QS1 Intelligent single loop life safety control panel

Similar documents
INTELLIGENT FIRE ALARM CONTROL PANEL

QS4 Fire Alarm Control Panel

QS1 Technical Reference Manual P/N REV 05 REB 14FEB13

good things in small packages

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

QSC Technical Reference Manual P/N REV 05 REB 14FEB13

NETWORK FIRE ALARM CONTROL PANEL. Features

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

LifeAlarm Fire Alarm Control Panels

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

QS1 Technical Reference Manual P/N REV 05 REB 14FEB13

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Addressable Fire Alarm Control Panel

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

FireNET Plus Wiring Instructions

Signature Series Auto-Sync Output Module (CC1S)

io64 Intelligent Life Safety System

Intelligent Single Loop Fire Alarm Control Panel

VS1 Intelligent Life Safety System

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

CATALOG NUMBER. Features. Description

30.45 Electric Release PDRP-2001

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

D7024 Fire Alarm Control Panel

Conventional Fire Alarm Systems

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

MPC-6000 / MPC-7000 / RND-2

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Print Specification. Publication. Instructions. Specific requirements. General requirements

Specification/ Data Sheet

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

SIGA-CC1 Single Input Signal Module Installation Sheet

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

ECC-50/100C. Emergency Command Center

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

System Accessories, LCD Annunciators

Conventional Releasing Control Panel

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

Installation, Operating and Maintenance Manual

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual

Control Relay Modules

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

MR-2602 Two Zone Fire Alarm Control Panel

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

EST2. Life Safety Systems Control Panels. Analog Control Panel. Standard Features. Overview

Booster Power Supply Manual

DS7400Xi Addressable Control/ Communicator

4007ES Fire Control Panels

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

LifeAlarm Fire Alarm Controls

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Addressable Detectors & Bases

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AND ARCHITECT SPECIFICATIONS

Addressable NAC Output Module D327A

AND ARCHITECT SPECIFICATIONS

Desigo TM Fire Safety System A comprehensive fire-protection system

AL600ULADA. NAC Power Extender. Installation Guide

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

TrueAlarm Fire Alarm Systems

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

June 10, 2002 DF C S2424

Multi-Application Peripherals and Accessories

Desigo TM Fire Safety System A comprehensive fire-protection system

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

PFC-4064 Conventional Fire Alarm Panel

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Cerberus PRO A comprehensive fire-protection system

PSN-1000 & PSN 1000(E) Installation Manual

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Laptop / PC Programming Manual

V-Series Life Safety Systems

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

4100U City and Relay Cards Installation Instructions

AL800ULADA. NAC Power Extender. Installation Guide

Transcription:

EDWARDS SYSTES TECHNOLOY T NTERNATONAL CONTROL PANELS QS1 ntelligent single loop life safety control panel eatures! Supports up to 250 Signature Series intelligent devices! Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable suppression! ailsafe mode ensures uncompromised reliability! (Style 7) or Class B (Style 4) wiring options! Capacity for eight serial annunciators! our built-in system relays! Optional dual line dialer supports Contact D and 4/2 formats! Three methods of programming: QuickStart auto-learn, front panel and personal computer (PC)! Supports optional barcode scanner for direct device data entry! Optional bank of 30 front panel switches with dual LEDs! Up to 20 adjustable pre-alarm settings for Signature smoke detectors! Wallboxes available in red or gray with optional trim ring for semi-flush mounting.! Large 14-line (224 character) backlit LCD display! our password levels, plus priority access keyswitch! essage routing by event type or by individual message! Alarm sensitivity by time of day or manual selection! 1,000 event history buffer, plus alarm history counter! 6 amp Power Supply, 4.75 amps available for external use! ULC-S527-99 compliant! Compare utility identifies system changes and simplifies testing Description EST s QS1 life safety control panel brings big-system intelligent control to small applications. Designed for easy setup and simple installation, QuickStart lives up to its name in every respect. QS1 s exclusive QuickStart auto-learn function, and the option of configuring the panel using convenient front panel programming or from a PC, makes short work of system setup. Devices come online in no time as well, thanks to QS1 s built-in barcode scanner port. A simple pass of the optional scanner is all it takes to store device information in the QuickStart database. The scanner can also be used for quick and easy text entry when assembling custom messages. QS1 s setup routine is deceptively simple, considering this system s robust features. Supporting up to 250 intelligent detectors and modules, QS1 takes full advantage of EST s exclusive Signature Series technology, which provides electronic addressing, automatic device mapping, al compensation, and true multisensor detection. QuickStart s innovative design makes it easy to add a dialer or extra auxiliary relays. Quick-Lok option cards snap onto QS1 s easily-accessible DN mounting rails. QS1 also supports as many as eight remote annunciators and up to 30 programmable front panel switches with dual LEDs for system control and display. QS1 is as simple to operate as it is to set up. ts large 14-line backlit LCD display provides easy-to-understand details concerning up to 1,000 system events, while bright system status LEDs and large, tactile control buttons present the user with a clean, crystal clear interface. our password levels limit control and information retrieval to authorized personnel. A priority access keyswitch gives Level 2 access without a password to management and emergency personnel. Application Thanks to its flexibility and simple setup and operation, QS1 is ideal for new installations in schools, apartment buildings, hospitals, office buildings, and retail facilities. The benefits brought by QS1 to retrofit applications underscores the true potential of this powerful system. As an intelligent panel, QS1 supports Signature Series devices, which can use existing wiring in most retrofit applications. This makes upgrading from a conventional system to analog control a simple operation with minimal disruption to normal operations at the site. 201 CTY CENTRE DRVE SUTE 500, SSSSAUA, ONTARO, CANADA L5B 2T4 PHONE: (001) 905-270-1711 AX: (001) 905-270-9553 WORLD WDE WEB: WWW.ESTNTERNATONAL.CO U.S. SALES: SARASOTA, L; PHONE 941-739-4200; AX 941-727-0740 CANADA SALES: OWEN SOUND, ON; PHONE 519-376-2430; AX 519-376-7258 ssue 3 Literature Sheet #85005-0113 Page 1 of 6 B

Operation ndicators 1. Text display and controls: Displays system messages, status information, and programming menus. Arrow buttons move the display cursor. 10 11 12 2. Alarm LED: ndicates a fire or life threatening emergency. 3. Supervisory LED: ndicates an off-normal condition with the fire suppression system or related equipment. 4. Disable/Test LED: ndicates part of the system is disabled or being tested. Disabled components also signal a system trouble. 5. onitor LED: ndicates the operation of an ancillary system function (door closures, fan pressure switches). 6. Trouble LED: ndicates an off-normal condition or wiring fault that compromises the integrity of the system. 7. round ault LED: ndicates a ground fault in the system wiring. round faults also signal a system trouble. 8. CPU ail LED: ndicates an unexpected reboot or failure with the microprocessor. CPU failures also signal a system trouble. 9. Power LED: ndicates the panel has power. 10. Help button: Provides additional information about the device selected on the display. 11. Status button: Displays the Status enu from which you can identify active or disabled points in the system. 12. Panel Silence/Acknowledge button and LED: Acknowledges all events posted in the display queues and turns off the panel buzzer. The panel silenced LED indicates that off normal events have been acknowledged. CPU / LCD Display 1 2 3 4 5 6 7 8 9 The QS1 front panel display provides 14 lines by 16 characters of text detailing event, device, diagnostic, and programming information. ts large backlit LCD screen is easy to read and always provides at-a-glance indication of the system s state of operation. The CPU/Display Unit houses the CPU card and mounting space for one optional LED/ card. Controls 13. Reset button: Allows devices or zones in alarm or trouble to restore to their standby condition. The LED indicates that the 19 20 21 panel is resetting. 14. Alarm Silence button: Turns active notification appliances off depending on panel programming. Pressing Alarm Silence a second time turns them back on. The LED indicates that the panel is in alarm and operating with notification appliances turned off. 15. Drill button: Activates notification appliances depending on panel programming but does not place the panel in alarm. The LED indicates that the panel is in Drill ode. 16. enu button: Displays the operator menus. 17. Delete button: Returns to the previous menu or backspaces the cursor. 18. Enter button: Press the Enter button to accept information or continue to the next item. 19. Numeric keypad: Numbered buttons for entering values and making menu selections. 20. Barcode scanner jack: nput for optional barcode scanner. 21. Priority Access keyswitch: Enables control functions reserved for access level 2 and above without requiring a password. Temperature: 32 120 (0 49 C) Standby: 117 ma when connected to PS6; 105 ma when connected as a remote annunciator Alarm: 13 14 15 16 17 18 135 ma when connected to PS6; 123 ma when connected as a remote annunciator Display with two alarms shown ailsafe ode f the CPU loses communication with other circuit cards, the power supply card continues to monitor the system for any alarm events. f an alarm occurs on any device or circuit during a communications failure, the power supply activates all alarm outputs and instructs the dialer to transmit a default alarm message to the monitoring station. Page 2 of 6 Literature Sheet #85005-0113 ssue 3

