Air Conditioning Catalogue. RAC Room Air Conditioning

Similar documents
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Wall Mounted. More information on controls and options on pages

Wall Mounted. More information on controls and options on pages

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

What do I need for my bedroom?

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

FREE MULTI SYSTEM Z R32 GAS. NEW FREE MULTI SYSTEM Z Up to 5 indoor units with a single outdoor unit R32 NEW REFRIGERANT GAS

TECHNICAL CATALOGUE MONO SPLIT RAK-18PED RAC-18WED RAC-25WED RAC-35WED RAC-X10/14EAG RAC-L10/14EAG RAC-M25/35EAG

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Heat Pump Air Conditioning Systems

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Cassette. More information on controls and options on pages

Product Brochure Smart Power. Low Profile Ducted

MULTI-INVERTER AIR CONDITIONERS

Air Conditioners Heating & Cooling

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

SIMPLICITY OR FULL MODULARITY?

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Inverter console UFV system. Compact design and personalised air flow selection

Do you want a versatile solution

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Consumer Guide. Split System: Wall Mounted Inverter Heat Pumps

Monozone/Multizone (NH5, QH5) Summit (YH5) Bigflow (G4, GH4) Technical Catalogue

Air conditioners Heating & Cooling

Hitachi Inverter Wall Split Air Conditioning

Daikin leads the way:

Hi-spec Design model. Photo : LT series

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

MONO & MULTI SPLIT AIR CONDITIONERS

Air to air heat pump range. Why Vaillant? because there is something in the air.

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

Q Series. Inverter Split Systems

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

A single answer for multiple zones.

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Product Line Introduction. Karl Zhang Technical support engineer

Product Brochure 2017

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Split System Air Conditioning

Air conditioners Heating & Cooling

G Series Inverter Split Systems

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

PAC BT LOW TEMPERATURE HEAT PUMP

SHORAI. hatever you need. Do you want to improve your quality of life?

for your home FLXS-B Flexi type unit air to air heat pumps

Inverter High Wall MSZ-GE Series

ACCESSIBLE COMFORT RESIDENTIAL

A single answer for multiple zones.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

HI-WALL SPLIT SYSTEMS

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

AIR CONDITIONERS, HEATING & COOLING for your home

Model: Ceiling Cassette V 9k-24k

SIMPLICITY FULL MODULARITY?

Air Conditioners Heating & Cooling

HEAT PUMPS SiOS SYSTEM TERMINAL UNITS UNICO FIXED AIR CONDITIONERS PORTABLE AIR CONDITIONER AIR COOLER VMC DEHUMIDIFIERS HUMIDIFIERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Air Conditioners Heating & Cooling

Residential and Light Commercial Ductless Systems Catalog

ASTRALPOOL HEAT PUMP CATALOGUE

Air Conditioners Heating & Cooling

PRODUCT LINE-UP Residential & Light Commercial air conditioners

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Call or visit solarshop.com.au

Split System Air Conditioning

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Split System AIR CONDITIONING RANGE. Australians love a Kelvinator

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-15QPB RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Specifications, Performance & Submittal

Inverter Wall Mounted Series

Inverter Ducted Air Conditioners

Air Conditioners Heating & Cooling

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Air Conditioners Heating & Cooling

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Air Conditioners. Summer

Air Conditioners Heating & Cooling

Air conditioners, heating & cooling for shops,restaurants and offices

Advance Split

Ducted inverter reverse cycle air conditioning

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Wall Mounted. More information on controls and options on pages

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

Transcription:

Air Conditioning 2015 Catalogue RAC Room Air Conditioning

www.hitachi.com

2015 Catalogue RAC This is Hitachi page 04 ErP design page 08 Technology page 10 Products RAC Mono page 15 RAC Multi page 35 Product comparison page 48 Functions page 50 Quality certifi cations page 55

RAC 4

Meet MIRAI RAC Residential My name is MIRAI and I will be your guide in the world of HITACHI air conditioning. The word MIRAI means FUTURE in Japanese and I represent HITACHI's ability to predict in advance customers' needs in air conditioning products and solutions. HITACHI's work philosophy is founded exactly on this principle: every year we invest a portion of our corporate earnings in the research and development of new products in line with the market's exacting demands, yet respecting and safeguarding the environment. With this spirit, our abilities, our ongoing commitment, we have been continuously growing for more than 100 years and we are not going to stop! Confi dent in our solid past but with our eyes fi rmly set on the future... This is HITACHI! I am MIRAI! 5

Company Profile Hitachi Air Conditioning Products Europe - HAPE Production facility - Barcelona, Spain In 2012 HITACHI widened their activities by setting up HITACHI Air Conditioning Europe SAS. HITACHI Air Conditioning Europe encompasses all Air Conditioning operations in the European market, including sales and production. Air conditioning according to HITACHI means more innovative ideas, the most recent technological developments and, together with engineering and quality control processes, producing systems to improve life in a home and professional environment. In producing its range of innovative products, HITACHI has a responsible and environmentally-friendly approach which imbues every activity within the process, from the fi rst design stage of a new product, to production, to installation and operation procedures, guaranteeing products Engineered for tomorrow. HITACHI is committed to supplying products of outstanding quality with the highest efficiency levels and the best cost-effectiveness. Achieving success with such ambitious goals on a global scale does not only involve committing considerable resources, but also implies a bold bet and huge commitment to the future. Among the most prominent companies worldwide, with about 360,000 employees, HITACHI can build on their expertise and knowledge, in the awareness it has been successfully addressing customers' changing needs for more than a century. Our de- 6

RAC Residential sign and development skills are second to none and HITACHI is fi rmly ready to face the future with serenity and confi dence. HITACHI the name means Rising Sun in Japanese is at the forefront in research and development, along a path led by substantial investments. About 4.2% of its worldwide 2010* $112,2 billion turn-over has been invested in research and development programs. This allows HITACHI to boast a wide number of world's fi rst products, such as the acclaimed and technologically advanced scroll compressors and semi-hermetic screw compressors. HITACHI compressors have revolutionised the air-conditioning world. The design process starts in Japan's workshops and production units and is continuously developed via an exchange with the other units worldwide. HITACHI Air Conditioning products are sought after worldwide, whenever there is a need for high-efficiency products with the best price-quality ratio and an extremely long life. The widest product range, matched to an adequate set of electronic controls, allows HITACHI to offer solutions for any application or technical specification. Hitachi Air Conditioning Systems Co., Ltd. - Production facility - Shimizu, Japan The innovative HITACHI production facility and training centre set up in Barcelona, Spain (HAPE) is tailored to the European market. The technologies used afford signifi cant savings in production costs, fast deliveries and prompt support in meeting customers' needs. In addition to the technical support provided by HITACHI Air Conditioning Europe, the local units contribute with their abilities and know-how to supporting customers from design to after-sale service in starting up and controlling systems. The after-sale service relies on a network of selected professionals and an extremely fast support in spare parts. To meet your air conditioning and heating needs and to assure air quality in your en- Hitachi Air Conditioning Products (M) - HAPM Production Facility - Kuala Lumpur, Malaysia vironment, consider HITACHI Air Conditioning Europe as your partner, able to guide you in all air conditioning choices and Inspiring the Next... 7

EcoDesign (E.r.P.) A Directive to address European environmental emission reduction goals Europe has revisited the original EcoDesign Directive (Directive 2005/32/CE) and widened its field of application in order to achieve European 3 x 20 environmental goals (-20% energy consumption, -20% CO2 emissions, +20% renewable energies) by 2020. The initial scope of EcoDesign was E.u.P. (Energy using Products). However, the present scope of EcoDesign encompasses all products that are connected to the use of energy (e.g.: windows, panelling) and it has been more correctly named E.r.P. (Energy related Products). What does EcoDesign mean? EcoDesign means taking into consideration the environmental aspects of every product/service in question. This approach consists in considering CO2 emissions and energy consumption throughout the entire life of the product (from design to end of life, including transport). The application date is 1st January 2013. However, levels (a) and (b) will be increased every year and labelling will be updated every 2 years. The efficiency level (a) refers to seasonal efficiency of the system, called SCOP (heating) and SEER (conditioning) for the average European climate. This efficiency coefficient is going to replace the previous COP and EER values. Table of minimum SCOP/SEER values for compliance Energy rating SEER Energy rating A +++ SEER 8.50 SCOP 5.10 A ++ 6.10 SEER 8.50 4.60 SCOP < 5.10 A + 5.60 SEER 6.10 4.00 SCOP < 4.60 A 5.10 SEER 5.60 3.40 SCOP < 4.00 B 4.60 SEER 5.10 C 4.10 SEER 4.60 D 3.60 SEER 4.10 ErP concerning conditioning and heating systems The EcoDesign analysis highlights that the greatest environmental impact arises from the utilisation period of the products. For this reason, ErP sets minimum compulsory efficiency levels to enter the European market. At the same time, Erp requires the disclosure of technical data to users through a label which must show efficiency data and noise level, with the aim of assisting consumers in their choices. ErP applies to every conditioning and heating system independently from the type (air/air, air/water, water/water, boilers...), capacity, utilisation (heating, conditioning, DHW) via a range of Lots and different time frames. The fi rst Lot in force as of 1st January 2013 is Lot 10. It covers all air conditioners (air/air), with capacity lower than 12kW, operating in conditioning and/or heating. Fundamental aspects of Lot 10 3 fundamental aspects in terms of compliance are described in Directive 2010/30/UE No.626/2011 of 4 May 2011 and in Directive 2009/125/EC No.206/2012 of 6 March 2012. (a) Defi nition of the minimum efficiency level in heating and conditioning (b) Defi nition of the Sound Power level for internal and external unit at nominal conditions (c) Defi nition of the criteria for communication to the user by means of the label Main differences between nominal COP and SCOP : «Nominal COP» defi nes the efficiency of the system in one measuring point: +7 C outside, +20 C inside, compressor at nominal speed. «SCOP» defi nes the system's seasonal efficiency, considering: 5 measuring points: -10 C, -7 C, +2 C, +7 C, +12 C outside, +20 C inside Different compressor speeds (full load and partial load). Ancillary consumptions (oil heater, thermostat off mode, off mode, standby ) Temperature conditions for an identified climate (obligatory average climate, optional hot climate and cold climate) and number of operating hours depending on outdoor temperatures Thermal load of the building (called Pdesign) For these reasons, the SCOP (and SEER) give a more accurate estimate of the actual efficiency of a system throughout the entire time of utilisation. 8

RAC Residential Climate considered by ErP Average Cold Hot Reference temperature T design - 10 C - 22 C + 2 C I II SEER SCOP A B C D E F G kw XY,Z SEER X,Y kwh/annum XY A A B C D E F G A kw XY,Z SCOP X,Y kwh/annum XY B XY,Z X,Y XY C XY,Z X,Y XY ZYdB ZYdB ENERGIA ЕНЕРГИЯ ΕΝΕΡΓΕΙΑ ENERGIJA ENERGY ENERGIE ENERGI 626/2011 http://erpactive.hitachiaircon.com Sound power of the internal and external unit at nominal capacity Yearly Kwh used in cooling and heating mode calculated under the Regulations Note: The manufacturer may choose to declare the data for all zones. The average climate is the only obligatory one. Pdesign = thermal load at the standard design temperature T design. 9

Technology Accessories and connettivity H-LINK Adapter: PSC-6RAD for centralised supervision of Room Air Conditioners All indoor units can be connected with the H-Link adapter (PSC-6RAD) in a single bus according to a communication protocol developed by Hitachi. This accessory makes residential units compatible with systems in the commercial, service industry and industrial range. The basic functions (On/Off, operation mode, set temperature, etc.) are programmable via the H-Link central controller. Compatibility MyHOME Bticino system through RAC Interfaces HC-A(8/64)MB and PSC-6RAD Through interfaces HC-A(8/64)MB and PSC-6RAD Hitachi RAC units are compatible with MyHOME Bticino solution. In this way it is possible to control RAC units remotely via smartphone, tablet and PCs. This is very useful for Hotels and Residential applications. Please contact Hitachi or Bticino for further details. Compatibility with Somfy through RAC Interface Somfy TaHoma (SPX-TAG01) Through interface SPX TAG01 Hitachi RAC units are compatible with Somfy TaHoma solution. In this way it is possible to control RAC and heat pumps units remotely via smartphone, tablet and PCs. Please contact Hitachi or Somfy for further details. 10

RAC Residential Accessories and connettivity Clean contact kit (SPX-WDC1/2/3/4) A clean contact kit is available for all indoor units to enable/disable remote operation. Typical applications are the window contact (the unit is turned off when a window is opened in the room so as not to waste energy) or the electronic key (the unit is turned off when the badge electronic key is removed from its slot). ID Switch When two indoor units are installed close to each other in the same room, the infra-red frequency on the remote controller can be differentiated, to prevent mixing the signals controlling them. ON OFF Distributor of signal (SPX-DST1 + SPX-WDST8M) The optional distributor SPX-DST1 can be used together with the remote controller when there is a need to centralise the control of multiple indoor units using only a single wired remote controller. WIRED REMOTE CONTROLLER First connection DISTRIBUTOR Second connection A single distributor could be connected further to 3 separate distributors so that up to 13 units of indoor could be controlled by a single wired remote controller. DISTRIBUTOR DISTRIBUTOR DISTRIBUTOR For each connected unit one cable SPX- WDST8M (length of 8m) shall be connected. 4 INDOOR UNITS 4 INDOOR UNITS 4 INDOOR UNITS INDOOR UNIT MAX 13 UNITS CAN BE CONNECTED 11

Technology The new infrared remote controller has a variety of available features The new infra-red remote controller, available for a large number of models in the residential range, includes a host of functions to suit your lifestyle and assure the utmost comfort in your home. Its neat and essential design inspired by minimal and elegant aesthetics perfectly matches our air conditioners. All the information on your air conditioner s operation and condition are cle arly laid out on the large LCD display and the pictograms on the function keys make programming easy. A built-in sensor instantly measures your room temperature in any position The new infrared remote controller is equipped with a 7-day timer to suit your utilisation needs. Up to 6 on/off settings may be programmed for each day of the week, from Monday to Sunday. Up to 2 programs may be stored on the remote controller, for instance one valid in summer and the other in winter. The table below provides a programming example. MON TUE WED THU FRI SAT SUN 04:00 ON 18 C ON 18 C ON 18 C ON 18 C ON 18 C 06:00 ON 20 C ON 20 C ON 20 C ON 20 C ON 20 C ON 20 C ON 20 C Switching on at the weekend 08:00 OFF OFF OFF OFF OFF Switching off during working hours 10:00 ON 18 C 12:00 Decrease temperature during 14:00 daytime 16:00 18:00 ON 20 C 20:00 ON 20 C ON 20 C ON 20 C ON 20 C ON 20 C Increase temperature after Switch on before getting home sunset 22:00 ON 18 C ON 18 C ON 18 C ON 18 C ON 18 C ON 18 C ON 18 C Decrease temperature when going to bed 24:00 OFF OFF OFF OFF OFF OFF OFF Switch off during the night 12

