VICTRIX Superior kw Export VICTRIX Superior kw X Export

Similar documents
1 VICTRIX ZEUS Superior kw I features

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

SPECIFICATIONS - NIKE

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

MAIOR EOLO 4 E. Instantaneous wall-hung boilers, sealed-room with "Aqua Celeris" system MAIOR EOLO 4 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

Condensing, pre-mixed, wall-hung gas boilers with water tank

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

ENERGY TOP. Condensing boiler solutions

HEAT PUMPS MAGIS COMBO

C Tahiti. condensing

Power X High Power Condensing Wall-Hung Boilers

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Power X High Power Condensing Wall-Hung Boilers

white blue cobalt bordeaux light oak (rovere)

The iqe Boiler Range. Combination and System T Boilers.

Ciao Green Condensing Wall-Hung Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Seradens Super Seradens Super Plus

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

* ENG* Instruction and warning booklet MINI EOLO 28 3E

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

WALL-HUNG GAS CONDENSING BOILERS MCR-P 24/28 BIC. HOMOLOGATION B 23P - C 13x - C 33x - C 93x -C 53 - C 43x - C 83x *

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

FORMENTERA KC - KRB - KR

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

Flue gas condensation...

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

TAHITI CONDENSING KR 55 - KR 85

ZEUS Superior. ZEUS 21 Superior ZEUS 24 Superior ZEUS 27 Superior. Manual service centrala termica murala Immergas zeus superior cu boiler

4FLOOR-STANDING GAS CONDENSING BOILERS

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

* ENG* Instruction and recommendation booklet MINI EOLO X 24 3 E

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

VELA COMPACT INSTALLATION USE AND MAINTENANCE

ARIES DUAL MAINTENANCE MADE IN ITALY IST 04 C

Exclusive Green E Condensing Wall-Hung Boilers

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

CAST IRON ATMOSPHERIC BOILERS

The mechatronics of EVE 05

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Ideasandformsinevolution

RinNOVA. User manual and installation instructions

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

ACCUMULATION OF EUROPEAN CLASS

CAESAR 14 3 E Super CAESAR 17 3 E

Capri B Cast iron combination oil-fired boiler with water tank

ZENA PLUS EASYLIFE WALL-HUNG GAS BOILERS

RIELLO 40 GS/M SERIES

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

Mynute Green Condensing Wall-Hung Boilers

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

HEAT ONLY & COMBI BOILER

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

MINORCA KC - KR - KRB 24

MAINTENANCE AND SERVICE GUIDE

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

A/23 MFFI - A/27 MFFI

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Technical Documentation

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

NANEO EMC-M WALL-HUNG GAS CONDENSING BOILERS

DIDACTIC MANUAL FAMILY: GROUP: MODELS: VERSIONS: CODICE: AST 14C157/00. Wall-hung boilers

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Sirius FS. Working towards a cleaner future

HEAT PUMPS MAGIS PRO ErP

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

CITY OPEN - CITY BOX from 25 to 35 kw

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Bithermal Wall-hung boiler with integrated heat exchanger

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HFM

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Gas heaters and convectors ROBUR

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

8FUEL OIL CONDENSING BOILERS

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

COND SYSTEM Condensation boiler outdoor / indoor combined with indoor heaters

Rinnova Cond X. User manual and installation instructions

ARES Tec HIGH OUTPUT MODULAR CONDENSING BOILER RANGE

Transcription:

