Sprinkler Solutions for Storage Applications

Similar documents
Box-in-Box Cold Storage Fire Protection Options

STORAGE FIRE PROTECTION SPRINKLERS

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Simple On The Outside...

Tyco Fire Valves Pure Performance

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

AESTHETIC SPRINKLERS.

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

Sprinkler Identification Numbers

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Storage Sprinkler U.S. Quick Reference Guide

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR-25 Early Suppression, Fast Response Pendent Sprinklers 25.2 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

esfr pendent sprinkler vk510 (k25.2)

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

TECHNICAL DATA NOTICE

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

Fire Protection Products Technical Data Book Table of Contents, August 2017

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Residential Fire Protection Sprinklers & Systems

Water Mist Fire Suppression

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

TECHNICAL DATA OBSOLETE

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

The Effect of Large Orifice Sprinklers on High-Challenge Fires

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

esfr pendent sprinkler vk510 (k25.2)

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

STORAGE PRODUCT BROCHURE

Warehouse Protection of Exposed Expanded Group-A Plastics with Electronic Sprinkler Technology

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Submittal Packages Detailed with Items and Reviewers

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Tire Storage. Michigan Fire Inspectors Society Fall Conference

High Ceiling Protection

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Worldwide Contacts.

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Connected: Global protection, all together

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Sprinkler Identification Numbers

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

esfr dry pendent sprinkler Vk502 (k14.0)

Worldwide Contacts.

Sprinkler Identification Numbers

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

Sprinkler Standards Proposed Technical Changes

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Early Suppression Fast Response Sprinklers and Obstructions

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

High-Piled Combustible Storage

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

NFPA Edition. NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s. Highlights of 2016 Changes. Storage Commodity Classification 4/29/2014

Sprinkler System Installer Level 2

Today's Topics & Sustainability Themes

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

Transcription:

Sprinkler Solutions for Storage Applications

Logistics and Distribution As storage facilities and their distribution methods have evolved, so have the challenges of protecting them. When installing a fire protection system in these spaces, different risk levels must be considered for a custom solution designed to meet the long term needs of the facility. Temperatures 40 F (4 C) and above Temperatures 40 F (4 C) and below Ceiling Heights Model ESFR-25 Highest ceiling-only protection available for protection of cartoned unexpanded plastics QUELL Highest ceiling-only protection available for protection of Class 3 Commodities 48 ft. (14,6 m) Model ESFR-25 Highest ceiling-only protection available for exposed unexpanded and exposed expanded plastics Model ESFR-17 Dry Type Sprinkler Highest ceiling-only protection available for cartoned unexpanded plastics in box-in-box construction 40 ft. (12,2 m) Model EC-25 Low installed cost from extended coverage and low hydraulic demand QUELL Highest ceiling-only protection available for protection of cartoned unexpanded plastics in structural construction 35 ft. (10,5 m) / 2 / Tyco Fire Protection Products

Tyco Fire Protection Products has the experience to provide the right solution for your fire protection needs. In addition to water-based storage solutions, Tyco has a wealth of experience from automatic fire detection and fire suppression systems to hand held portable extinguishers. At Tyco, we use our expertise to recommend long-term solutions which maximize protection for a variety of storage or distribution facilities, including, warehouses, distribution centres, fulfilment centres, cold storage, and automated facilities. Model ESFR-25 - - 48 ft. (14,6 m) ceiling-only storage protection achieve the clear heights needed for tomorrow s facilities Allows greater storage arrangement flexibility change how contents are stored to maximize use of the cube Protection for a wide variety of commodities allows the storage contents and tenants to be changed without replacing the fire protection system Model EC-25 - - 196 ft 2 (18 m 2 ) storage protection almost double the coverage area offered by standard coverage sprinklers Upright design has more favorable obstruction rules Suppression performance with low water demand compared to most alternatives Model ESFR-17 Dry Type - - Cold storage protection with standard wet system piping minimizes installation and maintenance costs Threaded and grooved inlet provide maximum choice for quick installation Two temperatures provides maximum installation flexibility QUELL Systems - - 48 ft. (14,6 m) ceiling-only storage protection with ULTRA K-17 means lower operating costs than alternatives Protection of Class I through Cartoned Group A Plastics allows a wide range of cold storage commodity protection Less repair and downtime no in-rack sprinklers to damage and discharge water Model DPV-1 Dry Pipe Valve - - Sprinkler system valve for environments exposed to freezing temperatures Simple external reset simplifies installation and service Use with Tyco sprinklers for a total fire protection solution Model DV-5 Deluge Valve - - Quick opening, hydraulically operated, valve designed for use as an automatic water control valve in deluge, preaction and specialist fire protection systems, Fewer moving parts than other deluge valves means lower operating costs Simple external reset simplifies installation and service; can be configured remotely VIZOR Electronic Dry Pipe Accelerator (US only) Quick-opening device intended to reduce the operating time of dry pipe valves Less business impact quick installation, faster reset after inspection, and reduced risk of false trips Model QRS Electronic Accelerator Quick opening device intended to reduce the operating time of a dry pipe valve in a dry pipe system or a deluge valve in a double interlock electric / electric preaction system - - One Releasing Panel can control up to four dry pipe systems or one double interlock preaction system www.tyco-fire.com/storage / 3 /

