CR103-RG57A3. REMOTE CONTROLLER ILLUSTRATION (Function selection)

Similar documents
REMOTE CONTROLLER RG57

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner.

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR137-RG51F

CONTENTS ,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons...

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

REMOTE CONTROLLER KSWM units

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

Remote Control Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

SYSCONTROL RM 52. SYSPLIT Type Remote controller user manual CR090 RG52A A

,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons Auto operation...

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

USER MANUAL MIDEA FAIRWIND

DVC/DVH 09/12/18/24 Series

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM. Quick-Start Guide ON/OFF TEMP MODE SILENCE FP FAN SPEED SWING TIMER ON SWING TIMER OFF SLEEP

CR034-RG36F

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR004-RG35/

SPLIT-TYPE ROOM AIR CONDITIONER

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

REMOTE CONTROL MANUAL

REMOTE CONTROLLER CR057-RG51Q&J MANUAL

Remote Control User Manual

SERIES AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

AIR CONDITIONER REMOTE CONTROLLER MANUAL

A IR CONDITIONE R REMOTE CONTROLLER ILLUSTRATION CR087-RG05F2EU

SET TEMPERATURE( F) AUTO COOL DRY HEAT TEMP MODE SWING RESET LOCK LED DISPLAY

Remote Control Instructions

CR193-RG70E2(2)BGEU

Remote Control Features & Functions. (78) Symphony Solo Series Remote Control USERS GUIDE

Remote Control Operation Manual Split Type Air Conditioner

Remote Controller Manual

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR054-RG51B

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Portable Room Air Conditioner Remote Control for:

CR166-RG57A6EU- 6 INFRARED WIRELESS MULTI FUNCTION REMOTE CONTROLLER OWNER S MANUAL

Slim Line Ceiling Concealed Ducted Split Systems

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Owner's Manual TABLE OF CONTENTS

REMOTE CONTROLLER OWNER S MANUAL

KSIM UNITS. User s Manual

BTU Units WORKING PROGRAM MANUAL

Operating Functions Temperature Parameters

DuctlessAire ES Series. Service Manual 2016 ABSSA-B4-1601

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Owner s Manual TABLE OF CONTENTS

OWNER S & INSTRUCTION MANUAL

High Wall Split Air Conditioners 53QHCT KHCT

2. Pictographs 2.1 Basic Operation

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Hi Wall Split Air Conditioners

53 KNL / 53 QNL OWNER S MANUAL

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

CONTENTS. When using this air conditioner in the European countries, please read the following information:

HABITAT USER MANUAL TIN310**V33 TIN414**V33 TIN520**V33 TIN625**V33 TIN1036H2V02 TIN1939H2V02 INVERTER MINI SPLIT

Buttons on remote controller

Using the Remote Control Unit

Owner's Manual TABLE OF CONTENTS

Portable Air-conditioner Use and Care Manual

SERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type

Wired Controller XK60

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Remote Controller. <Open the front cover> <ARC452A4>

AUTO COOL DRY HEAT FAN SPEED TURBO HIGH MID LOW AUTO. SLEEP iclean HEALTH ifavor Eheater Anti-FUNGUS DISPLAY LOCK. TURBO TIMER ifavor

Owner s Manual TABLE OF CONTENTS

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Owner s Manual Super-Slim Four-Way Cassette

WORKING PROGRAM. Heating dehumidifying cooling T 27

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Operating Instructions

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

Table of Contents. Page. 1. Safety Precautions Specifications Product Features Maintenance and Disassembly...

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

Owner s Manual TABLE OF CONTENTS

Portable Air-conditioner

KSD-35 DR11 KUE-35 DVN11

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

AIR-CONDITIONER REMOTE CONTROLLER INSTRUCTIONS

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

REMOTE CONTROL MANUAL

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

15C Inverter Series. Service Manual

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

INVERTER SPLIT TYPE - ROOM AIR CONDITIONER

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

OWNER S MANUAL ENGLISH REMOTE CONTROLLER R05 YDS-R

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Inverter Air Conditioner User Manual KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH

USER MANUAL NEXXOS INVERTER MINI SPLIT NIN413C2V33 NIN720C2V33 NIN728C2V33

Service Manual CAUTION ! WARNING INTRODUCTION. 619PB High Wall Ductless System Sizes 09 to 36

Owner s Manual TABLE OF CONTENTS

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL

Transcription:

REMTE CNTRLLER ILLUSTRATIN (Function selection) The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. CR103-RG57A3 Thank you very much for purchasing our products. Please read this manual carefully before using the remote controller.