Wall-hung condensing VICTRIX Superior kw is the instantaneous sealed chamber wallhung boiler with power of 32 kw which, thanks to condensation technology, is characterised for its high efficiency and guarantees extremely low pollutant emissions (the boiler belongs to the most environment-friendly class envisioned by European Standards - class 5). The boiler stands out due to the "Aqua Celeris" system, which drastically reduces stand-by times regarding the distribution of domestic hot water and also due to the new hydraulic unit that guarantees high efficiency, thanks to the new electronicallycontrolled flow rate adjuster: this guarantees a large production of domestic hot water at the temperature desired by the user. The new elegant Schumann design, together with its compact size, make this boiler the ideal solution for integration in kitchen wall units and it also fits in with room furnishings. The boiler is also typeapproved for functioning outdoors in partially protected places (standard anti-freeze protection -3 C, with optional kit for -15 C). The new microprocessor-controlled electronics allows optimum control of temperatures both in heating and domestic hot water production modes and it may also be coupled to the exclusive Super CAR and to the external probe (both optional features), which allow to manage, control and program the boiler at a distance with extreme simplicity, thus optimising functioning through climatic heat adjustment. 1 VICTRIX Superior kw FEATURES Condensing type wall-hung sealed chamber fan assisted premix boiler for heating and production of domestic hot water with maximum useful heat output of 32 kw (27,520 kcal/h) with high efficiency and forced circulation. By varying the type of installation the boiler classification also varies. OUTDOOR INSTALLATION (in a partially protected place): Appliance type C with direct air intake- if installed using a flue terminal and the (optional) mandatory upper cover kit, also eliminating a sealed chamber intake cap. Appliance type C 13 / C 33 / C 83 - if installed using the vertical or horizontal concentric kits (cover kit recommended but not mandatory) or the Ø 80/80 separator kit without using the upper cover kit. INDOOR INSTALLATION: Appliance type C 13 / C 33 / C 43 / C 53 / C 83 - if installed using the vertical or horizontal concentric kits or the Ø 80/80 separator kit. Appliance type B 23 - if installed using a flue kit and the (optional) mandatory upper cover kit, also eliminating a sealed chamber intake cap. The boiler comprises: total premix combustion system with steel cylindrical multigas burner, complete with ignition electrode and ionisation control electrode; pneumatic gas valve with double shutter; primary gas/water heat exchanger with stainless steel coil; stainless steel combustion chamber insulated internally using ceramic panels; fan for the evacuation of fumes at an electronically variable speed; circuit for the elimination of condensate including siphon and flexible drain pipe; 22 stainless steel plate secondary water/water heat exchanger for the production of domestic hot water; "Aqua Celeris" system made up from one mini storage tank inserted into the primary circuit and kept at temperature by a modulating electrical resistance; hydraulic unit comprising a 3-way electric valve, an adjustable-speed circulating pump with built-in air separator, adjustable by-pass, absolute pressure switch for the primary circuit, 3 bar safety valve for the primary circuit, a system draining fitting and filling valve; domestic hot water flow rate adjuster including domestic hot water inlet probe and domestic hot water flow meter to check circulating flow rate; 7.5 litre expansion vessel system with diaphragm (real 6.8) with pre-load at 1.0 bar and manometer; water overheating safety thermostat and fumes overheating thermostat; control panel with Stand-by/On button, functioning mode button (Summer/Winter), Aqua Celeris system activation button, Reset/exit programming menu button, programming menu entry/data confirmation button, central heating system temperature adjustment selector, domestic hot water temperature adjustment selector. microprocessor driven P.C.B. with continuous flame modulation with 2 sensors for central heating (flow and return) and 2 sensors for domestic hot water with P.I.D. control and modulation range from 6.4 to 32 kw: central heating temperature selection range 25-50 C or 25-85 C (standard setting); electronic ignition with ionisation control; self-diagnostics system with digital display of the temperature, operating status and anomalies by means of a back-lit display; setting of the boiler functioning parameters using buttons and selectors with display of status and operating mode by means of a back-lit display; ignition retarder in central heating mode, anti-freeze protection system (up to -3 C), circulator anti-block device function, post-ventilation function, chimney sweep function, circulator functioning mode selection; preparation for connection with the Super CAR, the CAR, Chronothermostat, external probe and the zones control unit; IPX5D electrical insulation level. possibility of coupling to the system for ducting of existing flues Ø 60 mm and Ø 80 mm. Supplied with sample points for combustion analysis, lower protection grid, connection group with depth-adjustable fittings gas interception and domestic cold water cocks. Category II 2H3+ appliance, functions with natural and L.P.G. gas. CE Mark. It is available in the model: VICTRIX Superior 32 kw Export code 3.019103 NOTA BENE: for correct installation of the boiler the Immergas "Green Range" air intake/fumes exhaust kit must be used. 1

