VERSO. Commercial ventilation units 01/03/ Tél

Similar documents
DOMEKT. Residential ventilation units

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO Air Handling Units

VERSO Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

VERSO DOMEKT. Residential ventilation units m³/h. Commercial ventilation units m³/h

AHU N : Range: VERSO VERSO. Air handling units. Plug & Play Energy Saving Smart Design Reliable & Safe

Domekt R. Air handling units with a rotary heat exchanger. Operating capacity ranges from 50 to 950 m 3 /h. Advantages of Domekt R units

KOMPAKT. Air Handling Units

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

DOMEKT Residential ventilation units

17 Domekt R. Units with a rotary heat exchanger. Domekt RHP Units with a rotary heat exchanger and an integrated heat pump.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Heat Recovery Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

DOMEKT. Heat Recovery Air Handling Units

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

KOMFORT EC DB Suspended heat recovery air handling units

Series VENTS VUT R WH ЕС

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

AIR HANDLING UNITS MANDÍK

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

The ultimate in air handling units: directly and indirectly fired

recooler HP EQKR HEAT PUMP

Air Handling Units. Geniox. Quick guide

TopMaster Air Handling unit. Technical data

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

Roof top SPACE RPC 450Z R407C M011

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SMART WAY TO HANDLE THE AIR

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

The ultimate in air handling units: directly and indirectly fired

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Air Cooler Industry OK-ELC 0-7

Energy efficient ventilation equipment

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Roof top SPACE RPC 315Z R407C MA00

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

C5.1. VERSO Pro S / R / P / RHP / PCF. EN Installation and Maintenance Service Manual

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Energy efficient ventilation equipment

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Aegean Range. A new range of fan coils for heating and cooling commercial applications

VEX100 series Air handling units with cross-flow heat exchanger

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Outstanding Performance; Application Flexibility

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

Specification data Topvex. Rotating or Cross flow heat exchanger.

Air Handling Units. Geniox. Catalogue

EC L2. and humidity sensors. All units are supplied tested and ready to install.

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

The ultimate in air handling units: directly and indirectly fired

UNITES TERMINALES ET MINI CTA FIDJI

QTS SELECTION TECHNICAL BOOKLET

AIR COOLED CONDENSERS

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

COMMERCIAL LINE DUPLEX ROTO

AIR HANDLING UNITS ver B

Air Handling Units. Real HVACR people who understand your needs.

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

The ultimate in air handling units: directly and indirectly fired

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

VERSO Pro S / R / P / RHP / PCF. EN Installation and Maintenance Service Manual

Industrial cooling solutions

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Transcription:

VERSO ommercial ventilation units istribué par ERI : contact@aeria-france.fr KOMFOVENT fabriqué par : U MLV www.komfovent.com SOUS RÉSERVE E MOIFITION SNS PRÉVIS 1/3/218 www.aeria-france.fr Tél 2 51 13 38 13 contact@aeria-france.fr 1

1 4 (m 3 /h) Eurovent certified VERSO units are tested on a regular basis at the Eurovent climatic laboratory in Germany. Parameters such as performance, efficiency, noise level, tolerances and others are tested. Energy saving technology Units are equipped with the most efficient and advanced technical solutions: high efficiency PM/ E fans, non-freezing rotary heat exchangers, high efficiency counter flow heat exchangers, high surface area air filters. ll of these solutions greatly reduce operational costs and shorten payback time. PM motors Ultra Premium efficiency IE5 class PM fan motors minimize power consumption and ensure durability of the unit. Plug & Play all included ll units are assembled and tested at the factory, therefore installation and commissioning work is significantly simplified. Integrated intelligent automation requires minimum user input. Factory predefined settings simply "Plug and Play". The user can change every setting according to individual preferences. Units can be monitor and controlled remotely via the Internet. Inteligent control Smart algorithms in the integrated automation ensure reliable and efficient operation of the unit and reduce operating costs. Energy recovery Non-freezing rotary heat exchangers efficiently recover heat and cold, control humidity and provide comfort throughout the year. HU N : 7.9.356 Range: VERSO www.aeria-france.fr 2

