AIR HANDLING UNITS ver B

Similar documents
AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

EC L2. and humidity sensors. All units are supplied tested and ready to install.

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

RIS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. AHU med varmegenvinding AIR HANDLING UNITS

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

new HYGIENE AND COMFORT FOR HOSPITALS AND PUBLIC BUILDINGS HYGIENIC AIR HANDLING UNITS HYGIENIC AHU N o : Range: AmberAir

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

RIS V. AHU with heat recovery. exchanger. AHU is used for ventilation of houses and other heated areas. Stouch and TPC remote control devices.

SMART WAY TO HANDLE THE AIR

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

VERSO Air Handling Units

SMART WAY TO HANDLE THE AIR

TSEK VHR EC HEAT RECOVERY UNITS

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

VERSO Air Handling Units

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

CONTENT: VEX308 Decentralised ventilation VEX308

DAIKIN Air Handling Unit Modular

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Energy efficient ventilation equipment

VENTILATION. Effective heat exchange and fresh air ventilation

Heat Recovery Air Handling Units

KOMFORT EC DB Suspended heat recovery air handling units

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

We simplify construction

We simplify construction

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

EASYAIR COMPACT DEVICE THE EASY WAY OF AIR HANDLING.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

CONTENT: VEX300C Ceiling units VEX320C/330C

Corrigo E. Second generation which contains all applications and languages

We simplify construction

Elektros montavimo ir eksploatavimo instrukcija 2 Electrical installation and Operation Manual 18 Инструкция по электромонтажу и эксплуатации 34

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

air handling units Issue 2016 ver. A

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

The plug & play fresh Air Solution

Small Room Heat Recovery Ventilation

UNITES TERMINALES ET MINI CTA FIDJI

Series VENTS VUT R WH ЕС

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Manual for the integration in BMS/GTC

VEX100 series Air handling units with cross-flow heat exchanger

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Air handling units Compair. Technical Catalogue

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Dee Fly Cube 300 and 370. Heat Recovery ventilation

48 50 UH UA PACKAGED ROOFTOP

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

DOMEKT. Heat Recovery Air Handling Units

MRXBOXAB-ECO3 MRXBOX-ECO3

G Installation manual Solitude - dmev unit

The new Xcell EC High Efficiency Range Fresh air pure and simple

MRXBOXAB-ECO2 MRXBOX-ECO2

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

AHU Plus. DX Air Handling Units

Technical Information HXV - HRV Ventilation

Technical manual MARK WTW AIRSTREAM _R01

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

SILVERTOP RANGE ENERGY RECOVERY

FUNCTION MANUAL, INSTALLATION GOLD RX/PX/CX/SD Generation F. Applicable to Program Version 1.27 and newer versions

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

ggg Air Handling Unit RT 700/1000S-EC-RS INSTALLATION OPERATION & CONTROL PANEL MAINTENANCE & SERVICE

DOMEKT. Residential ventilation air handling units

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Energy efficient ventilation equipment

Mikael Börjesson Product manager. Commercial air handling units Ventilation functionality Building management system integration

Swegon Home Solutions CASA. R2 Smart. Installation, commissioning and maintenance instruction. R2_a_EN-t

Operation and maintenance instructions

COTES ALL-ROUND THE C105 RANGE

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

DOMEKT. Residential ventilation units

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Transcription:

