Washer Test Kits User Guide

Similar documents
ProFormanceTM Cleaning Verification Products

Cleaning Verification

The Principles, The Process, and The Results:

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

Steam Sterilization and Sterility Assurance in Health Care Facilities ANSI/AAMI ST79. Suzanne Latta, CSPDT. Education Materials Coordinator

STERITITE INSTRUCTIONS FOR USE

ANSI/AAMI ST79: Comprehensive guide to steam sterilization and sterility assurance in health care facilities. Suzanne Latta, CSPDT

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

When you sterilize an instrument set, you know what the standards are.

Page 2 of 5. SOP SF SOP for Water Bath Maintenance

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

FLASH PAK STERILIZATION CONTAINER SYSTEM

Instructions for Use Spinal Punches IFU

Cleaning & Sterilization

In 2011 JCAHO in standard E.C.6.20; states that all medical equipment is maintained, tested and inspected (2).

Improving the Performance of Your Medical Automatic Washer

8/18/2014. Welcome! How do I get a CE Certificate?

PINNACLE MONITOR FOR AUTOMATED ENZYMATIC CLEANING (AEC) PROCESS

The Journal of ProFormance TM Monitoring

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

CLEANING INSTRUCTIONS

AMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare

Lower Your Costs. Expand Your Flexibility.

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Lower Your Costs. Expand Your Flexibility.

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

Disinfecting And Sanitizing Animal Facilities

Accurately With HSE COP PT 1 5

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

THE BASICS OF DECONTAMINATION

User Guide for Reprocessing of the SUPER VIEW Wide Angle Viewing System Sterilizable Components and Accessories

RECOMMENDATIONS FOR CLEANING DEVICES

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

CASTLE 8666 LABORATORY GLASSWARE WASHING ACCESSORIES

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

SteelcoSure Independent performance verification of your equipment and processes

M 115 M 150 M 150 A M 130 M 180 M 180 A SERIE. Undercounter dishwashers Vegetable washers. Glasswashers. Pass through. dishwashers.

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

The Hydrim C51wd Washer Disinfector. Perfectly prepares instruments for sterilisation in as little as 19 minutes.

AZTECA A LITRE STERILISER

Pharmaceutical washing-systems

REGULAR MAINTENANCE AND CARE

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

Policy # MI_WASH Department of Microbiology. Page Quality Manual TABLE OF CONTENTS APPENDIX I STERILIZATION AND GLASS WASHING TECHNICAL MANUAL...

GETINGE 9027 FLOOR-LOADED CART WASHER-DISINFECTOR. Always with you

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

CLEANING FOR INFECTION CONTROL Ultrasonic Cleaners. Ultrasonic Cleaners. Copyright Quality Medical Innovations P/L & Majac Medical Products P/L

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

SOP SF SOP for LN2 Freezers

PICNet CONFERENCE 2013

Surgical Instrument Cleaning Process

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

Call our hotline at for all your instrument care and detergent questions. Medline Super Concentrates

Bravo Display Warning Messages

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

For routine maintenance of polished granite installations with a cleaner and protector:

DEKO Washer-disinfector WASHROOM SYSTEMS

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

ST-1 Surface Treatment

IBC Wash: Critical Cleaning Solution for IBCs, Totes and Tablet Bins.

AUTOMATIC STERILIZERS

GIRTON CABINET WASHER MODEL 794A

Procedures in University Laboratory. August 25, 2010 ULAR Continuing Education & Professional Development Class

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

Instructions for Use: Fiberscope and LED Light Source

Operator s Manual. HYDRIM L110w Operator's Manual Rev. 2.0 Copyright 2003 SciCan. All rights reserved.

INSTRUCTION MANUAL. Blue Whale Spa Ltd, 11 Glaisdale Drive East Nottingham, NG8 4GU

Aesculap Implant Systems

Ultrasonic From delicate microsurgery instruments to heavy duty sets

CIP Technologies. August 1st, 2017

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

Disclosure. Running a Medical Devise Reprocessing Department(MDRD) requires a lot of Knowledge

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

The Hydrim M2 washer disinfector. Perfectly prepares large volumes of instruments for sterilisation.

