Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Similar documents
Condensing Units w/ Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

horizontal air discharge outdoor discus condensing unit

Air-Cooled Condensing Units with Bitzer Compressors

Air-Cooled Condensers

3-22 HP CONDENSING UNITS Technical Guide

Center Mount Unit Coolers

Slim Contour Unit Cooler

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Profile Unit Coolers

Kramersaver Air Cooled Condensing Units

Low Flow Unit Coolers

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Air-Cooled Condensers

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

MACH N-407 Heat Pump Air-Cooled Chiller

Low Profile Unit Coolers

T H I N K I N S I D E T H E B o x

30GT FLOTRONIC AIR-COOLED CHILLERS

Commercial High-Efficiency Condensing Units

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

30GN FLOTRONIC II AIR-COOLED CHILLERS

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

SMALL AIR COOLED CONDENSERS

MAC N-407 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

PRO 3 TOP MOUNT & SIDE MOUNT PACKAGED REFRIGERATION SYSTEMS Technical Guide

WCH5**4. Product Specifications

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Packaged Refrigeration Systems

Heat Recovery Unit Air Cooled Condenser for Precise Temperature & Humidity Control

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Advance Release September 2009

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

N4H4. Product Specifications

MAC-120HE-03 Air-Cooled Chiller

Air-Cooled Condensers

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Packaged refrigeration system Technical Guide

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Chillers A P P L I C AT I O N S

ThermoSaver TM Hot Gas Defrost System

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

PRODUCT SPECIFICATIONS

VertiCool Aurora Engineering Guide

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

R4H4. Product Specifications

C13-Series Engineering Guide

TECHNICAL SPECIFICATIONS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

ThermoSaver TM Hot Gas Defrost System

Industrial Unit Coolers

Specifications and Performance S2H

Liebert CSU3000 Chiller

High Profile Evaporator

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

SKYPAK II, 3 Ton Series, gives you a

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Copeland Scroll Outdoor Refrigeration Unit

Condensing Unit Installation and Operating Instructions

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Condensing Unit Installation and Operating Instructions

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

CoolSpot Engineering Guide

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

KTL Two-Way Low Profile Evaporators

VariCool VAV Engineering Guide

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

Energy Use in Refrigeration Systems

Indoor Air Handlers with Compressors MVS and MVW

Transcription:

LK-LTSCUTB BN-LTSCUTB OCTOBER OCTOBER 2017 2017 Air-Cooled Condensing Units with Screw s Technical Bulletin Low Temperature s SSV DSV

Table of Contents Nomenclature Chart... 2 Features and Benefits...3 Product Details...4-5 Performance Data... 6-11 Low Temperature... 6-11 4-9 R-404A... 6 R-507A... 7 R-407A... 8 R-407F... 9 R-448A...10 R-449A...11 Electrical Data...12 Unit Specifications...13 Dimensional Drawings...14 Nomenclature S S V O6OB L 6 D Number of Circuits Style Airflow Horsepower Temp. Range Refrigerant Type S = Single S = Screw V= Vertical 060B 60 L = Low 6 = R-404A D = 460/3/60 D = Dual 070B 70 R-507A E = 575/3/60 080B 80 100B - 100 120B - 120 140B - 140 R-407A R-407F R-448A R-449A Voltage 2

