Hot Issues in Fire Engineering 28 February 2012

Similar documents
NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

NECESSITY OF CARRYING OUT FULL-SCALE BURNING TESTS FOR POST-FLASHOVER RETAIL SHOP FIRES

NECESSITY OF IN-DEPTH EVALUATION OF LONG-THROW SPRINKLER INSTALLATION AT TALL ATRIA STORING HIGH AMOUNTS OF COMBUSTIBLES

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Hot Issues in Fire Engineering 12 March 2013

Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

FULL-SCALE BURNING TESTS FOR RETAIL SHOP FIRES: PRELIMINARY STUDIES

ASPECTS OF FIRE SAFETY IN ULTRA HIGHRISE BUILDINGS

PRELIMINARY STUDIES ON MECHANICAL SMOKE EXHAUSTS IN LARGE SPACE BUILDING FIRES

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

IFireSS International Fire Safety Symposium Coimbra, Portugal, 20 th -22 nd April 2015

Experimental Room Fire Studies with Perforated Suspended Ceiling

Comment on Hawker Stall Fires

Simulation of Full-scale Smoke Control in Atrium

On Estimating Heat Release Rate for a Design Fire in Sprinkler Protected Area

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

Hot Issues in Fire Engineering July 2014

ASSESSING FIRE SAFETY PROVISIONS FOR SATISFYING GREEN OR SUSTAINABLE BUILDING DESIGN CRITERIA: PRELIMINARY SUGGESTIONS

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

Simulation of Emergency Evacuation in the Arrival Hall of a Crowded Airport

SCALE MODEL STUDIES ON SMOKE MOVEMENT IN INCLINED TUNNEL WITH LONGITUDINAL VENTILATION AND SMOKE BARRIERS

OBSERVATION ON THE TWO RECENT BUS FIRES AND PRELIMINARY RECOMMENDATIONS TO PROVIDE FIRE SAFETY

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

PRELIMINARY EXPERIMENTAL STUDY OF DOUBLE-SKINNED FAÇADE

Experimental Study on the Characteristics of Temperature Field of Fire Room

and vent height on mechanical smoke exhaust efficiency

CFD Analysis of Fire Characteristics on Subway Junction Station

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

SHOULD SMOKE MANAGEMENT SYSTEM BE PROVIDED IN KARAOKE ESTABLISHMENTS?

An experimental study of the impact of tunnel suppression on tunnel ventilation

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Yunyong P. Utiskul, Ph.D., P.E., CFEI

REVIEW ON WATER MIST FIRE SUPPRESSION SYSTEM

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

SURVEY ON FIRE SERVICE INSTALLATIONS FOR OFFICE BUILDINGS IN HONG KONG

Evacuation Hazards in Crowded Subway Stations

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Studies of Cooling Effects of Sprinkler Spray on Smoke Layer

Factors Affecting Efficiency of Water Mist Suppression of Solid Combustible Fires in Open Environment

Considerations in the Design of Smoke Management Systems for Atriums

A NETWORK MODEL OF SIMULATING SMOKE MOVEMENT IN BUILDINGS

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Sprinklers Modeling for Tunnel Road Fire Fighting

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Experimental Study on Response Sensitivity of Smoke Detectors in High Flow Velocity

Research on Mobile Water Spray Device Reducing the Temperature of Metro Fire

A Monte Carlo Approach for the Design of Thermal Fire Detection System

Tunnel Fire Dynamics and Evacuation Simulations

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

Predictions of Railcar Heat Release Rates

Large-scale fire test for interior materials of the Korean high speed train

A Study on the Fire Safety Issues for Large Window Openings in Supertall Residential Buildings in Hong Kong

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

First Revision No. 6-NFPA [ Section No. 2.2 ]

CFD Model of a Specific Fire Scenario

Test One: The Uncontrolled Compartment Fire

Experimental Study on the Interaction of Water Mists with Fires in the Confined Space

Laboratory fire experiments with a 1/3 train carriage mockup

Examination of Performance of Water Mist Fire Suppression Systems under Ventilation Conditions

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

The Science Behind Water Mist Protection of Typical Building Hazards

PRELIMINARY VIEWS ON IMPLEMENTING ENGINEERING PERFORMANCE-BASED FIRE CODES IN HONG KONG: WHAT SHOULD BE DONE?

A Brief on Performance- Based Design for Building Fire Safety

Smoke movement for sprinklered fires. Lougheed, G.D.; McCartney, C.; Taber, B.C.

