Gemini. Gemini Instruction Booklet. Addressable & Conventional versions GE-IB-06/18-01

Similar documents
ZC450-IB-09/13-01 US. Instruction Booklet. Zonecheck 450

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

CZ-6A Six Zone Interface Module

SC-6 Six Supervised Control Module

LMA LINE MONITOR ALERT USER S MANUAL

D2E Duct Smoke Detector

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

RK/ RK Combustible Gas Detector Operator s Manual

aquamanta the experts in aquatic technology

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Installation Manual. Models 99168, 99169, 99170

Spa Control System OWNER S MANUAL

52 BERKSHIRE CEILING FAN

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

Universal Fan and Light Remote Control

RK / RK Methane Detector Operator s Manual

1400 Direct Wire Ionization Smoke Detector

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

52 BARSTOW CEILING FAN

52 BAYTOWNE CEILING FAN

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

640 Series Advanced Remote Vehicle Security System

52 SAN LUCAS CEILING FAN

LGR Dehumidifier Owner s Manual

52 STRATHMERE CEILING FAN

48 TAYLOR CEILING FAN

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

MOTORCYCLE RADAR & LASER DETECTION SYSTEM TPX VISUAL ALERT MANUAL

DH100ACDCI Ionization Air Duct Smoke Detector

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

INSTALLATION, OPERATION AND MAINTENANCE

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

ion Genesis Pump Controller

User s Manual For Model Aero-551 (Rev. Orig.)

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

DH100ACDCI Ionization Air Duct Smoke Detector

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

INSTALLATION INSTRUCTIONS

Master Prep Frozen Treat & Drink Maker

ESP TECHNOLOGIES LIMITED

RK/ RK Oxygen Detector Operator s Manual

STRONG International FP-350 Operation and Installation Manual

Auto Opening with Pressure Readout 15 x15 & 16 x20 Heat Transfer Machines

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Remote Relay Module (RRM)

DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø)

RK-05 Carbon Monoxide Detector Operator s Manual

DNRECL Eclipse Duct Smoke Detector

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Twin Photobeam Detectors Manual

DC CEILING FAN MODELS ICF72, ICF96

Classic & Deluxe Pants Press SPP-0669 SPP-0670

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100

52 CEILING FAN. Owner s Manual Models #50336, 50337

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

Multi Line Laser Level Model: L203

DH500 Intelligent Air Duct Smoke Detector Housing

Operation Manual Vortex mixer unitexer 1

Model 3901T / 3902T / 3903T

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

UV100E Ultraviolet Air Treatment System

Whynter Portable Ice Maker 33 lb capacity - White

OWNER S GUIDE

LOW FREQUENCY SOUNDER

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

DC CEILING FAN MODELS ICF72, ICF96

nova extreme retrofit High Output T5 Lighting Kit

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Downrod. Blades. Maintenance & Cleaning.

EclipseDryer Guide. Effective 10/09

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

ELECTRIC FIRE PUMP CONTROLLER

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

Camarillo 52 Ceiling Fan

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

HI Industrial Utility Heater HI Soleus Air International

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

BL250. Pulse Blender OWNER S GUIDE

FW-RA-LED Remote Multiplex Annunciator Panels

Beacon 800 Gas Monitor Operator s Manual

CA5000 Liquid CO 2 Freezer Backup System

RK-03 Hydrogen Detector Operator s Manual

FSW300 Series Flow Switch

Transcription:

Gemini Gemini Instruction Booklet Addressable & Conventional versions GE-IB-06/18-01

Copyright This instruction booklet is property of Project Fire Products Ltd and must not be used or copied without its written permission. Information While every effort has been made to ensure that the information contained within this document is correct, Project Fire makes no guarantee for completeness or accuracy. Project Fire Products Ltd reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligation. Gemini is a registered product name of Project Fire Products Ltd. Zonecheck is a registered product name of Project Fire Products Ltd. European patent No. 0907833. Zonecheck Addressable is a registered product name of Project Fire Products Ltd. Patent pending number PCT/GB2017/050995

Contents 01 Supplied components (Addressable version) 02 Supplied components (Conventional version) 03-04 Mechanical installation 05-06 Electrical Installation (Addressable version) 07-08 Electrical Installation (Conventional version) 09 Testing and Operation (Addressable version) 10 Testing and Operation (Conventional Version) 11 Important Information 12 Frequently Asked Questions 13 Troubleshooting 14 Warranty

Typical Components - Addressable version IMM (to connect to Addressable Controller via loop wiring) Gemini (pre-action sprinkler head) Rosette (for installation with ceilings) IMM Cable (to connect between IMM and first Gemini head on the run, 8m) Interconnecting Cable (to connect between Gemini heads, 4m) End-of-line Resistor Block (fitted into last Gemini head in run) 01

Typical Components - Conventional version Monitoring Panel Power Cable (pre-wired 5m) Gemini (pre-action sprinkler head) Panel Cable (to first Gemini head - pre-wired 8m) Rosette (for installation with ceilings) Interconnecting Cable (to connect between Gemini heads, 4m) End-of-line Resistor Block (fitted into last Gemini head in run) 02

