ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

Similar documents
Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Class 1 laser beam sensor safe for your eyes

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning. Sensor. Ensure productivity. Emergency stop.

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

Ionizer (Static Remover) STABLO-EX Instruction Manual

Laser Collimated Beam Sensor

Improved productivity Two-stage detection

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

ZJ-FA10. Advanced Ionizer with Visible Discharge Status. Ionizer (Advanced Fan Type) Features. Sensing Charge and Discharge Status

Improved productivity Two-stage detection

ELIMINOSTAT DC-ESR-CL-S2

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

Datasheet: K-22 LO Sensor

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Doc. No. IZ -OMK0015 OPERATION MANUAL PRODUCT NAME: MODEL:

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

OPERATION INSTRUCTION

Ioniser Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Flameproof Type Light Curtain Type 4

E3M-V. Mark Sensor. Applications

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Instruction Manual STATIC ERASER TOP FAN. Table of Contents

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

General terms and conditions... F-7 Glossary of terms... P.1455~ panasonic.net/id/pidsx/global

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

Chargebuster Ion Gun Installation, Operation and Maintenance

DESCRIPTION OF THE APPLIANCE SAFETEY OPERATION CAUTION MAJOR COMPONENTS. Features

Danfoss gas detection units

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

ORDER GUIDE. 5 m ft cable length type. Accessories. Robust Photoelectric Sensor RX SERIES

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Danfoss gas detection units

Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections:

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

Engineering Guideline. pac- Carriers Type Universal

Chargebuster Ion Gun Installation, Operation and Maintenance

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

Hand Dryer Installation & User Manual

USE & CARE INSTRUCTIONS

Operating Instructions

INSTALLATION AND OPERATIONS MANUAL

Work-Shed Vac 1100 Watt

Snifter ATEX22 VERSION. User Manual. Distributor

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Product Data Sheet 4114 N/17HH-218. The engineer's choice

IONIZING AIR BLOWER INSTRUCTION MANUAL

Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference.

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Proposal of suitable static control device for your application.

Vacuum cleaner Instruction manual

General Specifications

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

Instructions for the fan motor control system, SILVER C

Long Life AC Axial Flow Fans MRE Series

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

Operating Instructions. Model No. EH-NE22/EH-NE11. English 7. (Household) Hair Dryer

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series

GLEB Kitchen exhaust fan

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

Bench Top Ionizer Installation, Operation and Maintenance

PHOTOELECTRIC AMPLIFIER SERIES

PJ130S High Pressure Cleaner

CYCLONIC VACUUM CLEANER USER GUIDE MODEL : BGC2000

INSTRUCTION MANUAL DAT-6.16C, DAT-12.33C, DAT-12.33DC, DAT-24.68DC DX-28.65C

Technical Data. Dimensions

ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au WHAT S IN THE BOX. Electric Air Pump. 3 x Inflation Adaptors

GENANO AIR PURIFICATION TECHNOLOGY

REVO JOB INSTALLATION AREA. REVO Job SELECTION TABLE MAIN FEATURES OF THE PRODUCT PROFESSIONAL. CE marking. Automatic filter cleaning

Operating Instructions

Test Unit GTL 100 for Fire Detectors

Two-Channel Gas Controller

Installation manual Mini Comfort 50 S/L 07/ V EN

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

Sensor unit MC2 with analog output for Freon gases and refrigerants

Multifunction. Vax model number:

Transcription:

117 Wide-area Ionizer Steady-state DC Method SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.191 No compressed air necessary guide... P.11~ General precautions... P.19 MEASURE panasonic.net/id/pidsx/global Slim in shape, Wide in charge removal area, An evolutionary form in expression Safe design A monitoring function stops discharge operation if any foreign material or object is detected in the discharge unit. This capability provides peace of mind when working with the unit since you can rest assured that the high-voltage circuit will stop if your finger approaches the unit. (Illustration) Available quiet fan cover (optional) An available fan cover reduces fan suction noise without reducing air volume. Flexible layout Thanks to its space-saving design, the series delivers a sufficiently large charge removal area while allowing you to make effective use of your workspace. It can be mounted on a shelf or pipe or placed directly on the working surface. The unit adapts flexibly to the local working environment. Easy maintenance Discharge units can be removed with a single touch, making it easy to clean them or replace them as they naturally wear down. Units can also be cleaned with a commercially available ultrasonic cleaner. Overhead Desktop

Wide-area Ionizer SERIES 1176 APPICATIONS Front Indicators showing operation conditions This section will now explain the indicator lights that indicate such abnormalities as maintenance time of the discharge needle unit and the decrease in the amount of ventilation due to filter clogging. POWER (Green ED) ERROR (Red ED) CHECK (Orange ED) Airflow adjustable in 4 levels Fan speed can be adjusted in 4 levels. By setting the fan speed to MAX, speedy static removal of wide area is possible. N (Yellow ED) BAR (Yellow ED) Overhead Desktop ERROR indicator: ights up when an intrusion of a foreign object into the discharger is detected by the entry detection function, or when an abnormal discharge, air intake constraint caused by clogged filter, or any other abnormality of the fan is detected. CHECK indicator: ights up when it is time for maintenance of the discharge needle unit, or when a drop in the fan speed resulting from filter clogging is detected. N indicator: ights up when a fan error or a fan check is detected. BAR indicator: ights up when a discharger error or a discharger check is detected. Easy filter cleaning The fan air intake filter can be easily taken out by sliding open the cover. This greatly reduces the man-hour in cleaning. MEASURE Silent fan cover (option) is available. Without decreasing the airflow, it is possible to reduce noise during fan suction. You can easily attach the silent fan cover to the front of the main unit fan with a single step. Silent fan cover (optional) SC