VICTRIX Superior kw X is the wall-hung condensing boiler for room central heating only with 32 kw power which, thanks to condensation technology is distinguished for its particularly high efficiency. The innovative total premix combustion system and the special environment-friendly burner mean it can run on natural or LPG gas, guaranteeing extremely low pollutant emissions (the boiler belongs to the most environment-friendly class envisioned by European Standards - class 5). Thanks to a particular kit (optional) the boiler can be connected to a separate Immergas 80, 105, 120 or 200 litre Storage Tank Unit, which guarantees a large production of domestic hot water. This is especially ideal for homes with more than one bathroom and where great amounts of water are required quickly. The boiler is type-approved also for functioning outdoors in partially protected places (standard anti-freeze protection -3 C, with optional kit for -15 C). The new microprocessor controlled electronics allows optimum control of temperatures both in central heating and domestic hot water production modes (if the optional storage tank unit kit is installed) and it may also be coupled to the exclusive Super CAR and to the external probe (both optional features), which allow to manage, control and program the boiler at a distance with extreme simplicity, thus optimising functioning through climatic heat adjustment. 2 VICTRIX Superior 32 kw X FEATURES Condensing type wall-hung sealed chamber fan assisted premix boiler for central heating with maximum useful heat output of 32 kw (27.520 kcal/h) with high efficiency and forced circulation. Thanks to a particular kit (optional) it can be coupled to a separate 80, 105, 120 and 200 litre Storage Tank Unit for the production of domestic hot water. By varying the type of installation the boiler classification also varies. OUTDOOR INSTALLATION (in a partially protected place): Appliance type C with direct air intake - if installed using a flue terminal and the (optional) mandatory upper cover kit, also eliminating a sealed chamber intake cap. Appliance type C 13 / C 33 / C 83 -if installed using the vertical or horizontal concentric kits (cover kit recommended but not mandatory) or the Ø 80/80 separator kit without using the upper cover kit. INDOOR INSTALLATION: Appliance type C 13 / C 33 / C 43 / C 53 / C 83 - if installed using the vertical or horizontal concentric kits or the Ø 80/80 separator kit. Appliance type B 23 - if installed using a flue kit and the (optional) mandatory upper cover kit, also eliminating a sealed chamber intake cap. The boiler comprises: total premix combustion system with steel cylindrical multigas burner, complete with ignition electrode and ionisation control electrode; pneumatic gas valve with double shutter; primary gas/water heat exchanger with stainless steel coil; stainless steel combustion chamber insulated internally using ceramic panels; fan for the evacuation of fumes at an electronically variable speed; circuit for the elimination of condensate including siphon and flexible drain pipe; hydraulic unit comprising an adjustable-speed circulating pump with built-in air separator, adjustable by-pass,, absolute pressure switch for the primary circuit, 3 bar safety valve for the primary circuit, a system draining fitting, ball valve for system filling; 8.0 litre expansion vessel system with diaphragm (real 8.0) with pre-load at 1.0 bar and manometer water overheating safety thermostat and fumes overheating thermostat; control panel with Stand-by/On button, functioning mode button (Summer/Winter), domestic hot water priory temporary inhibition button (if the Storage Tank Unit coupling kit is used), Reset/exit programming menu button, programming menu entry/data confirmation button, central heating system temperature adjustment selector, domestic hot water temperature adjustment selector (if the Storage Tank Unit coupling kit is used). microprocessor driven P.C.B. with continuous flame modulation with 2 sensors for central heating (flow and return) with P.I.D. control and modulation range from 6.4 to 32 kw: central heating temperature selection range 25-50 C or 25-85 C (standard setting); electronic ignition with ionisation control; self-diagnostics system with digital display of the operating status and anomalies by means of a back-lit display; setting of the boiler functioning parameters using buttons and selectors with display of status and operating mode by means of a back-lit display; ignition retarder in central heating mode, anti-freeze protection system (up to -3 C), circulator anti-block device function, postventilation function, chimney sweep function, circulator functioning mode selection; preparation for connection with the Super CAR, the CAR, chronothermostat, external probe and the zones control unit; IPX5D electrical insulation level. possibility of coupling to the system for ducting of existing flues Ø 60 mm and Ø 80 mm. Supplied with sample points for combustion analysis, lower protection grid, connection group with depth-adjustable fittings and gas interception cock. Category II 2H3+ appliance, functions with natural and L.P.G. gas. CE Mark. It is available in the model: VICTRIX Superior 32 kw X Export code 3.019104 NOTA BENE: for correct installation of the boiler the Immergas "Green Range" air intake/fumes exhaust kit must be used. 2