Wide range VERSO units are designed for efficient ventilation and are suitable for various types of projects. You can choose unified unit from VERSO Standard series, or VERSO Pro which can be specifically tailored to meet your requirements. Large number of configurations (vertical, horizontal, flat and universal type, with rotary or plate heat exchangers) allows you to always select optimal and most efficient solution. Verso R units with a ro ta ry he at ex chan ger Verso F units with a counterflow plate heat exchanger Verso P units with a pla te he at ex chan ger Verso S sup ply air units VERSO Standard VERSO Pro ENERGY EFFIIENY 7.9.356 + + 216 E Report to performance data ENERGY EFFIIENY 7.9.356 + + 216 E Report to performance data 8 m³/h m³/h Vertical, horizontal, flat or universal application ompact design Models for REVIT software 1 basic sizes for various combinations Professionally convenient software Selection of desired heat exchanger, fan, heater/cooler REVIT models M5/F7 G4/M5/M6/F7/F9 PM/E 5 rotor options 6 options 7 options different thermal and enthalpy efficiency One size 3 coil sizes www.aeria-france.fr 3

Verso R ir handling units with a rotary heat exchanger Sizes of Verso R units ir flow, m³/s,6,11,17,22,28,42,55,69,83 1,11 1,38 2,2 7 2 17 1 1 6 8 1 2 8 ir flow, m³/h dvantages of Verso R units Energy saving The rotary heat exchanger effectively regenerates the sensible and latent heat, which significantly saves both heating and air conditioning costs throughout the year. Efficient heat Under the normal operational conditions, the rotary heat exchanger does not freeze: even at outdoor temperatures below -2, no additional warming up required of the outdoor air which results in efficient heat energy saving even in the presence of hard frosts. ir humidity balance Under the normal operating conditions, condensation does not form in the process of heat exchange in the rotary heat exchanger, because most of the moisture is returned to to the premises. Excess moisture is removed outside. The air in the premises is less dry and the air humidity balance is maintained. s condensation does not form, drainage is not necessary this simplifies the mounting of the unit. Low noise level Verso R air handling units are equipped with silently ope rating fans and sound insulation, which ensures low noise level. Rotary heat exchanger dvantages of rotary heat exchanger High efficiency coefficient. Non-freezing. Humidity is transferred to supply air a lower power humidifier may be needed. No drainage is necessary easy unit installation. Very compact in size. ooled air may be recovered that results in the reduced energy consumption for air cooling. The efficiency on the demand: two levels of rotor efficiency are available. Optimum efficiency is achieved with L type rotor, higher values may be reached with optional SL type rotor. ir handling units are equipped with three types of rotary heat exchangers: ondensation heat exchanger is made from aluminum foil (L). It recovers moisture. Enthalpy heat exchanger is made from hygroscopic and aluminium foil (ZM). It recovers moisture more efficiently than L type exchanger. Sorption heat exchanger is made from hygroscopic aluminum foil (Z). Heat exchan gers of this type regenerate moisture the most efficiently. Energy efficient E motor Rotary heat exchangers are equipped with E motors, which ensure the smooth rotor ope ration and control. Preheater s an additional protection for very low outdoor temperatures such as -3 o and lower, it is recommended to use duct mounted preheater. www.aeria-france.fr 4