1177 Wide-area Ionizer SERIES ORDER GUIDE Ionizer main unit Type Appearance (±1, V ± V) Ion balance Model No. 4-EX Wide-area fan type 1 sec. approx. (Note 1) ± V or less (Note 2) Notes: 1) Typical value at mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed. 2) Typical value at mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed. 3) Please prepare an AC cable separately as it is needed. The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KT) Connector configuration (IEC 63 C7) 6-EX 8-EX Designation Model No. Description Mounting unit 6MS1 Silent fan cover SC AC cable CN-ACCN-C2 CN-ACKR-C2 Mounting unit 6MS1 AC cable (conforming to CCC), ength: 2 m 6.62 ft AC cable (conforming to KT), ength: 2 m 6.62 ft Mounting unit for 6-EX. Allows easy attachment or detachment of the main unit. Air filter F Discharge needle unit Air filter F Air filter for fan air intake part ( pcs. per set) ANT Discharge needle unit ANT Unit with tungsten needles (1 pc.) Silent fan cover SC To be mounted on the front part of the fan unit as a cover to reduce the fan blowing sound.

Wide-area Ionizer SERIES 1178 SPECIFICATIONS Type Wide-area fan type Item Model No. 4-EX 6-EX 8-EX CE marking directive compliance EMC Directive, RoHS Directive (±1, V ± V) 1 sec. approx. (Note 2) Ion balance ± V or less (Note 3) Ozone generation.2 ppm or less (Note 3) Power supply voltage Power consumption Accessory AC adapter input: -24 V AC ± % /6 Hz (Note 4) (Output: 24 V DC) 8 VA or less (at V: 7 VA or less) Discharge method Discharge output voltage Error output Indicators Output operation Short-circuit protection Bar Fan POWER ERROR CHECK Discharge part status Fan status Steady-state DC ±6, V approx. NPN open-collector transistor Maximum sink current: ma Applied voltage: V DC or less (between output and V) Residual voltage: 1 V or less (at ma sink current) OFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON Incorporated Green ED (ights up when the power is ON) Red ED (ights up when discharge part error or fan error is detected) Orange ED (ights up when discharge part check or fan check is detected) Yellow ED (ights up when discharge part error or discharge part check is detected) Yellow ED (ights up when fan error or fan check is detected) Ambient temperature to + C +32 to +122 F (No dew condensation), AC adapter: to +4 C +32 to +4 F Ambient humidity Material 3 to 6 % RH (No dew condensation allowed) Bar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: Cold rolled carbon steel (SPCC) Weight Net weight: 1. kg approx. Net weight: 1.2 kg approx. Net weight: 1.4 kg approx. Accessories AC adapter (Note 3), F.G. connection cable: 1 pc., Spare replacement filters: pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of + C +68 F. 2) Typical value at mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed. 3) Typical value at mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed. 4) Please prepare an AC cable separately as it is needed. The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KT)

