWER ALARM SYSTEM

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

PORTABLE MOISTURE DETECTOR

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Touchpoint Pro Flexible Gas Control System

IM20-ZWAVE Magnetic Contact User Guide

EL-OEM-3 OEM Packaged Voltage Data Logger

3-inch 2 Megapixel Intelligent Network Speed Dome Installation Manual. Version 1.0.0

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Hydrazine Analyzer Series 2171 Specifications

Two-Channel Gas Controller

SPACE DETECTOR SP Presentation

Installation Manual. Read the user manual carefully before using this product

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SonoSelect and SonoSafe energy meters

Transcription:

1

Content Attention Items:... 3 I. Brief Introduction... 3 II. Model Difference... 3 III. Technical Specifications... 4 IV. Detector Structure... 5 V. Network Structure... 5 VI. The Principle and Application of Detection... 6 VII. Wiring Instructions... 9 VIII. Install Caution... 9 IX. Power Supply Way Choice... 9 X. Basic Equipment... 9 2

Attention Items: Thank you for purchasing ETCR2800 series products Non-Contact Ground Resistance Online Detector of the company In order to make better use of the product please be certain: To read this user manual carefully. To comply with the operating cautions presented in this manual. Apply to return circuit ground resistance, metallic return connection resistance, grounding conditions on-line monitoring. Single point grounding system, needs to increase assistance after the ends of the earth form a loop, then install detector. Note that this detector specified measuring range and using the environment. Protection against rain shower and water logging of installation. Install waterproof and rainproof of device at outdoors. Detector signal line connected port towards the ground. The dismantling, calibration and maintenance the Detector shall be operated by the authorized staff. If the continuing use of it would be dangerous, the Detector should be stopped using immediately, and immediately sealed for the treatment by the authorized agencies. I. Brief Introduction Non-Contact Grounding Resistance Online Detector is our company devotes ourselves to Grounding resistance test technical research s another new high-tech product for more than ten years, built for online monitoring grounding down lead connection status, return circuit grounding resistance and metal return circuit connection resistance well-designed manufactured. on-line testing, non-contact measurement, grounding wire pass through the hole, definitely not influence grounding for lightening effect and facilities normal operation, real time on-line testing. Detector provides power supply and RS485 signal interface, provides standard MODBUS-RTU communication protocol, which is convenient for doing second development. Detector can install and use singly, and also set up a network, realize long-distance on-line monitoring. Detector internally installs sensor and circuit board, completely seals, possesses features of protection against rain, dust prevention, resistance to high low temperature, corrosion prevention, inflaming retarding etc., ensure high-accuracy, high stability and high reliability of long time on-line monitoring outdoors, underground mine and indoors. Non-Contact Grounding Resistance Online Detector applies to electric transmission line pole ground connection, underground mine device ground connection, Meteorological lightning protection ground connection, petrochemical engineering ground connection, communication ground connection, rail facility ground connection, building the warehouse ground connection, electrical equipment ground connection etc.. II. Model Difference Model ETCR2800B ETCR2800C Difference Explanation Detector without display, user needs to do secondary development according to offered RS485 communication protocol, to monitor the detection data. Detector owns LCD display, Alarm setting, audible and visual alarm instructions and can be independent installation and use, and also does secondary development according to offered RS485 communication protocol and organizes a network. 3

III. Technical Specifications Function Power Supply Resistance Range Return circuit grounding resistance on-line monitoring, metal return resistance connection online monitoring, grounding condition monitoring. Detector: DC6V~DC9V,50ma Max. 0.01Ω~200Ω Resolution 0.001Ω Indication Range 0.00Ω~500Ω Accuracy ±2%rdg±3dgt(20 ±5, below 70%RH) Grounding Wire Perforation Size Overflow Indication Connecting Line Connection Identifier Protocol Standard Alarm Indication Alarm Setting Data Display LCD Dimensions Detector Dimensions Installing Screw Hole Size Quality Working Temperature And Humidity 60mm 30mm, closed mode (60mm 4mm steel flat or external diameterф30mm electric cable) When show value is beyond 500Ω, systems software and LCD show OLΩ sign. A one meter long wire(5cores shielded wire) Red/brown---power supply input anode; Black--- power supply input cathode; Blue---RS485 signal anode; Grey---RS485 signal cathode; White--- analog grounding (power supply input cathode can connects with analog grounding by short circuit connection) RS485 standard MODBUS-RTU communication protocol ETCR2800C:Detector Audible and visual alarm instructions ETCR2800C:Detector panel setting ETCR2800C:4digits LCD direct indication 47mm 28.5mm 175mm 170mm 130mm Φ8mm Detector: 960g Humiture Error Within 5% Shift GND Interference Current External Magnetic Field External Electric Field Single Measurement Of Time Power Consumption Installation Level Of Protection Installation Requirements Power Supply Mode -20 ~55 ;20%RH~90%RH Automatic shift Prohibited <40A/m <1V/m About 0.5 second Detector: 50ma Max. Grounding wire through Detector centre bore IP65 Avoid rain and water logging External power supply (Equipped by user) 4