Typical R U Signature Data Circuit R ire Damper Class B Notification Appliance Circuit Signature Data Circuit CC1 Notification Appliance Circuit with enesis Signals and Signal aster for ndependent Horn and Strobe Control and Synchronization over two conductors. 2nd loor 2 R LEEND Enhanced ntegrity Horn-Strobe enesis Horn-Strobe enesis Signal aster Smoke Detector 2-Wire Smoke Detector Smoke Detector with Relay Base Smoke Detector with solator Base anual Pull Station unction Box O U CT2 CC1 R End-of-Line Resistor Programmable /O odule Universal /O odule Dual Circuit nput odule Control Relay odule Signal odule Signal odule (synchronization) Riser onitor odule 1 onitor odule O QS1 Panel 24 Vdc Critical Process onitoring with Control CT2 Waterflow Sprinkler Supervisory Notification Appliance Circuit Elevator Capture ore wiring suggestions can be found in the QS1 ire Alarm Control Panel nstallation, Operation, and aintenance anual, P/N 3100184. Dimensions 4.88 (12.4 cm) 18" (45.72 cm) R Signature Data Circuit (1 pr.) 24 Vdc R ire Damper Class B Signature Data Circuit Horn and Strobe Synchronization with Audible Silence Class B Notification Appliance Circuit with enesis Signals and Signal aster for ndependent Horn and Strobe Control and Synchronization over two conductors. 2nd loor ounting 2.2" (5.6 cm) 2.68" (6.8 cm) 14¼" (46.2 cm) 4.88" (12.4 cm) Horn and Strobe Control (2 pr) CC1 1 24 Vdc QS1 Panel Critical Process onitoring CT2 Notification Appliance Circuit: Horn and Strobe Synchronization with Audible Silence Waterflow Sprinkler Supervisory Elevator Capture Wall Semi-flush ounting* Wall Surface ounting *Semi-flush mounting requires an optional trim ring, which adds ¾" to all sides of the panel. ssue 3 Literature Sheet #85005-0113 Page 3 of 6