AIR HANDLING UNITS www.salda.lt 2013 ver B

EC High efficiency air handling units are supplied with crosscounter flow plate heat exchangers. AHU is used for ventilation of houses and other heated areas. Wide range versions: vertical, horizontal and ceiling mounted. Compact design fits doors up to 900mm width (excluding 5500 ). Efficient low - noise EC fans. Efficiency of cross-counter flow plate heat exchanger up to 94%. Stainless steel bath with condensate drain. Fully integrated plug & play control system. Integrated electrical heater (excluding 400 VE/W and 150P ). Optionally supplied water heater/cooler on the duct or Comfort box (from sizes 1900) For cold areas (winter lower -7C) recomended to use pre-heater EKA NV PH. units equipped with motorized by-pass damper (excluding 150P ). 2500-5500 H is equiped with fresh air and extract air motorized dampers. Powder coated white color painting RAL 9016 150-700. Powder coated grey color painting RAL 7040 1200-5500 Optional CO2, pressure or airflow transmitter 1900H - 5500H optional roof and outlet cover. 3500H - delivered in three sections and 5500H in two sections. RIRS High efficiency air handling units RIRS are supplied with rotor heat exchangers. AHU is used for ventilation of houses and other heated areas. Wide range RIRS versions: vertical, horizontal and ceiling mounted. Compact design fits doors up to 900mm width. Efficient low - noise EC fans. Efficiency of rotor heat exchanger up to 80%. Fully integrated plug & play control system. Integrated electrical heater Optionally supplied water heater/cooler on the duct or Comfort box (from sizes 1900). Integrated fresh air and extract air motorized dampers (RIRS 2500-5500 ). Powder coated white color painting RAL 9016 RIRS 200 - RIRS 300. Powder coated grey color painting RAL 7040 RIRS 400 - RIRS 5500. Optional CO2, pressure or airflow transmitter RIRS 1900H - 5500H optional roof and outlet cover RIRS 3500 5500 delivered in three sections. Efficient air handling units EC are supplied with cross flow plate heat exchangers. AHU is used for ventilation of houses and other heated areas. Only horizontal version. Compact design fits doors up to 900mm width (excluding 5500 EC). Efficient low - noise EC fans. Efficiency of cross flow plate heat exchanger up to 65%. Fully integrated plug & play control system. Integrated electrical heater (control 0-10V). Optionally supplied water heater/cooler on the duct or Comfort box. For cold areas (winter lower -7oC) recomended to use pre-heater EKA NV PH. units equipped with motorized by-pass damper Powder coated painting 7040 Optional CO2, pressure or airflow transmitter. 2500H - 5500H EC optional roof and outlet cover 5500H - delivered in two sections. Simple solution air handling units are supplied with cross flow plate heat exchangers. AHU is used for ventilation of houses and other heated areas. Wide range versions: vertical, horizontal and ceiling mounted. Low noise AC fans Efficiency of cross flow plate heat exchanger up to 65%. Integrated electrical heater and water heater or optionally supplied on the duct For cold areas (winter lower -7 o C) recomended to use pre-heater EKA NV PH units equipped with motorized by-pass damper Powder coated painting 7040. RIRS Simple solution air handling units RIRS are supplied with rotor heat exchangers. AHU is used for ventilation of houses and other heated areas. RIRS versions: vertical, horizontal Low noise AC fans Efficiency of rotor heat exchanger up to 80%. Integrated electrical heater and water heater or optionally supplied on the duct. Powder coated painting 7040. FUNCTIONS Controllers Descriptions of the functions FLEX controller ECO PRV V2.2 E W E W Adjustment of the new controller with control automatics Full control (service control included). UNI PRO TPC* Absent control functions: Boost configuration menu (time, fan speed, night cooling), temperature and time configuration of water heater); Service menu- PI configuration; Review of separate alarms at one time; DX cooling configuration possibility; Night cooling fast button setting; Supply and extract air fans speed control (3 speed can be configured); Functional components type choice. UNI PRO TPC Demand-Controlled Ventilation for extracted air. Using one pressure or one CO2 transmitter. DCV systems control DCV systems control Demand-Controlled Ventilation for extracted and supplied air. Two pressure or one CO2 transmitter.

Main functions and control of functional units 8 events for each day or weekday group* per week. *1-7 entire week, 1-5 working days, 6-7 weekend. Descriptions of the functions FUNCTIONS User and servicing control level Week timer + Holidays + Digital timer channels ECO PRV V2.2 E W E W START/STOP function,,start/stop function for starting or stopping operation of the heat recovery unit. STOP sign is indicated on a remote control (Flex). It can be used with door lock, motion sensor (PIR), outside switch or other external digital signal (potentialfree contacts). On a position,,start heat recovery unit operates according to the last remote controller settings. Year-round optimization of recovery unit regulation Winter heat recovery; Summer cold recovery; Autumn and spring low rotor speed/half by-pass opened. Free Cooling function The premises are cooled down by supplying fresh air, when exhaust air temperature is higher then fresh air. (Night cooling function) Cool recovery The heat exchanger recovers cold air from exhaust air when premises temperature is lower than outside. ON/OFF rotor motor control 0-10V DC rotor motor speed control By-pass ON/OFF By-pass three-positional control Minimum and maximum limits for supply air temperature By activating temperature control according to extracted air sensor (Min. -15 C, Max. +40 C adjustable in service menu). Accuracy of 0,5 C for supply air temperature. For the bigger capacity electric heaters. ON/OFF control of electric post-heater Pulse-width modulation (PWM) control of electrical heater Electric heater s control by stages ON/OFF control of DX coolers Water cooler control with three-positional valve actuator ON/OFF control of circulation pump Fans speed synchronous 0-10V control Separate fans speed asynchronous 0-10V control 4 speeds for easy end-user control. Stop the unit is stopped; Low, Medium, and High. Service menu allows adjusting each speed individually. BOOST function Fans operate at high speed (set in service menu). Operation time is also set in service menu. Boost function is reflected in FLEX remote. Fan speed control only. Possibility to connect CO2 or two pressure transmitters. Web-based software control. Safety/emergency signal indications Additional electrical heater overheat protection (software). CO2, constant pressure, humidity control CO2, constant pressure control Supply air temperature control according to the extract air sensor Exhaust air damper control Supply air damper control Remote control ModBus input Remote controller input General emergency signal Overheat protection Rotor fail alarm signal In case of rotor belt break-up or rotor operation stopping indication RotorFail appears on FLEX remote controller. The AHU stops till service is restored in FLEX remote controller. Fire alarm signal Fire and smoke alarm input Fans overheating alarm signal Filter pollution indicator by pressure drop transmitter Filter pollution indicator by working hours A possibility to choose period of time after which indication informs about necessity to change the filters. (Min. 168 h, Max. 6482 h) Number of working hours set as default -2160h. Other indications Unit in operation signal. Unit off operation signal. FanRun function FanFail function Extracted air temperature sensor Exhaust air temperature sensor Returning water temperature sensor Extracted air relative humidity converter Fresh air temperature sensor Supplied air temperature sensor