Mechanical Installation Sprinkler pipework Coupling/Union Adaptor Gemini pre-action sprinkler head Floor Slab minimum 300mm False Ceiling 03 Recommended hole size Ø60 mm 130mm

Pre-installation Checks Ensure you have a minimum of 300mm of clear space above any false or suspended ceiling. Ensure heads are positioned in accordance with sprinkler design drawing. Recommended Ø60mm hole size for fitting into plasterboard or suspended ceilings. Ensure all necessary permissions and pre-cautions have bee taken before connecting heads to sprinkler pipework. Connecting Gemini Head to Sprinkler Pipework The Gemini sprinkler head connects to the pipework via a 1¼ (32mm) screwed coupling/union. The coupling is to be screwed onto the adaptor using a wrench or spanner on the hexagon of the adaptor, never at the sprinklers! Repeat this task for all heads to be fitted. Mounting Monitoring Panel (conventional installations) Mount monitoring panel to a wall in a suitable location. The panel should be located at a convenient visible height, easily accessible and preferably adjacent to any fire alarm panels. Panel provides audible and visual signal when either (or both) of the twin Gemini sprinkler heads are triggered. Mounting IMM (Addressable installations) The IMM can be mounted to a wall or pipe (using the appropriate fittings) with access for maintenance. See diagram below for clear space requirements. An audible and visual fault signal is generated on the Zonecheck Addressable Controller when either (or both) of the twin Gemini sprinkler heads are triggered. 150 CLEAR SPACE (cable entry) 301 FRONT 198 TOP 80 200 CLEAR SPACE 150 CLEAR SPACE (cable entry) 04

Electrical Installation (Addressable) Mains in (230V) 4.7KΩ (supplied) Do not remove IMM cable Wire to first Gemini Head IMM Wiring Ensure dip-switches are both in the ON (up) position loop in loop out Wiring into the IMM must be completed by a suitability experienced and competent electrician. For a list of approved Zonecheck Addressable installers, please contact Project Fire Products ltd. For more information on wiring for Zonecheck Addressable see other relevant documentation supplied with Zonecheck Addressable components or available from Project Fire Products ltd. 05

Alarm Fault System ok Electrical Installation (Addressable) Additional equipment and IMMs on the loop First Gemini head* Subsequent Gemini head(s) Last Gemini head* 1 2 2 3 00023 GE Gemini Addressable IMM power supply KEY 1. IMM cable (8m) 2. Interconnecting Cable (4m) 3. End-of-line Resistor Block *Where there is only one Gemini head is being installed on the run, connect the IMM cable into one side of the head and the end-of-line resistor block into the other Controller Remote Fire Alarm Panel System Overview Wiring connections into the Gemini heads uses simple plug-and-play cables. 06

Electrical Installation (Conventional) End-of-line resistor block Panel Cable (8m) Interconnecting Cable (4m) Interconnecting Cable (4m) First Gemini head* Subsequent Gemini head(s) Last Gemini head* Power Monitoring Panel * NOTE: Where there is only one Gemini head is being installed on the run, connect the IMM cable into one side of the head and the end-of-line resistor block into the other *Note Where there is only one Gemini head is being installed on the run, connect the pre-installed panel cable into one side of the head and the end-of-line resistor block into the other. IMPORTANT Provided only supplied equipment is used with no alterations or additions, a qualified electrician is not required to electrically install Gemini. However, adding an optional signal out relay to the monitoring panel to additional monitoring devices (see opposite page) should only be carried out by a suitably experienced and competent electrician. 07

Electrical Installation (Conventional) Adding optional signal relay out Connections for signal relay PE N L 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Monitoring Panel Spare Spare Power Panel Cable (to first Gemini head) NOTE Relay is triggered when either (or both) of the twin sprinkler heads on the Gemini unit are triggered. Signal from monitoring panel is typically wired as fault. Use contacts 7&8 for wiring to normally closed relay switches. Use contacts 9&10 for wiring to normally open relay switches. 08

Testing and Operation (Addressable) Once the complete Addressable system is fully commissioned, a simple test can be carried out to check the fault output of the Gemini units. Unplugging any of the interconnecting cables should result in a fault signal being received by the IMM unit and will display a fault on the LED side panel. This fault signal is relayed to the main Addressable Controller. The fault signal can be cleared by plugging the cable back in and performing a reset on the main Addressable Controller. There is no requirement for ongoing testing but the test described above can be repeated and included as part of the regular sprinkler servicing routine. For more information, see other Zonecheck Addressable documentation. TEST T E S T (not applicable for Gemini IMM) Test in progress Pass/Fail IMM Status IMM Label (not applicable for Gemini IMM) (not applicable for Gemini IMM) IMM Status L.E.D. Status Solid Green Flashing Green Meaning All OK Gemini Fault 09