RAC Residential Remote controller functions ECO MODE It allows you to keep electricity consumption in check while always assuring fully efficient operation. POWERFUL MODE The system works at maximum power in heating or cooling mode for 20 minutes in order to meet the demand for comfort in the shortest possible time. When the 20 minutes have elapsed the system automatically returns to the initial condition. LEAVE HOME When leaving home for a long period of time in winter, this function prevents the rooms from getting too cold (below 10 C). The duration of the LEAVE HOME function may be set for the desired length of time. When the set period has expired, the unit goes back to operating in the previously set mode. INFO Three different parameters may be displayed with the INFO button. 1. Room temperature: the thermistor fitted in the remote controller lets you view the room temperature on the display. 2. Electrical consumption display: the monthly electrical consumption (current & previous month) may be displayed. 3. Malfunctioning self-diagnosis: in the event of failure, the LCD remote controller displays the error code for easier maintenance. SILENT MODE With the silent mode the sound level of the indoor unit may be lowered with just one touch by changing the fan speed. CLEANING Thanks to this feature the indoor unit will always keep clean and mould growth may be prevented after cooling operation by means of the evaporator s drying action. SLEEP TIMER The countdown timer may be set up to 7 hours duration. The ability to adjust temperature (±2 C) and lower fan speed assures comfortable sleep and considerable energy savings. SPX-RCDB SPX-RCDA WIRED REMOTE CONTROLLER For all RAC indoor units the optional wired remote controller is available: SPX-RCDB (for all indoor units except ducted ones) SPX-RCDA (only for ducted units) Some functions of the IR remote controller are not available for the wired remote controller, but it is always possible to activate them from IR remote controller even if the wired remote controller is installed. 13

RAC Mono 14

RAC Residential RAC Mono INDOOR UNITS example: RAK 25PSB What type of air conditioner? RAK = wall RAF = floor RAI = 4-way cassette RAD = ductable OUTDOOR UNITS example: What cooling capacity? XW = X,Y kw What type of What family of combination? products? P = only mono-split S = Premium Q = only multi-split X = Cut Out / Akebono R = mono and multi-split P = Performance E = Eco Comfort RAC 25WSB What series of products? A = series 1 B = series 2 What type of combination? RAC = only mono-split RAM = only multi-split What cooling capacity? XW = X,Y kw What type of application? W = wall F = floor C = 4-way cassette D = ductable N = universal What family of products? S = Premium X = Cut Out / Akebono P = Performance E = Eco Comfort What series of products? A = series 1 B = series 2 PAM DC INVERTER AIR TO AIR HEAT PUMP UNITS FOR SINGLE ENVIRONMENT High seasonal effi ciency Extremely low Noise Levels Several models and capacities available Both summer and winter mode available A wide choice of units is available, suitable for both classical and modern environments, designed for the maximum comfort in terms of performance and indoor air quality, guaranteeing the maximum energy saving. 15

RAC Mono PREMIUM Wall RAK-PSB PAM DC Inverter Split Heat Pump RAK 18~25~35 PSB Exceptional seasonal efficiency the air conditioner features exceptional efficiency levels both in cooling and heating mode. Exceptional efficiency in heating mode thanks to its exceptional technical features, efficiency in heating mode is aaured up to -20 C and thermal capacity remains unchanged with respect to the nominal value up to -15 C. Eco sensor the motion sensors built into the indoor unit assure a good balance between the desired comfort and energy savings. Comfort airflow always thanks to the motion sensors, you may opt whether to aim the air flow away or at the user Quiet only 22 dba noise level at the SUPER LOW speed for guaranteeing peaceful sleeps. Stainless clean all inner surfaces of the air conditioner are constructed in stainless steel to assure the utmost cleanliness of the treated air, reducing the proliferation of pathogens. Thanks to this material, the air conditioner stays clean for a great many years. Filter clean just press a key on the remote controller, and a brush-fitted robotic arm located on the prefilters automatically cleans the indoor unit. Clean feature the evaporator is dried to prevent mould formation. 7-day timer 6 on/off settings for every day of the week, two storable programs (summer/winter). Leave home the feature lets you set a minimum hold temperature (10 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set Ideal for holiday homes! Info key room temperature reading, power consumption display, alarm signals. Vertical / horizontal swing the air flow is vertically and horizontally orientable from the remote controller thanks to the motorised flaps. + ION MIST ionised water mist particles invisible to the human eye released into the room by an ionised mist device are able to significantly reduce the concentration of bacteria, fungi and pollen in the air. ION MIST device integrated in the indoor unit. 16

RAC Residential +21-20 +43-10 (1) Outdoor unit Unit of meas. RAC-18WSB RAC-25WSB RAC-35WSB Nominal cooling capacity (min - max) kw 1.8 (0.5-2.8) 2.5 (0.5-3.4) 3.5 (0.5-4.1) Nominal heating capacity (min - max) kw 2.3 (0.6-4.8) 3.2 (0.6-5.8) 4.0 (0.6-6.6) Nominal cooling power input (min - max) kw 0.300 (0.070-0.880) 0.470 (0.070-0.960) 0.805 (0.070-1.350) Nominal heating power input (min - max) kw 0.375 (0.065-1.620) 0.570 (0.065-2.250) 0.790 (0.065-2.450) EER / COP 6.00/6.13 5.32/5.61 4.35/5.06 SEER / SCOP average climate 7.41/4.60 8.50/4.68 8.50/4.72 Energy class (SEER/SCOP) A++/A++ A+++/A++ A+++/A++ Cooling sound pressure level db(a) 46 48 49 Heating sound pressure level db(a) 46 48 49 Sound power - Indoor/Outdoor db(a) 60 62 63 Dimensions (H x L x D) mm 600x792x299 600x792x299 600x792x299 Weight kg 40 40 40 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4 / 1/2 1/4 / 1/2 1/4 / 1/2 Minimum piping length m 3 3 3 Max piping length / max lift m 20 / 10 20 / 10 20 / 10 Max pre-charge length / Amount of additional refrigerant m / g/m 20 / - 20 / - 20 / - Working range C -10~43-10~43-10~43 (cooling, heating) C -20~21-20~21-20~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAK-18PSB RAK-25PSB RAK-35PSB Cooling sound pressure level (SL / L / M / H) db(a) 22/28/34/40 22/28/34/42 23/28/34/44 Heating sound pressure level (SL / L / M / H) db(a) 22/30/34/41 22/30/34/42 23/30/34/44 Sound power db(a) 54 56 58 Cooling air fl ow rate (SL / L / M / H) m3/h 260/300/420/ 470 260/320/420/510 270/320/420/520 Heating air fl ow rate (SL / L / M / H) m3/h 260/300/420/540 260/370/520/600 270/410/520/610 Dimensions (H x L x D) mm 295x798x258 295x798x258 295x798x258 Weight kg 12 12 12 Piping diameter (Liq / Gas) inch 1/4" / 1/2" 1/4" / 1/2" 1/4" / 1/2" Condensate drain diameter (ext) mm 16 16 16 Remote controller (standard, optional) Standard RAR-5W1 RAR-5W1 RAR-5W1 Optional SPX-RCDB SPX-RCDB SPX-RCDB Filter Optional Wasabi SPX-CFH22 Wasabi SPX-CFH22 Wasabi SPX-CFH22 Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 Standard Pre-fi lter Stainless Steel Micro Mesh Stainless Steel Micro Mesh Stainless Steel Micro Mesh (1) with motion sensor and presence sensor 17

RAC Mono AKEBONO Wall RAK-RXB PAM DC Inverter Split Heat Pump RAK 25~35~50RXB Elegant design a new range whose minimal design features are enhanced by high quality materials. Eco sensor the motion sensor built into the indoor unit assures a good balance between the desired comfort and energy savings. Wasabi Nano Titanium the WASABI NANO TITANIUM air filter supplied guarantees the high quality of the air you breathe in your room. Stainless clean the inner surface of the air flow outlet and prefilters are constructed in stainless steel to assure the utmost cleanliness of the treated air, reducing the proliferation of pathogens. Thanks to this material, the air conditioner stays clean for a great many years. Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating mode up to -15 C. Super quiet only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps. Vertical / Horizontal Swing the air flow is vertically and horizontally orientable from the remote controller thanks to the motorised flaps. 7-day timer 6 on/off settings for every day of the week, two storable programs (summer/winter). Leave Home the feature lets you set a minimum hold temperature (10 C-16 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! Info key room temperature reading, power consumption display, alarm signal. Clean function the evaporator is dried to prevent mould formation. 18

RAC Residential +21-15 +43-10 SAME INDOOR UNITS COMPATIBLE WITH MONO/MULTI OUTDOOR (1) Outdoor unit Unit of meas. RAC-25WXB RAC-35WXB RAC-50WXB Nominal cooling capacity (min - max) kw 2.50 (0.90-3.10) 3.50 (0.90-4.00) 5.00 (1.90-5.20) Nominal heating capacity (min - max) kw 3.20 (0.90-4.20) 4.00 (0.90-4.80) 5.80 (2.2-7.00) Nominal cooling power input (min - max) kw 0.545 (0.25-1.22) 0.910 (0.25-1.40) 1.560 (0.50-2.10) Nominal heating power input (min - max) kw 0.700 (0.25-1.20) 0.955 (0.25-1.60) 1.560 (0.50-2.70) EER / COP 4.59/4.57 3.85/4.19 3.21/3.72 SEER / SCOP average climate 8.50/4.70 8.50/4.72 7.20/4.50 Energy class (SEER/SCOP) A+++/A++ A+++/A++ A++/A+ Cooling sound pressure level db(a) 46 47 51 Heating sound pressure level db(a) 47 49 51 Sound power - Indoor/Outdoor db(a) 60 61 65 Dimensions (H x L x D) mm 548 750 288 548 750 288 736 800 350 Weight kg 34 34 49,5 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Minimum piping length m 3 3 3 Max piping length / max lift m 20 / 10 20 / 10 30 / 10 Max pre-charge length / Amount of additional refrigerant m / g/m 20/- 20/- 30/- Working range C -10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAK-25RXB RAK-35RXB RAK-50RXB Cooling sound pressure level (SL / L / M / H) db(a) 20/26/32/40 22/29/35/42 25/31/39/47 Heating sound pressure level (SL / L / M / H) db(a) 20/27/33/40 22/30/35/42 25/31/39/48 Sound power db(a) 55 60 60 Cooling air fl ow rate (SL / L / M / H) m3/h 300/330/510/560 320/340/430/580 350/400/580/720 Heating air fl ow rate (SL / L / M / H) m3/h 290/370/560/610 310/360/480/630 350/420/620/800 Dimensions (H x L x D) mm 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210 Weight kg 11 11 11 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter (ext) mm 16 16 16mm Remote controller (standard, optional) Standard RAR-6N1 RAR-6N1 RAR-6N1 Optional SPX-RCDB SPX-RCDB SPX-RCDB Filter Optional Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 Standard Pre-fi lter Stainless Steel Stainless Steel Stainless Steel (1) with presence sensor 19

RAC Mono PERFORMANCE Wall RAK-RPB / RAK-PPA PAM DC Inverter Split Heat Pump RAK 18~25RPB RAK 35~50RPB RAK 60PPA RAK 70PPA Wide range available in 6 power levels from 1,8kW to 7kW in cooling mode to adapt to a wide range of different needs. Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating up to -15 C. Wasabi Nano Titanium the WASABI NANO TITANIUM air filter supplied guarantees the high quality of the air you breathe in your room. Vertical / Horizontal Swing the air flow is vertically and horizontally orientable from the remote controller thanks to the motorised flaps. 7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). Leave home the feature lets you set a minimum hold temperature (10 C-16 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! Info key room temperature reading, power consumption display, alarm signal. Clean function the evaporator is dried to prevent mould formation. Super silenzioso only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps. 20

RAC Residential +21-15 +43-10 SAME INDOOR UNITS COMPATIBLE WITH MONO/MULTI OUTDOOR (1) (2) (3) (4) Outdoor unit Unit of meas. RAC-18WPB RAC-25WPB RAC-35WPB RAC-50WPB RAC-60WPA RAC-70WPA Nominal cooling capacity (min - max) kw 2.00 (0.90-2.50) 2.50 (0.90-3.10) 3.50 (0.90-4.00) 5.00 (1.90-5.20) 6.10 (0.9-6.5) 7.00 (1.5-8.00) Nominal heating capacity (min - max) kw 2.50 (0.90-3.20) 3.40 (0.90-4.40) 4.20 (0.90-5.00) 6.00 (2.2-7.30) 6.80 (0.9-8.5) 8.00 (1.5-9.2) Nominal cooling power input (min - max) kw 0.55(0.25-1.01) 0.70 (0.25-1.29) 1.090 (0.25-1.46) 1.560 (0.50-2.10) 1.85 (0.155-2.300) 2.17 (0.200-2.820) Nominal heating power input (min - max) kw 0.58 (0.25-0.97) 0.88 (0.25-1.25) 1.100 (0.25-1.70) 1.660 (0.50-2.75) 1.88 (0.120-2.550) 2.2 (0.200-2.970) EER / COP 3.64/4.31 3.57/3.86 3.21/3.82 3.21/3.61 3.30 /3.62 3.23/3.64 SEER / SCOP average climate 7.0/4.30 7.60/4.40 7.20/4.60 7.20/4.41 6.0/4.0 6.8/4.4 Energy class (SEER/SCOP) A++/A+ A++/A+ A++A++ A++/A+ A+/A+ A++/A+ Cooling sound pressure level db(a) 46 48 49 51 50 52 Heating sound pressure level db(a) 47 49 50 51 53 54 Sound power - Indoor/Outdoor db(a) 60 62 63 65 66 67 Dimensions (H x L x D) mm 530x660 x278 530x660 x278 548 750 288 600x792x299 650x850x298 800x850x298 Weight kg 27,5 27,5 34 40 45 55 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch. 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8" Minimum piping length m 3 3 3 3 3 3 Max piping length / max lift m 20 / 10 20 / 10 20 / 10 20 / 10 30 / 20 30 / 20 Max pre-charge length / Amount of additional refrigerant Working range (cooling, heating) m / g/m 20/- 20/- 20/- 20/- 30 / - 30 / - C -10~43-10~43-10~43-10~43-10~43-10~43 C -15~21-15~21-15~21-15~21-15~21-15~21 Refrigerant R410A R410A R410A R410A R410A R410A Indoor unit Unit of meas. RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB RAK-60PPA RAK-70PPA Cooling SPL (SL / L / M / H) db(a) 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 25/28/39/46 30/33/42/48 30/33/42/47 Heating SPL (SL / L / M / H) db(a) 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 27/31/39/46 33/34/42/49 30/33/42/47 Sound power db(a) 51 54 57 60 63 61 Cooling air fl ow rate (SL / L / M / H) m3/h 312/350/400/440 333/370/430/510 353/420/485/680 353/410/540/750 480/540/690/930 510/630/870/1020 Heating air fl ow rate (SL / L / M / H) m3/h 312 / 350 / 420 / 480 333 / 400 / 500/ 570 363 / 480 / 570/ 780 380/500/610/820 480/510/720/1050 510/630/870/1080 Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 295 x 900 x 230 295 x 900 x 230 295x1030x207 333x1150x245 Weight kg 7,5 7,5 10 10 12 15 Piping diameter (Liq / Gas) inch. 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8" Condensate drain diameter (ext) mm 16 16 16 16 16 16 Remote controller (standard, optional) Standard RAR-6N2 RAR-6N2 RAR-6N1 RAR-6N1 RAR-5E2 RAR-5E1 Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB Filter Standard Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-NTW1 Wasabi / SPX-NTW2 Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5 35x270x5 35x280x5 Pre-fi lter Standard WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE Optional Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S /SPX-SPF7 Stainless S /SPX-SPF7 Stainless S/ SPX-SPF3 Stainless S/ SPX-SPF4 (1) without sensor (2) for RAK-18RPB, RAK-25RPB, RAK-35RPB, RAK-50RPB (3) for RAK-60PPA, RAK-70PPA (4) only for RAK-35RPB, RAK-50RPB, RAK-70PPA 21