TECHNICAL DATA Housing type 150 200 260 400 150P Ceiling mounted 200VE 200VW 260VE 260VW 400VE 400VW 400VE 400VW 400HE 400HW Vertical Vertical Vertical Vertical Horizontal 400PE 400PW Ceiling mounted Max airflow (m 3 /h) at 0 Pa 220 250 285 450 450 450 490 450 Insulation (mm) 20 30 20 30 30 50 30 30 Connection diameter (mm) 160 125 125 160 160 160 200 160 Fan type EC EC AC EC AC AC EC AC 400PE Power consumption for 1 fan (kw) 0,055 0,06 0,08 0,13 0,21 0,2 0,1 0,17 - - E - 1 kw - E - 2 kw E - 2 kw - W - 0,34 W - 1,75 kw W - 3,67 W - 2,69 kw W - 2,7kW NEW! E-0,9/1,6/3 kw W - 4,04 Cooler : 7 / 12 o C - - - 0,94 * - - 1,15 * - 400PW Ceiling mounted E - 2 kw Filter class (supply / extract air) integrated F7/G4 M5/G3 M5/G3 F7/G4 M5/G4 M5/G4 F7/M5 M5/M5 Motorized by-pass damper - x - x - - x - Maintanance side: convertable - - - - - - - - Maintanace side: left or right - x x x x - - - Integrated control system - x x x x x x x Comply with ErP 2013 + + + + + + + + W - 2,69 TECHNICAL DATA 700VE 700VW 700HE 700HW 700VE 700VW 700 700HE 700HW 700PE 700PW 700PE 700PW Housing type Vertical Horizontal Vertical Horizontal Ceiling mounted Ceiling mounted Max airflow (m 3 /h) at 0 Pa 850 830 780 820 853 700 Insulation (mm) 30 30 30 50 30 30 Connection diameter (mm) 250 250 200 250 250 250 Fan type EC EC AC AC EC AC Power consumption for 1 fan (kw) 0,28 0,2 0,2 0,23 0,22 0,21 NEW! E - 1,2 kw E - 1,2 kw E - 3 kw E - 3 kw E-1,2/3/4,5 kw E - 3 kw W - 5,17 W - 5,17 W - 4,7 W - 4,7kW W - 5,17 W - 4,7 kw Cooler : 7 / 12 o C 1,76 * 1,76 * - - 1,5/3/4,5 * - Filter class (supply / extract air) integrated F7/M5 F7/M5 M5/G3 M5/G3 F7/M5 M5/M5 Motorized by-pass damper x x - - x - Maintanance side: convertable - x - x - - Maintanace side: left or right x - x - - - Integrated control system x x x x x x Comply with ErP 2013 + + + + + +

