Simple On The Outside...

Similar documents
Simple On The Outside...

Worldwide Contacts.

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Deluge & Preac tion Systems

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Tyco Fire Valves Pure Performance

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

ADDITIONAL PRODUCTS 65

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Fire Protection Products Technical Data Book Table of Contents, August 2017

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

A. This section includes design and performance information for fire protection and suppression systems.

TotalPac 3 Firecyle III Deluge Remote controlled system

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

TotalPac 3 Wet pipe system c/w retard chamber

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

Tyco Fire & Building Products is available worldwide under the leading brand names: CENTRAL, GEM, STAR, and GRINNELL.

TotalPac X Single interlock SUREFIRE system

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

TotalPac X Firecycle III Preaction Double interlock system

AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

Sprinkler Inspection Certificate

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

as required for residential sprinklers intended for use in dry pipe systems.

Instructions for Installation, Operation, Care and Maintenance

PHYSICAL FACILITIES. 1 General. 2 Related Requirements. 5 Quality Assurance. 3 Wiring. 4 Submittals

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

DIVISION 21 - FIRE SUPPRESSION

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

DIVISION 21 - FIRE SUPPRESSION

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

Sprinkler Solutions for Storage Applications

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

Residential Fire Protection Sprinklers & Systems

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

WET-PIPE SPRINKLER SYSTEMS

Gas Station & C Store SECTION CWM Job No

Care and Maintenance

AESTHETIC SPRINKLERS.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

Connected: Global protection, all together

SPRINKLERS TABLE OF CONTENTS

VSR-M REPLACEMENT Waterflow Switch for Globe Sprinkler Model UMC Manifold

2. Welding Materials and Procedures shall conform to the ASME Code.

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D40 FIRE PROTECTION 02/18

Rapidrop Global Ltd. Product Range. British Manufacturer and Supplier of Fire Sprinkler and Fire Suppression Equipment.

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

FireFlex DUAL Double Interlock, Self-contained system

TECHNICAL DATA OBSOLETE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

SECTION PREACTION SPRINKLER SYSTEMS

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

TOTALPAC2 Integrated Fire Protection System

B. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

TotalPac 3 Deluge, Electric release Self-contained system

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

North Hanover Township School District North Hanover Township, New Jersey

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

SECTION AUTOMATIC SPRINKLER PIPING

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Environmental Health & Safety

Design & Construction Standards, Revised January

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

ALEWIJNSE INTERNATIONAL SWITCHBOARD PRODUCTION

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Effective Date 3/13/2007 With Addendums thru 12/5/2007

OPEN SPRINKLER SYSTEM

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

TECHNICAL DATA. 319a. January 27, 2012

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

Transcription:

Safer. Smarter. Tyco. Simple On The Outside...

...Effective On The Inside Tyco Fire Protection Products is the leading manufacturer and distributor of water-based fire suppression systems and components, offering one of the broadest lines of fire protection system equipment worldwide. Continually expanding its capabilities through proactive research and product development, it providers its customers with effective fire protection and construction solutions for residential, commercial, industrial and institutional buildings. We supply a wide range of sprinklers, alarm valves and accessories as well as CPVC pipe & fittings, flowmeters, general purpose valves, hydrants, couplings and grooved fittings, sprinkler support materials, foam products and hardware. Tyco has branches strategically located throughout Europe and the Middle East to provide customers with the best possible service.

The Cabinets What makes it special? Easy to Install // Entire package is pre-wired // Water inlet and outlets to the valve riser are grooved to ensure minimal installation time // Completely pre-trimmed valve inside // Easy to move lift point eye bolts // Tested and fully functional Weather Proof // Available with optional heated housing // Applicable for indoor OR outdoor use // Comes complete with water resistant seal to project the entire contents of the cabinet Pre-tested // Tyco s cabinet system provides you with one complete solution with no need for any additional testing. The valves and components are all pre-tested by our Tyco engineers European Made // Uses the famous DV-5 which is produced in Spain // Designed, engineered and built at our Centre of Excellence for valve engineering in the Netherlands The TYCO DV-5 Red-E Cabinet, is a pre-assembled fire protection valve package enclosed within a free-standing cabinet designed to occupy minimal floor space and provide an enclosure for a fire protection valve riser. The packaged DV-5 Red-E Cabinet is pre-wired and the water inlet and outlets to the valve riser are grooved. The valve package includes the system (manual) shut-off control valve, a downstream shut-off valve, an automatic water control valve with electric actuation with galvanized trim and supervisory switches.

Options: Deluge Wet Deluge Dry Deluge Electric Heater 4 4 4 Light and socket plug 230VAC 4 4 4 Water motor alarm WMA-1 4 4 4 Low temperature switch 4 4 4 Manual pull station accessible from the outside 4 4 4 Without downstream butterfly valve 4 4 4 Cabinet colour grey RAL7035 4 4 4 Potter Release Panel 4 4 4 Handbook 4 4 4 Factory acceptance test 4 4 4 Split flanges (adapter grooved to flanged) 4 4 4 Always refer to the Technical Data Sheet TFP1303 for complete description of all listing criteria, design parameters, installation instructions, care and maintenance guidelines, and our limited warranty. LIFT POINT EYE BOLTS WATERFLOW PRESSURE ALARM SWITCH DRAIN DRAIN HEADER (CONNECTION EITHER SIDE OF CABINET) OPTIONAL RELEASING PANEL WITH LOCKING DOOR WATER SUPPLY HEADER (CONNECTION EITHER SIDE OF CABINET) CABINET (LOCKING DOORS NOT SHOWN) PRESSURE GAUGES DV-5 WITH ELECTRIC ACTUATION DELUGE TRIM DISCHARGE CONNECTION SOLENOID MANUAL STATION LEFT SIDE FRONT

How The Valve Functions All switches within the cabinet are pre-wired to a junction box. An optional control panel is available and is pre-wired. The control panel can be used to make the electrical connections for power, detection circuits, and alarms, the only remaining connections to complete the system. In addition to the optional control panel being integral to the DV-5 Red-E Cabinet, windows have been pro vided in the door for viewing the essential system pressure gauges. Locks for the cabinet door and the control panel access are standard. The outdoor version of the DV-5 Red-E Cabinet, Middle East have sealed doors and connections to the elements. Optimized Production Process Detailed Engineering Standard Cabinets Customer Sign off Standard Cabinets + options Special Cabinets Time scale By making use of optimized process Tyco is able to offer standardized cabinets and standardized cabinets with certain range of specific options. For these cabinets Detailed Engineering and Customer Sign Off can be done at the same time. This is enabled by an already prepared Detailed Engineering, availability of a Datasheet (TFP1303) and a quick quoting process. For Special Cabinets Tyco will follow the Detailed Engineering and Customer Sign Off as two separate steps. First the Detailed Engineering will be completed based on a discussion with the customer concerning his needs. Customer feedback on our designs is essential to ensure the exact needs of our customers are fulfilled. Based on this feedback and input from the customer, a quotation will be produced. We will only begin production when the customer is completely happy with the design and features of the cabinet.