3 VICTRIX Superior kw MAIN COMPONENTS KEY: 1 - D.H.W. flow rate regulator 2 - Condensate drain tap 3 - D.H.W. probe 4 - D.H.W. flow meter 5 - Fan 6 - Gas nozzle 7 - Gas valve 8 - Venturi 9 - Detection electrode 10 - Flue safety thermostat 11 - Air intake pipe 12 - Condensation module 13 - Negative signal pressure point 14 - Positive signal pressure point 15 - Sample points (air A) - (fumes F) 16 - Manual vent valve 17 - Burner 18 - Ignition electrode 19 - Flow probe 20 - Safety thermostat 21 - Aqua Celeris 22 - Automatic vent valve 23 - System expansion vessel 24 - Return probe 25 - Boiler pump 26 - System pressure switch 27 - D.H.W. heat exchanger 28-3 bar safety valve 29-3-way valve (motorised) 30 - System draining valve 31 - D.H.W. inlet probe 32 - System filling valve 3

4 VICTRIX Superior kw X MAIN COMPONENTS KEY: 1 - Condensate drain tap 2 - Fan 3 - Gas nozzle 4 - Gas valve 5 - Venturi 6 - Detection electrode 7 - Flue safety thermostat 8 - Air intake pipe 9 - Condensation module 10 - Negative signal pressure point 11 - Positive signal pressure point 12 - Sample points (air A) - (fumes F 13 - Manual vent valve 14 - Burner 15 - Ignition electrode 16 - Flow probe 17 - Safety thermostat 18 - Automatic vent valve 19 - System expansion vessel 20 - Return probe 21 - Boiler pump 22 - System pressure switch 23-3 bar safety valve 24 - System draining valve 25 - System filling valve 4

5 victrix Superior kw MAIN DIMENSIONS Model Height mm Width mm Depth mm Ø int./exhaust mm VICTRIX Superior kw 830 440 350 100/60 5.1 CONNECTIONS B A B Casing upper line A = intake/exhaust B = intake Distance between the casing upper line and concentric bend axis Ø 60/100: 95 mm Distance between the casing upper line and separator bend axis Ø 80/80: A = 135 mm; B = 115 mm Model Flow M Return R Hot Outlet AC Cold Inlet AF Gas G Expansion Vessel Litres VICTRIX Superior kw 3/4" 3/4" 1/2" 1/2" 3/4" 7.5 (real 6.8) 5

6 victrix Superior kw X MAIN DIMENSIONS Model Height mm Width mm Depth mm Ø int./exhaust mm VICTRIX Superior kw X 830 440 350 100/60 6.1 CONNECTIONS B A B Casing upper line A = intake/exhaust B = intake Distance between the casing upper line and concentric bend axis Ø 60/100: 95 mm * Only in the presence of the Storage Tank Unit coupling kit Distance between the casing upper line and separator bend axis Ø 80/80: A = 135 mm; B = 115 mm Model VICTRIX Super kw X Flow M 3/4" Return R 3/4" * Stor. tank Flow MU 3/4" * Stor.ank Ret. RU 3/4" System Filling RR 1/2" Gas G 3/4" Expansion Vessel Litres 8 (real 8.0) 6

7 STORAGE TANK UNIT MAIN DIMENSIONS (Optional) 80 l storage tank unit 105 l storage tank unit 120 l storage tank unit 200 l storage tank unit Height mm 850 1020 850 1250 Width mm 500 500 600 600 Depth mm 500 500 600 600 80 litre storage tank unit 105 litre storage tank unit 120 litre storage tank unit 200 litre storage tank unit Stor. tank Flow MU Stor. tank Ret. RU Cold Inlet AF Hot Outlet AC Recirc. RC Panels Flow MP (op S.T.U. 200) 3/4 3/4 1/2 1/2 1/2 3/4 3/4 Panels Flow RP (op. S.T.U. 200) 7

