Electrical Inspection Service & Distribution

Similar documents
Electrical Inspection Special Electrical

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

ELECTRIC SERVICE EVALUATIONS ELECTRICAL / BOILER REPLACEMENTS. Clarkstown Central School District. June Arch Proj. #

State College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Electrical Inspection Lighting & Power

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

Technical II Report Electrical Systems

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

Introduction Consultant shall incorporate the material in the DSS into the project specifications.

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

Florence High School / Middle School Page 1 of 3 Florence, WI

Element D Services Electrical

PLATTEVILLE MIDDLE SCHOOL

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

ELECTRICAL POWER SYSTEMS

MOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School

Mechanical Inspection Plumbing

Electrical Inspection Special Electrical

NYC Department of Education

PANELBOARDS & BUILDING DISTRIBUTION

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Cook - Wissahickon Elementary School

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required.

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

CONTENTS AUTOMATIC TRANSFER SWITCHES

Technical Report 2: Electrical Systems Criteria and Existing Conditions

S AGE E NGINEERING A SSOCIATES, LLP

PART GENERAL 1.01 SECTION INCLUDES

Electrical Safety Compliance: NFPA 70E

2017 NEC: Impact to Electrical System Designs

Smart Classroom Design

ELECTRICAL EXISTING CONDITIONS AND DESIGN ANALYSIS

NYC Department of Education

How to reduce exposure to arc flash hazards

SECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

White Paper SPDs for Essential Power Systems in Health Care Facilities

Assessing Your Airfield Electrical Distribution System

Existing Conditions Assessment November 14, 2006 NORTH MIDDLESEX REGIONAL HIGH SCHOOL Townsend, MA L21366/ /Page 1

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

A. Shop Drawing submittals shall include, but not be limited to, the following:

NYC Department of Education

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

NYC Department of Education

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

CONNECTICUT. Downloaded

DIVISION 16 - ELECTRICAL

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

NYC Department of Education

Executive Summary. CNBC Global Headquarters Christine Cajilig

NYC Department of Education

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Machinery Room Electrical Best Practices

Old Jail HVAC Replacement Feasibility Report

NYC Department of Education

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

DIVISION 16 - ELECTRICAL. A. This division contains the following elements:

NYC Department of Education

ELECTRICAL BULLETIN

National Electrical Code

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Attachment F. Campus Capital Needs Sales Surtax Funded Detail Report

Chang Liu Lighting + Electrical M.A.E./B.A.E. Integrated Degree. Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson

NYC Department of Education

Corbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth

Page 1 of General

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

SEL Arc-Flash Solutions

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

Electrical Design Guidelines Table of Contents

ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015

FINAL REPORT INFRASTRUCTURE MASTER PLAN UPDATE. Harper College. Palatine, Illinois

NYC Department of Education

PGR-8800 TECHNICAL FAQ

SECTION : MEPS IDENTIFICATION & LABELING

SEL Arc-Flash Solutions

NYC Department of Education

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Renovate MCRC Facilities Great Lakes, IL

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Sagebrush Elementary School East Temple Place Aurora, Colorado 80015

NYC Department of Education

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

Help Us Help YOU! A Guide to Requirements for. Commercial Electrical Permit Applications in the City of Winnipeg

Residential Wiring (2014 NEC) (Homestudy)

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Transcription:

0911 Distribution Panels & Switchgear Equipment, conduit, feeders, and grounding 480 Volt Switchboard: This switchboard contains the utility meter and two main, service, circuit breakers. One circuit breaker serves the electrically heated boiler and the other serves the electrically heated domestic water tank. Both circuit breakers are configured with shunt trip operators and ground fault relay protection. 208Y/120 Volt Switchboard: This switchboard contains the utility meter, a 1000 ampere main service circuit breaker, and a distribution section with 13 feeder circuit breakers. 208Y/120 Volt Emergency Panel: This distribution panel feeds four panelboards. It is fed from the 208Y120 Volt Switchboard and the Emergency Generator via the Automatic Transfer Switch. The switchboards and Emergency Panel were all installed with the 1982 renovation and are in good condition. All circuit breakers are currently available. Remaining life expectancy: 10+ years May 2005 Harborview Elementary School Condition Survey Report Page 173 of 210