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Your Health, our Technology AWD655. Instrument Washer Disinfector

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

GETINGE WD15 CLARO 1 GETINGE WD15 CLARO THE CLEAR CHOICE IN WASHER-DISINFECTORS. Always with you

Sterilization pouches. Instructions for Use

FOOD SAFETY PRODUCT PORTFOLIO MEAT INDUSTRY

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Version 7 1/ LXP

Version 7 1/ LX

Celebrating over 30 years of excellence in manufacturing ultrasonic cleaning equipment, electropolishing equipment and associated chemistries

Transcription:

Washer Test Kits User Guide This user guide is to show how to measure water temperature, water quality, and cleaning efficiency for the following ProFormance Washer Kits: 1. 3 Level Washer Test Kit (AWTK-3L) 2. 4 Level Washer Test Kit (AWTK-4L) 3. Single Level Tunnel Washer Test Kit 4. TOSI Only 3 Level Washer Test Kit 5. TOSI Only 4 level Washer Test Kit All parameters cited by AORN (Recommended Practices for Cleaning and Care of Surgical Instruments and Powered Equipment, Section XXII.a) and ANSI/AAMI ST79:2017 Comprehensive guide to steam sterilization and sterility assurance in health care facilities and is crucial for the routine testing of instrument reprocessing. Table of Contents Page # 3 Level Washer Test Kit 2-4 4 Level Washer Test Kit 5-7 Single Level Tunnel Washer Test Kit 8-10 TOSI Only 3 Level Washer Test Kit 11-12 TOSI Only 4 Level Washer Test Kit 13-14 1

3 Level Washer Test Kit ProFormance Washer Monitoring Log Sheet: 3 Level Rack (AWTK-3L) 1. Record the Date, Facility, Washer and Rack No, and the name of the technician recording the test results. 2. To record the water quality to get the target values, use the AquaTest strips to accurately show the ph Level, Alkalinity, and Hardness of the water. Take an AquaTest strip and dip the strip into water for 5 seconds, then remove. Shake the strip once briskly to remove access water and wait 20 seconds. Compare each pad to the corresponding color chart to determine the value for ph, Alkalinity and hardness. 3. The Target Values are to be established the first time the test is done or have specific recommendations from the detergent manufacturer. Circle the value on the color chart that is shown on the pad for ph, Alkalinity and Hardness for both cold water and hot water. Include comments if necessary. 4. TempaChek -90- Look through the window of the washer during the cold water rinse to see what the temperature is. Record the results by darkening the temperatures reached on the TempaChek-90 (which should not exceed 100ºF). Circle the results Pass or Fail and include any comments if necessary. 5. Verification of Cleaning Efficacy TOSI - After the TOSI has gone through the washer cycle, circle the results for each TOSI that was placed on all three racks. The range is from 0 to 5. 0- coupon is clean, 5- coupon still has considerable amount of test soil remaining on it. Please consult the TOSI Interpretation Guide. Include any comments if necessary. 2

6. Thermal Disinfection TempaChek -170- To record the results of the TempaChek-170, circle the highest temperature achieved on each of the temperature strips. The target temperature will come from the manufacturer of the washer and put that temperature in the Target Temp. box. If the result is below that temperature, it is a failure. Include any comments if necessary. 7. Washer Chamber and Racks- Record the date for the test results of the top and bottom washer chamber and the top and bottom racks. 8. Check the yes or no boxes for each section of the washer chamber and Racks. Include any observations that may have been identified with recommended actions and additional comments if necessary. 9. The next section requires a Yes or No for debris, staining or scaling, detergent at a sufficient level in the container, and cycle settings reviewed for the bottom chamber. 3

Include any observations that may have been identified with recommended actions and additional comments if necessary. 4

4 Level Washer Test Kit ProFormance Washer Monitoring Log Sheet: 4 Level Rack (AWTK-4L) 1. Record the date, facility, washer and rack No, and the name of the technician recording the test results. 2. To record the water quality to get the target values, use the AquaTest strips to accurately show the ph Level, Alkalinity, and Hardness of the water. Take an AquaTest strip and dip the strip into water for 5 seconds, then remove. Shake the strip once briskly to remove access water and wait 20 seconds. Compare each pad to the corresponding color chart to determine the value for ph, Alkalinity and hardness. 3. The Target Values are to be established the first time the test is done or have specific recommendations from the detergent manufacturer. Circle the value on the color chart that is shown on the pad for ph, Alkalinity and Hardness for both cold water and hot water. Include comments if necessary. 4. TempaChek -90- Look through the window of the washer during the cold-water rinse to see what the temperature is. Record the results by darkening the temperatures reached on the TempaChek-90 (which should not exceed 100ºF). Circle the results Pass or Fail and include comments if necessary. 5. Verification of Cleaning Efficacy TOSI - After the TOSI has gone through the wash cycle circle the results for each TOSI that was placed on all four racks. The range is from 0 to 5. 0- coupon is clean, 5- coupon still has considerable amount of test soil remaining on it. Please consult with the TOSI Interpretation Guide. Include comments if necessary. 5