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

Performance-based Fire Design of Air-supported Membrane Coal Storage Shed

RECENT EXPERIMENTAL STUDIES ON BLOCKING HEAT AND SMOKE BY A WATER CURTAIN

CFD Simulation of the Water Mist Effect on Fire

TECHNICAL TRADE-OFFS USING FIXED FIRE FIGHTING SYSTEMS

Fire Hazard Analysis of Technical Area 53 Building 1

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

FIRE SAFETY ENGINEERING AND POTENTIAL APPLICATION OF FIRE MODELS

Suppression Effect of Water Vapor on Flammability Limits of Hydrocarbon Fuels - A Study on Fire Suppression by Water Mist -

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

Cabins and Islands: A Fire Protection Strategy for an International Airport Terminal Building

Gothenburg dance hall, Sweden, 1998

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

A Fire Safety Ranking System for Karaoke Establishments in Hong Kong

WATER MIST CONVENTION AND EXHIBITION

Crossrail Project. Infrastructure design and construction Volume 5. Edited by Professor Rhys Vaughan Williams and Mike Black

2012 International Symposium on Safety Science and Technology Investigation on compressed air foams fire-extinguishing model for oil pan fire

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Fire Conference Total Fire Safety Concept

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

FIRE ASPECTS ON LIFT SHAFTS USED FOR EVACUATION IN SUPERTALL BUILDINGS

Case Study for Performance-Based Design in Hong Kong

Heat and Smoke Release of a Ceiling-Installed Speaker

SUPPRESS FLASHOVER OF GLASS-REINFORCED POLYESTER FIRE WITH WATER MIST INSIDE ISO 9705 ROOM

Max Fire Box Users Guide

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

The first tunnel fire. Benefits of fire

Fire Safety Management System in Modern High-rise Buildings - Hong Kong Perspective

ABSTRACT 1 INTRODUCTION

Carbon Monoxide Poisoning

Fire Test Evaluation using the Kerosene and Aviation Fuel

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Transcription:

Hot Issues in Fire Engineering 28 February 2012 A Note on Cabin Fire Design for Protecting Large Halls W.K. Chow Research Centre for Fire Engineering, Department of Building Services Engineering The Hong Kong Polytechnic University, Hong Kong, China Many big public transport terminals in the Far East including the airport and many subway stations [1] in Hong Kong are not fully covered by fire suppression and smoke exhaust systems. Only the cabin concept [2-4] was used in many big halls, but mostly protecting some areas for retail and catering. Apart from the hard efforts of the author and his students [5-19], very few systematic experimental studies were reported to demonstrate that the design [20-23] can control the heat release rate to a certain value, nor smoke would not spread to the entire big hall. Heat removed by operating the sprinklers in a cabin was not measured, but only presumed to be controlled within a small value such as 2 MW. Almost no full-scale burning tests appeared in the literature to demonstrate that the cabin concept would work as expected [24], particularly in the Far East, where social responsibility and education of citizens are very different from those in advanced countries. Taking the Hong Kong airport terminal as an example, it was observed that combustibles (apart from luggage) are always placed outside the cabin! Research results compiled in advanced countries might not be applicable to such developing areas [7]. Strong justification with full-scale burning tests is needed on watching flashover in a cabin fire as proposed [25,26]. A full cabin is required [1-3] to have a sprinkler system to control the fire, and a smoke exhaust system to remove smoke. Preliminary studies showed that burning a typical newsstand [8,18] would give heat release rates up to 8 MW. Values higher than 8 MW are expected if large amounts of combustibles including wine are stored. Therefore, it is difficult to convince the public that the heat release rate in a retail shop fire in a cabin can be controlled at low values such as 2 MW even with sprinklers [24]. A long-term research programme with very limited resources [1,27,28] on cabin fires was worked out by the author for over ten years, in collaboration with several research groups in China. The project started with theoretical analysis on the fire environment inside a bare cabin, possibility of onsetting flashover, and shop spill plume. Experiments on such bare cabin fires and smoke spilling out to the hall were then carried out to understand the possible hazards. The performance of sprinklers and smoke exhaust systems in a cabin of length 3.5 m, 1