1179 Wide-area Ionizer SERIES I/O circuit diagram Main circuit I/O CIRCUIT AND WIRING DIAGRAMS Tr D Internal circuit ZD 4 6 +V V AC adapter (Accessory) F.G. terminal [connected internally to V and COM ( ).] Error output oad 2 ma max. COM ( ) 3 + AC cable (Note) V DC or less Note: Please prepare an AC cable separately as it is needed. The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC) CN-ACKR-C2: AC cable (conforming to KT) Symbols D : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr : NPN output transistor Terminal position Terminal No. Terminal name 1 N.C. (no connection) 2 Error output 3 COM ( ) 4 V +V 6 F.G. 1 2 3 4 6 (sec.) (sec.) (sec.) CHARGE REMOVA CHARACTERISTICS (TYPICA) Measured using a mm.96.96 in (charge plate monitor). (At center of ) 4-EX 4 3 2 1 6-EX 4 3 2 1 8-EX 7.874 1.748 4 23.622 6 8 14 16 31.496 39.37 47.244.118 62.992 Charge removal distance (mm in) 7.874 1.748 4 23.622 6 8 14 16 31.496 39.37 47.244.118 62.992 Charge removal distance (mm in) 4 3 2 1 7.874 1.748 4 23.622 6 8 14 16 31.496 39.37 47.244.118 62.992 Charge removal distance (mm in) Correlation between charge removal distance and ion balance 7.874 1.748 4 23.622 6 31.496 8 14 16 39.37 47.244.118 62.992 Charge removal distance (mm in) Correlation between charge removal distance and ion balance 7.874 1.748 4 23.622 6 31.496 8 14 16 39.37 47.244.118 62.992 Charge removal distance (mm in) Correlation between charge removal distance and ion balance 7.874 1.748 4 23.622 6 31.496 8 14 16 39.37 47.244.118 62.992 Charge removal distance (mm in) Charge removal field (Horizontal direction) 4 1.748 11.811 7.874 3.937 - -3.937 - -7.874 - -11.811 W -4 4 -Direction -1.748 14 16 7.874 1.748 23.622 31.496 39.37 47.244.118 62.992 Charge removal distance (mm in) Charge removal field (Horizontal direction) 4 1.748 11.811 7.874 3.937 Charge removal field (Horizontal direction) 4 1.748 11.811 7.874 3.937 2 sec.() sec.() sec.() 2 sec.() sec.() sec.() 2 sec.() sec.() sec.() 2 sec.() sec.() sec.() - -3.937 - -7.874 - -11.811 W -4 4 -Direction -1.748 14 16 7.874 1.748 23.622 31.496 39.37 47.244.118 62.992 Charge removal distance (mm in) 2 sec.() sec.() sec.() 2 sec.() sec.() sec.() - -3.937 - -7.874 - -11.811 W -4 4 -Direction -1.748 14 16 7.874 1.748 23.622 31.496 39.37 47.244.118 62.992 Charge removal distance (mm in) Ion balance (Horizontal direction) [] Charge removal distance (mm in) = mm 11.811 in = mm 19.68 in = mm 39.37 in W -Direction -4-1.748-11.811 - -7.874-3.937-4 3.937 7.874 11.811 1.748 Ion balance (Horizontal direction) [] Charge removal distance (mm in) = mm 11.811 in = mm 19.68 in = mm 39.37 in W -Direction -4-1.748-11.811 - -7.874-3.937-4 3.937 7.874 11.811 1.748 Ion balance (Horizontal direction) [] Charge removal distance (mm in) = mm 11.811 in = mm 19.68 in = mm 39.37 in W -Direction -4-1.748-11.811 - - - 4-7.874-3.937 3.937 7.874 11.811 1.748

Wide-area Ionizer SERIES 118 PRECAUTIONS FOR PROPER Refer to p.19 for general precautions. Mounting mm 3.937 in This product is to remove static electricity for industrial use. Never use this product for medical equipment etc. relating to maintenance / supervision of human life or body, for prevention of accidents which damage a human life or properties, or for safety maintenance. Do not use this product near or around surroundings containing any dangerous materials, such as combustible material and flammable material. This product emits ozone. In order for this product to be used in an airtight room, be sure to keep the room ventilated. Do not place any objects that may obstruct the inflow of air within mm.394 in of the front of the fan air intake part. Doing so may cause accident or product malfunction. Be sure to ground the main body of this product via ground terminal to ensure electrical shock prevention and reliable charge removal. Since the charge needle is applied with high voltage, never touch the discharge needle, or an electric shock may result. Since the tip of the discharge needle is sharp, take sufficient care in handling the discharge needle, or injuries may result. Do not place any objects or any other charge removal equipment within mm 3.937 in of the ionized air outlet front (refer to the illustration below), as they may affect operation and performance of the ionizer. 4 4 Forbidden zone Air outlet mm 3.937 in DIMENSIONS (Unit: mm in) -EX Ionizer Air outlet 4 4 Forbidden zone C D F Maintenance Always be sure to turn off the power before carrying out any care and maintenance of the product. The tip of the discharge needle is sharp, so be careful not to touch it while cleaning. When the product is used for long periods of time, dust and other foreign particles may accumulate on the discharge needle, the area around it, and on the fan filter. Clean regularly (discharge needle: about once a week, air filter: about once every two months), otherwise their charge removal performance will drop and operating problems or accidents may occur. The discharge needle is a consumable part. If the charge removal performance is not restored after cleaning the discharge needle, the discharge needle unit should be replaced. All of the discharge needle units should be replaced at the same time. The CAD data can be downloaded from our website. 1..6..217 Ionizer 47 48 1.8 1.89 6 2.362 Discharge needle holder Model No. A B C D E F G 4-EX 16.299 414 9.449 24 13.839 31. 11.417 29 7.48 19.39 2 4.724 1 6-EX 22.98 74 1.748 4.138 11. 17.717 4 13.78 4 1.748 11.24 28 8-EX 28.898 734 22.47 6 26.437 671. 24.16 6.79 22.47 6 17.323 44 Air outlet G E (A) B 4..177 8 3. (4.18) 12.472 4.3 1.784 Power indicator (Green) Error indicator (Red) Check Indicator (Orange) Air inlet Fan speed switch 61 2.42 4-M4 (thru-hole) 4-M (thru-hole) ( 1.969) 92.2 3.6 98 3.88 ( 3.937) 8.3.327 44 1.732 143.6 43. 1.713 24.94 Mounting bracket Power connector Power switch Discharger status indicator (Yellow) Fan status indicator (Yellow)