8 pump head/flow rate graphics The "VICTRIX Superior kw / kw X series boilers are supplied with pump incorporated with electric three-speed adjuster plus automatic speed (factory-set). The automatic speed decides the most suitable setting for the pump on the basis of the T measured between system flow and return. The pump is already equipped with a condenser. The "VICTRIX Superior kw / kw X" series boilers have an adjustable by-pass that is set in the factory (screw turned by 1.5 turns with respect to the adjustment screw that is completely unscrewed). The adjustment can be modified by acting on the screw located on the by-pass unit. 8.1 VICTRIX Superior 32 kw - 32 kw X PUMP GRUNDFOS UPRO 15-70 AO HB Head (kpa) C A Head (m H 2 O) D B F E Flow rate l/h A: Head available to the system at third speed with by-pass excluded (adjustment screw tightened fully home). B: Head available to the system at second speed with by-pass excluded (adjustment screw tightened fully home). C: Head available to the system at first speed with by-pass excluded (adjustment screw tightened fully home). D: Head available to the system at third speed (screw tightened by 1.5 turns with respect to the adjustment screw that is completely unscrewed). E: Head available to the system at second speed (screw tightened by 1.5 turns with respect to the adjustment screw that is completely unscrewed). F: Head available to the system at first speed (screw tightened by 1.5 turns with respect to the adjustment screw that is completely unscrewed). 8

9 victrix Superior kw WIRING DIAGRAM ROOM THERMOSTAT OR REMOTE CONTROL The Comando Amico Remoto (CAR) remote control or the Super Comando Amico Remoto remote control, must be connected to terminals 42 and 43 of the connector X15 on the integrated P.C.B. respecting polarity and eliminating jumper X40. The boiler is designed to use the Room Thermostat (S20). Connect the room thermostat to terminals 40 and 41 of the connector X15 eliminating jumper X40. Any external probe (B4) must be connected to terminals 38 and 39 of the connector X15 on the integrated P.C.B. Brown Brown Brown Violet Brown D.H.W. Red (C.H.) Brown Orange Rose Rose Red Yellow Green Green Grey Grey Rose Orange Red Power Supply 230 Vac 50 Hz Super CAR (optional) ZONE CONTROL UNIT(optional) IMG BUS link FAN SPEED KEY: A4 - Display board E11 - Aqua Celeris resistance B1 - Flow probe F1 - Line fuse B2 - D.H.W. probe G2 - Igniter B4 - External probe (optional) M1 - Boiler pump B5 - Return probe M20 - Fan B6 - D.H.W. flow meter M30-3-way valve B9 - D.H.W. inlet probe M40 - D.H.W. flow rate regulator CAR - Comando Amico Remoto remote control S5 - System pressure switch (optional) S20 - Room thermostat (optional) E1 - Ignition electrode Super CAR - SUPER Comando Amico Remoto E2 - Detection electrode remote control (optional) E4 - Safety thermostat T1 - Voltage transformer E6 - Flue safety thermostat X40 - Room thermostat jumper Y1 - Gas valve 9

10 victrix Superior kw X WIRING DIAGRAM room THERMOSTAT OR REMOTE CONTROL The Comando Amico Remoto (CAR) remote control or the Super Comando Amico Remoto remote control, must be connected to terminals 42 and 43 of the connector X15 on the integrated P.C.B. respecting polarity and eliminating jumper X40. The boiler is designed to use the Room Thermostat (S20). Connect the room thermostat to terminals 40 and 41 of the connector X15 eliminating jumper X40. Any external probe (B4) must be connected to terminals 38 and 39 of the connector X15 on the integrated P.C.B. Storage Tank function jumper Brown Brown Brown Violet (D.H.W.) Red (C.H.) Grey Grey Brown Rose Orange Red STORAGE TANK (optional) Power Supply 230 Vac 50 Hz Super CAR (optional) ZONE CONTROL UNIT(optional) IMG BUS link FAN SPEED KEY: A4 - Display board G2 - Igniter B1 - Flow probe M1 - Boiler pump B2 - D.H.W. probe (optional) M20 - Fan B4 - External probe (optional) M30-3-way valve (optional) B5 - Return probe R8 - Storage tank inibitor resistor CAR - Comando Amico Remoto remote control S5 - System pressure switch (optional) S20 - Room thermostat (optional) E1 - Ignition electrode Super CAR - SUPER Comando Amico Remoto E2 - Detection electrode remote control (optional) E4 - Safety thermostat T1 - Voltage transformer E6 - Flue safety thermostat X40 - Room thermostat jumper F1 - Line fuse Y1 - Gas valve 10