6. Thermal Disinfection TempaChek -170- To record the results of the TempaChek-170, circle the highest temperature achieved on each of the temperature strips. The target temperature will come from the manufacturer washer and put that temperature in the Target Temp. box. Include comments if necessary. 7. Washer Chamber and Racks- Record the date for the test results of the top and bottom washer chamber and the top and bottom racks. 8. Check the yes or no boxes for each section of the Bottom, Top chamber and Bottom, Middle and Top Racks. Include any observations that may have been identified with recommended actions and additional comments if necessary. 6

9. The next section requires a yes or no for debris, staining or scaling, detergent at a sufficient level in the container, and cycle settings reviewed for the bottom chamber. Include any observations that may have been identified with recommended actions and additional comments if necessary. 7

Single Level Tunnel Washer Test Kit ProFormance Washer Monitoring Log Sheet: 1 Level Tunnel Washer (TWTK-1L) 1. Record the date, facility, washer and rack No, and the name of the technician recording the test results. 2. To record the water quality to get the target values, use the AquaTest strips to accurately show the ph Level, Alkalinity, and Hardness of the water. Take an AquaTest strip and dip the strip into water for 5 seconds, then remove. Shake the strip once briskly to remove access water and wait 20 seconds. Compare each pad to the corresponding color chart to determine the value for ph, Alkalinity and hardness. 3. The Target Values are to be established the first time the test is done or have specific recommendations from the detergent manufacturer. Circle the value on the color chart that is shown on the pad for ph, Alkalinity and Hardness for both cold water and hot water. Include comments if necessary. 4. TempaChek -90- Look through the window of the washer during the cold water rinse to see what the temperature is. Record the results by darkening the temperatures reached on the TempaChek-90 (which should not exceed 100ºF). Circle the results Pass or Fail and include comments if necessary. 3. Verification of Cleaning Efficacy TOSI - After the TOSI has gone through the wash cycle circle the results for each TOSI that was placed on that rack. The range is from 0 to 5. 0- coupon is clean, 5- coupon still has considerable amount of test soil remaining on it. Please consult the TOSI Interpretation Guide. Include comments if necessary. 8

4. Thermal Disinfection TempaChek -170- To record the results of the TempaChek-170, circle the highest temperature achieved on each of the temperature strips and put in the Target Temp. in the yellow and white box. Include comments if necessary. 5. Cavitation Test SonoCheck - Place one test in the sonic, after the cycle is complete circle the resulting color of the SonoCheck, Green is before cavitation and yellow is after. Include comments if necessary. 6. Prewash Chamber, Wash Chamber and Disinfect Chamber- Record the date for the test results of the top and bottom and sides of each chamber. 7. Check the box for yes or no for the Bottom, Top and Sides of the Prewash, Wash and Disinfect Chambers. Include any observations that may have been identified with recommended actions and additional comments if necessary. 9

8. The next section requires a yes or no for debris, staining or scaling, detergent at a sufficient level in the container, and cycle settings reviewed for the prewash and wash chambers, and disinfect chamber. Include any observations that may have been identified with recommended actions and additional comments if necessary. 10

TOSI Only ProFormance TM Log Sheet: 3 Level Rack (WTK-3L) 1. Record the Date, Facility, Washer and Rack No, and the name of the technician recording the test results. 2. Check the yes or no boxes for the Bottom, and Top of the Chamber and Racks. Include any observations that may have been identified with recommended actions and additional comments if necessary. 3. The next section requires a Yes or No for debris, instrument rack coupling, staining or scaling, detergent at a sufficient level in the container, and cycle settings reviewed for the prewash and wash chambers, and disinfect chamber. Include any observations that may have been identified with recommended actions and additional comments if necessary. 11

4. TOSI - After the TOSI has gone through the wash cycle circle the results for each TOSI that was placed all three racks. The range is from 0 to 5. 0- coupon is clean, 5- coupon still has considerable amount of test soil remaining on it. Please consult the TOSI Interpretation Guide. Include comments if necessary. 12

TOSI Only ProFormance Log Sheet: 4 Level Rack (WTK-4L) 1. Record the Date, Facility, Washer and Rack No, and the name of the technician recording the test results. 2. Check the yes or no boxes for the Bottom, and Top of the Chamber and Bottom, Middle and Top Racks. Include any observations that may have been identified with recommended actions and additional comments if necessary. 3. The next section requires a Yes or No for debris, instrument rack coupling, staining or scaling, detergent at a sufficient level in the container, and cycle settings reviewed for the Chamber. Include any observations that may have been identified with recommended actions and additional comments if necessary. 13

4. TOSI - After the TOSI has gone through the wash cycle circle the results for each TOSI that was placed all four racks. The range is from 0 to 5. 0- coupon is clean, 5- coupon still has considerable amount of test soil remaining on it. Include comments if necessary. 14