Standard Components and Option Cards QS1 panels come standard with a CPU/Display Unit, an SLC Signature Loop Controller, and a PS6 Power Supply (see ordering information for details). Available QS1 option cards provide dialing capability or extra relays for anciliary control. Quick-Lok option cards snap onto DN mounting rails for fast, no-fuss installation. One option card space is available. Cabinet with option card and batteries installed. Power Supply Card STANDARD COPONENT PS6 The PS6 provides primary dc power to all the circuit cards installed in the cabinet. There are four 24 Vdc power output circuits three for powering auxiliary applications, and one for powering four-wire smoke detectors and a charging circuit for standby batteries. The PS6 also provides common alarm, supervisory, and trouble relays, as well as a fourth relay that is user programmable. Common relay Remote annunciator bus 4-wire smoke or accessory power RS-232 serial connection for ancillary devices NO C NC C NO C NO C NO N/U RTS TX RX CO RELAY 1 RELAY 2 RELAY 3 RELAY 4 SOKE RS485 RS232 ACC PWR BATT PWR N.C. 12VDC 12VDC AUX POWER AUX1 AUX2 CO AUX3 CO Auxiliary power Relay 1: orm C. Contacts change position when the control panel processes an alarm signal and remain changed until all active alarm inputs restore and the control panel resets. Relay 2: orm A. Contacts change position when the panel processes a supervisory signal and remains changed until all active supervisory inputs restore. Relay 3: orm A. Contacts change position when the panel loses power or processes a trouble signal and remains changed until power returns or the trouble clears. Relay 4: orm A. Relay closes and opens according to panel programming. Smoke/Accessory Power: umper setting determines if the 24 Vdc is constant or resettable. ain supply circuit Battery charging circuit Smoke/Accessory power output circuit Auxiliary power output circuits Common alarm relay Trouble, Supervisory and programmable relays AC input: 115 or 230 Vac, 50/60 Hertz DC input: 24 Vdc batteries Charge current: 2 amps Charge capacity: 40 amp hours (UL) 30 amp hours (ULC) Voltage: 24 Vdc, regulated : 250 ma Wire size: 12 to 18 (0.75 to 2.5 mm²) Quantity: 3 Voltage: 24 vdc full wave rectified : 1.5 amps each Style: orm C Contact rating: 1 amp Wire size: 18 to 12 AW (0.75 to 2.5 mm²) Style: orm A (N/O) Contact rating: 1 amp Wire size: 18 to 12 AW (0.75 to 2.5 mm²) Temperature: 32-120 (0-49 C) Standby current: 72 ma Alarm current: 96 ma Signature Loop ntelligent Controller The SLC provides one or Class B data circuit (loop) for connecting Signature Series detectors and modules. The SLC also provides two programmable or Class B notification appliance circuits (NACs) for connecting polarized 24 Vdc notification appliances such as horns and strobes. QS1 supports one SLC. EOL EOL B+ B A+ A B+ B A+ A NAC 1 NAC 2 OUT N LOOP + + A+ A B+ B C STANDARD COPONENT Signaling Line Circuit and NACs are supervised and power-limited. Signaling line circuit Notification appliance circuits #1 and #2 NAC power input circuit Card spaces SLC Configuration: Class B (Style 4) or (Style 7) Capacity: 125 Signature detectors 125 Signature modules Wire size: 18 to 12 AW (0.75 to 2.5 mm²) Circuit resistance: 65 ohms Circuit capacitance: 0.3 µf Configuration: Class B or Output voltage: 24 Vdc, nominal Output current: 2.0 A at 24 Vdc for #1 and A at 24 Vdc for #2 Wire size: 18 to 12 AW (0.75 to 2.5 mm²) End of line resistor: 10k ohms, ½ W Voltage: 24 Vdc, nominal Wire size: 18 to 12 AW (0.75 to 2.5 mm²) Temperature: 32-120 (0-49 C) Standby current: 33 ma Alarm current: 57 ma (Both NACs on) Requires one card space. Page 4 of 6 Literature Sheet #85005-0113 ssue 3