RAC Mono ECO COMFORT Wall RAK-PEB PAM DC Inverter Split Heat Pump RAK 18~25~35~50PEB Seasonal efficiency the air conditioner features good seasonal efficiencies levels both in cooling and heating mode Super quiet Only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps. 12h Timer Available on the remote controller for convenient daily programming. Leave Home the feature lets you set a minimum hold temperature (10 C) in heating mode for the periods you are away either on holiday or businness. Eco and Powerful functions you may opt whether to operate the air conditioner at very low consumption or at maximum power to reach the desired temperature quickly. Heating at low temperatures guaranteed efficiency in heating mode up to -15 C. 22

RAC Residential +21-15 +43-10 (1) Outdoor unit Unit of meas. RAC-18WEB RAC-25WEB RAC-35WEB RAC-50WEB Nominal cooling capacity (min - max) kw 2.00 (0.90-2.50) 2.50 (0.90-3.10) 3.50 (0.90-4.00) 5.00 (0.90-5.20) Nominal heating capacity (min - max) kw 2.50 (0.90-3.20) 3.40 (0.90-4.40) 4.20 (0.90-5.00) 6.00 (2.2-7.30) Nominal cooling power input (min - max) kw 0.58 (0.25-1.01) 0.70 (0.25-1.29) 1.090 (0.25-1.46) 1.560 (0.50-2.10) Nominal heating power input (min - max) kw 0.62 (0.25-0.97) 0.88 (0.25-1.25) 1.100 (0.25-1.70) 1.660 (0.50-2.75) EER / COP 3.45/4.03 3.57/3.86 3.21/3.82 3.21/3.61 SEER / SCOP average climate 5.80/3.80 5.80/3.80 5.85/3.80 5.88/3.80 Energy class (SEER/SCOP) A+/A A+/A A+/A A+/A Cooling sound pressure level db(a) 46 48 49 51 Heating sound pressure level db(a) 47 49 50 51 Sound power - Indoor/Outdoor db(a) 60 62 63 65 Dimensions (H x L x D) mm 530x660 x278 530x660 x278 530x660 x278 600x792x299 Weight kg 27,5 27,5 27,5 40 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Minimum piping length m 3 3 3 3 Max piping length / max lift m 20 / 10 20 / 10 20 / 10 20 / 10 Max pre-charge length / Amount of additional refrigerant m / g/m 20/- 20/- 20/- 20/- Working range C -10~43-10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21-15~21 Refrigerant R410A R410A R410A R410A Indoor unit Unit of meas. RAK-18PEB RAK-25PEB RAK-35PEB RAK-50PEB Cooling sound pressure level (SL / L / M / H) db(a) 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 28 / 30 / 40 /46 Heating sound pressure level (SL / L / M / H) db(a) 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 25 /30/ 39 /47 Sound power db(a) 51 54 57 60 Cooling air fl ow rate (SL / L / M / H) m3/h 312/350/400/440 333/370/430/510 333/400/485/600 333/450/600/700 Heating air fl ow rate (SL / L / M / H) m3/h 312 / 350 / 420 / 480 333 / 400 / 500/ 570 333 / 520 / 550/ 660 433 / 510 / 650/ 770 Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 Weight kg 7,5 7,5 7,5 8 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter (ext) mm 16 16 16 16 Remote controller (standard, optional) Standard RAR-5F1 RAR-5F1 RAR-5F1 RAR-5F1 Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB Filter Optional Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Standard fi lter dimensions (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5 Pre-fi lter Standard WASHABLE WASHABLE WASHABLE WASHABLE Optional Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 Stainless S/SPX-SPF6 (1) without sensor 23

RAC Mono AKEBONO Floor RAF-RXB PAM DC Inverter Split Heat Pump RAF-25-35-50RXB Elegant design designed to combine comfort and functionality with refined and streamlined aesthetics, it can also be installed suspended above the floor without the white stand. Extended air flow The airflow power can be increased to reach the furthest corners of the room. Nano Titanium the NANO TITANIUM air filter supplied guarantees high quality of the air you breathe in your room. Extremely high seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating mode up to -15 C. Super quiet Only 20dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps. 7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). Leave Home the feature lets you set a minimum hold temperature (10 C-16 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! Info key room temperature reading, power consumption display, alarm signal. Clean function the evaporator is dried to prevent mould formation. 24

RAC Residential +21-15 +43-10 SAME INDOOR UNITS COMPATIBLE WITH MONO/MULTI OUTDOOR (1) Outdoor unit Unit of meas. RAC-25FXB RAC-35FXB RAC-50FXB Nominal cooling capacity (min - max) kw 2.50 (0.90-3.10) 3.5(0.9-4.0) 5.0 (0.9-5.2) Nominal heating capacity (min - max) kw 3.40 (0.90-4.40) 4.5(0.9-5.0) 6.0 (0.9-8.1) Nominal cooling power input (min - max) kw 0.580 (0.155-1.180) 1.020(0.155-1.380) 1.560(0.500-2.100) Nominal heating power input (min - max) kw 0.790(0.115-1.120) 1.220(0.115-1.350) 1.600(0.500-2.700) EER / COP 4.31/4.30 3.43/3.69 3.21/3.75 SEER / SCOP average climate 6.38/4.24 6.39/4.14 5.97/4.15 Energy class (SEER/SCOP) A++/A+ A++/A+ A+/A+ Cooling sound pressure level db(a) 45 46 50 Heating sound pressure level db(a) 47 48 52 Sound power - Indoor/Outdoor db(a) 62 63 65 Dimensions (H x L x D) mm 548 750 288 548 750 288 736 800 350 Weight kg 31,5 31,5 49,5 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Minimum piping length m 3 3 3 Max piping length / max lift m 20 / 10 20 / 10 30 / 10 Max pre-charge length / Amount of additional refrigerant m / g/m 20/- 20/- 30/- Working range C -10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAF-25RXB RAF-35RXB RAF-50RXB Cooling sound pressure level (SL / L / M / H) db(a) 20/26 / 31 /38 20/26/31/39 22/29/36/43 Heating sound pressure level (SL / L / M / H) db(a) 20/26 / 31 /38 20/26/31/39 22/29/36/44 Sound power db(a) 55 56 59 Cooling air fl ow rate (SL / L / M / H) m3/h 270 / 390 / 510 / 630 270/390/510/660 300/450/540/720 Heating air fl ow rate (SL / L / M / H) m3/h 300 / 420 / 540/ 660 300/420/540/690 330/480/570/750 Dimensions (H x L x D) mm 590 x 750 x 215 590 x 750 x 215 590 x 750 x 215 Weight kg 15 15 15 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter (ext) mm 16 16 16 Remote controller (standard, optional) Standard RAR-6N4 RAR-6N4 RAR-6N4 Optional SPX-RCDB SPX-RCDB SPX-RCDB Filter Optional Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Standard fi lter dimensions (H x L x D) mm 48x243x8 48x243x8 48x243x8 Standard Pre-fi lter Stainless Steel Stainless Steel Stainless Steel (1) without sensor 25

RAC Mono PERFORMANCE Floor RAF-RPA PAM DC Inverter Split Heat Pump RAF 25~35~50 RPA NANO TITANIUM the NANO TITANIUM air filter supplied guarantees high quality of the air you breathe in your room. Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiency levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating mode up to -15 C. Quiet only 23dBA noise level at the SUPER LOW speed for guaranteeing peaceful sleeps. Leave Home the feature lets you set a minimum hold temperature (10 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! Info key room temperature reading, power consumption display, alarm signal. Clean function the evaporator is dried to prevent mould formation. 7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). 26

RAC Residential +21-15 +43-10 (1) Outdoor unit Unit of meas. RAC-25FPA RAC-35FPA RAC-50FPA Nominal cooling capacity (min - max) kw 2.50 (0.90-3.10) 3.50 (1.10-4.20) 5.00 (1.90-5.20) Nominal heating capacity (min - max) kw 3.40 (0.90-4.40) 4.20 (1.10-5.20) 6.00 (2.20-7.30) Nominal cooling power input (min - max) kw 0.67 (0.25-1.29) 0.94 (0.25-1.40) 1.51 (0.50-2.10) Nominal heating power input (min - max) kw 0.85 (0.25-1.25) 1.05 (0.25-1.80) 1.66 (0.50-2.70) EER / COP 3.73/4.00 3.72 / 4.00 3.31 / 3.61 SEER / SCOP average climate 5.8/4.3 6.0/4.3 5.9/4.0 Energy class (SEER/SCOP) A+/A+ A+/A+ A+/A+ Cooling sound pressure level db(a) 47 48 51 Heating sound pressure level db(a) 49 49 52 Sound power - Indoor/Outdoor db(a) 61 62 65 Dimensions (H x L x D) mm 548x750x288 548x750x288 600x792x299 Weight kg 31 35 40 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4-3/8 1/4-3/8 1/4-1/2 Minimum piping length m 5 5 5 Max piping length / max lift m 20 / 10 20 / 10 20 / 10 Max pre-charge length / Amount of additional refrigerant m / g /m 20/- 20/- 20/- Working range C -10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAF-25RPA RAF-35RPA RAF-50RPA Cooling sound pressure level (SL / L / M / H) db(a) 23/26/32/40 25/29/35/42 25/30/37/46 Heating sound pressure level (SL / L / M / H) db(a) 23/27/33/40 26/30/35/42 25/30/37/47 Sound power db(a) 54 56 60 Cooling air fl ow rate (SL / L / M / H) m3/h 378/462/540 400/485/600 430/530/650 Heating air fl ow rate (SL / L / M / H) m3/h 408/498/600 440/525/600 470/570/720 Dimensions (H x L x D) mm 600x760x235 600x760x235 600x760x235 Weight kg 14 14 14 Piping diameter (Liq / Gas) inch 1/4-3/8 1/4-3/8 1/4-1/2 Condensate drain diameter (ext) mm 16 16 16 Remote controller (standard, optional) Standard RAR-5E2 RAR-5E2 RAR-5E2 Optional SPX-RCDB SPX-RCDB SPX-RCDB Filter Optional Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Standard fi lter dimensions (H x L x D) mm 48x243x8 48x243x8 48x243x8 Standard Pre-fi lter Stainless steel Stainless steel Stainless steel (1) without sensor 27

Mono Split DUCT Low Static Pressure RAD-RPA PAM DC Inverter Split Heat Pump RAD 25~35~50 RPA Head rise selector depending on whether ductless or linear ducting (up to 4m) installation is opted for, fan head rise may be adjusted via a suitable selector on the electronic board. Optimised refrigerant connections for convenient installation the refrigerant connections are located at the rear of the unit to make installation easier. Ideal for above door installation! Seasonal efficiency the air conditioner features good seasonal efficiencies levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating mode up to -15 C. 7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). (*with IR controller only) Leave Home the feature lets you set a minimum hold temperature (10 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! (*with IR controller only). Info key room temperature reading, power consumption display, alarm signal. (*with IR controller only). Clean function the evaporator is dried to prevent mould formation. Optional infra red or wired remote controller the preferred type of controller may be selected (IR infra red or wired) on purchase. The IR controller includes a higher number of features. + BUILT-IN CONDENSATE DRAIN PUMP This unit is fitted with an internal drain pump to remove the condensate water which accumulates in the drip pan during operation. A float monitors the water level and automatically actuates the pump when required. 28

RAC Residential +21-15 +43-10 (1) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) Outdoor unit Unit of meas. RAC-25NPA RAC-35NPA RAC-50NPA Nominal cooling capacity (min - max) kw 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.6) Nominal heating capacity (min - max) kw 3.5 (0.9-5.5) 4.8 (0.9-6.6) 6.0 (0.9-7.5) Nominal cooling power input (min - max) kw 0.695 (0.155-1.050) 1.240 (0.155-1.280) 2.160 (0.155-2.700) Nominal heating power input (min - max) kw 0.970 (0.115-1.400) 1.700 (0.115-1.920) 2.300 (0.115-2.530) EER / COP 3.60 / 3.61 2.82 / 2.82 2.50 / 2.61 SEER / SCOP average climate 5.1 / 3.8 5.1 / 3.8 4.7 / 3.8 Energy class (SEER/SCOP) A / A A / A B / A Cooling sound pressure level db(a) 46 47 50 Heating sound pressure level db(a) 46 49 52 Sound power - Indoor/Outdoor db(a) 65 65 65 Dimensions (H x L x D) mm 570x750x280 570x750x280 650x850x298 Weight kg 38 38 45 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Minimum piping length m 5 5 5 Max piping length / max lift m 20 / 10 20 / 10 20 / 10 Max pre-charge length / Amount of additional refrigerant m / g/m 20/- 20/- 20/- Working range C -10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAD-25RPA RAD-35RPA RAD-50RPA Cooling sound pressure level (SL / L / M / H) db(a) 29/31/34/36 29/31/34/36 29/32/35/38 Heating sound pressure level (SL / L / M / H) db(a) 27/30/33/37 27/30/33/37 29/32/35/38 Sound power db(a) 57 57 58 Cooling air fl ow rate (SL / L / M / H) m3/h 330/390/450/510 330/390/450/510 330/360/450/510 Heating air fl ow rate (SL / L / M / H) m3/h 360/420/480/600 360/420/480/600 360/420/480/630 Drain pump included yes yes yes Max. height available for drain pump cm 30 30 30 Drain pump pressure lift cm 30 30 30 Dimensions (H x L x D) mm 235x750x400 235x750x400 235x750x400 Weight kg 16 16 16 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter (ext) mm 16 16 16 Standard remote controller (standard, optional) Standard no no no Optional SPX-RCKA o SPX-RCDA SPX-RCKA o SPX-RCDA SPX-RCKA o SPX-RCDA Standard pre-fi lter WASHABLE WASHABLE WASHABLE (1) without sensor (2) with IR controller only 29

