Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Similar documents
Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

HELKAMA. Optical Fibre Cables

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

Fiber Optic Distribution Cables (6-144 Fibers)

Duct Cable GYTS-144B1.3

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

DNVGL-CP-0402 Edition February 2016

Ø 1000 * 588 mm 50 kg

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

industry solutions: military

SPECIAL ELECTRICAL AND OPTICAL CABLES

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Fibre Specification Standards

Fiber Optic Patch Cord and Pigtails

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

STANDARD CONFORMANCE

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Fibre Optic Cable. Catalogue.

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

DNVGL-CP-0401 Edition February 2016

Product Specification CAT 6 UNSHIELDED PATCH CORDS

High Performance LSZH Fire Resistant Cable

PRODUCT CATALOGUE Norröna

FIRE RESISTANT CABLES

DNVGL-CP-0399 Edition March 2016

Special Provision No. 683S28 December 2017

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Traction Cable Radox 3 GKW

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

CATEGORY 6A FTP RJ45 SOLUTION

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

MT-RJ Optical Fiber System Field Testing

Fibre optic media options and trends

fire resistant cables

ENHANCED FIRE PERFORMANCE CABLE

Photovoltaic Cables EN H1Z2Z2-K

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Compact Module. Category 6A FTP Cabling System 1.1

TYPE APPROVAL CERTIFICATE

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Caledonian Flame Retardant Coaxial Cables

Cat 6 Shielded Patch cords

Caledonian Fire resistant Coaxial Cables

Multi-Core Fire Resistant Cable

Fire Safety Fire Resistant Building Components

Qualification Test Report LC Duplex Adapter For LC Cutouts

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Sensing Technology. A company of the BRUGG Group

Dome Fiber Optic Closure SC-221

Lloyd s Register Type Approval System Test Specification Number 3

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

ITU-T L.404. Field mountable single-mode optical fibre connectors

Üntel is ready for CPR

FIRE PERFORMANCE CABLE

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Cat 6 Unshielded Patch cords

OFS IV Optical Fibre System

Jan07 Rev B

INTERNATIONAL STANDARD

OPTICAL FIBER SOLUTIONS

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Basic Professional Fiber Optic Installation

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

/Oct/2014 Rev E

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

FIRST-CLASS IN TRAINS

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Single core cables with reduced wall thickness

Transcription:

Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber UV-resistant, metal-free, longitudinally waterproof, tensile strength and rodent repellent cable jacket: LSHF cable structure: filled loose tubes cable diameter for central loose tube 7.5 with 2 to 12 fibers per loose tube cable diameter for central loose tube 8.0 with 24 fibers per loose tube cable diameter with stranded loose tube 11.0 strain relief: longitudinally waterproof wrapping, glass roving elements stranded loose tubes: loose tubes grouped around a glass fiber reinforced plastic stick with a dia. of 2.5 for laying in ducts or directly in the ground in a suitable layer of sand applicable standards: EN 50173-1, ISO 11801 2nd edition, IEC 60794-1, EN 187000 fire behaviour: Class E ca Variant: Number of OM4 fibers Number of OM3 fibers Number of OM2 fibers 1x4, 1x8, 1x12, 1x24, 4x12 1x4, 1x8, 1x12, 1x24, 4x12 1x4, 1x8, 1x12 *The indication of fire protection classification is currently for

Illustrations Page 2/7 your General information Dataonly and becomes binding only after the assignment of the DoP number. Fields of application Design Transmission technology Color Color coding fiber/ wire(s) Mode type of the fiber Structured building cabling, Office Data center Installation cables Fiber optic blue see table Multimode Fiber class OM4 (ISO/IEC 11801/EN 50173 & IEC 60793-2-10/EN 60793-2-10 A1.a.3) Number of cables/ cores 1 Number of fibres each cable/ wire 24 Fiber construction 50/125 µm Weight 60.00 kg/km Connections/interfaces Connector technology interface 1 Connector technology interface 2 Cable sheath diameter (min. - max.) Cable sheath diameter Cable sheath diameter 8.00 0.315 in. Mechanical characteristics Strain relief Permanent tensile strength Short term tensile strength Maximum installation load (max.) Maximum installation load Maximum installation load Maximum operating bending radius Maximum operating bending radius Crush (compressive strength) Torsion resistance Fire load longitudinally waterproof wrapping, glass roving elements 700 N 1000 N 1500 N 100.00 3.937 in. 60.00 2.362 in. 2000 N 5 cycles ± 1 revolution 1300 MJ/km