FEATURES & BENEFITS The Low Temperature Condensing Units with Screw s are designed to meet the needs of demanding commercial and industrial refrigeration applications, including Food Processing and Cold Storage Warehousing. The units are engineered to be flexible in custom design and constructed to meet the requirements of refrigeration contractors, consulting engineers and facility owners/ operators. Standard Features Cabinet & Construction Painted steel cabinet for superior strength and corrosion resistance Welded frame on all models for a robust and rigid product base All units feature the Floating Tube coil which eliminates tube sheet leaks Floating Tube coil design is featured on both oil-cooler and condenser Components (cont.) Motors Thermally protected, permanently lubricated ball bearing condenser and oil-cooler fan motors Controls System 450 controls provide reliable on/off controls and reduce installation time through a user-friendly interface which allows for ease of adjustment Serviceability Manual pumpdown switch on all units Convenient access panels to easily service internal components Replaceable core liquid-line filter Large electrical panels organized for maximum efficiency and to facilitate ease of access Components Low Temperature Screw s offer 50%, 75% and 100% steps of capacity. Resulting in an optimal cooling solution for large capacity applications of all types. s are rated for use with multiple refrigerants (R-404A, R-507A, R-407A, R-407F, R-448A & R-449A), allowing for flexibility Receivers are sized for sufficient pumpdown capacity of flood charges and include inlet and outlet service valves Optional Features Aluminum & Galvanized finishes available on condenser and oil-cooler. MCS Magnum Controller Variable-speed EC condenser fan motors Coated condenser coils for protection against corrosion in harsh environments VFDs circuit breaker Low ambient kit(s) with heated and insulated receiver Electric defrost kits including evaporator fan contactor(s) with fusing, defrost heater contactor(s) with fusing, and terminal strip. Oil Cooling All units are engineered with dedicated oil-coolers to match the requirements of your specific application Three-way mixing valve maintains oil return temperature. 3

PRODUCT DETAILS Electrical Box Features 4

Piping Details DRIER ISOLATION VALVES REPLACEABLE CORE LIQUID FILTER LIQUID LINE SIGHT GLASS LIQUID LINE BALL VALVE HEAD PRESSURE CONTROL VALVE DRAIN LINE CHECK VALVE LIQUID RECEIVER SUB COOLER BALL VALVE SUB COOLER LIQUID SOLENOID SUB COOLER SIGHT GLASS SUB COOLER TXV SUCTION ACCUMULATOR DISCHARGE MUFFLER MIXING VALVE ISOLATION OIL FILTER FLOW SWITCH ISOLATION VALVE MECHANICAL SUB COOLER BYPASS DIFFERENTIAL VALVE OIL SEPERATOR LIQUID SUPPLY BALL VALVE ISOLATION BALL VALVE DISCHARGE CHECK VALVE OIL MIXING VALVE COMPRESSOR SIGHT GLASS OIL INJECTION SOLENOID 5

PERFORMANCE DATA- LOW TEMPERATURE MODELS Low Temperature s R-404A Capacity BTUH @ 90 F Ambient by SST SSV060BL6* HSN7451-60 1 444,000 366,000 330,000 297,000 237,000 184,000 SSV070BL6* HSN7461-70 1 499,000 412,000 372,000 335,000 269,000 211,000 DSV080BL6* HSN6451-40 2 634,000 523,000 473,000 426,000 341,000 267,000 DSV100BL6* HSN6461-50 2 718,000 595,000 540,000 488,000 393,000 311,000 DSV120BL6* HSN7451-60 2 877,000 723,000 654,000 588,000 470,000 367,000 DSV140BL6* HSN7461-70 2 993,000 820,000 742,000 668,000 537,000 421,000 Capacity BTUH @ 95 F Ambient by SST SSV060BL6* HSN7451-60 1 432,000 355,000 322,000 289,000 230,000 180,000 SSV070BL6* HSN7461-70 1 486,000 400,000 362,000 326,000 262,000 206,000 DSV080BL6* HSN6451-40 2 620,000 512,000 463,000 417,000 334,000 261,000 DSV100BL6* HSN6461-50 2 699,000 581,000 527,000 476,000 384,000 304,000 DSV120BL6* HSN7451-60 2 850,000 702,000 635,000 572,000 458,000 358,000 DSV140BL6* HSN7461-70 2 966,000 798,000 723,000 651,000 523,000 412,000 Capacity BTUH @ 100 F Ambient by SST SSV060BL6* HSN7451-60 1 418,000 345,000 312,000 280,000 224,000 175,000 SSV070BL6* HSN7461-70 1 472,000 389,000 352,000 318,000 255,000 202,000 DSV080BL6* HSN6451-40 2 605,000 500,000 452,000 408,000 326,000 255,000 DSV100BL6* HSN6461-50 2 679,000 565,000 513,000 464,000 374,000 297,000 DSV120BL6* HSN7451-60 2 821,000 679,000 615,000 555,000 444,000 348,000 DSV140BL6* HSN7461-70 2 936,000 775,000 702,000 634,000 510,000 401,000 Contact Factory for Ambient Operations Higher than 100 F 6