Dialer OPTON CARD DLD The DLD is a UL/ULC listed dual line Digital Alarm Communicating Transmitter (DACT). t provides two phone line for sending system messages to a compatible Digital Alarm Communicator Receiver. The DLD supports 4/2 and Contact D formats. t occupies one card space on the chassis rail. R31X 8 PN ODULAR CONNECTOR OR PHONE LNE #1 NO T-TAPS PERTTED 4 3 5 6 2 7 1 8 SURE PROTECTOR RN (RED) TP (REEN) PRESES PHONES REEN RED 4 3 TO PHONE LNE #2 (WRED SAE AS PHONE LNE #1) 5 6 2 7 1 8 TP RN TP RN TP RN TP RN N OUT N OUT LNE 1 LNE 2 R31X 8 PN ODULAR CONNECTOR OR PHONE LNE #2 Phone Lines Wall Connector Communications Protocol Programming Communications Compliance Receivers Telephone #s Card spaces Temperature: 32-120 (0-49 C) Humidity: 93% RH, non-condensing Standby: 13 ma Dialing: 26 ma Two loop start lines on switched telephone network. Pulse or DT dialing. R31X/CA31A equiv. or R38X/CA38A equiv. Contact D (SA DC-05), 4/2 (SA DC-02 P3). Via QuickStart, ront Panel or PC. Communications Canada CS-03CC/CR 47 Parts 15 and 68, NPA 72, UL 864, ULC S527-87 Signals can be transmitted to either or both of two receivers. Two 24-digit numbers per receiver. Requires one card space. Relay Card OPTON CARD ZR8 The ZR8 provides eight dry-contact relays that can be independently configured as orm A or orm B relays. t occupies one card space on the chassis rail. +R5 +R6 +R7 +R8 Output relays Card spaces Style: orm A or orm B (jumper configurable) Contact rating: 1 amp @ 30 Vdc resistive. Wire size: 18 to 12 AW (0.75 to 2.5 mm²) Temperature: 32-120 (0-49 C) Standby current: 7 ma Alarm current: 18 ma per active relay Requires one card space. +R1 +R2 +R3 +R4 RS-485 Card and QS-232 Port The NT-A, which includes the X485/ RS-485 card and QS-232/UART port, provides one serial remote annunciator bus for connecting remote annunciator panels. Control panels require the X485 card and QS-232 port, which also serves as a laptop or printer port. The X485 occupies one card space on the chassis rail. The QS-232 port plugs into the panel CPU. + + CH2 CH1 CH2 RA CH1 OPTON CARD CH2 RA CH1 X485 Wire size 12 to 18 AW (0.75 to 2.5 mm²) twisted pair (6 twists per foot minimum) Circuit resistance 100 Ohms Circuit capacitance 0.4 µ Temperature: 32-120 (0-49 C) Humidity: 93 %RH, noncondensing Standby: 75 ma Alarm: 75 ma Card Spaces Requires one space for the NT-A QS-232 UART Port ssue 3 Literature Sheet #85005-0113 Page 5 of 6

