SERIES 47K GAS SENSOR

Similar documents
Operation Manual Series 47K Gas Detector [SIL 2]

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

VQ500 Series Combustible Gas Detector Elements

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Dräger Polytron SE Ex Fixed Gas Detector

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Operation Manual Series 47K Gas Detector [SIL 2]

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

IT S WHAT S INSIDE THAT

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

VQ600 Series Combustible Gas Sensing Head

Dräger PIR 3000 Detection of flammable gases and vapours

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Lamp Supply (Recommended)

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8200 Stationary gas detector (CatEx)

SAFETY MANUAL. UltraSonic IS-5 Ultrasonic Gas Leak Detector

SIMRAD GD10PE IR GAS DETECTOR

MICROpeL 75 Combustible Gas Sensor Part Number: PM

THE BELGIAN PIONEER IN GAS DETECTION

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

OPTIBAR DP 7060 Supplementary Instructions

Danfoss gas detection unit Type GD Heavy Duty

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

3M Oldham OLCT 100. Description. Fixed Gas Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

P R O D U C T D ATA S H E E T

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

Dräger Polytron 8310 Stationary gas detector (DSIR)

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

gas monitoring system

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SIMRAD GD10 IR GAS DETECTOR

SIL 2. Ultima X Series Gas Monitors CERTIFIED

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

IR15 Dual Gas Series Datasheet

Zareba Sensepoint Pro

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Dräger Polytron 8000 Stationary gas detector (EC)

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

PrimaX Gas Transmitter Versatile Gas Detection to Meet Your Needs

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ULTIMA X5000. MSAX5000.com

Transmitters/Sensors. OLCT Series

MODEL 9010/9020 LCD CONTROL UNIT

THE BELGIAN PIONEER IN GAS DETECTION

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Guide to Explosion Protection and Plant Safety

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Dräger PIR 7200 Toxic Gas Detection Transmitter

MSA XCell Sensors. Because every life has a purpose

Explosion-proof Immersion Heater Type D-8660

Fixed Gas & Flame Detection International Product Range Overview

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

URD20SE. Gas detectors Carbon dioxide (CO 2 ) ATEX certified (II 2G Ex d IIC T6) Use. Operation. Ordering

Dräger PEX 3000 Flammable Gas Detection

Technical data sheet TDS0060

IR25 Dual Gas Series Datasheet

SAFETY MANUAL. FlameGard 5 MSIR Multi-Spectral Infrared Flame Detectors

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

IT S WHAT S INSIDE THAT COUNTS

portable gas analyser

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

IR1 Single Gas Series Datasheet

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

IT S WHAT S INSIDE THAT COUNTS

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Sensor unit MC2 with analog output for Freon gases and refrigerants

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

LGCNCOE Study Guide: Fixed Gas Detection

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Transcription:

Data Sheet SERIES 47K GAS SENSOR Remote Combustible Gas Detection Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com

Series 47K Gas Sensor Remote Combustible Gas Detection MSA remote sensors, Series 47K, are designed to detect potentially hazardous concentrations of flammable gas and vapour in air. A complete range of accessories for calibration, environmental protection, sampling and duct mounting makes it suitable for virtually all applications in combustible gas detection. A cost effective range of sensors for detecting up to 100% LEL including Poison Resistant, Standard and High Temperature versions. Series 47K sensors used in combination with MSA Controllers fully meet the requirements of ATEX Directive 94/9/EC, including performance, and being SIL 2 capable they can be used as part of a safety related system. Series 47K sensors are available with either Ex d 3/4 NPT or Ex e M25 junction boxes.

Broad range of sensors Features & Benefits 0 100% LEL Ex e junction box with M25 cable gland thread Ex d junction box with 3/4 NPT cable gland thread Standard (ST), Poison Resistant (PRP) and High Temperature (HT) versions Suitable for use in safety related systems (ATEX 94/9/EC) 3 or 5 wire connection Stainless steel body Complete range of accessories Fast response time Excellent performance cost ratio Safety Integrity Level SIL 2 Sensor Types MSA sensors are available as standard in a stainless steel body. Series 47K-PRP: high resistance to atmospheres containing silicones, lead, sulphur compounds and halogenated hydrocarbons over a temperature range 40 C to +90 C Series 47K-ST: for general purpose applications over the ambient temperature range 40 C to +90 C Series 47K-HT: to operate over a temperature range 40 C to +160 C Installation & Operation The number and location of sensors is important to achieve the most reliable detection of flammable gas or vapour. There are several factors to be considered before installing the sensor. (See also EN 60079-29-2 Guide for selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen ) Location of potential sources of a gas leak Location of potential sources of ignition Ventilation and airflow patterns The gas or vapour density with respect to air The physical properties of the gas or vapour Structural arrangements which could allow gas to accumulate Environmental conditions 2 Applications Chemical & Petrochemical Industry Printing Industry Pipelines Gas Industry Refrigeration Industry LPG Storage and Transportation Shipboard Paint Manufacture Solvent Recovery & Storage Loading-Unloading of Hazardous Gas & Vapour Automotive Test Benches Boiler Rooms Turbine & Compressors Biofuels

