NanoReady. Micro UV-Vis Spectrophotometer

Similar documents
SP-3800AA Atomic Absorption Spectrophotometer

detectors UltiMate 3000 Variable Wavelength Detectors

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

Prices valid until 31st December 2016

File No. 28(1192)/2017/Pur Date: 19/06/2018

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Variable Temperature Options for Optical Experiments

Nexera-i Specifications Prominence-i Specifications

Chemistry Instrumental Analysis Lecture 4. Chem 4631

Nicolet Evolution 300. UV-Visible Spectrophotometer

APPLIED. OMA-406R Rackmount Process Analyzer

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Specifications Wavelength Range: 190 nm to 800 nm continuous

OMA-300 Process Analyzer

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Mercury Vapor Monitor VM-3000

Who is GBC Scientific Equipment?

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

VM-3000 Mercury Vapor Monitor

Absorbance range Resolution Accuracy Type of microplate Wavelength Optic system Light source Wavelength accuracy. Calculation method

BENEFITS. QUATERNARY HPLC SYSTEMS Quaternary and Other Gradients. The Complete Range of HPLC. Convenience of Maintenance. Systems Configuration

PUV, PIR and PFO Series BROCHURE

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

QIAxpert Instrument Apps and Kit Compatibility

CS744 Series: Carbon/Sulfur by Combustion

Technical specifications of FT-IR Spectrometer

Variable Temperature Microprobe Systems

Model S FT-IR SPECTROMETER

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

PG 990 Atomic Absorption

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

VM-3000 Mercury Vapor Monitor

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Thermo Scientific Dionex UltiMate 3000 Fluorescence Detectors

Technical Information OUSAF44

AV6416 OTDR. Product Overview: Main Features:

VIEW500 FASTEST STANDARD OTDR

Equipment specifications (D6)

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

An FT-NIR Primer. NR800-A-006

UV Weather Resistance Test Chamber Technical Data

ELISA NIMBUS. Automated ELISA Processing System

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

FLX380-30x FlexTester OTDR

300 series HPLC autosamplers

MINI2 MOST ACCURATE COMPACT OTDR

VIEW500 USER-FRIENDLY STANDARD OTDR

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

ProStar 325 UV-Vis Detector

Development of a variable output LED-365 irradiance standard

Lighting Measurement Solutions

Atomic Absorption Spectrometer

SPECTRAL INSTRUMENTATION

Laser Particle Size Analyzer

Technical Information OUSAF12

73 Series Spectrophotometer. Accessory fitting and operation manual

BGA Rework Station Pro-660

Alpha Engineering Company

The latest development in material characterization and polymer processing. Rheometer Services Inc.

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

Technical Information OUSAF22

Agilent 1100 Series Variable Wavelength Detector. Reference Manual

- ibidi heating system - stage top incubator for life cell imaging

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

CLIMATRON GROWTH CABINETS

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Affordable Lab Technology

CALIBRATION HOW IT WORKS

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

S ATION EWORK ST BGA R

NYC STEM Summer Institute: Climate To Go! Infrared detection of carbon dioxide

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

How SWIR Imaging contributes to the optimization of automatic quality control in the food industry

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

FTS500 Series. Handheld OTDR Test Set.

Chapter 1. Introduction

The Viva-ProE System

DISSOLVED GAS ANALYZER (DGA)

WASTEWATER Online UV%Transmission Analyzer

2-wire Passive Intelligent Loop (LED) Display Meter

SHORT QUOTATION NOTICE TU/11 24/Pur/Qtn/2010/320 A, Dt. :25/4/11

CALIBRATION HOW IT WORKS

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Microscopy from Carl Zeiss

Digital Sensors Erythema Sensor PMA2101

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

BATHS SHAKERS STIRRERS HOTPLATES INCUBATORS HEATING MANTLES INCUBATORS

Technical Information OUSAF21

Modular Circular Polarimeters

PTWS 1220 USP/EP Tablet Dissolution Testing Instrument

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

Low-Frequency Raman Spectroscopy Enabling Affordable Access to the Terahertz Regime

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Transcription:

NanoReady Micro UV-Vis Spectrophotometer NanoReady Micro UV-Vis Spectrophotometer is a conventional laboratory equipment, not only widely used in molecular biological experiments such as DNA, RNA, protein detection, but also used in absorbance detection for the general substance analysis. It includes three common detections to the nucleic acids, nucleic acid markers and proteins. The variable path length of NanoReady realizes both the minimum sample volume detection as low as 0.5μL, suitable for precious samples, and the detection to the high concentration samples without dilution at all. Including the liquid drop, it builds in the standard cuvette detection module for more use. Features High sensitivity 2048 linear CCD detection unit, new-generation product of Hamamatsu, has higher sensitivity, accuracy as well as repeatability.