11 victrix Superior kw HYDRAULIC LAY-OUT KEY: 1 - Condensate drain tap 2 - Water inlet filter 3 - D.H.W. flow rate regulator 4 - D.H.W. probe 5 - D.H.W. flow meter 6 - D.H.W. heat exchanger 7 - Aqua Celeris resistance 8 - Gas valve 9 - Gas valve outlet pressure point (P3) 10 - Aqua Celeris 11 - Air/gas Venturi collector 12 - Fan 13 - Gas nozzle 14 - Detection electrode 15 - Flue safety thermostat 16 - Air intake pipe 17 - Condensation module 18 - Manual vent valve 19 - Fumes hood 20 - Air sample point 21 - p gas pressure point 22 - Flue sample point 23 - Flow probe 24 - Safety thermostat 25 - Burner 26 - Ignition electrode 27 - Condensation module cover 28 - Venturi negative signal (P2) 29 - Venturi positive signal (P1) 30 - Return probe 31 - System expansion vessel 32 - Air vent valve 33 - Boiler pump 34 - One-way valve 35-3-way valve (motorised) 36 - System draining valve 37 - System filling valve 38 - Adjustable by-pass 39 - System pressure switch 40-3 bar safety valve 41 - D.H.W. inlet probe Attention: check the presence and cleanliness of the water inlet filter (2), which guarantees boiler efficiency. 11

12 victrix Superior kw X HYDRAULIC LAY-OUT KEY: 1 - Condensate drain tap 2 - System filling valve 3 - Gas valve 4 - Gas valve outlet pressure point (P3) 5 - Air/gas Venturi collector 6 - Fan 7 - Gas nozzle 8 - Detection electrode 9 - Flue safety thermostat 10 - Air intake pipe 11 - Condensation module 12 - Manual vent valve 13 - Fumes hood 14 - Air sample point 15 - p gas pressure point 16 - Flue sample point 17 - Flow probe 18 - Safety thermostat 19 - Burner 20 - Ignition electrode 21 - Condensation module cover 22 - Venturi negative signal (P2) 23 - Venturi positive signal (P1) 24 - Return probe 25 - System expansion vessel 26 - Air vent valve 27 - Boiler pump 28 - System draining valve 29 - System pressure switch 30 - Adjustable by-pass 31-3 bar safety valve 32 - One-way valve (Europa) 12