LED/ Card The SL30 provides thirty switches with two associated LEDs per switch. These switches and associated LEDs can be used for point or zone annunciation of alarm, supervisory, monitor, and trouble signals. Buttons on the SL30 are numbered 1 through 30. OPTON CARD Temperature: 32-120 (0-49 C) Humidity: 93% RH, non-condensing Standby: 1mA Alarm: 0.75 ma per active LED SL30 Remote Annunciators QS1 supports up to eight remote annunciators, which provide mirrored or customized annunciation of front panel messages and status indicators. Remote annunciators connect directly to the PS6 Power Supply Card or an external 24 Vdc filtered supply. They are available with wallboxes for flush or surface mounting. Remote annunciator (Class B wiring) Remote Annunciator Dimensions 24VDC RSER PS6 13 PS6 14 RA odel Height Width Depth QSA-1-S 7.6" (11.68 cm) 14.25" (36.20 cm) 2.9" (7.3 cm) QSA-1- (rough in) 6.56" (16.66 cm) 13.25" (33.66 cm) 2.1" (5.33 cm) QSA-1- (finished) 7.8" (19.81 cm) 14.42" (36.63 cm) 1.38" (3.49 cm) Rough-in dimensions reflect the size of the cabinet where it enters the wall. inished dimensions reflect the size of the cabinet that protrudes from the wall. Ordering options (Apply to basic packages and CPU/displays only) Languages No suffix = American English BR = British English (230v only) SP = Spanish (230v or 115v) P = Portuguese (230v only) R = rench Canadian (120v only) Which Quickstart Panel is right for you? QSC QS1 QS4 Signature Series devices supported 0 1 x 250 4 x 250 Conventional Class B circuits supported 3 x 16 0 3 x 16 Conventional circuits supported 5 x 8 0 5 x 8 LCD display (lines x characters) 4 x 20 14 x 16 14 x 16 Optional Zone /LEDs on front panel 2 x 30 1 x 30 2 x 30 Option card spaces 5 or 12 1 5 or 12 or more information, see catalog sheet number... RA Power Supplies 1 = 115v transformer 2 = 230v transformer Colors = rey enclosure (230v or 115v) R = Red enclosure (115v only) Examples QS1-1--2-SP = QS1 basic package with one option card space, grey enclosure, 230v transformer, Spanish language. QS1-CPU-R = QS1 CPU/display, rench Canadian. 85005-0112 This Sheet 85005-0114 Ordering nformation Part Number Description Ship Wt. lb. (kg.) Basic Package - Enclosure, SLC, Power Supply, CPU and Display QS1-1--1 Single Loop System. One option card space. ray enclosure with 115v transformer. QS1-1-R-1 Single Loop System. One option card space. Red enclosure with 115v transformer. Note: SLC Card includes One Signature Loop ntelligent Controller for up to 250 devices and one or two Class B NACs. Enclosure Accessories 17.0 (7.71) 17.0 (7.71) TR-1 Trim Kit - gray 5.0 (2.27) TR-1R Trim Kit - red 5.0 (2.27) Option Cards DLD Dual Line Dialer. Supports 4/2 and Contact D formats. ZR8 Relay Card. 8 programmable orm A contacts. Display Options SL30 Annunciator module. Numbered 1 to 30. Two LEDs and one switch per zone. QS1-CPU-1 Single Loop CPU/Display, one annunciator option space 4.0 (1.81) NT-A RS-485 option card. Required for remote annunciation. ncludes UART card. QS-232 UART option card. Plugs into CPU. Required for PC Programming / printer port. ncluded in NT-A package Remote Annunciator Cabinets (c/w nterface Assembly; Require CPU/Display) QSA-1-S Surface Remote Annunciator Cabinet. Space for one SL30 display card. 4.0 (1.81) QSA-1- lush Remote Annunciator Cabinet. Space for one SL30 display card. 4.0 (1.81) Programming Tools QS-CU QuickStart Panel Configuration Utility. QS-Scan QuickStart scanner and programming guide. 2.0 (0.91) 260097 Programming cable (PC to QSC, QS1, QS4) 360136 Programming cable (PC to Annunciators) 240507 DB9 to R-11 ( required with 360136) Accessories PT-1S SystemPrinter - Desk top Style 14.0 (6.35) BC-1(R) Battery Cabinet. Room for one 40 Ah or two 24 Ah batteries. 22.0 (9.98) C-A ultiunction Cabinet. 7.0 (3.1) OP3A RS-232 solator odule. 3.0 (1.36) RP Reverse Polarity odule. 3.0 (1.36) 2-CT City Tie odule. AP-8/232E Alphanumeric Pager nterface. 1 (5.0) BPS6 6.5 Amp Booster Power Supply, 110 V 13.0 (5.9) BPS10 10 Amp Booster Power Supply, 110 V 13.0 (5.9) CDR3 PSN Coder odule t is our intention to keep the product information current and accurate. We can not cover specific applications or anticipate all. All specifications are subject to change without notice. or more information or questions relative to this Specification Sheet, contact EST nternational. 2001 EST Printed in Canada Page 6 of 6 Literature Sheet #85005-0113 ssue 3