Warehouses, Distribution and Fulfilment Centres Tyco offers solutions for a wide variety of logistics and distribution facilities. The most effective protection solution will be based on multiple factors, including building design, type of commodity, ceiling height and storage arrangement. Fire Protection Challenges Increased fire risk fire can grow larger and faster due to changes in logistics and supply chain strategies that have resulted in storage areas over 1,000,000 ft 2 (93,000 m 2 ) with ceiling heights approaching 50 ft. (15,2 m) With short product life-cycles and tenant changes, the products stored tomorrow will be different than today and you need help with protection for this ever-changing range of products Tyco Solutions // Early Suppression, Fast Response (ESFR) Sprinklers provide help in protecting a wide variety of commodities and storage arrangements, making them a versatile, long-term choice to meet changing needs over the lifetime of a space // Extended Coverage (EC) sprinklers help protect a larger coverage area and combined with minimal hydraulic demand can lower the cost of installation Increased amount of plastics from product, packaging and transport create higher fire hazards / 4 / Tyco Fire Protection Products

Model ESFR-25 Model EC-25 The Model ESFR-25 provides suppression mode performance with ceiling-only fire protection for a wide range of commodities and storage arrangements. These capabilities provide owners with the ability to lease to a wide range of occupiers. This sprinkler is the ideal solution to help protect a space where the commodity type may change during the life of the building. The Model EC-25 upright sprinkler is an Extended Coverage sprinkler designed for 196 ft 2 (18 m 2 ) coverage area. This sprinkler has a fast response element and larger water droplets for high performance fire suppression while introducing a third variable, spacing above the 12 ft (3,7 m) maximum allowed for standard coverage sprinklers. The Model EC-25 has been tested to deliver suppression performance at design criteria as low as six sprinklers. With such a small number of sprinklers operating, combined with suppression performance, total system water can be significantly reduced. www.tyco-fire.com/storage / 5 /

Cold Storage Tyco offers solutions for the challenging environmental conditions found in cold storage facilities. The most effective protection solution will be based on various factors: the construction technique, be it box-in-box or a fully refrigerated warehouse, type of commodity, ceiling height, and storage arrangement. Fire Protection Challenges Wide range of temperatures from 40 F (4 C) down to -60 F (-51 C) is a challenge for water-based fire protection as temperatures move further below freezing, product options narrow and differ from higher temperatures In-rack sprinklers can be broken and discharge water into the space, resulting in expensive clean-up, repair and return to operation Tyco Solutions // Ceiling-only protection can reduce the risk of broken sprinklers and accidental water discharge // The Tyco QUELL System provides the highest ceiling-only solution available for cold storage protection. Now protecting up to 48 ft. (14,6 m) with the ULTRA K-17 // Early Suppression, Fast Response (ESFR) dry pendent sprinklers for box-in-box construction provide simpler installation and maintenance / 6 / Tyco Fire Protection Products