Mono Split DUCT Middle Static Pressure RAD-PPA PAM DC Inverter Split Heat Pump RAD 50~60~70 PPA Selettore di prevalenza depending on whether ductless or ducted installation is opted for, fan head rise may be adjusted via a suitable selector on the electronic board. Three static pressure levels (30 / 50 / 80 Pa) may be selected. Ideal for very long ducting! Washable Pre-filter the unit is fitted with a complementary washable prefilter. Seasonal efficiency the air conditioner features good seasonal efficiencies levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating mode up to -15 C. Optional infra red or wired remote controller the preferred type of controller may be selected (IR infra red or wired) on purchase. The IR controller includes a higher number of features. 7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). (*with IR controller only) Leave Home the feature lets you set a minimum hold temperature (10 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! (*with IR controller only). Info key room temperature reading, power consumption display, alarm signal. (*with IR controller only). Clean function the evaporator is dried to prevent mould formation. + BUILT-IN CONDENSATE DRAIN PUMP This unit is fitted with an internal drain pump to remove the condensate water which accumulates in the drip pan during operation. A float monitors the water level and automatically actuates the pump when required. 30

RAC Residential +21-15 +43-10 (1) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) Outdoor unit Unit of meas. RAC-50DPA RAC-60DPA RAC-70DPA Nominal cooling capacity (min - max) kw 5.0 (0.9-6.0) 6.0 (0.9-7.0) 7.1 (0.9-8.0) Nominal heating capacity (min - max) kw 6.0 (0.9-7.0) 7.3 (0.9-8.0) 8.0 (0.9-9.0) Nominal cooling power input (min - max) kw 1.4 (0.200-2.500) 1.87 (0.200-2.500) 2.53 (0.200-2.920) Nominal heating power input (min - max) kw 1.59 (0.200-2.200) 2.13 (0.200-2.600) 2.34 (0.200-3.100) EER / COP 3.57/3.77 3.21/3.43 2.81/3.42 SEER / SCOP average climate 5.4/3.8 5.1/3.8 5.1/3.8 Energy class (SEER/SCOP) A/A A/A A/A Cooling sound pressure level db(a) 47 48 53 Heating sound pressure level db(a) 50 51 55 Sound power - Indoor/Outdoor db(a) 65 65 67 Dimensions (H x L x D) mm 800x850x298 800x850x298 800x850x298 Weight kg 51.5 55 55 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8" Minimum piping length m 5 5 5 Max piping length / max lift m 30 / 20 30 / 20 30 / 20 Max pre-charge length / Amount of additional refrigerant m / g/m 30/- 30/- 30/- Working range C -10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAD-50PPA RAD-60PPA RAD-70PPA Cooling sound pressure level (SL / L / M / H) db(a) 28/30/32/34 28/30/32/34 28/30/32/35 Heating sound pressure level (SL / L / M / H) db(a) 29/31/33/35 29/31/33/35 29/31/33/36 Sound power db(a) 60 60 61 Cooling air fl ow rate (SL / L / M / H) m3/h 618/660/780/900 618/660/780/900 618/660/780/960 Heating air fl ow rate (SL / L / M / H) m3/h 618/660/780/900 618/660/780/900 618/660/780/960 Drain pump included sì sì sì Max. height available for drain pump cm 50 50 50 Drain pump pressure lift cm - - - Max static pressure with activated selector LSP / NSP / HSP Pa (m3/h) 30/50/80 30/50/80 30/50/80 Dimensions (H x L x D) mm 270x900x720 270x900x720 270x900x720 Weight kg 35 35 35 Piping diameter (Liq / Gas) inch 1/4" / 1/2" 1/4" / 1/2" 1/4" / 5/8" Condensate drain diameter (ext) mm 16 16 16 Standard remote controller (standard, optional) Standard no no no Optional SPX-RCDA o SPX-RCKA SPX-RCDA o SPX-RCKA SPX-RCDA o SPX-RCKA Standard pre-fi lter WASHABLE WASHABLE WASHABLE (1) without senosr (2) with IR controller only 31

Mono Split CASSETTE 4 Way RAI-RPA PAM DC Inverter Split Heat Pump RAI 25~35~50 RPA + RAI - ECPP PANEL Compact Design thanks to its compact design, the 60 x 60 cm cassette unit fits into a standard ceiling module, thus reducing installation work to the minimum. Flexibility of use The user may opt for 2, 3 or 4-way operation of automatic swing air outlets. Furthermore, when the unit is installed on high ceilings, air flow power may be increased by means of a switch. 2-WAY 3-WAY 4-WAY Exceptional seasonal efficiency the air conditioner features exceptional seasonal efficiencies levels both in cooling and heating mode. Heating at low temperatures guaranteed performance in heating mode up to -15 C. 7-day timer 6 on/off settings for every day of the week 2 storable programs (summer/winter). Leave Home the feature lets you set a minimum hold temperature (10 C) in heating mode for the periods you are away either on holiday or businness; up to 99 days may be set. Ideal for holiday homes! Info key room temperature reading, power consumption display, alarm signal. Clean function the evaporator is dried to prevent mould formation. + BUILT-IN CONDENSATE DRAIN PUMP This unit is fitted with an internal drain pump to remove the condensate water which accumulates in the drip pan during operation. A float monitors the water level and automatically actuates the pump when required. 32

RAC Residential +21-15 +43-10 (1) Outdoor unit Unit of meas. RAC-25NPA RAC-35NPA RAC-50NPA Nominal cooling capacity (min - max) kw 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.2) Nominal heating capacity (min - max) kw 3.5 (0.9-5.0) 4.8 (0.9-6.6) 6.2 (0.9-7.6) Nominal cooling power input (min - max) kw 0.695 (0.155-1.050) 1.100 (0.155-1.280) 1.990 (0.155-2.200) Nominal heating power input (min - max) kw 0. 940 (0.155-1.400) 1.360 (0.115-1.920) 2.160 (0.155-2.700) EER / COP 3.60 / 3.72 3.18 / 3.53 2.51 / 2.87 SEER / SCOP average climate 5.7 / 3.8 5.8 / 3.8 5.2 / 3.8 Energy class (SEER/SCOP) A+ / A A+ / A A / A Cooling sound pressure level db(a) 46 47 50 Heating sound pressure level db(a) 46 49 52 Sound power - Indoor/Outdoor db(a) 65 65 65 Dimensions (H x L x D) mm 570x750x280 570x750x280 650x850x298 Weight kg 38 38 45 Power supply V/Ph/Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Minimum piping length m 5 5 5 Max piping length / max lift m 20 / 10 20 / 10 20 / 10 Max pre-charge length/amount of additional refrigerant m / g/m 20/- 20/- 20/- Working range C -10~43-10~43-10~43 (cooling, heating) C -15~21-15~21-15~21 Refrigerant R410A R410A R410A Indoor unit Unit of meas. RAI-25RPA RAI-35RPA RAI-50RPA Cooling sound pressure level (SL / L / M / H) db(a) 25/29/32/35 26/29/34/39 29/32/35/43 Heating sound pressure level (SL / L / M / H) db(a) 27/30/33/36 29/32/36/40 30/32/36/43 Sound power db(a) 50 58 58 Cooling air fl ow rate (SL / L / M / H) m3/h 330/360/420/480 390/420/510/570 390/450/510/630 Heating air fl ow rate (SL / L / M / H) m3/h 390/420/480/540 450/480/510/660 450/510/540/690 Drain pump included sì sì sì Max. height available for drain pump cm 11,5 11,5 11,5 Drain pump pressure lift cm 11,5 11,5 11,5 Dimensions (H x L x D) mm 285x580x580 285x580x580 285x580x580 Weight kg 20 20 20 Panel weight kg 4 4 4 Panel dimensions (H x L x D) mm 32x650x650 32x650x650 32x650x650 Code of panel RAI-ECPP RAI-ECPP RAI-ECPP Panel colour (RAL) RAL 9010 RAL 9010 RAL 9010 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter (ext) mm 16 16 16 Standard remote controller (standard, optional) Standard RAR-5E2 RAR-5E2 RAR-5E2 Optional SPX-RCDB SPX-RCDB SPX-RCDB Filter Optional WASABI / SPX-NTW1 WASABI / SPX-NTW1 WASABI / SPX-NTW1 Dimensions standard fi lter (H x L x D) mm 35x270x5 35x270x5 35x270x5 Pre-fi ltro standard LAVABILE LAVABILE LAVABILE (1) without sensor 33

RAC Multi 34

RAC Residential RAC Multi INDOOR UNITS example: RAK 25RPB What type of air conditioner? RAK = wall RAF = floor RAI = 4-way cassette RAD = ductable OUTDOOR UNITS example: What cooling capacity? XW = X,Y kw What type of combination? P = only mono-split Q = only multi-split R = mono and multi-split What family of products? P = Performance RAM 53NP3B What series of products? B = series 2 What series of products? B = series 2 What type of combination? RAC = only mono-split RAM = only multi-split What cooling capacity? XW = X,Y kw What type of application? W = wall F = floor C = 4-way cassette D = ductable N = universal What family of products? P = all Multi How many connections? 2,3,..,6 = 2,3,..,6 environments EFFICIENT & FLEXIBLE PAM DC INVERTER HEAT PUMPS FOR SEVERAL ENVIRONMENTS High seasonal effi ciency Super silent units High fl exibility of installation Summer/Winter Mode Multizone Premium line: Available in several sizes with the possibility of connecting up to 6 indoor units to the same outdoor one. 35

RAC Multizone Premium Outdoor Units PAM DC Inverter Multisplit Heat Pump RAM 33NP2B RAM 40NP2B RAM 53NP2B RAM 53NP3B RAM 68NP3B RAM 70NP4B RAM 90NP5B RAM 110NP6B Outdoor unit Unit of meas. RAM-33NP2B RAM-40NP2B RAM-53NP2B Min / Max number of connectible indoor units 2 2 2 Nominal Cooling Capacity (min - max) kw 3.3 (1.5-3.8) 4.0 (1.5-4.2) 5.3 (1.5-6.6) Nominal Heating Capacity (min - max) kw 4.0 (1.5-4.6) 5.2 (1.5-5.5) 6.8 (1.5-7.2) Nominal Cooling Power Input (min - max) kw 0.80 (0.20-1.05) 1.05 (0.20-1.15) 1.55 (0.20-1.66) Nominal Heating Power Input (min - max) kw 0.92 (0.20-1.50) 1.21 (0.20-1.50) 1.79 (0.20-2.01) EER / COP 4.13/4.35 3.81/4.30 3.42/3.80 SEER / SCOP average climate 6.30/4.30 7.00/4.33 7.15/4.31 Energy Class (SEER/SCOP) A++/A+ A++/A+ A++/A+ Cooling sound pressure level db(a) 48 49 50 Heating sound pressure level db(a) 50 51 51 Sound Power - Indoor/Outdoor db(a) 47/61 47/62 50/62 Dimensions (H x L x D) mm 570x750x280 570x750x280 750x850x298 Weight kg 38 41 53 Power supply V/Ph/Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz Piping diameter (Liq / Gas) inch 1/4 x 2 / 3/8 x 2 1/4 x 2 / 3/8 x 2 ( 1/4 x 2 / 3/8 x 2 ) Minimum piping length m 3 3 3 Max piping length / max lift m 20 / 10 35 / 20 35 / 20 Max pre-charge length/amount of additional refrigerant m / g/m 20/- 35/- 35/- Working range C -10 ~ 43-10 ~ 43-10 ~ 43 (cooling, heating) C -15 ~ 21-15 ~ 21-15 ~ 2 Refrigerant R410A R410A R410A Specifications relating to the following combinations: RAM-33NP2B RAM-40NP2B RAM-53NP2B RAM-53NP3B RAM-68NP3B RAM-70NP4B RAM-90NP5B RAK-15QPB + RAK-18RPB RAK-15QPB + RAK-25RPB RAK-18RPB + RAK-35RPB RAK-18RPB + RAK-35RPB RAK-18RPB + RAK-50RPB RAK-35RPB + RAK-35RPB RAK-35RPB + RAK-50RPB 36

RAC Residential +21-15 +43-10 RAM-53NP3B RAM-68NP3B RAM-70NP4B RAM-90NP5B RAM-110NP6B 2 / 3 2 / 3 2 / 4 2 / 5 2 / 3 (per ciclo refr.) 5.3 (1.5-6.6) 6.8 (2.40-8.00) 7.0 (2.4-8.8) 8.5 (1.52-9.5) 10.6 (1.5-13.2) 6.8 (1.5-7.2) 8.5 (2.4-9.5) 8.5 (2.6-9.5) 11.0 (1.5-11.5) 13.6 (1.5-14.4) 1.55 (0.20-1.68) 2.08 (0.46-2.96) 2.11 (0.46-3.20) 2.23 (0.20-3.85) 3.20 (0.20-3.50) 1.62 (0.20-1.86) 2.28 (0.43-2.60) 2.11 (0.48-3.12) 2.46 (0.20-3.85) 3.60 (0.40-3.72) 3.42/4.20 3.27/3.73 3.32/4.03 3.81/4.47 3.31/3.78 7.15/4.31 6.60/4.20 6.30/4.20 6.50/4.20 6.30/4.20 A++/A+ A++/A+ A++/A+ A++/A+ A++/A+ 50 50 50 53 55 51 53 53 56 56 50/62 50/63 57/63 57/66 50/68 750x850x298 800x850x298 800x850x298 800x950x370 1450x855x308 53 58 58 71 113 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz 220-240V/1ph/ 50/60Hz ( 1/4 x 3 / 3/8 x 3 ) ( 1/4 x 3 / 3/8 x 3 ) ( 1/4 x 4 / 3/8 x 3 + 1/2 x 1) 1/4 x 5 / (3/8 x 3) + (1/2 x 2) ( 1/4 x 3 / 3/8 x 3 ) x 2 3 3 3 3 3 45 / 20 60 / 20 60 / 20 75 / 20 45/20 per ciclo refr. 35/20 30/20 30/20 30/15 35/20-10 ~ 43-10 ~ 43-10 ~ 43-10 ~ 43-10 ~ 43-15 ~ 21-15 ~ 21-15 ~ 21-15 ~ 21-15 ~ 21 R410A R410A R410A R410A R410A COMBINATIONS WALL FLOOR DUCTABLE MEDIUM STATIC PRESSURE CASSETTE OUTDOOR UNIT RAK-QXB RAK-RXB RAK-QPB RAK-RPB RAF-RXB RAD-QPB RAI-QPB 18 25 35 50 15 18 25 35 50 25 35 50 18 25 35 50 25 35 50 RAM-33NP2B x x x x x x x x x RAM-40NP2B x x x x x x x x x x x x x x RAM-53NP2B x x x x x x x x x x x x x x x x x x x RAM-53NP3B x x x x x x x x x x x x x x x x x x x RAM-68NP3B x x x x x x x x x x x x x x x x x x x RAM-70NP4B x x x x x x x x x x x x x x x x x x x RAM-90NP5B x x x x x x x x x x x x x x x x x x x RAM-110NP6B x x x x x x x x x x x x x x x x x x x 37