PERFORMANCE DATA- LOW TEMPERATURE MODELS Low Temperature s R-507A Capacity BTUH @ 90 F Ambient by SST SSV060BL6* HSN7451-60 1 455,000 376,000 339,000 306,000 246,000 193,000 SSV070BL6* HSN7461-70 1 512,000 423,000 384,000 347,000 279,000 221,000 DSV080BL6* HSN6451-40 2 652,000 540,000 490,000 442,000 355,000 280,000 DSV100BL6* HSN6461-50 2 735,000 612,000 556,000 503,000 408,000 324,000 DSV120BL6* HSN7451-60 2 897,000 741,000 671,000 606,000 486,000 382,000 DSV140BL6* HSN7461-70 2 1,017,000 843,000 763,000 690,000 556,000 441,000 Capacity BTUH @ 95 F Ambient by SST SSV060BL6* HSN7451-60 1 441,000 365,000 330,000 298,000 239,000 188,000 SSV070BL6* HSN7461-70 1 496,000 412,000 372,000 336,000 273,000 215,000 DSV080BL6* HSN6451-40 2 579,000 528,000 478,000 432,000 348,000 275,000 DSV100BL6* HSN6461-50 2 714,000 595,000 541,000 491,000 398,000 317,000 DSV120BL6* HSN7451-60 2 867,000 718,000 651,000 588,000 474,000 373,000 DSV140BL6* HSN7461-70 2 987,000 819,000 742,000 671,000 542,000 430,000 Capacity BTUH @ 100 F Ambient by SST SSV060BL6* HSN7451-60 1 424,000 352,000 320,000 288,000 232,000 182,000 SSV070BL6* HSN7461-70 1 481,000 398,000 361,000 327,000 264,000 209,000 DSV080BL6* HSN6451-40 2 564,000 514,000 466,000 421,000 340,000 268,000 DSV100BL6* HSN6461-50 2 692,000 579,000 526,000 477,000 388,000 309,000 DSV120BL6* HSN7451-60 2 834,000 693,000 629,000 568,000 458,000 362,000 DSV140BL6* HSN7461-70 2 954,000 793,000 719,000 651,000 527,000 418,000 Contact Factory for Ambient Operations Higher than 100 F 7

PERFORMANCE DATA- LOW TEMPERATURE MODELS Low Temperature s R-407A Capacity BTUH @ 90 F Ambient by SST SSV060BL6* HSN7451-60 1 399,000 323,000 288,000 257,000 201,000 153,000 SSV070BL6* HSN7461-70 1 451,000 366,000 327,000 293,000 229,000 177,000 DSV080BL6* HSN6451-40 2 561,000 454,000 406,000 362,000 284,000 218,000 DSV100BL6* HSN6461-50 2 644,000 524,000 470,000 420,000 332,000 258,000 DSV120BL6* HSN7451-60 2 793,000 641,000 573,000 512,000 399,000 306,000 DSV140BL6* HSN7461-70 2 901,000 731,000 655,000 584,000 459,000 353,000 Capacity BTUH @ 95 F Ambient by SST SSV060BL6* HSN7451-60 1 393,000 316,000 283,000 252,000 197,000 150,000 SSV070BL6* HSN7461-70 1 444,000 360,000 323,000 287,000 226,000 173,000 DSV080BL6* HSN6451-40 2 554,000 448,000 401,000 357,000 279,000 214,000 DSV100BL6* HSN6461-50 2 634,000 516,000 463,000 414,000 326,000 252,000 DSV120BL6* HSN7451-60 2 777,000 628,000 562,000 501,000 392,000 299,000 DSV140BL6* HSN7461-70 2 887,000 719,000 644,000 574,000 451,000 347,000 Capacity BTUH @ 100 F Ambient by SST SSV060BL6* HSN7451-60 1 383,000 310,000 276,000 246,000 191,000 146,000 SSV070BL6* HSN7461-70 1 437,000 350,000 316,000 281,000 221,000 169,000 DSV080BL6* HSN6451-40 2 544,000 441,000 394,000 350,000 274,000 208,000 DSV100BL6* HSN6461-50 2 621,000 505,000 453,000 405,000 319,000 246,000 DSV120BL6* HSN7451-60 2 757,000 612,000 548,000 489,000 381,000 290,000 DSV140BL6* HSN7461-70 2 869,000 704,000 630,000 562,000 441,000 338,000 Contact Factory for Ambient Operations Higher than 100 F 8