and accessories Accessories There are applications where the sensors cannot be installed close to the potential source of a gas or vapour leak. This may be due to extremely high temperature, higher or lower atmospheric pressure, difficult to access locations, high flow-rate of air to be monitored or the presence of dust. For these applications, MSA offers a variety of accessories such as flowthrough adaptors or duct mount flanges, which allow reliable, trouble-free detection with minimum maintenance. Additional accessories are available for environmen tal protection and a remote/in-situ calibration kit for ease of maintenance. 47 K 3/4 NPT Measuring Principle The MSA 47K Series of sensors operate on the principle of cata lytic combustion. The sensing element consists of a pair of filaments ( pellistors ) connected to a pair of precision resistors to form a Wheatstone bridge. One of the filaments, the detector, is coated with a catalyst, whilst the other, the compensator is used as a reference to achieve the best stability. The gas or vapour diffuses through a porous Stainless Steel sintered disc, which acts as a flashback arrestor. When gas comes into contact with the surface of the detector filament, it is oxidised. The heat generated by the reaction increases the temperature of the detector, which results in a change of the detector electrical resistance, and hence an unbalance of the Wheatstone bridge. The result is an output signal directly proportional to the concentration of the flammable gas or vapour. Detector 47 K M25 x 1.5 Compensator The Series 47K sensors are performance approved according to EN 60079-29-1 when operated in conjunction with an MSA type approved Controller. They can therefore be used as safety related devices meeting the requirements of ATEX Directive 94/9/EC. The sensors are ATEX approved according to new standards EN 60079-0, EN 60079-1, EN 61241-0, EN 61241-1 for use with or without an Ex d or Ex e certified juncion box. Series 47K sensors are also certified SIL 2 capable by TUV. EC Type Certificate: INERIS 03ATEX 0208 II 2G Ex d IIC T6 40 C +40 C (ST, PRP) T4 40 C +90 C (ST, PRP) T3 40 C +160 C (HT) II 2D Ex td A21 IP6X T85 C 40 C +40 C (ST, PRP) T135 C 40 C +90 C (ST, PRP) T200 C 40 C +160 C (HT) EXAM Test Reports: PFG-41300204P HT sensor and wall mount bracket 3

Technical Specifications Sensor Power consumption Measuring range Response time Operating life Storage life 1 watt typical 0 100% LEL t 50 10 sec. t 90 30 sec. 3 years minimum in clean air @ STP 5 years minimum in MSA container @ STP Storage temperature 20 C to +40 C Operating temperature range 40 C to +55 C (ST & PRP) 40 C to +90 C (extended range*) 40 C to +160 C (HT) Operating humidity range 5% to 95% RH non-condensing Operating pressure range 100 ±20 kpa Air velocity 0 6 m/s (with duct mount flange 0.5 20 m/s) Poison resistance PRP sensor only: 10 ppm HMDS for 40 min. (max. signal loss 5% of reading) Weight Dimension Material Accessory thread Sensor to junction box ca. 230 g (St.St. sensor) Ø 36 x 56 mm Stainless steel M36 x 1.5 mm 3/4 NPT or M25 x 1.5 mm EC Type Certificate: INERIS 03 ATEX 0208 Safety Integrity Level SIL 2 (IEC 61508) *Extended range: The sensor extended temperature range is greater than the maximum specified in 60079-29-1. It is therefore strongly recommended that if used above +55 C the sensor is calibrated at the operating temperature. Junction Box Flameproof (Ex d) Increased safety (Ex e) Weight 870 g 813 g Cable gland thread 3/4 NPT M25 x 1.5 mm Terminals 5 x 2.5 mm 2 5 x 2.5 mm 2 Material Aluminium (powder coated) Dimension 120 x 97 x 170 mm (W x D x H) EC Type Certificate: BVS 10 ATEX E 066X II 2G Ex d IIC T6 or T4 II 2G Ex e II T6 or T4 II 2D Ex td A21 IP6x T85 C or T135 C T6 40 C Ta +40 C T4 40 C Ta +90 C T85 C 20 C Ta +40 C T135 C 20 C Ta +50 C Ordering Information Gas Detector (Sensor & Junction Box) Part-No. Description Sensor Junction Box Material Thread Type 10120403 47K-ST St.St. 316 M25 x 1.5 Ex e 10114106 47K-PRP St.St. 316 M25 x 1.5 Ex e 10120404 47K-ST St.St. 316 3/4 NPT Ex d 10114107 47K-PRP St.St. 316 3/4 NPT Ex d Sensor Part-No. Description Material Thread 10048117 47K-ST St.St. 316 M25 x 1.5 10048118 47K-PRP St.St. 316 M25 x 1.5 10048271 47K-ST St.St. 316 3/4 NPT 10048272 47K-PRP St.St. 316 3/4 NPT 10048825 47K-HT St.St. 316 3/4 NPT 10048199 47K-HT St.St. 316 M25 x 1.5 Junction Box & Wall Mount Bracket Part-No. Description Material 10114111 Ex e, 2 x M25 x 1.5 Aluminium 10114112 Ex d, 2 x 3/4 NPT Aluminium 10048829 Wall mount bracket Ø 25 mm St.St. 316 10062674 HT junction box 100 C Aluminium Accessories Part-No. Description Material 10049316 Calibration cap PVC 10051623 Weather protection cap hose St.St. 316 10051731 Weather protection cap 1/8 NPT St.St. 316 10051625 Flow-through adapter St.St. 316 10051626 Flow-through adapter Aluminium 10051627 Duct mount flange Aluminium Flow-through adapter Calibration cap Weather protection cap MSA (Britain) Limited Lochard House Linnet Way Strathclyde Business Park BELLSHILL ML4 3RA Phone +44 (0)16 98 5733 57 Fax +44 (0)16 98 74 01 41 E-mail info@msabritain.co.uk www.msabritain.co.uk Subject to change without notice ID 07-240.2 UK/07/12.11 MSA Europe Thiemannstrasse 1 12059 Berlin Germany Phone +49 (0)306886-0 Fax +49 (0)30 68 86-1517 E-mail contact@msa-europe.com www.msa-europe.com MSA International 1000 Cranberry Woods Drive Cranberry Township, PA 16066 Phone +1 412 967 33 54 Fax +1 412 967 34 51 E-mail msa.international@msanet.com www.msanet.com Duct mount flange