13 victrix Superior 32 kw TECHNICAL DATA Maximum nominal heat input kw (kcal/h) 32.7 (28,082) Maximum useful/nominal heat output kw (kcal/h) 32.0 (27,520) Minimum nominal heat input kw (kcal/h) 6.6 (5,634) Minimum useful/nominal heat output kw (kcal/h) 6.4 (5,504) Efficiency at 100% Pn (80/60 C) % 98.0 Efficiency at 30% of the load (80/60 C) % 100.6 Efficiency at 100% Pn (50/30 C) % 104.7 Efficiency at 30% of the load (50/30 C) % 106.8 Efficiency at 100% Pn (40/30 C) % 105.7 Efficiency at 30% of the load (40/30 C) % 107.0 Central heating system Central heating adjustable temperature (range 1 / range 2) C 25-85 / 25-50 Max. system operating temperature C 90 Max. system operating pressure bar 3 System expansion vessel nominal/real capacity litres 7.5 / (6.8) System expansion vessel pre-load pressure bar 1.0 Head available with flow rate of 1000 l/h kpa (m H 2 O) 26.48 (2.70) Domestic Hot Water Circuit Hot water production useful heat output kw (kcal/h) 32.0 (27,520) D.H.W. temperature adjustment C 30-60 D.H.W. circuit minimum dynamic pressure bar 0.3 D.H.W. circuit maximum pressure bar 10 D.H.W. min. flow rate litres/min 1.5 Flow rate for continuous service ( t 30 C) litres/min 16.3 Gas supply Gas pressure at the METHANE burner (G20) MIN - MAX mbar 0.14-2.45 Gas pressure at the LPG burner (G30) MIN - MAX mbar 0.15-2.68 Gas pressure at the LPG burner (G31) MIN - MAX mbar 0.18-3.35 Gas pressure at the METHANE burner (G20) MIN - MAX m 3 /h 0.70-3.46 Gas pressure at the LPG burner (G30) MIN - MAX kg/h 0.52-2.58 Gas pressure at the LPG burner (G31) MIN - MAX kg/h 0.51-2.54 Supply voltage V/Hz 230-50 Nominal power absorption A 0.62 Installed electric power W 135 Power absorbed by the fan W 26 Power absorbed by the pump W 95 Electrical insulation degree IP X5D Boiler water content (Aqua Celeris) litres 7.8 (4.0) Empty boiler weight kg 53.5 13

13.1 victrix Superior 32 kw X TECHNICAL DATA Maximum nominal heat input kw (kcal/h) 32.7 (28,082) Maximum useful/nominal heat output kw (kcal/h) 32.0 (27,520) Minimum nominal heat input kw (kcal/h) 6.6 (5,674) Minimum useful/nominal heat outputa kw (kcal/h) 6.4 (5,504) Efficiency at 100% Pn (80/60 C) % 98.0 Efficiency at 30% of the load (80/60 C) % 100.6 Efficiency at 100% Pn (50/30 C) % 104.7 Efficiency at 30% of the load (50/30 C) % 106.8 Efficiency at 100% Pn (40/30 C) % 105.7 Efficiency at 30% of the load (40/30 C) % 107.0 Central heating system Central heating adjustable temperature (range 1 / range 2) C 25-85 / 25-50 Max. system operating temperature C 90 Max. system operating pressure bar 3 System expansion vessel nominal/real capacity litres 8 / (8.0) System expansion vessel pre-load pressure bar 1.0 Head available with flow rate of 1000 l/h kpa (m H 2 O) 26.48 (2.70) D. H. W. Circuit (coupled with Storage Tank Unit) Hot water production useful heat output kw (kcal/h) 32.0 (27,520) D.H.W. temperature adjustment C 20-60 D.H.W. circuit maximum pressure bar 8 Flow rate x 10 min. ( t 30 C) S.T.U. 80 litres/min 21.8 Flow rate x 10 min. ( t 30 C) S.T.U. 105 litres/min 25.1 Flow rate x 10 min. ( t 30 C) S.T.U. 120 litres/min 26.6 Flow ratex 10 min. ( t 30 C) S.T.U. 200 litres/min 37.2 Flow rate for continuous service ( t 30 C) litres/min 15.3 Gas supply Gas pressure at the METHANE burner (G20) MIN - MAX mbar 0.14-2.45 Gas pressure at the LPG burner (G30) MIN - MAX mbar 0.15-2.68 Gas pressure at the LPG burner (G31) MIN - MAX mbar 0.18-3.35 Gas pressure at the METHANE burner (G20) MIN - MAX m 3 /h 0.70-3.46 Gas pressure at the LPG burner (G30) MIN - MAX kg/h 0.52-2.58 Gas pressure at the LPG burner (G31) MIN - MAX kg/h 0.51-2.54 Supply voltage V/Hz 230-50 Nominal power absorption A 0.79 Installed electric power W 175 Power absorbed by the fan W 26 Power absorbed by the pump W 95 Electrical insulation degree IP X5D Boiler water content litres 2.8 Empty boiler weight kg 47.5 14