Stability for the long life Long-life xenon flash lamp of Hamamastu ensures stability of detection and the long life of instrument. The lifting detection base with sliding bearing structure has high precision, not easy to damage. Variable pathlength The minimum detection pathlength is 0.05mm; samples with high concentration can be detected directly without dilution. The maximum ~15000ng/μL dsdna, the smallest detection volume of precious samples is 0.5μL.The user-defined settings are allowed if the pathlength is more than 1mm.The instrument has flexible and convenient detection function. Ultra wide wavelength range With continuous wavelength range as 185-910nm, the instrument can detect various samples through selecting any band. It adapts to a variety of detection requirements with wide range of near infrared wavelength. Accurate pathlength The stepper motor combined unique double track technology (DPTL), allows the precision of optical pathlength as 0.001mm, thus to achieve highly repeatability of absorbance detection.

Cuvette detection modecuvette detection mode The cuvette detection mode comes with magnetic stirring function. User can set the heating function and stirring speed for dynamic analysis detection. And the user can define different pathlength, such as 1mm, 2mm, 5mm,10mm(for Model: FC-1100 only). Unique designed pipette holder for easy sample adding Auxiliary holder for adding liquid can ensure the accuracy of adding liquid during micro measurement. It is also suitable for other mainstream brands of micro UV-Vis Spectrophotometer in the market to achieve a stable and simple process of adding liquid.

User-friendly software The simple designed interface makes the software user friendly. It will save the detection data and name file automatically, and it is easy to review the files. There is no need to worry about the loss of experimental data. Set U disk upgrade interface, and maintain the latest and most complete function at any time. Wireless connection WiFi connected PAD to control the detection and results display and storage without need the cables. Dynamic detection realizes remote controlling and timing reading the results without manual intervention. Multi-functions Nucleic acid detection Built-in common calculation formula of dsdna, ssdna, RNA, Oligo-DNA, Oligo-RNA, can get the concentration and purity of samples automatically. UV visible custom scanning In the full wavelength range, set the detected wavelength through increasing or decreasing wavelength with 1 nm as expected. Nucleic acid fluorescence marker detection Preinstall extinction factor of commonly used fluorescent dyes of dsdna, ssdna, RNA, Oligo-DNA, Oligo-RNA. Protein detection Can detect the concentration of protein solution, or detect protein concentration of dye marker, with built-in common detection methods of BCA, Bradford, Lowry, and Pierce 660nm. Nucleic acid fluorescence marker detection Preinstall extinction factor of commonly used fluorescent dyes of dsdna, ssdna, RNA, Oligo-DNA, and Oligo-RNA. Cell detection

Can detect absorbance value at 600nm automatically. Meanwhile, it can detect absorbance value at any band under set wavelength range. Specifications Detector Parameters FC-1100 F-1100 2048-element liner CCD array Mini. Sample Amount (μl) 0.5 Mini. Path length (mm) 0.05 Wavelength Range (nm) 185-910 Wavelength Accuracy (nm) ±1 Spectral Resolution (nm) Absorbance Accuracy 1.8(FWHMat Hg 253.7nm) 0.002 (1mm optical length) Absorption Accuracy Limit of Detection Max. Detection Concentration Detection Time 3%(at.74A at 350nm) 2ng/μl dsdna 15000ng/μl dsdna <5 Sec. Heating Temp.( ) 37±0.5 null Mixing Speed (RPM) 150-850 null Cuvette Mode Optical Length (mm) 10,5,2,1 null Limit of Detection 0.4ng/μl dsdna null Max.Detection 750ng/μl dsdna null Concentration Data Interface USB Wireless Connection Wifi Software Update USB direct update Accessory Pipette holder Power AC110V-220V 50HZ/60HZ (Power adapter) NET Weight: 2.1KG 2.0KG D.S Scientific Solutions Pvt Ltd, 808, 8th Floor, Ansal's Vikas Deep Building,Laxmi Nagar District Centre, New Delhi - 110092 (India) Ph. / Fax : +91-11-45741122 website : www.dsstechno.com