TECHNICAL DATA 1000VE 1000VW 1000 1200 1000HE 1000HW 1000PE 1000PW 1200VE 1200VW 1200HE 1200HW 1200PE 1200PW Housing type Vertical Horizontal Ceiling mounted Vertical Horizontal Ceiling mounted Max airflow (m 3 /h) at 0 Pa 1260 1270 1200 1390 1330 1380 Insulation (mm) 50 50 30 50 50 50/30 Connection diameter (mm) 315 315 315 315 315 500x250 Fan type AC AC AC EC EC EC Power consumption for 1 fan (kw) 0,24 0,23 0,303 0,43 0,46 0,37 E - 6 kw E - 6 kw E - 6 kw E - 2 kw E - 2 kw E - 3/6/9 kw W - 6,7 kw W - 6,75 kw W - 11,3 W - 11,3 W - 11,3 W - 10,98 Cooler : 7 / 12 o C - - 3,84 * 4,39 * 4,39 * - Filter class (supply / extract air) integrated M5/M5 M5/M5 M5/M5 F7/M5 F7/M5 F7/M5 Motorized by-pass damper x x x x x x Maintanance side: convertable - x - - x - Maintanace side: left or right x - - x - - Integrated control system x x x x x x Comply with ErP 2013 + + - + + + NEW! TECHNICAL DATA 1500VE 1500VW 1500 1900 1500HE 1500HW Housing type Vertical Horizontal 1500PE 1500PW Ceiling mounted 1900HE 1900HW Horizontal 1900VE 1900VW Verticale 1900PE 1900PW Ceiling mounted 1900HE 1900HW Horizontal Max airflow (m 3 /h) at 0 Pa 1570 1540 1660 2190 1980 2290 2030 Insulation (mm) 50 50 50 50 50 50 50 Connection diameter (mm) 315 315 500x250 400 400 700x300 400 Fan type AC AC AC EC AC EC AC Power consumption for 1 fan (kw) 0,38 0,37 0,37 0,55 0,65 0,49 0,67 E - 9 kw E - 9 kw E - 9 kw E - 3 kw E -15 kw W - 9,4 kw W-10,1 kw W - 10,1 W - 3,2 W - 12,8 kw NEW! E - 12/6/3 kw W - 18,6 Cooler : 7 / 12 o C - - - 9,5 * - - - E - 15 kw W - 12,8 kw Filter class (supply / extract air) integrated M5/M5 M5/M5 M5/M5 F7/M5 M5/M5 F7/M5 M5/M5 Motorized by-pass damper x x x x x x x Maintanance side: convertable - x - x - - x Maintanace side: left or right x - - - x - - Integrated control system x x x x x x x Comply with ErP 2013 + + + + - + -

TECHNICAL DATA 2500HE 2500HW 2500 3500 5500 2500HE EC 2500 HW EC Housing type Horizontal Horizontal 2500PE 2500PW Ceiling mounted 3500HE 3500HW 3500HE EC 3500HW EC 5500HE 5500HW 5500HE EC 5500 HW EC Horizontal Horizontal Horizontal Horizontal Max airflow (m 3 /h) at 0 Pa 3330 3000 2900 4130 450 6210 6500 Insulation (mm) 50 50 50 50 50 50 50 Connection diameter (mm) 600x350 600x350 700x400 800x500 600x350 800x500 800x500 Fan type EC EC EC EC EC EC EC Power consumption for 1 fan (kw) 1 0,72 0,72 1,17 1,37 1,87 2,03 E - 3,6 kw W - 4,2 E - 18 kw W - 21,29 NEW! E - 18/9/4,5 kw W - 22,3 E - 6 kw E - 24 kw E - 12 kw E - 30 kw W - 5,9 W - 28,27 W - 9,3 W - 49,81 Cooler : 7 / 12 o C 12,4 * 12,4 * - 21 * 21 * 26,3 * 26,3 * Filter class (supply / extract air) integrated F7/M5 M5/M5 F7/M5 F7/M5 M5/M5 F7/M5 M5/M5 Motorized by-pass damper x x x x x x x Maintanance side: convertable - x - - x - x Maintanace side: left or right - - - - - x - Integrated control system x x x x x x x Comply with ErP 2013 + + + + + + +

RIRS TECHNICAL DATA 200 300 350 RIRS 200VE RIRS 200VW RIRS 300VE RIRS 350PE RIRS 350PW Housing type Vertical Vertical Ceiling mounted Max airflow (m 3 /h) at 0 Pa 260 300 420 Insulation (mm) 20 20 30 Connection diameter (mm) 125 125 200 Fan type EC EC EC Power consumption for 1 fan (kw) 0,07 0,12 0,14 E-0,6 kw E - 0,6 kw E - 0,6 kw Cooler : 7 / 12 o C 0,65 * 0,8 * 1,07 * Filter class (supply / extract air) integrated M5/M5 M5/F5 F7/M5 Motorized by-pass damper x x - Maintanance side: convertable - - - Integrated control system x x x Comply with ErP 2013 + + + RIRS TECHNICAL DATA RIRS 400VE RIRS 400VW RIRS 400HE RIRS 400HW 400 RIRS 400VE RIRS 400VW RIRS 400HE RIRS 400HW Housing type Vertical Horizontal Vertical Horizontal Max airflow (m 3 /h) at 0 Pa 490 545 450 480 Insulation (mm) 50 50 50 50 Connection diameter (mm) 160 200 160 160 Fan type EC EC AC AC Power consumption for 1 fan (kw) 0,14 0,13 0,18 0,18 E - 1,2 kw E - 1,2 kw E-1,2 kw E - 1,2 kw W-2,02 W-2,02 W - 2,02 W - 2,02 Cooler : 7 / 12 o C 0,94 * 0,94 * - - Filter class (supply / extract air) integrated F7/M5 F7/M5 M5/M5 M5/M5 Motorized by-pass damper - x - x Maintanance side: convertable x - x - Integrated control system x x x x Comply with ErP 2013 + + + +