ADJUST CNFIRM CNTENTS Handling the remote controller... 1 Remote controller specification... 2 Handling the remote controller 8m Location of the remote controller. Keep the remote controller where its signals can reach the receiver of the indoor unit. (a distance of 8m is allowed). Features of remote controller buttons... 2 MDIFY PWER FF How to set up the funcitons... 4 CAUTINS The air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit. Prevent any liquid from falling into the remote controller. Do not expose the remote controller to direct sunlight or heat. If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver. If other electrical appliances react to the remote controller, either move these appliances or consult your local dealer. Replacing batteries The remote controller uses two alkaline dry batteries (R03/LR03X2) (1) Slide the cover of the battery compartment off according to the arrow direction, then replace the old batteries with new ones. (2) Insert the new batteries, making sure that the(+) and (-) of battery are installed correctly. (3) Reattach the cover by sliding it back into position. NTE: Do not mix old and new batteries or batteries of different types. Do not leave the batteries in the remote controller if they are not going to be used for 2 or 3 months. Do not dispose batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. 1

Remote Controller Specification Model Rated Voltage Signal Receiving Range Environment RG57A3/BGEF 3.0V(Dry batteries R03/LR03 2) 8m -5 C 60 C ~ IMPRTANT: The remote controller is only enabled within10 minutes after the indoor unit is powered on, and the indoor unit must be switched off. N/FF PWER FF button: Press this button to turn off the unit Features of Remote Controller buttons NTE: After installing the batteries, during the first 30 seconds period, please holding down the, FAN and TIME N buttons together for 5 seconds, the remote controller will enter function reset state, and LCD window displays F1. button: Used to modify the selected function. Press this button to enter the parameter setting interface, and the parameter to be modified will be kept flashing. Using & button to modify the parameter or choosing the other parameter in conjuction with FAN & TIMER FF button. & button: Used to choose functions or adjust parameters. n parameter unadjustable interface, press the & button to select the specified function in a range of F1 ~ F9 and E1~E9. Then pressing the button to enter the parameter modifying interface, the relevant parameter flashes, pressing & button to adjust the paramter. N/FF FAN SLEEP FRESH TURB SELF CLEAN SHRT CUT TIMER N TIMER FF LED FLLW ME FAN TIMER FF button:press this button to confirm the setting parameter and transmit the singal to the machine. FAN & TIMER FF button: n parameter setting interface, pressing FAN & TIMER FF button to select parameter to be modified. SLEEP FRESH LCK button: Hold and press this two buttons for 2 seconds, all current settings of indoor unit are locked in and the remote controller does not accept any operation except that of the LCK. 2 3

How to set up the functions NTE: The indoor unit will beep for 2 seconds indicating the function being set up successfully. Auto-start function 1. Press & button to choose F1. 2. Press button. Then press & button to choose n or ff. 3. Press button, and the Auto-start function on/off setting has finished. 3. Press button. Anti-cold air function Intelligent anti-cold air function setting: NTE: The parameter of intelligent anti-cold air is changed with the room temperature. After the room temperature raised, the temperature of anti-cold air would raise too, which can make you feel more comfortable. After the room temperature decreased, the anti-cold air temperature would decrease too, which can improve the fan speed and bring fast heating operation. 1. Press & button to choose F3. Heating temperature compensation 1. Press & button to choose F2. 2. Press button. Press FAN button to to choose parameter. Then press & button to select 1. FAN 2. Press button. Then press & button to choose the parameter. The parameters can be adjusted within a range of -6 C~6 C. Flashing 3.Press TIMER FF button to adjust the parameter. The parameter keeps flashing. Then press & button to adjust the parameter in the range of 17 C~21 C. TIMER FF Flashing ADJUST - - -............ - - - 4. Press button to confirm. 4 5

General Anti-cold air function setting: NTE: The parameter of general anti-cold air is fixed regardless of room temperature. 1. Press & button to choose F3. Speed control of indoor fan motor after the set temperature reached 1. Press & button to choose F4. 2. Press button. Press FAN button to to choose parameter. Then press & button to select 2. 2. Press button. Then press & button to select 1, 2, 3 or 4. FAN Flashing 3.Press TIMER FF button to adjust the parameter. The parameter keeps flashing. Then press & button to adjust the parameter in the range of 8 C~28 C. Indicates stopping fan motor Indicates operating at lowest fan speed TIMER FF Indicates operating at setting fan speed Flashing 4. Press button to confirm. Indicates Termal function 3. Press button. 6 7

Louver angle memory function 1. Press & button to choose F5. Heating only or Cooling & heating setting 1. Press & button to choose F6. 2. Press button. Then press & button to select 1, 2 or 3. 2. Press button. Then press & button to select HH or CH. (HH: Heating only, CH: Cooling & Heating) 3. Press button to confirm. Cooling temperature compensation Indicates cancelling memory function. Indicates the louver angle memory function is enabled under switching off or power failure. Indicates the louver angle memory function is enabled under switching off, disabled under power failure. 3. Press button to confirm. 1. Press & button to choose F7. 2. Press button. Then press & button to choose the parameter in a range of -2 C~2 C. 3. Press button to confirm. Refrigerant leakage detection 1. Press & button to choose F8. 2. Press button. Then press & button to choose on or of. 3. Press button to confirm. 8 9