width 4 m and height 3 m was studied. The study was only on a 0.6 m by 0.6 m wood crib fire of height 0.4 m ignited over a pool of size 0.25 m by 0.25 m with mass of fuel 0.2 kg. The steady heat release rate of the wood crib was measured experimentally in an oxygen consumption room calorimeter to be 650 kw over 300 s. The heat release rate of two wood cribs placed within 0.3 m was up to 1.3 MW. The following were observed in those preliminary tests: Air temperature inside a bare cabin fire would increase quickly upon burning the crib. The ceiling temperature could be up to 600 o C when two such wood cribs were burnt. Mechanical smoke exhaust system would control smoke in the cabin. However, smoke cannot be controlled, after operating the sprinkler, because of disturbing the stability. Large quantity of hot smoke was then observed to be spilling out to the hall outside. Therefore, a smoke exhaust system should be provided in the entire hall to keep smoke at high level. For cabins not completely closed, known as open cabin in Hong Kong, air supply might lead to flashover in the cabin. The cabin itself would then become a big burning object. Therefore, the outside hall should have a fire suppression system. It was observed that sprinklers operating under normal design conditions [29] could not extinguish such a small wood crib fire with low heat release rates of 1.3 MW. All combustibles inside the cabin were burnt out even with the sprinklers operating. Those preliminary tests suggested that sprinklers might not be able to control a cabin fire if the combustible content inside the cabin is not controlled. Those retail shops storing many combustibles should be watched carefully. In particular, open cabins with only sprinklers inside but no fire suppression system in the outside hall should be reviewed carefully. This is because flashover inside a small cabin can be onsetted easily to give a big fire! A normal sprinkler system using design parameters specified in the local fire code [29] might not be adequate. It cannot control fires with two wood cribs of 1.3 MW. Note that experimental data by the Swedish suggested that burning potato crisps bags [30] would give a heat release rate curve following a fast t 2 -fire up to 6 MW quickly. Such a big starting fire would ignite adjacent combustible items (observed many times, apart from luggage) to give a much bigger fire. An alternative suppression system, such as a water mist system, should be provided inside the cabin if the fire load inside is not limited to 2

very low values. Full-scale burning tests with such a water suppression system should be carried out to justify whether such big fires can be suppressed. Otherwise, appropriate fire suppression systems should be installed in the entire hall. As demonstrated in the preliminary tests on small wood crib fires and typical newsstand fires, water mist discharged from a high speed water fog nozzle might be able to control the fire if designed properly. Anyway, the above are just preliminary results at two remote sites in China with limited funding. It is difficult to say that the cabin concept is safe as assumed in advanced countries [2-4,24] in protecting against the big hall, far too many problems were identified while using the cabin concept in the developing countries. Further systematic research should be carried out to demonstrate that the cabin concept would work for big public transport terminals in the Far East. In particular, full-scale fire tests under realistic big fires should be carried out in big terminals. The heat release rates of burning bigger retail cabins should be measured [12]. If the cabin design is demonstrated to have difficulties in functioning as expected in limiting the fire to 2 MW and unable to avoid spreading smoke out to the halls, workable fire suppression and smoke exhaust systems must be installed as soon as possible to protect the entire hall. Most of the public transport terminals in airports and subway stations in the Far East are very busy. Any disturbance to normal operation of the terminals will lead to disasters. Difficulty in locating the fire source encountered in the Chek Lap Kok airport fire was a good lesson to learn [31]. More importantly, improper fire safety design would also affect the firefighting and rescue strategies, and bring ill effects to the safety and health of firemen. They took several hours to locate the burning source as experienced at the Hong Kong airport fire in April 1998! With the possibility of developing new phases of the airport, it is the right time to review the fire safety strategy proposed over 20 years ago [2-4]. Further systematic experimental studies [1,5-19,27,28] must be carried out, not just relying on doing one or two demonstration tests with small fires in a few days. References 1. W.K. Chow, Several points to note in performance-based design for fire safety provisions in Hong Kong, The National Symposium on Fire Safety Science and Engineering, 14-16 October 2010, Beijing, China (2010). 3