Deficiency 0911 1 480 Volt Switchboard Circuit Breakers. Ground Fault Protection Relays: Test and Calibration Deficiency category: F Test and Calibrate the Ground Fault Protection Relays for the main circuit breakers in the 480 Volt Switchboard to ensure in compliance with originally specified settings. Estimated Construction Cost: $4,400 May 2005 Harborview Elementary School Condition Survey Report Page 174 of 210

0912 Branch Circuit Panels & Motor Controls Equipment, conduit, feeders, and grounding Branch Panels Basement: Six panels, A, B, BP, G, N, and C currently serve the basement area. Panel A is located to serve the east end while Panel C is located in the west end. Panel B resides in the boiler room serving the systems within and the site lighting. G serves the Emergency Generator, while N serves the Network Server Room. Panel N is a residential type load center. All are fed from the 208Y/120 Volt Switchboard. Branch Panels Main Floor: Four panels, F, E, M, and J reside in the corridor on the main floor. Panel F serves the east end while Panel J serves the west end. Panel M provides circuits for computer equipment in the classrooms and Panel E provides emergency power to the corridor lighting. All are fed from the 208Y/120 Volt Switchboard. Branch Panels Second Floor: Two panels, K and L, reside in the corridor on the second floor. Panel L serves the east end while Panel K serves the west end. Panel K is fed from the 208Y/120 Volt Switchboard while Panel L is fed via Panel F from below. Branch Panel Multipurpose Section: One panel, MPP, resides in the fan room located on the mezzanine of the Multipurpose Section. Panel MPP is fed from the 208Y/120 volt switchboard. Condition of the building system: Branch Panels Basement: Panels A & B were installed with the original building in 1950 and are in poor to fair condition. Panel BP was installed as part of the construction of the Multipurpose Addition in 1973 and is in poor to fair condition. Panels C & G were replaced with the 1982 renovation and is in good condition. Panel N was installed with the incorporation of the Administrative Offices and is in fair condition. It is inappropriate for its purpose. Branch Panels Main Floor: Panels E, F, & J were replaced with the 1982 renovation and are in good condition. Panel M was installed in 1999 and is in good condition. Branch Panels Second Floor: Panels K & L were replaced with the 1982 renovation and are in good condition. Branch Panel Multipurpose Section: Panel MPP was installed with the original construction of this section in 1973. It is in fair condition. Remaining life expectancy: number of years Panel A: 0 to 5 years Panel B: 0 to 5 years May 2005 Harborview Elementary School Condition Survey Report Page 175 of 210

Panel BP: 0 to 5 years Panel C: Panel 10+ years. Circuit breakers 5 years Panel E: Panel 10+ years. Circuit breakers 5 years Panel F: Panel 10+ years. Circuit breakers 5 years Panel G: Panel 10+ years. Circuit breakers 5 years Panel J: Panel 10+ years. Circuit breakers 5 years Panel K: Panel 10+ years. Circuit breakers 5 years Panel L: Panel 10+ years. Circuit breakers 5 years Panel MPP: Panel 5 to 10 years. Circuit breakers 0 to 5 years Panel N: Panel 0 to 5 years. Circuit breakers 5 to 10 years May 2005 Harborview Elementary School Condition Survey Report Page 176 of 210

Deficiency 0912 1 Replace Panels A, B, BP, & N Panels A and B are over 50 years old, Panel BP is 31 years old, and Panel N is not appropriate for the purpose it serves. Deficiency category: RR Replace panelboards and circuit breakers at Panel A, B, BP, & N. Estimated Construction Cost: $20,700 May 2005 Harborview Elementary School Condition Survey Report Page 177 of 210