RAC Multizone Premium Indoor units connectible AKEBONO Wall RAK-RXB / RAK-QXB RAK 18QXB RAK 25/35/50RXB A new line with smooth design enhanced by high quality materials. The same indoor units are connectible either with Multizone Premium outdoor units or with Mono outdoor units. The size 18 of indoor unit is available only for Multi configuration. (1) Indoor unit Unit of meas. RAK-18QXB RAK-25RXB RAK-35RXB RAK-50RXB Nominal cooling capacity (min - max) kw 1.8 (1.0-2.5) 2.50 (0.90-3.10) 3.50 (0.90-4.00) 5.00 (1.90-5.20) Nominal heating capacity (min - max) kw 2.5 (1.1-3.2) 3.20 (0.90-4.20) 4.00 (0.90-4.80) 5.80 (2.2-7.00) Cooling sound pressure (SL / L / M / H) db(a) 20/25/30/36 20/26/32/40 22/29/35/42 25/31/39/47 Heating sound pressure (SL / L / M / H) db(a) 20/26/32/38 20/27/33/40 22/30/35/42 25/31/39/48 Sound power db(a) 49 55 60 60 Cooling air fl ow rate (SL / L / M / H) m3/h 300/330/430/500 300/330/510/560 320/340/430/580 350/400/580/720 Heating air fl ow rate (SL / L / M / H) m3/h 310/360/480/600 290/370/560/610 310/360/480/630 350/420/620/800 Dimensions (H x L x D) mm 295 x 900 x 210 295 x 900 x 210 295 x 900 x 210 VERIFICARE CODICI (LA TABELLA È TRATTA DA LISTINO) 295 x 900 x 210 Weight kg 11 11 11 11 Piping diameter (Liq / Gas) inch 1/4 / 3/8 1/4 / 3/8 1/4 / 3/8 1/4 / 1/2 Condensate drain diameter mm 16 16 16 16 Remote controller Standard RAR-6N1 RAR-6N1 RAR-6N1 RAR-6N1 (standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB Standard fi lter Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Wasabi / SPX-CFH22 Dimensions standard fi lter (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5 Standard Pre-fi lter Stainless steel Stainless steel Stainless steel Stainless steel (1) with presence sensor 38

RAC Residential PERFORMANCE Wall RAK-RPB / RAK-QPB RAK 15QPB RAK 18/25/35/50RPB A line with traditional design suitble for classic environment. The same indoor units are connectible either with Multizone Premium outdoor units or with Mono outdoor units. The size 15 of indoor unit is available only for Multi configuration. (1) (2) Indoor unit Unit of meas. RAK-15QPB RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB Nominal cooling capacity (min - max) kw 1.50 (0.90-2.00) 2.00 (0.90-2.50) 2.50 (0.90-3.10) 3.50 (0.90-4.00) 5.00 (1.90-5.20) Nominal heating capacity (min - max) kw 2.00 (1.00-2.50) 2.50 (0.90-3.20) 3.40 (0.90-4.40) 4.20 (0.90-5.00) 6.00 (2.2-7.30) Cooling sound pressure (SL / L / M / H) db(a) 20/24/30/34 21/24 / 33 / 37 22/24 / 33 /40 25/26/36/43 25/28/39/46 Heating sound pressure (SL / L / M / H) db(a) 20/24/32/35 19/22 / 33 / 38 20/23 / 34 / 41 26/27/36/44 27/31/39/46 Sound power db(a) 47 51 54 57 60 Cooling air fl ow rate (SL / L / M / H) Heating air fl ow rate (SL / L / M / H) m3/h m3/h 312 / 350 / 400 / 420 312 / 350 / 420 / 480 312 / 350 / 400 / 440 312 / 350 / 420 / 480 333 / 370 / 430 / 510 333 / 400 / 500/ 570 353 /420 / 485 / 680 363 / 480 / 570/ 780 353/410/540/750 380/500/610/820 Dimensions (H x L x D) mm 280 x 780 x 218 280 x 780 x 218 280 x 780 x 218 295 x 900 x 230 295 x 900 x 230 Weight kg 7,5 7,5 7,5 10 10 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter mm 16 16 16 16 16 Remote controller Standard RAR-6N2 RAR-6N2 RAR-6N2 RAR-6N1 RAR-6N1 (standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB SPX-RCDB Standard fi lter Wasabi / SPX- CFH22 Wasabi / SPX- CFH22 Wasabi / SPX- CFH22 Wasabi / SPX- CFH22 Wasabi / SPX- CFH22 Dimensions standard fi lter (H x L x D) mm 48x243x5 48x243x5 48x243x5 48x243x5 48x243x5 Standard Pre-fi lter WASHABLE WASHABLE WASHABLE WASHABLE WASHABLE Optional Pre-fi lter Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF6 Stainl. S./SPX-SPF7 Stainl. S./SPX-SPF7 (1) without sensor (2) only for RAK-35RPB, RAK-50RPB 39

RAC Multizone Premium Indoor units connectible AKEBONO Wall RAF-RXB RAF 25/35/50RXB A new line with modern design suitable for casual environment. The same indoor units are connectible either with Multizone Premium outdoor units or with Mono outdoor units. The indoor unit could be either installed leaning on the floor or suspended above the floor without the white stand. (1) Indoor unit Unit of meas. RAF-25RXB RAF-35RXB RAF-50RXB Nominal cooling capacity (min - max) kw 2.50 (0.90-3.10) 3.5(0.9-4.0) 5.0 (0.9-5.2) Nominal heating capacity (min - max) kw 3.40 (0.90-4.40) 4.5(0.9-5.0) 6.0 (0.9-8.1) Cooling sound pressure (SL / L / M / H) db(a) 20/26 / 31 /38 20/26/31/39 22/29/36/43 Heating sound pressure (SL / L / M / H) db(a) 20/26 / 31 /38 20/26/31/39 22/29/36/44 Sound power db(a) 55 56 59 Cooling air fl ow rate (SL / L / M / H) m3/h 270 / 390 / 510 / 630 270/390/510/660 300/450/540/720 Heating air fl ow rate (SL / L / M / H) m3/h 300 / 420 / 540/ 660 300/420/540/690 330/480/570/750 Dimensions (H x L x D) mm 590 x 750 x 215 590 x 750 x 215 590 x 750 x 215 Weight kg 15 15 15 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter mm 16 16 16 Remote controller Standard RAR-6N4 RAR-6N4 RAR-6N4 (standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB Standard fi lter Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Nano Titanium/SPX-CFH15 Dimensions standard fi lter (H x L x D) mm 48x243x8 48x243x8 48x243x8 Standard Pre-fi lter Stainless steel Stainless steel Stainless steel (1) without sensor 40

RAC Residential DUCT Middle Static Pressure RAD-QPB RAD 18/25/35/50QPB Available only for Multi combination. This new compact unit can be mount either in a duct or in a ductless configuration. Depending on whether ductless or linear ducting installation is opted for, fan static pressure may be adjusted via a suitable selector on the electronic board (max. 69Pa). For further details on static pressure consult Hitachi technical documentation. IR remote controller or wired remote control shall be separately purchased. (1) (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) Indoor unit Unit of meas. RAD-18QPB RAD-25QPB RAD-35QPB RAD-50QPB Nominal cooling capacity (min - max) kw 1.8 (0.9~2.5) 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.6) Nominal heating capacity (min - max) kw 2.5 (0.9~3.2) 3.5 (0.9-5.5) 4.8 (0.9-6.6) 6.0 (0.9-7.5) Cooling sound pressure (SL / L / M / H) db(a) 30/33/37/41 30/33/37/41 30/33/37/41 31/35/39/43 Heating sound pressure (SL / L / M / H) db(a) 30/34/38/42 30/34/38/42 30/34/38/42 32/35/39/43 Sound power db(a) 57 57 57 58 Cooling air fl ow rate (SL / L / M / H) m3/h 400/480/560/600 400/480/560/600 400/480/570/660 400/480/570/660 Heating air fl ow rate (SL / L / M / H) m3/h 450/520/590/650 450/520/590/650 440/510/600/720 440/510/600/720 Included condensate drain pump yes yes yes yes Max height available for drain pump cm 30 30 30 30 Drain pump pressure lift cm 15 15 15 15 Static pressure - Air fl ow rate with switch at High position (Cooling / Heating [L / M / H]) Pa (m3/h) C [42(242)/49(274)/51(291)] H [46(266)/52(293)/57(314)] C [42(242)/49(274)/51(291)] H [46(266)/52(293)/57(314)] C [44(243)/50(279)/58(323)] H [51(259)/58(289)/69(340)] C [44(243)/50(279)/58(323)] H [51(259)/58(289)/69(340)] Dimensions (H x L x D) mm 235x750x400 235x750x400 235x750x400 235x750x400 Weight kg 16 16 16 16 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter mm 16 16 16 16 Standard no no no no Remote controller (standard, optional) Optional SPX-RCDA o SPX-RCKA1 SPX-RCDA o SPX-RCKA1 SPX-RCDA o SPX-RCKA1 SPX-RCDA o SPX-RCKA1 Standard Pre-fi lter WASHABLE WASHABLE WASHABLE WASHABLE (1) without sensor (2) with IR controller only 41

RAC Multizone Premium Indoor units connectible CASSETTE 4 Way RAI-QPB RAI 25/35/50QPB/50QPB Available only for Multi combination. Perfect for both modern and classic environments, thanks to pure white aesthetic panel and to minimal design. (1) Indoor unit Unit of meas. RAI-25QPB RAI-35QPB RAI-50QPB Nominal cooling capacity (min - max) kw 2.5 (0.9-3.0) 3.5 (0.9-4.0) 5.0 (0.9-5.2) Nominal heating capacity (min - max) kw 3.5 (0.9-5.0) 4.8 (0.9-6.6) 6.2 (0.9-7.6) Cooling sound pressure (SL / L / M / H) db(a) 28/31/34/37 30/34/38/42 32/36/40/44 Heating sound pressure (SL / L / M / H) db(a) 29/32/35/38 30/35/39/43 32/36/40/44 Sound power db(a) 50 58 58 Cooling air fl ow rate (SL / L / M / H) m3/h 330/360/420/510 390/420/510/650 390/450/510/720 Heating air fl ow rate (SL / L / M / H) m3/h 390/420/480/550 450/480/510/660 450/510/540/720 Included condensate drain pump yes yes yes Max height available for drain pump cm 30,4 30,4 30,4 Drain pump pressure lift cm 11,5 11,5 11,5 Dimensions (H x L x D) mm 285x580x580 285x580x580 285x580x580 Weight kg 20 20 20 Panel weight kg 4 4 4 Panel dimensions (H x L x D) mm 32x650x650 32x650x650 32x650x650 Panel code RAI-ECPP RAI-ECPP RAI-ECPP Panel colour (RAL) RAL 9010 RAL 9010 RAL 9010 Piping diameter (Liq / Gas) inch 1/4" / 3/8" 1/4" / 3/8" 1/4" / 1/2" Condensate drain diameter mm 16 16 16 Remote controller Standard RAR-6N2 RAR-6N2 RAR-6N2 (standard, optional) Optional SPX-RCDB SPX-RCDB SPX-RCDB Standard fi lter WASABI / SPX-NTW1 WASABI / SPX-NTW1 WASABI / SPX-NTW1 Standard fi lter dimensions (H x L x D) mm 35x270x5 35x270x5 35x270x5 Pre-fi ltro standard WASHABLE WASHABLE WASHABLE (1) without sensor 42

RAC Residential 43

RAC Multizone Premium MULTI COMBINATIONS POSSIBLE COMBINATIONS RAM-33NP2B RAM-40NP2B RAM-53NP3B RAM-68NP3B RAM-70NP4B RAM-70NP4B ONE UNIT TWO UNITS THREE UNITS - - - - - 1,5+1,5+1,5+1,5 - - - - - 1,5+1,5+1,5+1,8 - - - - - 1,5+1,5+1,5+2,5 - - - - - 1,5+1,5+1,5+3,5 - - - - - 1,5+1,5+1,5+5,0 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5 1,5+1,5+1,8+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,8 1,5+1,5+1,8+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+2,5 1,5+1,5+1,8+3,5 1,8+1,8 1,5+3,5 1,5+3,5 1,5+3,5 1,5+3,5 1,5+1,5+1,8+5,0 1,8+2,5 1,8+1,8 1,5+5,0 1,5+5,0 1,5+5,0 1,5+1,5+2,5+2,5 2,5+2,5 1,8+2,5 1,8+1,8 1,8+1,8 1,8+1,8 1,5+1,5+2,5+3,5-1,8+3,5 1,8+2,5 1,8+2,5 1,8+2,5 1,5+1,5+2,5+5,0-2,5+2,5 1,8+3,5 1,8+3,5 1,8+3,5 1,5+1,5+3,5+3,5-2,5+3,5 1,8+5,0 1,8+5,0 1,8+5,0 1,5+1,5+3,5+5,0 - - 2,5+2,5 2,5+2,5 2,5+2,5 1,5+1,8+1,8+1,8 - - 2,5+3,5 2,5+3,5 2,5+3,5 1,5+1,8+1,8+2,5 - - 3,5+3,5 2,5+5,0 2,5+5,0 1,5+1,8+1,8+3,5 - - 2,5+5,0 3,5+3,5 3,5+3,5 1,5+1,8+1,8+5,0 - - 3,5+5,0 3,5+5,0 3,5+5,0 1,5+1,8+2,5+2,5 - - - 5,0+5,0 5,0+5,0 1,5+1,8+2,5+3,5 - - 1,5+1,5+1,5 1,5+1,5+1,5 1,5+1,5+1,5 1,5+1,8+2,5+5,0 - - 1,5+1,5+1,8 1,5+1,5+1,8 1,5+1,5+1,8 1,5+1,8+3,5+3,5 - - 1,5+1,5+2,5 1,5+1,5+2,5 1,5+1,5+2,5 1,5+2,5+2,5+2,5 - - 1,5+1,5+3,5 1,5+1,5+3,5 1,5+1,5+3,5 1,5+2,5+2,5+3,5 - - 1,5+1,5+5,0 1,5+1,5+5,0 1,5+1,5+5,0 1,5+2,5+3,5+3,5 - - 1,5+1,8+1,8 1,5+1,8+1,8 1,5+1,8+1,8 1,8+1,8+1,8+1,8 - - 1,5+1,8+2,5 1,5+1,8+2,5 1,5+1,8+2,5 1,8+1,8+1,8+2,5 - - 1,5+1,8+3,5 1,5+1,8+3,5 1,5+1,8+3,5 1,8+1,8+1,8+3,5 - - 1,5+1,8+5,0 1,5+1,8+5,0 1,5+1,8+5,0 1,8+1,8+1,8+5,0 - - 1,5+2,5+2,5 1,5+2,5+2,5 1,5+2,5+2,5 1,8+1,8+2,5+2,5 - - 1,5+2,5+3,5 1,5+2,5+3,5 1,5+2,5+3,5 1,8+1,8+2,5+3,5 - - 1,5+3,5+3,5 1,5+2,5+5,0 1,5+2,5+5,0 1,8+1,8+3,5+3,5 - - 1,8+1,8+1,8 1,5+3,5+3,5 1,5+3,5+3,5 1,8+2,5+2,5+2,5 - - 1,8+1,8+2,5 1,5+3,5+5,0 1,5+3,5+5,0 1,8+2,5+2,5+3,5 - - 1,8+1,8+3,5 1,8+1,8+1,8 1,8+1,8+1,8 2,5+2,5+2,5+2,5 - - 1,8+1,8+5,0 1,8+1,8+2,5 1,8+1,8+2,5 2,5+2,5+2,5+3,5 - - 1,8+2,5+2,5 1,8+1,8+3,5 1,8+1,8+3,5 - - - 1,8+2,5+3,5 1,8+1,8+5,0 1,8+1,8+5,0 - - - 1,8+3,5+3,5 1,8+2,5+2,5 1,8+2,5+2,5 - - - 2,5+2,5+2,5 1,8+2,5+3,5 1,8+2,5+3,5 - - - 2,5+2,5+3,5 1,8+2,5+5,0 1,8+2,5+5,0 - - - - 1,8+3,5+3,5 1,8+3,5+3,5 - - - - 1,8+3,5+5,0 1,8+3,5+5,0 - - - - 2,5+2,5+2,5 2,5+2,5+2,5 - - - - 2,5+2,5+3,5 2,5+2,5+3,5 - - - - 2,5+2,5+5,0 2,5+2,5+5,0 - - - - 2,5+3,5+3,5 2,5+3,5+3,5 - - - - 2,5+3,5+5,0 2,5+3,5+5,0 - - - - 3,5+3,5+3,5 3,5+3,5+3,5 - FOUR UNITS 44