14 victrix Superior 32 kw - 32 kw X COMBUSTION FEATURES Methane (G20) LPG (G30) LPG(G31) Combustion efficiency % 97.4 97.4 97.4 Combustion efficiency P min (80/60 C) % 97.7 97.7 97.7 Useful efficiency 100% Pn (80/60 C) % 98.0 98.0 98.0 Useful efficiency P min (80/60 C) % 97.0 97.0 97.0 Useful efficiency 100% Pn (50/30 C) % 104.7 104.7 104.7 Useful efficiency P min (50/30 C) % 107.0 107.0 107.0 Useful efficiency 100% Pn (40/30 C) % 105.7 105.7 105.7 Useful efficiency P min (40/30 C) % 107.0 107.0 107.0 Chimney losses with burner on (100% Pn) (80/60 C) % 2.0 2.0 2.0 Chimney losses with burner on (P min) (80/60 C) % 2.3 2.3 2.3 Chimney losses with burner off % 0.03 0.03 0.03 Casing losses with burner off % 0.46 0.46 0.46 Casing losses with burner on (100% Pn) (80/60 C) % 0.6 0.6 0.6 Casing losses with burner on (P min) (80/60 C) % 0.7 0.7 0.7 Flue temperature at Maximum Heat Input C 68 76 68 Flue temperature at Minimum Heat Input C 61 67 61 Flue flow rate at Maximum Heat Input kg/h 52 46 53 Flue flow rate at Minimum Heat Input kg/h 11 10 11 CO 2 at Maximum Heat Input % 9.40 12.30 10.40 CO 2 at Minimum Heat Input % 9.05 11.70 10.10 CO at Maximum Heat Input mg/kwh 155 579 168 CO at Minimum Heat Input mg/kwh 2 3 2 NO x at Maximum Heat Input mg/kwh 42 190 44 NO x at Minimum Heat Input mg/kwh 19 39 25 Weighted CO mg/kwh 17 - - Weighted NO x mg/kwh 30 - - NO x Class - 5 5 5 Available head at fan (Min. - Max.) Pa 50-270 The gas flow rates refer to the NCV at the temperature of 15 C and pressure of 1013 mbar. The fumes temperature values refer to the inlet air temperature of 15 C and flow temperature of 50 C. 15

15 victrix Superior 32 kw OptionalS Super Comando Amico Remoto remote control code 3.016577 Comando Amico Remoto remote control code 3.011236 Telephone control code 3.013305 External probe code 3.014083 Weekly digital chrono-thermostat code 3.014438 Radio-chrono-thermostat (wireless) code 3.014439 GSM telephone control kit code 3.017182 Configurable relay interface kit code 3.015350 Control unit kit for zone systems code 3.011668 Additional system expansion vessel kit (2 litres) code 3015450 Electric anti-freeze resistance kit (-15 C) code 3.015348 Polyphosphate dispenser kit code 3.014945 Interception cocks kit code 3.5324 Upper cover kit code 3.017209 Universal connection kit code 3.011667 Interception cocks with filter kit code 3.015854 Water disconnector kit code 3.015408 Remote filling kit code 3.017206 The boiler is prepared for coupling to the DIM (Multi-system Distribution Manifold), available in 5 recess kits. 16

16 victrix Superior 32 kw X OptionalS Super Comando Amico Remoto remote control code 3.016577 Comando Amico Remoto remote control code 3.011236 Telephone control code 3.013305 External probe code 3.014083 Weekly digital chrono-thermostat code 3.014438 Radio-chrono-thermostat (wireless) code 3.014439 GSM telephone control kit code 3.017182 Configurable relay interface kit code 3.015350 Control unit kit for zone systems code 3.011668 Additional system expansion vessel kit (2 litres) code 3.015413 Boiler anti-theft kit (mechcanical) code 3.015412 Interception cocks kit code 3.5324 Storage tank unit coupling kit code 3.019213 Upper cover kit code 3.017209 Interception cocks with filter kit code 3.015854 Connection kit to column (S.T.U. 105 and S.T.U. 200) code 3.014920 The boiler is prepared for coupling to the DIM (Multi-system Distribution Manifold), available in 5 recess kits. 17