QUELL Systems The Tyco QUELL System is a cold storage fire protection solution for unheated and cold storage warehouses and distribution centers. Compared to in-rack sprinklers, QUELL delivers higher performance and greater flexibility you can stock more commodity classifications, achieve higher roof and storage heights, and have more storage configuration options. Additionally, the QUELL system offers a lower total cost of ownership than in-rack sprinklers, thanks to reduced installation and maintenance costs associated with ceiling-only fire protection. Model ESFR-17 Dry-Type Sprinkler The Tyco Model ESFR-17 Dry-Type Sprinkler is an easy to install, cost-effective solution for box-in-box cold storage facilities. The Model ESFR-17 Dry-Type sprinkler offers installation savings, less maintenance and less chance of damage compared to in-rack sprinklers, which are susceptible to accidental breakage and discharge. The two temperature ratings allow installation flexibility by using the intermediate temperature sprinklers near heat sources such as automatic defrost units. Model DPV-1 Dry Pipe Valve The Tyco Model DPV-1 dry pipe valve is available as a fully assembled, pre-tested solution that can reduce installation time, cost and risk. With its simple external reset, the valve can be tested during routine maintenance and returned to operation quickly, reducing business impact. www.tyco-fire.com/storage / 7 /

Automated facilities Tyco offers solutions for the increasing heights and dense storage configurations found in semi and fully automated facilities Fire Protection Challenges The expanded storage density and heights increase the potential size and growth rate of fires Narrower aisles between storage racks make it more difficult to get water to the base of the fire and can increase likelihood that a fire will move from one side of an aisle to the other Tyco Solutions // A combination of ceiling and traditional in-rack protection control the fire regardless of the commodity and rack type // Multiple levels of ESFR sprinklers installed in the racks minimize the number of levels of in-rack sprinklers with open-frame racks The automated system presents potential ignition hazards and may obstruct detection or suppression equipment from targeting the seat of a fire. / 8 / Tyco Fire Protection Products

Model ESFR-25 Model TY-FRB The Model ESFR-25 provides a combined solution for automated facilities. Installed in the ceiling and in open-frame racks, it helps protect a wide variety of commodities in an environment with heightened risk of fire. The Model TY-FRB is a compact design ideal for use as an in-rack sprinkler. In-rack sprinklers in automated facility fire protection solutions help meet the unique challenge of protecting commodities in narrow, highly obstructed spaces. www.tyco-fire.com/storage / 9 /

Application Overview Commodity Storage Type Model ESFR-25 Model EC-25 QUELL Model ESFR-17 Dry Type Palletized, Solid Piled storage of Class 1 through Class III Commodities UL Specific Application Listing Performance based design Palletized, Solid Piled storage of Class IV Commodities and cartoned unexpanded plastic UL Specific Application Listing Performance based design Palletized, Solid Piled storage of exposed unexpanded plastic Palletized, Solid Piled storage of cartoned and exposed expanded plastic Open frame rack storage of Class 1 through Class III Commodities UL Specific Application Listing Performance based design Open frame rack storage of Class IV Commodities and cartoned unexpanded plastic UL Specific Application Listing Performance based design Open frame rack storage of exposed unexpanded plastic Open frame rack storage of cartoned expanded plastic Open frame rack storage of exposed expanded plastic / 10 / Tyco Fire Protection Products

Commodity Storage Type Model ESFR-25 Model EC-25 QUELL Model ESFR-17 Dry Type Idle Pallet Rubber Tire Storage of Aerosol Products Ignitable liquid Storage Record Storage Roll Paper Storage Rolled Nonwoven Fabric Carpet Storage Automotive Components in Portable Racks Non-Storage Applications www.tyco-fire.com/storage / 11 /

WORLDWIDE HEADQUARTERS Tyco Fire Protection Products, 1400 Pennbrook Parkway, Lansdale, PA, 19446, USA Tel: +1 215-362-0700 / 1 800-558-5236 www.tyco-fire.com EUROPE Kopersteden 1 Enschede, Overijssel 7547 TJ The Netherlands +31 (0) 53 428 4444 MIDDLE EAST Internet City, Office Park Building, Block D, Floor 3 Dubai, United Arab Emirates +971 4455 0700 ASIA PACIFIC 2 Serangoon North Avenue 5 #07-01 Singapore 554911 +65 6577 4360 Copyright 2015, 2016 Tyco Fire Products LP. All rights reserved. TYFENSTOR