IV. Detector Structure 1. Grounding wire perforation size: 60mm 30mm. 2. LCD displayer. 3. Up and down cover connecting screws (6 pieces). 4. Install screw holes. 5. Button and the indicator light. 6. Power supply, RS485 communication interface. Power Supply Indicator Light Working indication when power supply switches on. Alarm Indicator Light Alarm light switches on when measured value is beyond pre-set critical value. SET Key Enter setup Up and Down Arrow Key Press SET key to enter the alarm setting, press up and down arrow key to set value. Enter Key After setting up alarm critical value, press ENTER key to ensure saving. Note: ETCR2800B mode without LCD display and press key function. V. Network Structure 1. Independent Installation and Use. ETCR2800C can be installed and used independently, also can develop system software on their own according to offered RS485 communication protocol, organizes a network monitor. LCD shows measured value directly, also sets up Detector s alarm critical value, and possess audible and visual alarming function. When independent installation it can use 2 batteries instead of power supply, or use solar cell panel to charge batteries, batteries need placing in the protection box. 2. Reference of Network Organization. Users can develop system software on their own according to offered communication protocol, organize wired network, as the picture below. Cable Network System 5 Wireless Network System

VI. The Principle and Application of Detection 1. Testing Principle. Non-Contact Grounding Resistance Online Detector s fundamental is measuring return circuit resistance. firstly Sensor send out a drive pulse signal to be measured ground return circuit, then measured ground return circuit responses a pulse electromotive force E, under the influence of electromotive force E there will generate current I in the be measured ground return circuit. Sensor measures E and I, and immediately gets resistance of be measured ground return circuit through the formula: R=E/I. 2. Return Circuit Resistance Definition. As picture: return circuit is a composite value includes A spot grounding resistance, grounding down lead metallic conductor s resistance, metal overhead line s resistance, connection resistance(contact resistance)between grounding down lead and metal overhead line, B spot grounding resistance. For the formative above-mentioned return circuit s grounding system, Detector can be installed directly for monitoring, if the grounding system not form a return circuit, it need adding auxiliary grounding electrode to form a return circuit, further install the Detector, see the after-mentioned single point grounding system. If the Detector measured out return circuit s composite value of grounding network A and grounding network B is 5.0Ω, that is: R A +R B +R C + R D =5.0Ω(R C and R D respectively represent resistance of metal overhead line and grounding down lead ), actual grounding resistance value of grounding network A and grounding network B s in parallel resistances less than or equal to 2.5Ω, accordingly judge actual grounding resistance value of grounding network A and grounding network B parallel connection whether qualified. If grounding network A and grounding network B s in parallel resistances less than engineering standard required value, so grounding network A and grounding network B are all qualified. 3. Metal Return Circuit Connection Resistance Testing. If grounding network A and grounding network B up and down are connected together on the ground, then Detector measures out metal return circuit resistance s value is very small general speaking, only few of an Ohm, this is the connection resistance of metal return circuit, namely equipotential resistance, isn t grounding resistance. Therefore the Detector is also convenient to test metal return circuit s connection resistance. In the large-scale grounding grid, such as converting station ground connection, oil depot ground connection, building construction ground connection and so on, they are all an integral large-scale grounding grid under the ground, meanwhile there are many grounding down lead extends to the ground, and connects the other on the ground, as the following picture. To such large-scale grounding grid, its grounding grid s maximum diagonal distance is about a few hundred meters to thousands of meters, testing its grounding resistance is very difficult and troublesome. If it exist unqualified grounding resistance, that problem is appearing at the connection position of grounding down lead and grounding grid (direction of arrow of the welding position in the picture), engineering reform is to excavate grounding down lead s position, then again weld grounding down lead. Actually it s 6