Testing and Operation (Conventional) Once the panel is connected to mains power and all Gemini heads have been connected, a green all OK LED should be illuminated on the front of the Monitoring panel. A simple test can be carried out to check the fault output of the Gemini units. Unplugging any of the interconnecting cables should result in the horn sounding and the fault indicator LED illuminating on the monitoring panel. The fault signal can be cleared by plugging the cable back in and pressing the reset button on the front of the monitoring panel. There is no requirement for ongoing testing but the test described above can be repeated and included as part of the regular sprinkler servicing routine. For more information, see other documentation included with the monitoring panel. Horn (aubile alarm to signal fault or failure) All OK indicator (normally on) Fault indicator Reset button Horn off button (silcences alarm locally only) 10

Important Information The sprinklers are manufactured and tested to comply with the rules and specifications of international insurers and code standards. Any modification of the sprinkler in the form of painting, coating or ornamentation applied after leaving the production factory will seriously affect its operation. Sprinklers modified as above will not be guaranteed by the manufacturer and with be non-compliant. Sprinkler (brass and chrome plated) may only be installed in areas with normal atmospheric conditions. Sprinklers should only be installed by fully trained personnel. Never install defective or damaged sprinklers. All threads (fittings/sockets) must be clean and free of grease and burrs. When screwing the coupling onto the adaptor ensure the wrench/spanner sits on the hexagon of the adaptor, never at the sprinklers! When connecting the coupling to the pipework do not exceed the maximum torque of 20 NM. Exceeding this value will cause the warranty to be void should any leaks occur. A maximum clockwise turn of 180 is permitted for alignment of the sprinklers (for sprinkler alignment turn sprinklers clockwise only). 11

Frequently Asked Questions (FAQs) What is Gemini? Gemini is a device used with automatic sprinkler systems which includes twin sprinkler heads. The device gives double knock protection, i.e. both sprinkler heads have to be triggered in order for water to be discharged (out of one head only). If a single head is triggered, an alarm will sound but no water will be discharged. For more information, please contact Project Fire Products Ltd. What is the distance between the two sprinkler heads on each Gemini? 130mm What is the RTI of the Gemini sprinkler head? The Gemini is fitted with fast response, VdS approved, sprinkler heads with 3 mm bulbs and the RTI of less than 50. What is the approved spacing for the Gemini sprinklers? 9 meter square spacing. How many Gemini sprinkler heads can be installed in one area? There is no specified maximum number. Do the Gemini heads require power? Power is required for monitoring purposes only at the panel/imm. The heads operate mechanically and will discharge water in the event of a fire even without power. In the event of sprinkler heads being triggered (either accidentally, maliciously or in the event of a fire) operation, can new heads be installed on site? No. On activation the whole Gemini unit must be replaced. The Gemini is only approved when sprinkler heads are fitted at the factory. What is the recommended procedure for replacing the Gemini sprinkler? It is recommended to have one additional Gemini on site with the normal sprinkler spare box. What on going maintenance is associated with the Gemini? There is no specific routine maintenance on the mechanical mechanism on the Gemini sprinkler head. The electrical alarm signal can be tested by breaking the circuit i.e. Unplugging one of the monitoring connections, however the approval does not stipulate such routine testing. 12

Troubleshooting Addressable Installations Addressable Installations should be troubleshooted by a competent fire sprinkler installer and wiring checked by a qualified electrician. For other IMM faults, please refer to Zonecheck Addressable Controller information. No lights on IMM. Open the IMM and check the wiring against the wiring diagram. Confirm the power supply has been connected properly. IMM status light is flashing red. Check monitored lines for an open or short circuit. Gemini fault signal is not reported or fault is incorrectly displayed. Ensure that label on front of IMM states it is for Gemini. Check wiring and dip-switch positions against the information on page 5 of this booklet. Conventional Installations Any wiring issues should be troubleshooted by a competent fire sprinkler installer and wiring checked by a qualified electrician. For other IMM faults, please refer to Zonecheck Addressable Controller information. No power to monitoring panel Check power is available at the socket/terminal. Check internal wiring against page 8 of this booklet. Gemini fault signal is not displayed on the monitoring panel. Check wiring against diagram on page 7 and ensure endof-line resistor is installed in the last Gemini head on the run. 13

One Year Warranty Project Fire Products warrants its enclosed Gemini device (and additional supplied equipment included with the Gemini head) to be free from defects in materials and workmanship under normal use and service for a period of one year from date of dispatch. Project Fire Products makes no other express warranty. No agent, representative, dealer or employee of the Company has the authority to increase or alter the obligations or limitations of this warranty. The Company s obligation of this Warranty shall be limited to the repair or replacement of any part of the Gemini device (and additional supplied equipment included with the Gemini head) which is found to be defective in materials or workmanship under normal use and service during the one-year period commencing with the date of installation. After phoning Project Fire s number, 01889 271271 for a Return Authorization number, send defective units postage prepaid to Project Fire, Pasturefields Industrial Estate, Pasturefields Lane, Hixon, Staffs, ST18 0PH. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units, which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company s negligence or fault. 14

Project Fire Products Ltd. Pasturefields Industrial Estate Pasturefields Lane Hixon Staffordshire ST18 0PH t +44 (0)1889 271 271 f +44 (0)8452 800 116 www.projectfire.co.uk