RAC Residential POSSIBLE COMBINATIONS RAM-90NP5B RAM-90NP5B RAM-90NP5B RAM-90NP5B ONE UNIT TWO UNITS THREE UNITS - 1,5+1,5+1,5+1,5 2,5+2,5+2,5+5,0 1,5+1,8+2,5+3,5+5,0-1,5+1,5+1,5+1,8 2,5+2,5+3,5+3,5 1,5+1,8+3,5+3,5+3,5-1,5+1,5+1,5+2,5 2,5+2,5+3,5+5,0 1,5+1,8+3,5+3,5+5,0 FOUR UNITS FOUR UNITS - 1,5+1,5+1,5+3,5 2,5+2,5+5,0+5,0 1,8+1,8+1,8+1,8+1,8-1,5+1,5+1,5+5,0 2,5+3,5+3,5+3,5 1,8+1,8+1,8+1,8+2,5 1,5+1,5 1,5+1,5+1,8+1,8 2,5+3,5+3,5+5,0 1,8+1,8+1,8+1,8+3,5 1,5+1,8 1,5+1,5+1,8+2,5 3,5+3,5+3,5+3,5 1,8+1,8+1,8+1,8+5,0 1,5+2,5 1,5+1,5+1,8+3,5 3,5+3,5+3,5+5,0 1,8+1,8+1,8+2,5+2,5 1,5+3,5 1,5+1,5+1,8+5,0 1,5+1,5+1,5+1,5+1,5 1,8+1,8+1,8+2,5+3,5 1,5+5,0 1,5+1,5+2,5+2,5 1,5+1,5+1,5+1,5+1,8 1,8+1,8+1,8+2,5+5,0 1,8+1,8 1,5+1,5+2,5+3,5 1,5+1,5+1,5+1,5+2,5 1,8+1,8+1,8+3,5+3,5 1,8+2,5 1,5+1,5+2,5+5,0 1,5+1,5+1,5+1,5+3,5 1,8+1,8+1,8+3,5+5,0 1,8+3,5 1,5+1,5+3,5+3,5 1,5+1,5+1,5+1,5+5,0 1,8+1,8+1,8+5,0+5,0 1,8+5,0 1,5+1,5+3,5+5,0 1,5+1,5+1,5+1,8+1,8 1,8+1,8+2,5+2,5+2,5 2,5+2,5 1,5+1,5+5,0+5,0 1,5+1,5+1,5+1,8+2,5 1,8+1,8+2,5+2,5+3,5 2,5+3,5 1,5+1,8+1,8+1,8 1,5+1,5+1,5+1,8+3,5 1,8+1,8+2,5+2,5+5,0 2,5+5,0 1,5+1,8+1,8+2,5 1,5+1,5+1,5+1,8+5,0 1,8+1,8+2,5+3,5+3,5 3,5+3,5 1,5+1,8+1,8+3,5 1,5+1,5+1,5+2,5+2,5 1,8+1,8+2,5+3,5+5,0 3,5+5,0 1,5+1,8+1,8+5,0 1,5+1,5+1,5+2,5+3,5 1,8+1,8+3,5+3,5+3,5 5,0+5,0 1,5+1,8+2,5+2,5 1,5+1,5+1,5+2,5+5,0 1,8+2,5+2,5+2,5+2,5 1,5+1,5+1,5 1,5+1,8+2,5+3,5 1,5+1,5+1,5+3,5+3,5 1,8+2,5+2,5+2,5+3,5 1,5+1,5+1,8 1,5+1,8+2,5+5,0 1,5+1,5+1,5+3,5+5,0 1,8+2,5+2,5+2,5+5,0 1,5+1,5+2,5 1,5+1,8+3,5+3,5 1,5+1,5+1,5+5,0+5,0 1,8+2,5+2,5+3,5+3,5 1,5+1,5+3,5 1,5+1,8+3,5+5,0 1,5+1,5+1,8+1,8+1,8 1,8+2,5+2,5+3,5+5,0 1,5+1,5+5,0 1,5+1,8+5,0+5,0 1,5+1,5+1,8+1,8+2,5 1,8+2,5+3,5+3,5+3,5 1,5+1,8+1,8 1,5+2,5+2,5+2,5 1,5+1,5+1,8+1,8+3,5 2,5+2,5+2,5+2,5+2,5 1,5+1,8+2,5 1,5+2,5+2,5+3,5 1,5+1,5+1,8+1,8+5,0 2,5+2,5+2,5+2,5+3,5 1,5+1,8+3,5 1,5+2,5+2,5+5,0 1,5+1,5+1,8+2,5+2,5 2,5+2,5+2,5+2,5+5,0 1,5+1,8+5,0 1,5+2,5+3,5+3,5 1,5+1,5+1,8+2,5+3,5 2,5+2,5+2,5+3,5+3,5 1,5+2,5+2,5 1,5+2,5+3,5+5,0 1,5+1,5+1,8+2,5+5,0 2,5+2,5+3,5+3,5+3,5 1,5+2,5+3,5 1,5+2,5+5,0+5,0 1,5+1,5+1,8+3,5+3,5-1,5+2,5+5,0 1,5+3,5+3,5+3,5 1,5+1,5+1,8+3,5+5,0-1,5+3,5+3,5 1,5+3,5+3,5+5,0 1,5+1,5+1,8+5,0+5,0-1,5+3,5+5,0 1,5+3,5+5,0+5,0 1,5+1,5+2,5+2,5+2,5-1,5+5,0+5,0 1,8+1,8+1,8+1,8 1,5+1,5+2,5+2,5+3,5-1,8+1,8+1,8 1,8+1,8+1,8+2,5 1,5+1,5+2,5+2,5+5,0-1,8+1,8+2,5 1,8+1,8+1,8+3,5 1,5+1,5+2,5+3,5+3,5-1,8+1,8+3,5 1,8+1,8+1,8+5,0 1,5+1,5+2,5+3,5+5,0-1,8+1,8+5,0 1,8+1,8+2,5+2,5 1,5+1,5+2,5+5,0+5,0-1,8+2,5+2,5 1,8+1,8+2,5+3,5 1,5+1,5+3,5+3,5+3,5-1,8+2,5+3,5 1,8+1,8+2,5+5,0 1,5+1,5+3,5+3,5+5,0-1,8+2,5+5,0 1,8+1,8+3,5+3,5 1,5+1,8+1,8+1,8+1,8-1,8+3,5+3,5 1,8+1,8+3,5+5,0 1,5+1,8+1,8+1,8+2,5-1,8+3,5+5,0 1,8+1,8+5,0+5,0 1,5+1,8+1,8+1,8+3,5-1,8+5,0+5,0 1,8+2,5+2,5+2,5 1,5+1,8+1,8+1,8+5,0-2,5+2,5+2,5 1,8+2,5+2,5+3,5 1,5+1,8+1,8+2,5+2,5-2,5+2,5+3,5 1,8+2,5+2,5+5,0 1,5+1,8+1,8+2,5+3,5-2,5+2,5+5,0 1,8+2,5+3,5+3,5 1,5+1,8+1,8+2,5+5,0-2,5+3,5+3,5 1,8+2,5+3,5+5,0 1,5+1,8+1,8+3,5+3,5-2,5+3,5+5,0 1,8+2,5+5,0+5,0 1,5+1,8+1,8+3,5+5,0-2,5+5,0+5,0 1,8+3,5+3,5+3,5 1,5+1,8+1,8+5,0+5,0-3,5+3,5+3,5 1,8+3,5+3,5+5,0 1,5+1,8+2,5+2,5+2,5-3,5+3,5+5,0 1,8+3,5+5,0+5,0 1,5+1,8+2,5+2,5+3,5-3,5+5,0+5,0 2,5+2,5+2,5+2,5 1,5+1,8+2,5+2,5+5,0-5,0+5,0+5,0 2,5+2,5+2,5+3,5 1,5+1,8+2,5+3,5+3,5 - FIVE UNITS FIVE UNITS 45