PERFORMANCE DATA- LOW TEMPERATURE MODELS Low Temperature s R-407F Capacity BTUH @ 90 F Ambient by SST SSV060BL6* HSN7451-60 1 429,000 347,000 310,000 276,000 216,000 165,000 SSV070BL6* HSN7461-70 1 485,000 394,000 352,000 315,000 248,000 191,000 DSV080BL6* HSN6451-40 2 599,000 486,000 435,000 388,000 304,000 233,000 DSV100BL6* HSN6461-50 2 689,000 562,000 505,000 451,000 357,000 277,000 DSV120BL6* HSN7451-60 2 851,000 689,000 616,000 550,000 430,000 329,000 DSV140BL6* HSN7461-70 2 968,000 785,000 704,000 628,000 494,000 381,000 Capacity BTUH @ 95 F Ambient by SST SSV060BL6* HSN7451-60 1 421,000 341,000 304,000 272,000 212,000 162,000 SSV070BL6* HSN7461-70 1 478,000 388,000 348,000 310,000 243,000 187,000 DSV080BL6* HSN6451-40 2 592,000 480,000 429,000 382,000 300,000 229,000 DSV100BL6* HSN6461-50 2 679,000 553,000 497,000 444,000 350,000 272,000 DSV120BL6* HSN7451-60 2 834,000 676,000 605,000 539,000 421,000 323,000 DSV140BL6* HSN7461-70 2 952,000 773,000 692,000 618,000 486,000 373,000 Capacity BTUH @ 100 F Ambient by SST SSV060BL6* HSN7451-60 1 413,000 333,000 298,000 265,000 206,000 158,000 SSV070BL6* HSN7461-70 1 469,000 380,000 341,000 303,000 238,000 182,000 DSV080BL6* HSN6451-40 2 584,000 472,000 422,000 376,000 294,000 225,000 DSV100BL6* HSN6461-50 2 667,000 542,000 487,000 435,000 343,000 265,000 DSV120BL6* HSN7451-60 2 815,000 660,000 590,000 526,000 411,000 313,000 DSV140BL6* HSN7461-70 2 935,000 758,000 679,000 605,000 475,000 364,000 Contact Factory for Ambient Operations Higher than 100 F 9

PERFORMANCE DATA- LOW TEMPERATURE MODELS Low Temperature s R-448A Capacity BTUH @ 90 F Ambient by SST SSV060BL6* HSN7451-60 1 412,000 334,000 300,000 267,000 209,000 161,000 SSV070BL6* HSN7461-70 1 464,000 377,000 339,000 303,000 240,000 186,000 DSV080BL6* HSN6451-40 2 575,000 468,000 420,000 375,000 296,000 228,000 DSV100BL6* HSN6461-50 2 661,000 540,000 487,000 436,000 347,000 271,000 DSV120BL6* HSN7451-60 2 816,000 663,000 594,000 531,000 418,000 322,000 DSV140BL6* HSN7461-70 2 925,000 753,000 677,000 605,000 478,000 371,000 Capacity BTUH @ 95 F Ambient by SST SSV060BL6* HSN7451-60 1 404,000 328,000 294,000 262,000 205,000 158,000 SSV070BL6* HSN7461-70 1 457,000 372,000 334,000 299,000 236,000 183,000 DSV080BL6* HSN6451-40 2 568,000 462,000 415,000 371,000 292,000 226,000 DSV100BL6* HSN6461-50 2 652,000 533,000 479,000 430,000 341,000 266,000 DSV120BL6* HSN7451-60 2 800,000 650,000 583,000 520,000 410,000 315,000 DSV140BL6* HSN7461-70 2 911,000 742,000 666,000 596,000 470,000 365,000 Capacity BTUH @ 100 F Ambient by SST SSV060BL6* HSN7451-60 1 396,000 321,000 287,000 256,000 201,000 154,000 SSV070BL6* HSN7461-70 1 449,000 366,000 328,000 293,000 231,000 179,000 DSV080BL6* HSN6451-40 2 560,000 455,000 408,000 365,000 287,000 221,000 DSV100BL6* HSN6461-50 2 640,000 523,000 470,000 421,000 334,000 260,000 DSV120BL6* HSN7451-60 2 781,000 636,000 570,000 509,000 399,000 307,000 DSV140BL6* HSN7461-70 2 894,000 729,000 654,000 585,000 462,000 356,000 Contact Factory for Ambient Operations Higher than 100 F 10