Cleaning Filter Reminder 1. Press & button to choose F9. High temperature setting 1. Press & button to choose E3. 2. Press button. Then press & button to choose on or of. 3. Press button to confirm. 2. Press button. Then press & button to set the temperature in a range of 25 C to 30 C. 3. Press button to confirm. Filter Replacement Reminder Special Anti-cold air function setting: 1. Press & button to choose E1. 1. Press & button to choose E4. 2. Press button. Then press & button to 2. Press button. Then press & button to choose on or of. choose on or of. 3. Press button to confirm. 3. Press button to confirm. Lowest temperature setting 1. Press & button to choose E2. Priority setting of heating or cooling (applicable for multi models) 1. Press & button to choose E5. : Heating mode first : cooling mode first 2. Press button. Then press & button to set the temperature in a range of 17 C to 24 C. 3. Press button to confirm. 2. Press button. Then press & button to choose H or C. 3. Press button to confirm. 10 11

Network Address setting 1. Press & button to choose E6. Twins setting 1. Press & button to choose E8. 2. Press button. Then press & button to choose the network address between 0 to 63 or. -- -- Indicates cancelling the the adress modified by remote controller (determined by code switch). 3. Press button to confirm. 2. Press button. Then press & button to choose 0(no twins), 1(main unit) or 2(subsidiary unit) 3. Press button to confirm. Static pressure setting Capacity code selection 1. Press & button to choose E7. 1. Press & button to choose E9. 2. Press button. Then press & button to choose the capacity code between 0~11. (0~3: d number), 4: 18K model, 5: 24K model, 2. Press button. Then press & button to choose the value between 0 and 4. 3. Press button to confirm. 7: 30K model, 8: 35K model, 9: 48K model, 10: 54K model 11: 60K model. 3. Press button to confirm. NTES Some functions of the remote controller will not be available when the unit does not support them! 12 13

Point check function Press the LED DISPLAY button( Mute button for some remote controllers) of remote controller three times and then press AIR DIRECTIN button ( Swing button for some remote controllers) three times within 10 seconds, the buzzer ring last 2 seconds,the air conditioner will enter the information enquiry status. After that, press the LED DISPLAY button to enquiry the next one information and press the AIR DIRECTIN button to enquiry the last one information. When the air conditioner enter the information enquiry status, it will display the code name in 2 seconds, the details are as follows: Enquiry information Displaying code T1 T1 T1 temp. T2 T2 T2 temp. T3 T3 T3 temp. T4 T2B TP TH Targeted Frequency Actual Frequency Indoor fan speed utdoor fan speed EXV opening angle Compressor continuous running time Causes of compressor stop T4 Tb TP TH FT Fr IF F LA CT ST A0 A1 b0 b1 b2 b3 b4 b5 b6 dl Ac Uo Td T4 temp. Meaning T2B temp. TP temp. TH temp. Targeted Frequency Actual Frequency Indoor fan speed utdoor fan speed EXV opening angle Compressor continuous running time Causes of compressor stop When the air condtioner enter the information enquiry status, it will display the code value in the next 25s after display name is displayed, the details are as follows, Enquiry information T1,T2,T3, T4,T2B,TP, TH, Targeted Frequency, Actual Frequency Indoor fan speed/ utdoor fan speed EXV opening angle Compressor continuous running time Causes of compressor stop. Display value -1F,-1E, -1d,-1c, -1b,-1A -19-99 0 1,2,3,4 14-FF 0-99 Meaning -25,-24,-23,-22, -21,-20-19-99 A0,A1...A9 100,101...109 b0,b1...b9 110,111...119 c0,c1...c9 120,121...129 d0,d1...d9 130,131...139 E0,E1...E9 140,141...149 F0,F1...F9 150,151...159 FF Low speed, Medium speed, High speed, Turbo Actual fan speed =Display value turns to decimal value and then multiply 10. The unit is RPM. Actual EXV opening value= Display value turns to decimal value and then multiply 2. Remark 1. All the displaying temperature is actual value. 2. All the temperature is C no matter what kind of remote controller is used. 3. T1,T2,T3,T4,T2B display range:-25~70, TP display range:-20~130. 4. Frequency display range: 0~159HZ. 5. If the actual value exceeds the range, it will display the maximum value or minimum value. For some big capacity motors. For some small capacity motors, display value is from 14-FF(hexadecimal), the corresponding fan speed range is from 200-2550RPM. 0-255 minutes If the actual value exceeds the range, it will display the maximum value or minimum value. For the detailed Decimal display meaning, please consult with engineer 14 15