impossible to reform the whole grounding grid, or the whole grounding grid and surface facilities need to pull down and rebuild, this is impossible. Therefore, for the large-scale grounding grid, we can install Detector on the primary grounding down lead and secondary grounding down lead to monitor connection status between the grounding down lead and the grounding grid, judge the grounding down lead s grounding conditions by testing metal return circuit connection resistance. 4. Single Point Grounding System. If grounding network A and grounding network B is without overhead line, and doesn t connect together on the ground, then grounding network A and grounding network B can regard as standalone single point grounding connection. Detector cannot test single point grounding system s grounding resistance directly. This moment it needs adding one or more auxiliary grounding electrode, to form multipoint return circuit, then to install Detector. In the small range, if there are two or more single point grounding system, it can use metallic conductor to connect all single point grounding system s grounding down lead together on the ground, to form a return circuit, then install the Detector to monitor. 5. Application. (1). Power Transmission System Pole Ground Connection. It forms multipoint grounding system through overhead ground wire connection; test conveniently, its equivalent circuit as the following picture on the right. illustration:r1 is predicted grounding resistance, R0 is the equivalent resistance of all the other pole s grounding resistance parallel connection, that is R 0 =R 2 R 3 R 4 R n, if the greater n is (the more grounded junction), the closer R 0 gets to 0,far smaller than R 1, from engineering point of view, R 0 =0,so, the data Detector receives should be R 1 s value. (2). Underground Mine Power Transformation Ground Connection. respectively,primary grounding electrode R,R 1 ~R 3 R n is a independent grounding body under the ground, don t connect together, are multipoint grounding system, convenient to test. Detector is installed on the primary grounding electrode, the Detector s indication is R r =R+R 1 R 2 R 3 R n. If the more part grounded junctions are, so R 1 R 2 R 3 R n 0,then R r =R. It s the four-code cable in the picture, one code is ground lead among it, all the devices and part grounding connection are connected to be a network by cable grounding connection, dotted line is bare copper wire of grounding connection. 7

(3). Generator Room and Launch Tower Grounding Connection. Generator Room and Launch Tower is independent outdoors generally, connect both together to form second return circuit, then install detector, as the picture below. (4). Construction Grounding Connection. If R 1 ~R 6 R n is a independent grounding body under the ground, don t connect together, are multipoint grounding system, convenient to test grounding resistance. If R 1 ~R 6 R n are connected together under the ground, for the single point grounding system, testing grounding resistance in accordance with single point grounding system, direct installation test return circuit resistance, can judge grounding connection condition. For the large-scale construction grounding grid, it is to monitor its equipotential value of grounding condition between grounding down lead and grounding network. If problems occur, it would be located at the connection point between grounding down lead and grounding network, and judging that whether its equipotential value qualified or not. (5).Oil Storage Tank s loading and Unloading Point Grounding Connection. 8

VII. Wiring Instructions Wire Color Introductions Red/Brown Power Supply Anode Black Power Supply Cathode(GND) Blue RS485 Signal Positive Electrode Grey RS485 Signal Negative Electrode White Signal grounding electrode can short connect GND. When organize a network, it needs connecting Detector in accordance with wire color. VIII. Install Caution Special Explanation: only if it forms a return circuit grounding connection system, it could directly install and use. Otherwise, firstly it needs to set up an auxiliary grounding connection nearby to form a return circuit, then to install the Detector. 1. Install the Detector to grounding down lead, and grounding down lead needs to unbuckle buckle, convenient for product maintenance latterly. Installation must be waterproof, rainproof, anti-theft and breakage-proof and so on in the open air. 2. Notice direction, try to be vertical and wire port downwards. 3. Notice height. 4. Deploy power supply and communication wire on the basis of field and distance. 5. Power supply wire s polarities connect properly or Detector doesn t work. IX. Power Supply Way Choice 1. AC adapter converts power supply s 220V AC into 6-9V DC, which can supply Detector. 2. 2 pieces standby batteries for alternate use. 3. As the picture below, solar cell panel supply is suitable for the places where can't get electricity. Solar cell panel s anode and batteries anode needs a fast recovery rectifier forward connection in series (as IN5817), when using ETCR2800C is convenient. X. Basic Equipment Detector Connector Wire Packing Box User's Manual, Warranty Manual, Certification 1Set 1PCS 1 Set 1 Set 9

10

Manufactured by ETCR Electronic Technology Company Address: F-3F, No.4 Pengshang Zhifu Road, Jiahe, Baiyun District, Guangzhou, Guangdong, China Post Code: 510440 Tel: (86-20)62199556 62199554 Fax: (86-20)62199550 E-mail: info@etcr.cc Website: www.etcr.cc 11