Page 3/7 Materials and material properties Material - Cable jacket Bend insensitivity Tensile strength Rodent protection Flame retardancy Halogen free Metallfrei UV-resistance Longitudinal water tightness LSHF pass, no water on free end Environmental conditions Temperature (min. - max.) Temperature - Storage C -40-60 C Temperature - Storage F -40-140 F Temperature - Operating C -30-70 C Temperature - Operating F -22-158 F Temperature - Installation C -15-40 C Temperature - Installation F 5-104 F Approvals RoHS compliant The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801 Ed.2 DIN EN 50173-1 : 2002 Optical fibers: Generic specification General ISO/IEC 60794-1 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content IEC 60754-1 Determination of acidity (by measuring the ph value) IEC 60754-2 and conductivity Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated ISO/IEC 60332-1-2 wire or cable Measurement of smoke density of cables burning ISO/IEC 61034-2

Page 4/7 The product meets the following standards Coon test methods for cables under fire conditions Fire behaviour - class Class E ca * Classifications ETIM 5.0 ETIM 6.0 EC000034 EC000034 Packing details Type of packaging meter / drum

Fiber color coding Page 5/7 Fiber color code 1 red 13 yellow w/mark per 70 2 green 14 white w/mark per 70 3 blue 15 grey w/mark per 70 4 yellow 16 turquoise w/mark per 70 5 white 17 orange w/mark per 70 6 grey 18 pink w/mark per 70 7 brown 19 yellow w/mark every 35 8 violet 20 white w/mark every 35 9 turquoise 21 grey w/mark every 35 10 black 22 turquoise w/mark every 35 11 orange 23 orange with w/mark every 35 12 pink 24 pink w/mark every 35

OpDAT fiber OM4 BR Page 6/7 150XXX7 General Data Transmission technology Mode type of the fiber Fiber optic Multimode Fiber class OM4 (ISO/IEC 11801/EN 50173 & IEC 60793-2-10/EN 60793-2-10 A1.a.3) Fiber construction 50/125 µm Transmission characteristics Transmission rate up to 100 GBit Overfilled (OFL) modal bandwidth at 850 nm (min.) Overfilled (OFL) modal bandwidth at 1300 nm (min.) Effective modal bandwidth (EMB) at 850 nm (min.) IEEE 802.3ba 3500 MHz * km 500 MHz * km 4700 MHz * km Connections/interfaces Connector technology interface 1 Connector technology interface 2 Fasermanteldurchmesser 125.0 ± 1.0 µm Primary coating diameter - colored 242 ± 5 µm Primary coating diameter - uncolored 250 ± 15 µm Mechanical characteristics Proof stress level Strip force (peak) min. 0.7 ( 1 %) GPa Fiber cladding non-circularity max. 0.7 % Core non-circularity max. 5 % Core (MDF)-cladding concentricity error max. 1 µm Primary coating concentricity error max. 5 % Primary coating-cladding concentricity error max. 6 1.3 <= Fpeak.strip <= 8.9 N Inhomogeneity of OTDR measurement report at 1310 max. 0.1 db/km nm und 1550 nm Numerical aperture 0.200 ± 0.015 Materials and material properties Bend insensitivity

Powered by TCPDF (www.tcpdf.org) OpDAT fiber OM4 BR Page 7/7 150XXX7 The product meets the following standards Generic cabling systems General requirements ISO/IEC 11801 DIN EN 50173-1 TIA/EIA 568-C Data centers ISO/IEC 24764 Optical fibers: Measuring methods and test procedures Fibre geometry ISO/IEC 60793-1-20 Coating geometry ISO/IEC 60793-1-21 Length measurement ISO/IEC 60793-1-22 Fibre proof test ISO/IEC 60793-1-30 Coating strippability ISO/IEC 60793-1-32 Attenuation ISO/IEC 60793-1-40 Bandbreite ISO/IEC 60793-1-41 Numerical aperture ISO/IEC 60793-1-43 Gruppenlaufzeitdifferenz ISO/IEC 60793-1-49 Optical fibers: Product specifications Sectional specification for category A1 multimode fibres ITU-T standard TIA/ANSI-492 ISO/IEC 60793-2-10 (A1a.3) G.651.1 AAAD