Gas Analyzing System Based on Semiconductor Sensors for Providing Safety of Oil And Gas Pipeline Operations

Similar documents
Remote Detection of Leaks in Gas Pipelines with an Airborne Raman Lidar. Strategic Insights, Volume VII, Issue 1 (February 2008)

Catalytic Bead DrägerSensors for Fixed Gas Detectors

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

Dräger X-am 7000 Multi-Gas Detection

an ISO9001 company TECHNICAL INFORMATION FOR TGS813 Technical Information for Combustible Gas Sensors

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Safety Engineering. Fire Protection Systems and Life Safety Systems

A New Micromachined Sensor Platform. Debra J. Deininger Synkera Technologies Inc. June 6, 2007

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Dräger Polytron Pulsar 2 Open Path Gas Detector

Semiconductor Radiation Detectors

Chemistry Instrumental Analysis Lecture 14. Chem 4631

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Series 9000 Total Hydrocarbon Analyzer

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Standard Operating Procedure: Sputter

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Heated tools. Semiconductor equipment

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

Dräger X-am 5000 Multi-Gas Detection

Dräger PIR 3000 Detection of flammable gases and vapours

Hydrocarbon Gas Detector

Dräger REGARD -1 Control System

3 3SP_O3_5 C Package

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Dräger X-am 2500 Multi-Gas Detector

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Dräger Catalytic Ex-Sensors DrägerSensors

IMR EX610. Portable Gas Detector. Operation Manual

E1000 Portable gas detector

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

Model D12-IR. Digital Gas Transmitter...

IMR IX176 Portable Gas Detector User Manual

Temperature dependent Components within the Pyroelectric Detector

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

CARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS

Saintech Ion Beam Systems - Ion Current Monitor

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Manual Physical Vapour Deposition System

TGS for the detection of Carbon Monoxide

Monitoring Flammable Vapors and Gases in Industrial Processes

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

HYDROGEN DETECTION INSTRUMENTATION FOR THE SIAC HYDROGEN RECOMBINERS. Summary

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

SIL 2. Ultima X Series Gas Monitors CERTIFIED

testo 316-EX gas leak detector Instruction manual

Innovative Technology for Traditional and Challenging Applications

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

3SP_H2S_50 Package

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

Operation and Maintenance Manual

Dräger PIR 7200 Toxic Gas Detection Transmitter

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

NEXTorr Pumps. making innovation happen,together

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger X-am 2500 Multi-Gas Detection

White paper on the Dielectric Barrier Discharge Detectors. Introduction:

HARSH ENVIRONMENT ELECTRONICS AND SENSORS APPLICATIONS

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

FIRE & SAFETY SPRING 2016 EDITION

Thermo Scientific TVA2020 Introduction

DESCRIPTION AND SPECIFICATION

UV-Ozone Technology and Applications

MICROSYSTEMS FOR SELECTIVE GAS SENSING. Ulrike Lehmann, MICROSENS. Gas Sensor Microsystems U. Lehmann, A. Grisel, MICROSENS 1

NJSP HMRU. Module 5 B HM Operations 1

Products and performance

SEC 5000 IREvolution Gas Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

SIMRAD GD10PE IR GAS DETECTOR

Technical data sheet TDS0060

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Automated Infrared Thermography Complete Solutions from a Single Source

Dräger X-am 5000 Multi-Gas Detector

Gencoa Limited, Physics Road, Liverpool, UK 2. Gencoa USA, Davis, CA, USA 3. Nano4Energy, Madrid, Spain 4. Universidad Autonoma de Madrid, Spain

The design of the human body infrared thermometer

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Senscient s team has more than 150 years collective experience in gas. detection.

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Improving Productivity, Quality and Security

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Study of Mid-Infrared Optical Properties of ZnS Thin Films by Spectroscopic Ellipsometry

SIMRAD GD10 IR GAS DETECTOR

Transcription:

Gas Analyzing System Based on Semiconductor Sensors for Providing Safety of Oil And Gas Pipeline Operations Strategic Insights, Volume VII, Issue 1 (February 2008) by O. Tolbanov, O. Anisimov, V. Sachkov, G. Sakovich, Alexander Vorozhtsov, N. Eisenreich, and M. Krausa Strategic Insights is a bi-monthly electronic journal produced by the Center for Contemporary Conflict at the Naval Postgraduate School in Monterey, California. The views expressed here are those of the author(s) and do not necessarily represent the views of NPS, the Department of Defense, or the U.S. Government. Abstract The present paper describes the development of automatic gas analyzing system which contains a control and detection unit and a network of semiconductor sensors allocated along the oil and gas pipeline and connected with each other by five-wire line. The system provides permanent control of explosive gases (CxHy) in the range of 0 100 percent LEL and automatic and handoperated scanning of all sensors for determining the exact location of a signaling sensor. The reliability of the system is improved by applying software methods allowing compensating automatically the influence of the external factors such as environmental temperature (in the range of -55 +55 C) and humidity (in the range of 0 100 percent) on the sensors performances. Keywords: SnO 2 thin film gas sensors, inflammable gases, environment temperature and humidity Introduction The development of portable gas detectors and analyzers of explosive gases is a topical problem caused by necessity to improve the safety of oil and gas pipelines operation, working conditions at mining and industrial processes and home safety. The lack of reliable and efficient gas sensors at the market restrains the development of portable control and analyzing equipment of various gas mediums. SnO 2 based materials are widely used for gas sensor applications. They demonstrate sensitivity to the majority of toxic and inflammable gases. Due to the reaction of reducing gas molecules with chemisorbed oxygen species (O 2 - or O-) on the semiconductor surface, the potential barrier between the oxide particles is reduced by releasing electrons to the conduction band of SnO 2. The gas response of the sensor film is determined by the ratio R air /R gas, where R air and R gas are the sensor resistance in air without and with a reducing gas. However, low stability and poor selectivity restrict their application area. Electrical properties of SnO 2 sensing element are influenced not only by molecules of the target gas but also by other gases and environment conditions (environment temperature and humidity).

Selectivity and stability of a semiconductor gas sensor can be improved by several methods: modification of the sensing material, e.g. by doping with catalytic and electroactive admixture and optimization of the working conditions. We developed and tested tin oxide thin films with various additives in order to create a reducing gas sensor. The sensitive elements, made by microelectronic technology (Figure 1), have low power consumption, small size, fast gas response and low cost. The selectivity to particular gases is provided by sensor type, manufacturing technology and working temperature. The reliability of the sensing system is improved by applying software methods allowing compensating automatically the influence of the external factors such as environment temperature (in the range of -55 +55 C) and humidity (in the range of 0 100 percent RH) on the sensors parameters. The sensitive elements consist of sapphire substrate of 1.2x1.2x0.15 mm size. SnO 2 thin films (~ 100 nm) are obtained by RF magnetron sputtering of the tin target with additional 1.5 percent of antimony in oxygen-argon plasma. The superthin layers of catalytic Pt are received also by RF magnetron sputtering. The working temperature of a sensor is kept by platinum heater that is deposited by magnetron sputtering method on the other side of substrate prior to the deposition of the semiconductor film. The films are annealed in an air for 24 h at 400 C. The working elements are mounted onto TO-8 socket (Figure 2). Figure 1: The Sensitive Elements Based on SnO 2 Thin Films

Figure 2: Gas Sensors Based on SnO2 Thin Films In order to stabilize the working parameters the gas sensor operates in pulse mode: two hours heating of the sensor with temperature stabilization at 430 C, three seconds cooling of the sensor up to 95 C. The resistance of the sensor is measured in two points of the each impulse for automatic compensation of the environment influence. For calculating the current concentration of explosive gases in the air the analytic expression has been obtained which allows compensating the drift of the sensor parameters at the change of temperature and ambient humidity: where C i = numerically calculated gas concentration; m = concentration coefficient; n = temperature coefficient; k = humidity coefficient; R i1 = value of sensor resistance at room temperature; R i2 = value of sensor resistance at room humidity; U i = value of the heater voltage at room temperature; C 0, R 0, U 0 = constants. In Figure 3, the methane response of the sensor depending on the ambient temperature and humidity is showed. It is calculated applying the expression mentioned above. It is clear the inclusion of adjustment coefficient allows providing independence of the sensor parameters from environment condition. Figure 3,

Developed gas analyzing system represents a network of detectors connected with each other and attached to a single processing and signalization unit. Each detector (Figure 4) consists of a gas sensor, heating and temperature stabilization system, conductivity measuring unit, signal processing and exchange unit. Connection between detectors and the main unit is established applying RS-485, and each detector has its own unique address. Figure 4: СхНу-Detector Based on Semiconductor Sensor The advantages of the developed gas analyzing system are the following:

high sensitivity and stability of detectors; personal address of each detector; continuous automatic testing and autocalibration of each detector; wide range of climatic conditions of the system operation. For more insights into contemporary international security issues, see our Strategic Insights home page. To have new issues of Strategic Insights delivered to your Inbox, please email ccc@nps.edu with subject line "Subscribe." There is no charge, and your address will be used for no other purpose.