RIRS TECHNICAL DATA RIRS 700VE RIRS 700VW RIRS 700HE RIRS 700HW 700 RIRS 700VE RIRS 700VW RIRS 700HE RIRS 700HW Housing type Vertical Horizontal Vertical Horizontal Max airflow (m 3 /h) at 0 Pa 890 830 810 920 Insulation (mm) 50 50 50 50 Connection diameter (mm) 250 250x125 250 250 Fan type EC EC AC AC Power consumption for 1 fan (kw) 0,22 0,21 0,28 0,3 E - 1,2 kw E - 2,0 kw E - 2,0 kw E - 2,0 kw W - 3,54 * W - 3,54 * W - 3,54 W - 3,45 Cooler : 7 / 12 o C 2,5 * 2,5 * - - Filter class (supply / extract air) integrated F7/M5 F7/M5 M5/M5 M5/M5 Motorized by-pass damper - x - x Maintanance side: convertable - - x - Integrated control system x x x x Comply with ErP 2013 + + + + RIRS TECHNICAL DATA RIRS 1200VE RIRS 1200VW 1200 1500 RIRS 1200HE RIRS 1200HW RIRS 1500VE RIRS 1500VW RIRS 1500HE RIRS 1500HW Housing type Vertical Horizontal Vertical Horizontal Max airflow (m 3 /h) at 0 Pa 1530 1520 1640 1700 Insulation (mm) 50 50 50 50 Connection diameter (mm) 315 315 315 315 Fan type EC EC AC AC Power consumption for 1 fan (kw) 0,42 0,44 0,39 0,39 E - 4,0 kw E - 4,0 kw E - 4,5kW E - 4,5 kw W - 12,03 kw W - 12,03 kw W-7,58 W - 7,58 kw Cooler : 7 / 12 o C 4,39 * 4,39 * - - Filter class (supply / extract air) integrated F7/M5 F7/M5 F5/M5 M5/M5 Motorized by-pass damper - x - x Maintanance side: convertable x - x - Integrated control system x x x x Comply with ErP 2013 + + + +

RIRS TECHNICAL DATA RIRS 1900VE RIRS 1900VW 1900 RIRS 1900HE RIRS 1900HW Housing type Vertical Horizontal Max airflow (m 3 /h) at 0 Pa 2210 2130 Insulation (mm) 50 50 Connection diameter (mm) 315 315 Fan type EC EC Power consumption for 1 fan (kw) 0,57 0,57 E - 9,0 kw W - 35,3 kw E - 9,0 kw W - 35,3 kw Cooler : 7 / 12 o C 5,58 * 5,58 * Filter class (supply / extract air) integrated F7/M5 F7/M5 Motorized by-pass damper - x Maintanance side: convertable x - Integrated control system x x Comply with ErP 2013 + + RIRS TECHNICAL DATA 2500 3500 5500 RIRS 2500HE RIRS 2500HW RIRS 3500HE RIRS 3500HW RIRS 5500HE RIRS 5500HW Housing type Horizontal Horizontal Horizontal Max airflow (m 3 /h) at 0 Pa 2992 4545 7015 Insulation (mm) 50 50 50 Connection diameter (mm) 700x400 700x400 800x500 Fan type EC EC EC Power consumption for 1 fan (kw) 0,75 1,3 2,0 E - 9,0 kw E - 12,0kW E - 15,0kW W - 24,35 kw W - 30,0 kw W - 47,21 kw Cooler : 7 / 12 o C 5,77 * 5,77 * 8,77 * Filter class (supply / extract air) integrated F7/M5 F7/M5 F7/M5 Motorized by-pass damper x x x Maintanance side: convertable - - - Integrated control system x x x Comply with ErP 2013 + + +

Notes

Notes

Notes UAB SALDA, Ragainės g. 100, LT-78109 Šiauliai, Lithuania. Tel. (+370 41) 54 04 15. Fax. (+370 41) 54 04 17. E-mail: office@salda.lt www.salda.lt