RAC Multizone Premium POSSIBLE COMBINATIONS RAM-110NP6B RAM-110NP6B RAM-110NP6B RAM-110NP6B RAM-110NP6B FOUR UNITS THREE UNITS (*) TWO UNITS (*) ONE UNIT (*) - 1,5+1,8+1,8+5,0 1,5+1,5+1,5+2,5+2,5 1,5+3,5+1,5+1,5+1,8 1,8+5,0+1,8+2,5+3,5-1,5+1,8+2,5+2,5 1,5+1,5+1,5+2,5+3,5 1,5+3,5+1,5+1,5+2,5 3,5+3,5+1,8+1,8+3,5-1,5+1,8+2,5+3,5 1,5+1,5+1,5+3,5+3,5 1,5+3,5+1,5+1,5+3,5 2,5+2,5+1,8+2,5+2,5-1,5+1,8+2,5+5,0 1,5+1,5+1,8+1,8+1,8 1,5+3,5+1,5+1,5+5,0 2,5+3,5+1,8+2,5+2,5-1,5+1,8+3,5+3,5 1,5+1,5+1,8+1,8+2,5 1,5+3,5+1,5+1,8+1,8 1,8+5,0+2,5+2,5+2,5-1,5+1,8+3,5+5,0 1,5+1,5+1,8+1,8+3,5 1,5+3,5+1,5+1,8+2,5 3,5+3,5+1,8+2,5+2,5-1,5+2,5+1,5+2,5 1,5+1,5+1,8+1,8+5,0 1,5+3,5+1,5+1,8+3,5 2,5+5,0+1,8+2,5+3,5-1,5+2,5+2,5+2,5 1,5+1,5+1,8+2,5+2,5 1,5+3,5+1,5+1,8+5,0 3,5+3,5+1,8+2,5+3,5-1,5+2,5+2,5+3,5 1,5+1,5+1,8+2,5+3,5 1,5+3,5+1,5+2,5+2,5 3,5+3,5+1,8+3,5+3,5-1,5+2,5+2,5+5,0 1,5+1,5+1,8+3,5+3,5 1,5+3,5+1,5+2,5+3,5 2,5+2,5+2,5+2,5+2,5-1,5+2,5+3,5+3,5 1,5+1,5+2,5+2,5+2,5 1,5+3,5+1,5+3,5+3,5 2,5+3,5+2,5+2,5+2,5-1,5+2,5+3,5+5,0 1,5+1,5+2,5+2,5+3,5 1,5+3,5+1,8+1,8+1,8 2,5+5,0+2,5+2,5+2,5-1,5+3,5+1,5+3,5 1,5+1,8+1,5+1,5+1,5 1,5+3,5+1,8+1,8+2,5 3,5+3,5+2,5+2,5+2,5-1,5+3,5+3,5+3,5 1,5+1,8+1,5+1,5+1,8 1,5+3,5+1,8+1,8+3,5 2,5+5,0+2,5+2,5+3,5-1,5+3,5+3,5+5,0 1,5+1,8+1,5+1,5+2,5 1,5+3,5+1,8+1,8+5,0 3,5+3,5+2,5+2,5+3,5-1,5+5,0+1,5+5,0 1,5+1,8+1,5+1,5+3,5 1,5+3,5+1,8+2,5+2,5 3,5+5,0+2,5+2,5+3,5-1,8+1,8+1,8+1,8 1,5+1,8+1,5+1,5+5,0 1,5+3,5+1,8+2,5+3,5 1,5+1,5+1,5+1,5+1,5+1,5-1,8+1,8+1,8+2,5 1,5+1,8+1,5+1,8+1,8 1,5+3,5+1,8+3,5+3,5 1,5+1,5+1,5+1,5+1,5+1,8-1,8+2,5+1,8+2,5 1,5+1,8+1,5+1,8+2,5 1,5+3,5+2,5+2,5+2,5 1,5+1,5+1,5+1,5+1,5+2,5-1,8+1,8+1,8+3,5 1,5+1,8+1,5+1,8+3,5 1,5+3,5+2,5+2,5+3,5 1,5+1,5+1,5+1,5+1,5+3,5-1,8+2,5+1,8+3,5 1,5+1,8+1,5+1,8+5,0 1,5+5,0+1,5+1,5+1,5 1,5+1,5+1,5+1,5+1,5+5,0-1,8+1,8+1,8+5,0 1,5+1,8+1,5+2,5+2,5 1,5+5,0+1,5+1,5+1,8 1,5+1,5+1,5+1,5+1,8+1,8 FOUR UNITS - 1,8+2,5+1,8+5,0 1,5+1,8+1,5+2,5+3,5 1,5+5,0+1,5+1,5+2,5 1,5+1,5+1,5+1,5+1,8+2,5-1,8+3,5+1,8+3,5 1,5+1,8+1,5+3,5+3,5 1,5+5,0+1,5+1,5+3,5 1,5+1,5+1,5+1,5+1,8+3,5-1,8+3,5+1,8+5,0 1,5+1,8+1,8+1,8+1,8 1,5+5,0+1,5+1,5+5,0 1,5+1,5+1,5+1,5+1,8+5,0-1,8+5,0+1,8+5,0 1,5+1,8+1,8+1,8+2,5 1,5+5,0+1,5+1,8+1,8 1,5+1,5+1,5+1,5+2,5+2,5 FIVE UNITS - 1,8+2,5+2,5+2,5 1,5+1,8+1,8+1,8+3,5 1,5+5,0+1,5+1,8+2,5 1,5+1,5+1,5+1,5+2,5+3,5-1,8+5,0+2,5+2,5 1,5+1,8+1,8+1,8+5,0 1,5+5,0+1,5+1,8+3,5 1,5+1,5+1,5+1,5+3,5+3,5-1,8+3,5+2,5+2,5 1,5+1,8+1,8+2,5+2,5 1,5+5,0+1,5+1,8+5,0 1,5+1,5+1,5+1,8+1,8+1,8-1,8+3,5+2,5+3,5 1,5+1,8+1,8+2,5+3,5 1,5+5,0+1,5+2,5+2,5 1,5+1,5+1,5+1,8+1,8+2,5-1,8+5,0+2,5+3,5 1,5+1,8+1,8+3,5+3,5 1,5+5,0+1,5+2,5+3,5 1,5+1,5+1,5+1,8+1,8+3,5-1,8+5,0+2,5+5,0 1,5+1,8+2,5+2,5+2,5 1,5+5,0+1,5+3,5+3,5 1,5+1,5+1,5+1,8+1,8+5,0-1,8+3,5+3,5+3,5 1,5+1,8+2,5+2,5+3,5 1,5+5,0+1,8+1,8+1,8 1,5+1,5+1,5+1,8+2,5+2,5-1,8+5,0+3,5+3,5 1,5+2,5+1,5+1,5+1,5 1,5+5,0+1,8+1,8+2,5 1,5+1,5+1,5+1,8+2,5+3,5-1,8+5,0+3,5+5,0 1,5+2,5+1,5+1,5+1,8 1,5+5,0+1,8+1,8+3,5 1,5+1,5+1,5+1,8+3,5+3,5-2,5+2,5+2,5+2,5 1,5+2,5+1,5+1,5+2,5 1,5+5,0+1,8+1,8+5,0 1,5+1,5+1,5+2,5+2,5+2,5-2,5+2,5+2,5+3,5 1,5+2,5+1,5+1,5+3,5 1,5+5,0+1,8+2,5+2,5 1,5+1,5+1,5+2,5+2,5+3,5-2,5+2,5+2,5+5,0 1,5+2,5+1,5+1,5+5,0 1,5+5,0+1,8+2,5+3,5 1,5+1,5+1,8+1,5+1,5+1,5-2,5+3,5+2,5+3,5 1,5+2,5+1,5+1,8+1,8 1,5+5,0+1,8+3,5+3,5 1,5+1,5+1,8+1,5+1,5+1,8-2,5+5,0+2,5+3,5 1,5+2,5+1,5+1,8+2,5 1,5+5,0+2,5+2,5+2,5 1,5+1,5+1,8+1,5+1,5+2,5 1,5+1,5+1,5+1,5 2,5+5,0+2,5+5,0 1,5+2,5+1,5+1,8+3,5 1,5+5,0+2,5+2,5+3,5 1,5+1,5+1,8+1,5+1,5+3,5 1,5+1,5+1,5+1,8 2,5+3,5+3,5+3,5 1,5+2,5+1,5+1,8+5,0 1,8+1,8+1,8+1,8+1,8 1,5+1,5+1,8+1,5+1,5+5,0 1,5+1,5+1,5+2,5 2,5+5,0+3,5+3,5 1,5+2,5+1,5+2,5+2,5 1,8+1,8+1,8+1,8+2,5 1,5+1,5+1,8+1,5+1,8+1,8 1,5+1,5+1,5+3,5 3,5+3,5+3,5+3,5 1,5+2,5+1,5+2,5+3,5 1,8+3,5+1,8+1,8+1,8 1,5+1,5+1,8+1,5+1,8+2,5 1,5+1,5+1,5+5,0 3,5+3,5+3,5+5,0 1,5+2,5+1,5+3,5+3,5 1,8+5,0+1,8+1,8+1,8 1,5+1,5+1,8+1,5+1,8+3,5 1,5+1,5+1,8+2,5 3,5+5,0+3,5+5,0 1,5+2,5+1,8+1,8+1,8 1,8+2,5+1,8+1,8+2,5 1,5+1,5+1,8+1,5+1,8+5,0 1,5+1,5+1,8+3,5 1,5+1,5+1,5+1,5+1,5 1,5+2,5+1,8+1,8+2,5 1,8+3,5+1,8+1,8+2,5 1,5+1,5+1,8+1,5+2,5+2,5 1,5+1,5+1,8+5,0 1,5+1,5+1,5+1,5+1,8 1,5+2,5+1,8+1,8+3,5 1,8+5,0+1,8+1,8+2,5 1,5+1,5+1,8+1,5+2,5+3,5 1,5+1,5+2,5+3,5 1,5+1,5+1,5+1,5+2,5 1,5+2,5+1,8+1,8+5,0 1,8+3,5+1,8+1,8+3,5 1,5+1,5+1,8+1,5+3,5+3,5 FIVE UNITS 1,5+1,5+2,5+5,0 1,5+1,5+1,5+1,5+3,5 1,5+2,5+1,8+2,5+2,5 1,8+5,0+1,8+1,8+3,5 1,5+1,5+1,8+1,8+1,8+1,8 1,5+1,5+3,5+5,0 1,5+1,5+1,5+1,5+5,0 1,5+2,5+1,8+2,5+3,5 1,8+5,0+1,8+1,8+5,0 1,5+1,5+1,8+1,8+1,8+2,5 1,5+1,8+1,5+1,8 1,5+1,5+1,5+1,8+1,8 1,5+2,5+1,8+3,5+3,5 2,5+2,5+1,8+1,8+2,5 1,5+1,5+1,8+1,8+1,8+3,5 1,5+1,8+1,8+1,8 1,5+1,5+1,5+1,8+2,5 1,5+2,5+2,5+2,5+2,5 2,5+3,5+1,8+1,8+2,5 1,5+1,5+1,8+1,8+1,8+5,0 1,5+1,8+1,8+2,5 1,5+1,5+1,5+1,8+3,5 1,5+2,5+2,5+2,5+3,5 1,8+5,0+1,8+2,5+2,5 1,5+1,5+1,8+1,8+2,5+2,5 1,5+1,8+1,8+3,5 1,5+1,5+1,5+1,8+5,0 1,5+3,5+1,5+1,5+1,5 3,5+3,5+1,8+1,8+2,5 1,5+1,5+1,8+1,8+2,5+3,5 * Minimum 4 units to be connected; at least 2 per each refrigerant cycle FIVE UNITS FIVE UNITS SIX UNITS 46

RAC Residential POSSIBLE COMBINATIONS RAM-110NP6B RAM-110NP6B RAM-110NP6B RAM-110NP6B RAM-110NP6B SIX UNITS 1,5+1,5+1,8+1,8+3,5+3,5 1,5+1,5+5,0+1,5+2,5+3,5 1,5+1,8+3,5+1,5+1,5+2,5 1,5+2,5+2,5+1,8+1,8+5,0 1,8+1,8+3,5+1,8+1,8+3,5 1,5+1,5+1,8+2,5+2,5+2,5 1,5+1,5+5,0+1,5+3,5+3,5 1,5+1,8+3,5+1,5+1,5+3,5 1,5+2,5+2,5+1,8+2,5+2,5 1,8+1,8+3,5+1,8+1,8+5,0 1,5+1,5+1,8+2,5+2,5+3,5 1,5+1,5+5,0+1,8+1,8+1,8 1,5+1,8+3,5+1,5+1,5+5,0 1,5+2,5+2,5+1,8+2,5+3,5 1,8+1,8+5,0+1,8+1,8+5,0 1,5+1,5+2,5+1,5+1,5+1,5 1,5+1,5+5,0+1,8+1,8+2,5 1,5+1,8+3,5+1,5+1,8+1,8 1,5+2,5+2,5+1,8+3,5+3,5 1,8+1,8+2,5+1,8+2,5+2,5 1,5+1,5+2,5+1,5+1,5+1,8 1,5+1,5+5,0+1,8+1,8+3,5 1,5+1,8+3,5+1,5+1,8+2,5 1,5+2,5+2,5+2,5+2,5+2,5 1,8+1,8+2,5+1,8+2,5+3,5 1,5+1,5+2,5+1,5+1,5+2,5 1,5+1,5+5,0+1,8+1,8+5,0 1,5+1,8+3,5+1,5+1,8+3,5 1,5+2,5+2,5+2,5+2,5+3,5 1,8+1,8+5,0+1,8+2,5+2,5 1,5+1,5+2,5+1,5+1,5+3,5 1,5+1,5+5,0+1,8+2,5+2,5 1,5+1,8+3,5+1,5+1,8+5,0 1,5+2,5+3,5+1,5+1,5+1,5 1,8+1,8+3,5+1,8+2,5+3,5 1,5+1,5+2,5+1,5+1,5+5,0 1,5+1,5+5,0+1,8+2,5+3,5 1,5+1,8+3,5+1,5+2,5+2,5 1,5+2,5+3,5+1,5+1,5+1,8 1,8+1,8+5,0+1,8+2,5+3,5 1,5+1,5+2,5+1,5+1,8+1,8 1,5+1,5+5,0+1,8+3,5+3,5 1,5+1,8+3,5+1,5+2,5+3,5 1,5+2,5+3,5+1,5+1,5+2,5 1,8+1,8+3,5+1,8+3,5+3,5 1,5+1,5+2,5+1,5+1,8+2,5 1,5+1,5+5,0+2,5+2,5+2,5 1,5+1,8+3,5+1,5+3,5+3,5 1,5+2,5+3,5+1,5+1,5+3,5 1,8+1,8+5,0+1,8+3,5+3,5 1,5+1,5+2,5+1,5+1,8+3,5 1,5+1,5+5,0+2,5+2,5+3,5 1,5+1,8+3,5+1,8+1,8+1,8 1,5+2,5+3,5+1,5+1,5+5,0 1,8+2,5+2,5+1,8+2,5+2,5 1,5+1,5+2,5+1,5+1,8+5,0 1,5+1,8+1,8+1,5+1,5+1,5 1,5+1,8+3,5+1,8+1,8+2,5 1,5+2,5+3,5+1,5+1,8+1,8 1,8+2,5+2,5+1,8+2,5+3,5 1,5+1,5+2,5+1,5+2,5+2,5 1,5+1,8+1,8+1,5+1,5+1,8 1,5+1,8+3,5+1,8+1,8+3,5 1,5+2,5+3,5+1,5+1,8+2,5 1,8+1,8+5,0+2,5+2,5+2,5 1,5+1,5+2,5+1,5+2,5+3,5 1,5+1,8+1,8+1,5+1,5+2,5 1,5+1,8+3,5+1,8+1,8+5,0 1,5+2,5+3,5+1,5+1,8+3,5 1,8+2,5+3,5+1,8+2,5+3,5 1,5+1,5+2,5+1,5+3,5+3,5 1,5+1,8+1,8+1,5+1,5+3,5 1,5+1,8+3,5+1,8+2,5+2,5 1,5+2,5+3,5+1,5+1,8+5,0 1,8+1,8+5,0+2,5+2,5+3,5 1,5+1,5+2,5+1,8+1,8+1,8 1,5+1,8+1,8+1,5+1,5+5,0 1,5+1,8+3,5+1,8+2,5+3,5 1,5+2,5+3,5+1,5+2,5+2,5 1,8+2,5+3,5+1,8+3,5+3,5 1,5+1,5+2,5+1,8+1,8+2,5 1,5+1,8+1,8+1,5+1,8+1,8 1,5+1,8+3,5+1,8+3,5+3,5 1,5+2,5+3,5+1,5+2,5+3,5 1,8+3,5+3,5+1,8+3,5+3,5 1,5+1,5+2,5+1,8+1,8+3,5 1,5+1,8+1,8+1,5+1,8+2,5 1,5+1,8+3,5+2,5+2,5+2,5 1,5+2,5+3,5+1,5+3,5+3,5 1,8+2,5+2,5+2,5+2,5+2,5 1,5+1,5+2,5+1,8+1,8+5,0 1,5+1,8+1,8+1,5+1,8+3,5 1,5+1,8+3,5+2,5+2,5+3,5 1,5+2,5+3,5+1,8+1,8+1,8 1,8+2,5+3,5+2,5+2,5+2,5 1,5+1,5+2,5+1,8+2,5+2,5 1,5+1,8+1,8+1,5+1,8+5,0 1,5+1,8+5,0+1,5+1,5+1,5 1,5+2,5+3,5+1,8+1,8+2,5 1,8+2,5+3,5+2,5+2,5+3,5 1,5+1,5+2,5+1,8+2,5+3,5 1,5+1,8+1,8+1,5+2,5+2,5 1,5+1,8+5,0+1,5+1,5+1,8 1,5+2,5+3,5+1,8+1,8+3,5 1,8+3,5+3,5+2,5+2,5+3,5 1,5+1,5+2,5+1,8+3,5+3,5 1,5+1,8+1,8+1,5+2,5+3,5 1,5+1,8+5,0+1,5+1,5+2,5 1,5+2,5+3,5+1,8+1,8+5,0 2,5+2,5+2,5+2,5+2,5+2,5 1,5+1,5+2,5+2,5+2,5+2,5 1,5+1,8+1,8+1,5+3,5+3,5 1,5+1,8+5,0+1,5+1,5+3,5 1,5+2,5+3,5+1,8+2,5+2,5 2,5+2,5+2,5+2,5+2,5+3,5 1,5+1,5+2,5+2,5+2,5+3,5 1,5+1,8+1,8+1,8+1,8+1,8 1,5+1,8+5,0+1,5+1,5+5,0 1,5+2,5+3,5+1,8+2,5+3,5 2,5+2,5+3,5+2,5+2,5+3,5 1,5+1,5+3,5+1,5+1,5+1,5 1,5+1,8+1,8+1,8+1,8+2,5 1,5+1,8+5,0+1,5+1,8+1,8 1,5+2,5+3,5+1,8+3,5+3,5-1,5+1,5+3,5+1,5+1,5+1,8 1,5+1,8+1,8+1,8+1,8+3,5 1,5+1,8+5,0+1,5+1,8+2,5 1,5+2,5+3,5+2,5+2,5+2,5 - SIX UNITS SIX UNITS 1,5+1,5+3,5+1,5+1,5+2,5 1,5+1,8+1,8+1,8+1,8+5,0 1,5+1,8+5,0+1,5+1,8+3,5 1,5+2,5+3,5+2,5+2,5+3,5-1,5+1,5+3,5+1,5+1,5+3,5 1,5+1,8+1,8+1,8+2,5+2,5 1,5+1,8+5,0+1,5+1,8+5,0 1,5+3,5+3,5+1,5+1,5+1,5-1,5+1,5+3,5+1,5+1,5+5,0 1,5+1,8+1,8+1,8+2,5+3,5 1,5+1,8+5,0+1,5+2,5+2,5 1,5+3,5+3,5+1,5+1,5+1,8-1,5+1,5+3,5+1,5+1,8+1,8 1,5+1,8+1,8+1,8+3,5+3,5 1,5+1,8+5,0+1,5+2,5+3,5 1,5+3,5+3,5+1,5+1,5+2,5-1,5+1,5+3,5+1,5+1,8+2,5 1,5+1,8+1,8+2,5+2,5+2,5 1,5+1,8+5,0+1,5+3,5+3,5 1,5+3,5+3,5+1,5+1,5+3,5-1,5+1,5+3,5+1,5+1,8+3,5 1,5+1,8+1,8+2,5+2,5+3,5 1,5+1,8+5,0+1,8+1,8+1,8 1,5+3,5+3,5+1,5+1,5+5,0-1,5+1,5+3,5+1,5+1,8+5,0 1,5+1,8+2,5+1,5+1,5+1,5 1,5+1,8+5,0+1,8+1,8+2,5 1,5+3,5+3,5+1,5+1,8+1,8-1,5+1,5+3,5+1,5+2,5+2,5 1,5+1,8+2,5+1,5+1,5+1,8 1,5+1,8+5,0+1,8+1,8+3,5 1,5+3,5+3,5+1,5+1,8+2,5-1,5+1,5+3,5+1,5+2,5+3,5 1,5+1,8+2,5+1,5+1,5+2,5 1,5+1,8+5,0+1,8+1,8+5,0 1,5+3,5+3,5+1,5+1,8+3,5-1,5+1,5+3,5+1,5+3,5+3,5 1,5+1,8+2,5+1,5+1,5+3,5 1,5+1,8+5,0+1,8+2,5+2,5 1,5+3,5+3,5+1,5+1,8+5,0-1,5+1,5+3,5+1,8+1,8+1,8 1,5+1,8+2,5+1,5+1,5+5,0 1,5+1,8+5,0+1,8+2,5+3,5 1,5+3,5+3,5+1,5+2,5+2,5-1,5+1,5+3,5+1,8+1,8+2,5 1,5+1,8+2,5+1,5+1,8+1,8 1,5+1,8+5,0+1,8+3,5+3,5 1,5+3,5+3,5+1,5+2,5+3,5-1,5+1,5+3,5+1,8+1,8+3,5 1,5+1,8+2,5+1,5+1,8+2,5 1,5+1,8+5,0+2,5+2,5+2,5 1,5+3,5+3,5+1,5+3,5+3,5-1,5+1,5+3,5+1,8+1,8+5,0 1,5+1,8+2,5+1,5+1,8+3,5 1,5+1,8+5,0+2,5+2,5+3,5 1,5+3,5+3,5+1,8+1,8+1,8-1,5+1,5+3,5+1,8+2,5+2,5 1,5+1,8+2,5+1,5+1,8+5,0 1,5+2,5+2,5+1,5+1,5+1,5 1,5+3,5+3,5+1,8+1,8+2,5-1,5+1,5+3,5+1,8+2,5+3,5 1,5+1,8+2,5+1,5+2,5+2,5 1,5+2,5+2,5+1,5+1,5+1,8 1,5+3,5+3,5+1,8+1,8+3,5-1,5+1,5+3,5+1,8+3,5+3,5 1,5+1,8+2,5+1,5+2,5+3,5 1,5+2,5+2,5+1,5+1,5+2,5 1,5+3,5+3,5+1,8+1,8+5,0-1,5+1,5+3,5+2,5+2,5+2,5 1,5+1,8+2,5+1,5+3,5+3,5 1,5+2,5+2,5+1,5+1,5+3,5 1,5+3,5+3,5+1,8+2,5+2,5-1,5+1,5+3,5+2,5+2,5+3,5 1,5+1,8+2,5+1,8+1,8+1,8 1,5+2,5+2,5+1,5+1,5+5,0 1,5+3,5+3,5+1,8+2,5+3,5-1,5+1,5+5,0+1,5+1,5+1,5 1,5+1,8+2,5+1,8+1,8+2,5 1,5+2,5+2,5+1,5+1,8+1,8 1,5+3,5+3,5+1,8+3,5+3,5-1,5+1,5+5,0+1,5+1,5+1,8 1,5+1,8+2,5+1,8+1,8+3,5 1,5+2,5+2,5+1,5+1,8+2,5 1,5+3,5+3,5+2,5+2,5+2,5-1,5+1,5+5,0+1,5+1,5+2,5 1,5+1,8+2,5+1,8+1,8+5,0 1,5+2,5+2,5+1,5+1,8+3,5 1,5+3,5+3,5+2,5+2,5+3,5-1,5+1,5+5,0+1,5+1,5+3,5 1,5+1,8+2,5+1,8+2,5+2,5 1,5+2,5+2,5+1,5+1,8+5,0 1,8+1,8+1,8+1,8+1,8+1,8-1,5+1,5+5,0+1,5+1,5+5,0 1,5+1,8+2,5+1,8+2,5+3,5 1,5+2,5+2,5+1,5+2,5+2,5 1,8+1,8+1,8+1,8+1,8+2,5-1,5+1,5+5,0+1,5+1,8+1,8 1,5+1,8+2,5+1,8+3,5+3,5 1,5+2,5+2,5+1,5+2,5+3,5 1,8+1,8+1,8+1,8+1,8+3,5-1,5+1,5+5,0+1,5+1,8+2,5 1,5+1,8+2,5+2,5+2,5+2,5 1,5+2,5+2,5+1,5+3,5+3,5 1,8+1,8+1,8+1,8+1,8+5,0-1,5+1,5+5,0+1,5+1,8+3,5 1,5+1,8+2,5+2,5+2,5+3,5 1,5+2,5+2,5+1,8+1,8+1,8 1,8+1,8+2,5+1,8+1,8+2,5-1,5+1,5+5,0+1,5+1,8+5,0 1,5+1,8+3,5+1,5+1,5+1,5 1,5+2,5+2,5+1,8+1,8+2,5 1,8+1,8+2,5+1,8+1,8+3,5-1,5+1,5+5,0+1,5+2,5+2,5 1,5+1,8+3,5+1,5+1,5+1,8 1,5+2,5+2,5+1,8+1,8+3,5 1,8+1,8+2,5+1,8+1,8+5,0 - SIX UNITS SIX UNITS 47