Deficiency 0912 2 Replace Circuit Breakers Panels C, E, F, G, J, K, L, and MPP The circuit breakers in the panels are nearing the end of their expected service life. Deficiency category: RR Replace circuit breakers at Panels C, E, F, G, J, K, L, and MPP. Estimated Construction Cost: $24,200 May 2005 Harborview Elementary School Condition Survey Report Page 178 of 210

0913 Equipment & Motor Controls Equipment, conduit, feeders, and grounding Electrically heated boiler: The boiler is fed from the 480 Volt Switchboard with a 1200 ampere circuit breaker protecting four sets of 500 Kmil conductors with a No. 2 ground conductor. The boiler is rated 780 KW and interlocked with AEL&P as part of the Dual Fuel program. AEL&P may secure operation of the boiler under certain utility conditions to ensure adequate power capacity for all its customers. The boiler elements are controlled individually to maintain a set temperature level within the boiler. Electrically heated domestic water tank: The water heater is also fed from the 480 Volt Switchboard. It is served from a 125 ampere circuit breaker protecting a circuit sized with 1/0 conductors. The heater is rated at 80 KW and is interlocked with AEL&P similar to that for the boiler. Controls: The heating and ventilation system is controlled with conventional full voltage motor starters installed with both the original construction and the 1982 renovation. Condition of the building system: Electrically heated boiler and domestic water: These units were installed with the 1982 renovation and appear to be in good condition. The electrical demand for the boiler and water heater together was recorded in April to be approximately 625 KW (750 amperes). The measurement is made using a sliding window measurement technique with the highest load exceeding 15 minutes of operation recorded. The boiler was observed to operate at high output for short periods of time to compensate for consumption in the building, thus not recording the high levels. Controls: The motor controllers are in poor to fair condition. Remaining life expectancy: Electrically heated boiler and domestic water tank: 5 to 10 years. Controls: 0 to 5 years. Deficiency 0913 1 Replace Motor Controllers The motor controllers and starters for the facilities heating and ventilation system are 23 years old and older, in poor condition, and at the end of their service life. Deficiency category: RR Replace motor starters and associated controls for the facilities heating and ventilation equipment. Estimated Construction Cost: $12,800 May 2005 Harborview Elementary School Condition Survey Report Page 179 of 210

0951 Power Generation Generators, switchgear, panels, conduit, feeders, & grounding The facility is supported with a generator rated in compliance with the NFPA for emergency power support. It is connected to power a portion of the 208Y/120 volt system through an automatic transfer switch. The generator, installed with the 1982 renovation, is rated to provide for a load up to 30 KW. The automatic transfer switch, integral to the generator unit, is rated at 200 amperes. The loads served by the generator include Panel E (emergency lighting in the corridors), Panels B & BP (heating system), and Panel G (generator ancillary equipment) Condition of the building system: The generator and automatic transfer switch appear to be in fair to good condition. Although the equipment is relatively old, it is probable that spare parts are available. It is questionable whether the generator has been tested in accordance to the NFPA as required for emergency service. Only the loads on Panel E require such testing. The other loads qualify as standby loads, thus reducing the requirements for the generator and testing. Remaining life expectancy: 5 to 10 years May 2005 Harborview Elementary School Condition Survey Report Page 180 of 210

Deficiency0951 1 Generator Testing and Upgrades Generator does not appear to have been tested and upgraded per NFPA code. Deficiency category: C NFPA 110 (Chapter 8) Test the generator and automatic transfer switch in accordance to NFPA 110, Chapter 8. Base the testing requirements for Level 1, Class 2, Type 10 requirements. Provide recommended upgrades based on the results of the tests. Estimated Construction Cost: $6,300 May 2005 Harborview Elementary School Condition Survey Report Page 181 of 210