2. M. Law, Fire and smoke models Their use on the design of some large buildings, ASHRAE Transactions, Vol. 96, No. 1, p. 963-971 (1990). 3. C.M. Lam, Fire safety strategies for the new Chek Lap Kok International Airport, Conference Proceedings of Asiaflam 95, 15-16 March 1995, Hong Kong, p. 63-68 (1995). 4. P. Bressington, Railway link to Chek Lap Kok, Fire East 95 Conference and Exhibition, Hong Kong, 7 November 1995, 5.1-5.8 (1995). 5. W.K. Chow, On the cabin fire safety design concept in the new Hong Kong airport terminal building, Journal of Fire Sciences, Vol. 15, No. 4, p. 404-423 (1997). 6. W.K. Chow A preliminary study on the fire protection aspects of the new airport terminal building, Journal of Applied Fire Science, Vol. 6, No. 4, p. 327-338 (1997). 7. W.K. Chow, Gaowan Zou, Hui Dong and Ye Gao, Necessity of carrying out full-scale burning tests for post-flashover retail shop fires, International Journal on Engineering Performance-Based Fire Codes, Vol. 5, No. 1, p. 20-27 (2003). 8. W.K. Chow, Y. Gao, H. Dong, G.W. Zou and L. Meng, Will water mist extinguish a liquid fire rapidly?, Architectural Science Review, Vol. 46, No. 2, p. 139-144 (2003). 9. Q. Kui, A study on enclosure fires with mechanical ventilation system, PhD thesis, Department of Building Services Engineering, The Kong Kong Polytechnic University, Hong Kong (2003). 10. W.K. Chow, Smoke control for retail shops with cabin design, ASHRAE Transactions, Vol. 110, Part 2, p. 417-423 (2004). 11. C.L. Shi, Y.Z. Li, R. Huo, B. Yao, W.K. Chow and N.K. Fong, Mechanical smoke exhaust for small retail shop fires, Proceedings of the 2004 ASME International Mechanical Engineering Congress (IMECE04), Anaheim, California, Anaheim Hilton, USA, 13-20 November 2004, Paper IMECE2004-59301 (2004). 12. W.K. Chow, International Journal on Engineering Performance-Based Fire Codes - Special Issue on full-scale burning tests, Vol. 6, No. 3 (2004). 13. C.L. Shi, Y.Z. Li, R. Huo, B. Yao, W.K. Chow and N.K. Fong, Mechanical smoke exhaust for small retailing shop fires, International Journal of Thermal Sciences, Vol. 44, No. 2, p. 477-490 (2005). 14. R. Huo, X.H. Jin, W.K. Chow and N.K. Fong, Experimental studies on natural smoke filling in atrium due to a shop fire, Building and Environment, Vol. 40, No. 9, p. 1185-1193 (2005). 15. L. Yi, Study on smoke movement and management in atrium buildings, PhD thesis, University of Science and Technology of China, Hefei, Anhui, China (2005). 16. C.L. Shi, Study on enclosure fire growth and smoke movement in large space buildings, PhD thesis, University of Science and Technology of China, Hefei, Anhui, China (2005). 4

17. W.K. Chow, Fire hazard assessment of combustibles in big terminals, International Journal of Risk Assessment and Management, Vol. 5, No. 1, p. 66-75 (2005). 18. W.K. Chow, Assessment on fire hazard in a small news agent in transport terminal halls, ASCE - Journal of Architectural Engineering, Vol. 11, No. 1, March, p. 35-38 (2005). 19. Y.H. You, Studies on cabin fire and smoke under mechanical exhaust and sprinkler in large space building, PhD thesis, University of Science and Technology of China, Hefei, Anhui, China (2007). 20. M. Law, On the Cabins fire safety design concept in the new Hong Kong airport terminal building, Journal of Fire Sciences, Vol. 16, No. 3, p. 149-150 (1998). 21. P. Beever, On the Cabins fire safety design concept in the new Hong Kong airport terminal building, Journal of Fire Sciences, Vol. 16, No. 3, p. 151-158 (1998). 22. J.C. Jones, A contribution to the discussion of the cabins fire safety design concept, Journal of Fire Sciences, Vol. 16, No. 6, p. 410-413 (1998). 23. J.C. Jones, Rates of radiative and convective heat transfer in a cabin fire, Journal of Fire Sciences, Vol. 17, No. 2, p. 103-110 (1999). 24. W.C. Yan and M.C. Luo, Fire safety design for 2008 Olympic Halls, Fire and Disaster Prevention, p. 70 (2007) - In Chinese. 25. J.C. Jones, Flashover in enclosure fires, International Fire Protection, Issue 22, May, p. 84-87 (2005). http://www.ifpmag.com/ 26. J.C. Jones, Comment on fire load densities, International Journal on Engineering Performance-based Fire Codes, Vol. 10, No. 3, p. 75 (2011). 27. W.K. Chow, Performance-based design on fire safety provisions in Hong Kong, 2011 SFPE Annual Meeting: Professional Development Conference and Exposition, 24-25 October 2011, Portland, OR, USA (2011). 28. W.K. Chow, A long-term research programme on studying cabin fires, Invited Speaker, Fire Asia 2006 Best Practices in Life Safety, 15-17 February 2006, Hong Kong Convention and Exhibition Centre (HKCEC), Hong Kong (2006). 29. Fire Services Department, Codes of Practice for Minimum Fire Service Installations and Equipment and Inspection, Testing and Maintenance of Installations and Equipment, Government Printer, Hong Kong Special Administrative Region (1998). 30. M. Arvidson, Potato crisps and cheese nibbles burn fiercely, Brand Posten, No. 32, p. 10-11 (2005). 31. Tin Tin Daily News, No. 3 alarm fire at the new Hong Kong International Airport passenger terminal, Hong Kong, 30 April (1998). AHotFireIssueCab8 5