Product comparison WALL Premium Akebono Cut Out Performance Functions Filter RC Capacity (Cooling) 18/25/35 18/25/35/50 18/25/35/50 15/18/25 35/50 18/25/35/50 Code RAK PSB RAK RXB (RAK18QXB) RAK QXA RAK RPB (RAK15QPB) RAK RPB ECO Sensor (human activity and positioning detecting) - - - - - Leave Home Timer Air Purify Auto Swing ECO Sensor (human absence) - - - - - ECO (without sensor) - - Powerful Silent (Day timer) (1-99) (1-99) (1-99) (1-99) (1-99) RAK QPA Set Temperature ( C) 10 10-16 10 10-16 10-16 10 Weekly 24h 12h - - - - - - Eco Sleep 1-2-3-7 (h) Stainless Clean - - - - Auto fi lter cleaning - - - - - Ionized Mist - - - - - up-down right-left - - Power consumption display Room Temperature Display Remocon Operation Lock Air purifying fi lter Pre-fi lter Remocon IU DSW DSW One Touch Clean Extended Airfl ow - - - - - - DSW DSW DSW (1-99) Dry contact SPX-WDC3 SPX-WDC3 SPX-WDC1 SPX-WDC3 SPX-WDC3 SPX-WDC1 Auto Restart Auto Changeover ID Switch Software (remocon) Software (remocon) Software (remocon) Software (remocon) Software (remocon) Self diagnosis digital display DSW Software (remocon)) Cable number between IU and OU 3 + earth 3 + earth 2 + earth 3 + earth 3 + earth 2 + earth standard - optional standard Wasabi SPX-CFH22 Micro Mesh Inox Wasabi SPX-CFH22 Wasabi SPX-CFH22 opzionale - - - Wasabi SPX-CFH22 Wasabi SPX-CFH22 Wasabi SPX-CFH22 - - - - - Inox Washable Washable Washable Washable Inox SPX-SPF6 Inox SPX-SPF7 standard remocon parts no. RAR-5W1 RAR-6N1 RAR-5E2 RAR-6N2 RAR-6N1 RAR-5E1 optional simple wired weekly timer wireless (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) - (SPX-RCDB) 48

RAC Residential WALL FLOOR DUCT CASSETTE Performance Eco Comfort Akebono Cut Out Performance Low static pressure Medium static press. Medium static press. 4 ways 4 ways 60 70 18/25/35/50 25/35/50 25/35/50 25/35/50 18/25/35/50 18/25/35/50 50/60/70 25/35/50 25/35/50 RAK PPA RAK PPA RAK PEB RAF RXB RAF QXA RAF RPA RAD RPA RAD QPB RAD PPA RAI RPA RAI QPB - - - - - - - - - - - - - - - - - - - - - - ( ) ( ) ( ) ( ) ( ) ( ) - ( ) ( ) ( ) (1-99) (1-99) (1-99) (1-99) (1-99) 10 10 10 10-16 10 10 10 10-16 10 10 10-16 - ( ) ( ) ( ) - ( ) ( ) ( ) - - - - - - - - - - - ( ) ( ) ( ) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ( ) ( ) ( ) - ( ) ( ) ( ) - ( ) ( ) ( ) DSW DSW DSW DSW DSW DSW - ( ) ( ) ( ) - - - - - - - - - SPX-WDC4 SPX-WDC4 SPX-WDC3 SPX-WDC3 SPX-WDC1 SPX-WDC1 SPX-WDC2 SPX-WDC2 SPX-WDC2 SPX-WDC2 SPX-WDC2 - ( ) ( ) ( ) Software (remocon) Software (remocon)) DSW (IU) Jumper Wire (remocon) Software (remocon) Software (remocon) Software (remocon) ( ) (1-99) DSW Software (remocon) ( ) (1-99) DSW Software (remocon) ( ) (1-99) DSW Software (remocon) (1-99) DSW Software (remocon) - ( ) ( ) ( ) (1-99) DSW Software (remocon) 4 + earth 4 + earth 3 + earth 3 + earth 2 + earth 2 + earth 2 + earth 3 + earth 4 + earth 2 + earth 3 + earth Wasabi SPX-NTW1 Wasabi SPX-NTW2 - Nano Titanium SPX-CFH15 Nano Titanium Nano Titanium SPX-CFH15 - - - - - - - Wasabi SPX-CFH22 - - - - - - Wasabi SPX-NTW1 Wasabi SPX-NTW1 Washable Washable Washable Nano Inox Washable Inox Washable - Washable Washable Washable Inox SPX-SPF3 Inox SPX-SPF4 Inox SPX-SPF6 - - - - - - - - RAR-5E2 RAR-5E1 RAR-5F1 RAR-6N4 RAR-5E4 RAR-5E2 no STD no STD no STD RAR-5E2 RAR-6N2 (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDB) (SPX-RCDA) (SPX-RCDA) (SPX-RCDA) (SPX-RCDB) (SPX-RCDB) (SPX-RCKA) (SPX-RCKA1) (SPX-RCKA) 49

Functions ECO MODE It limits the energy consumption for providing always a high efficiency working (with human activity and position detection sensor, with human absence sensor, without sensor). POWERFUL The system works at the maximum capacity in heating and cooling for 20 minutes for quickly satisfying the comfort request. After the 20 minutes the system is automatically reset to starting condition. SILENT MODE The silent mode offers the possibility of reducing noise level of the indoor unit by lowering the fan speed. LEAVE HOME This function prevents the room temperature from falling too much (lower than 10 C) when the house is not occupied for long time during winter. It is possible to set the duration of LEAVE HOME function (from 0 to 99 giorni) for the required period. For some models the minimum temperature can be selected (from 10 C to 16 C). At the end of the selected period the unit will work according to the set temperature previously selected. TIMER For all indoor units it is possible to set ON/OFF by means of a timer integrated in the remocon. Depending on the model the scheduling can be done on a weekly base or on 24 h or only on 12h. SLEEP TIMER The countdown can be set for up to 7 hours. Temperature regulation (±2 C) and the reduction of the fan speed provide comfortable sleeps and a great energy saving. INFO Three different parameters can be selected by means of INFO button. Room temperature: the thermistor mounted on the remocon allows to visualise on the display the information of room temperature. Energy consumption indication : the monthly energy consumption can be displayed (current and previous month). Self Diagnosis codes: in case of malfunctioning, the LCD remocon displays the error code for facilitating the service operations. 50

RAC Residential VERTICAL SWING Air flow rate vertically orientable by means of motorised louvers (for all models). ONE TOUCH CLEAN Drying the evaporator for preventing mould formation and bad odours. The activation of this function is suggested during summer. SWING ORIZZONTALE Air flow horizontally orientable by means of motorised louvers (for some models only). STAINLESS CLEAN Some intenal part of the air conditioner are in stainless steel for providing the highest cleaning of the treated air, reducing bacteria proliferation. Thanks to stainless steel the air conditioner is kept clean for very long time. EXTENDED AIRFLOW Airflow can be boosted for reaching the farthest areas of the room. ION MIST A ionized mist mechanism is able to refresh the air by ionising the water droplets with high voltage and emitting them into the room. These nano-sized ionized mist decomposes and significantly lowers the concentration of bacteria, fungi and pollens from indoor air. AUTO-FILTER CLEANING By simply pressing a button on the remocon, a robotic arm with a brush positioned on the prefilters automatically cleans the indoor unit. Dust and bacteria are collected in a small box in the indoor unit and neutralised by a wasabi filter. The user should only empty the box and wash it in warm water each two years. DRY CONTACT For all the indoor units a dry contact kit is available for enabling/disabling the remote activation of the unit. Typical applications are window contact (the indoor unit is switched off for energy saving when a window is opened) or badge contact (the unit is switched off when the badge is removed from its slot). AUTORESTART Auto restart function is available n case of discontinuity of power supply. It can be disabled by means of a dip switch. MODE LOCK Is it possible to lock the working mode only in COO- LING (+FAN MODE), or only HEATING (+FAN MODE), or only DEHUMIDIFYING (+FAN MODE). AUTO MODE In AUTO mode, the air conditioner automatically selects the working mode (cooling or heating) according to the indoor air temperature which is read. The working mode changes according to temperature. In case of MULTI combinations the working mode does not change. ID SWITCH When two indoor units are installed very close between them in the same environment, the IR frequency can be differentiated on the remocon, for preventing to confuse individual control signal. 51

NOTE 52

NOTE 53

HITACHI S ALARM CODE APP The new APP is now available to provide you with instantaneous, round the clock access to alarm codes and technical details, thus making your job even easier and quicker. The ios and Android version is available as of now, to be followed shortly by the WEB APP version as well. For a professional and guaranteed service, always and in any case contact an authorised HITACHI Service Centre. 54