PERFORMANCE DATA- LOW TEMPERATURE MODELS Low Temperature s R-449A Capacity BTUH @ 90 F Ambient by SST SSV060BL6* HSN7451-60 1 409,000 332,000 298,000 266,000 209,000 161,000 SSV070BL6* HSN7461-70 1 462,000 376,000 338,000 302,000 239,000 185,000 DSV080BL6* HSN6451-40 2 573,000 467,000 419,000 374,000 295,000 228,000 DSV100BL6* HSN6461-50 2 659,000 539,000 485,000 435,000 346,000 270,000 DSV120BL6* HSN7451-60 2 813,000 660,000 592,000 529,000 417,000 322,000 DSV140BL6* HSN7461-70 2 922,000 750,000 674,000 603,000 477,000 371,000 Capacity BTUH @ 95 F Ambient by SST SSV060BL6* HSN7451-60 1 402,000 326,000 293,000 261,000 205,000 158,000 SSV070BL6* HSN7461-70 1 455,000 371,000 332,000 298,000 235,000 182,000 DSV080BL6* HSN6451-40 2 566,000 461,000 414,000 370,000 291,000 225,000 DSV100BL6* HSN6461-50 2 649,000 531,000 478,000 428,000 340,000 266,000 DSV120BL6* HSN7451-60 2 798,000 649,000 582,000 519,000 409,000 315,000 DSV140BL6* HSN7461-70 2 906,000 739,000 663,000 593,000 469,000 364,000 Capacity BTUH @ 100 F Ambient by SST SSV060BL6* HSN7451-60 1 393,000 320,000 286,000 255,000 201,000 154,000 SSV070BL6* HSN7461-70 1 446,000 364,000 326,000 292,000 230,000 178,000 DSV080BL6* HSN6451-40 2 558,000 454,000 407,000 364,000 286,000 221,000 DSV100BL6* HSN6461-50 2 636,000 520,000 468,000 420,000 333,000 259,000 DSV120BL6* HSN7451-60 2 779,000 634,000 568,000 508,000 399,000 306,000 DSV140BL6* HSN7461-70 2 890,000 725,000 651,000 583,000 460,000 355,000 Contact Factory for Ambient Operations Higher than 100 F 11

ELECTRICAL DATA 460 Volts s Condenser Oil Cooler RLA LRA Fans FLA Fans Beacon or Air Defrost FLA MCA MOPD SSV060BL6D HSN7451-60 1 75.6 449 6 21 2 7 123 175 SSV070BL6D HSN7461-70 1 91.7 485 6 21 2 7 143 225 DSV080BL6D HSN6451-40 2 69.9 313 8 28 2 7 192 250 DSV100BL6D HSN6461-50 2 73.7 355 10 35 2 7 208 250 DSV120BL6D HSN7451-60 2 75.6 449 10 35 2 7 212 250 DSV140BL6D HSN7461-70 2 91.7 485 12 42 2 7 255 300 575 Volts s Condenser Oil Cooler RLA LRA Fans FLA Fans Beacon or Air Defrost FLA MCA MOPD SSV060BL6E HSN7451-60 1 60.3 322 6 16.8 2 5.6 98 150 SSV070BL6E HSN7461-70 1 73.1 404 6 16.8 2 5.6 114 175 DSV080BL6E HSN6451-40 2 55.8 222 8 22.4 2 5.6 154 200 DSV100BL6E HSN6461-50 2 59 281 10 28 2 5.6 166 200 DSV120BL6E HSN7451-60 2 60.3 322 10 28 2 5.6 169 200 DSV140BL6E HSN7461-70 2 73.1 404 12 33.6 2 5.6 204 250 12

UNIT SPECIFICATIONS Single Condenser Fan Data Fans Dia. Oil Cooler Fan Data Fans Connections (in.) Receiver (90 % Full) R-404A/R-507 R-407A/R-407F R-448A/R-449A Figure # Length A Dia. Liquid Suction Lbs. Kg. Lbs. Kg. Lbs. Kg. In. M SSV060BL6* HSN7451-60 6 30" 2 30" 1-3/8 3-1/8 232 105 249 113 258 117 1 314-1/4 8.0 SSV070BL6* HSN7461-70 6 30" 2 30" 1-3/8 3-1/8 338 153 362 164 375 170 1 314-1/4 8.0 Dual Condenser Fan Data Fans Dia. Oil Cooler Fan Data Fans Connections (in.) Receiver (90 % Full) R-404A/R-507 R-407A/R-407F R-448A/R-449A Figure # Length A Dia. Liquid Suction Lbs. Kg. Lbs. Kg. Lbs. Kg. In. M DSV080BL6* HSN6451-40 8 30" 2 30" 1-3/8 2-1/8 195 89 212 96 217 98 2 367-1/4 9.3 DSV100BL6* HSN6461-50 10 30" 2 30" 1-3/8 2-1/8 195 89 212 96 217 98 3 420-1/4 10.7 DSV120BL6* HSN7451-60 10 30" 2 30" 1-3/8 3-1/8 232 105 249 113 258 117 3 420-1/4 10.7 DSV140BL6* HSN7461-70 12 30" 2 30" 1-3/8 3-1/8 338 153 362 164 375 170 4 473-1/4 12.0 Unit Unit Oil Charging Requirements Numbers Oil Charge Required (Gallons) R-404A R-507A R-407A R-407F R-448A R-449A SSV060BL6* 8.0 8.0 8.0 8.0 8.0 8.0 SSV070BL6* 8.0 8.0 8.0 8.0 8.0 8.0 DSV080BL6* 10.5 10.5 8.0 8.0 8.0 8.0 DSV100BL6* 10.5 10.5 8.0 8.0 8.0 8.0 DSV120BL6* 10.5 10.5 10.5 10.5 10.5 10.5 DSV140BL6* 10.5 10.5 10.5 10.5 10.5 10.5 Units Oil-Cooler is designed based off of refrigerant selected at time of order Unit Weights Numbers Approx. Net Weight Lbs. Kg. SSV060BL6* 8,301 3,765 SSV070BL6* 8,438 3,827 DSV080BL6* 10,833 4,914 DSV100BL6* 11,568 5,247 DSV120BL6* 12,726 5,772 DSV140BL6* 14,035 6,366 13

UNIT SPECIFICATIONS Dimensional Drawings Figure. 1 81.21 15.64 13.21 87.50.00 35.00 3.00 130.00 176.00 259.00 102.67 113.77 313.00 A Figure. 2 81.21 87.50 20.00 14.50 3.00.00 35.00 130.00 176.00 211.00 312.00 101.83 107.76 111.83 118.13 366.00 A Figure. 3 81.21 87.50 20.00 14.50 3.00.00 35.00 130.00 176.00 264.00 365.00 101.83 107.76 111.86 118.13 419.00 A Figure. 4 81.21 87.50 20.00 14.50.00 35.00 3.00 130.00 176.00 317.00 418.00 99.82 107.76 111.83 118.10 472.00 A 14

NOTES 15

2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 heatcraftrpd.com Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice. LK-LTSCUTB October 2017 Version 001 2017 Heatcraft Refrigeration Products LLC