Verso R range Unit size standard equipment possible choice ordered separately duct heater/cooler * available only L wave height Type Heat exchanger Wave height Supply/exhaust air filter class Heater ooler Inspection side ontrol system 5 L Z* ZM* L SL M5 F7 HE HW HW W X R1 L1 panel 5.1 Verso R U Verso R H/V Verso R 1 U Verso R 1 H/V Verso R 1 F Verso R 1 U Verso R 1 H/V Verso R 17 U Verso R 17 H/V Verso R U Verso R H/V Verso R F Verso R 2 H Verso R U Verso R H/V Verso R F Verso R U Verso R H/V Verso R H Verso R 7 H uct connection H horizontal V vertical U universal, 14 installation options F false ceiling Heat exchanger L aluminum, condensing rotor. s a standard, units are equipped with L wave height of the rotors. In exceptional cases, when increased thermal efficiency is required, the units can be equipped with SL wave. Z sorption rotary heat exchanger coated with special 4Å coating. Wave height of this heat exchanger is L. ZM enthalpy rotor is "hybrid" that combines the good condensing and sorptive heat exchanger properties, e.g. high temperature efficiency and good performance of latent (the hidden) energy transfer, thus effectively operates both in and summer. Wave height of this heat exchanger is L. Heater HE electric heater. HW water duct heater is installed on the duct and must be ordered separately. Heaters are mounted on the outside of the unit in any userconvenient place....1 V heater control included in automatic control system. HW heater-cooler one for both heating and cooling. Ideal for buildings using geothermal energy. ooler W designed for air cooling using cold water (water-glycol mixture), provides a higher comfort level in rooms. X designed for air cooling using direct expansion cooling unit, provides a higher comfort level in rooms. Inspection side See p. 116. ontrol system 5 ontrol features: 5 different operation modes: omfort1, omfort2, Economy1, Economy2 and Special; Temperature control modes: Supply air / Extract air / Room; Energy parameters indication: thermal efficiency of the heat exchanger, heat exchanger's recovered energy, energy saving indicator; ir quality, minimum temperature control; Flow control modes: V, VV and V; Weekly operating schedule; ir flow indication (m 3 /h, m 3 /s, l/s); Rotary or plate heat exchanger failure protection; Rotary heat exchanger cleaning and warm-up function; Intelligent self-diagnostic; night cooling; ir quality function; Supply air temperature control; Min. supply air temperature maintenance; ombined water heater & cooler control; Inverter-type X outdoor unit control; ooling recovery function; Outdoor compensated ventilation; Humidity control: air humidification and dehumidification*; irculation pumps control by demand; Warm-up function of circulation pumps and mixing valves; ir filter clogging indication; Operation hours and energy counters; Remote control via web interface; uilt-in data logger for all air handling unit parameters; pplication software for smartphones based on ndroid and ios. * additionally ordered function. www.aeria-france.fr 5

Verso R U / H / V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 9 196 1~23 7,3 3,3 8 46-M5 178 3 / 9,3 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing,5,1,15,2,25,3 58 72 58 7 51 -weighted sound pressure level L P, d() 41 282 372 247 315 (4x) 247 372 282 412 95 412 1355 15 96 2 2 855 6 8 1 ir flow rate (m 3 /h) 96 398 Performance (Verso R UH data) ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 13,9 15,4 16,3 17,2 18,1 22,5 23,4 24,3 indoor +22, 1% RH hangeover water heating/cooling exchanger (HW) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 2,4 2,4 2,4 5,6 18 18 17 954 1,8 1,9 1,9 24,9 Temperature in/out, 13,9/22 24,3/18 13,1 1,6 8,1 9,4 onnection, ½ 98 15 253 315 (4x) ccessories (p. 18) losing damper Water heater X cooler ooling unit / / GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M -HW-3R-15-,63-W1 W-,9-6 VVP47.15-2,5+SSP61 F-,9-6 MOU-18HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 6

Verso R 1 U / H / V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 1 23 1~23 11,7 5,5 8 46-M5 221 4,5 / 9,6 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing 57 71 57 68 51 -weighted sound pressure level L P, d() Performance (Verso R 1 UH data) ir flow rate (m 3 /s),8,16,24,32,4 6 41 247 412 15 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 12,9 14,5 15,5 16,5 17,5 22,6 23,6 24,6 indoor +22, 1% RH hangeover water heating/cooling exchanger (Hw) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 4, 4, 4, 8,3 175 175 174 1429 2,3 2,4 2,4 51,2 Temperature in/out, 12,9/22 24,6/18 17,7 14,4 11,1 12,3 onnection, ½ 282 372 98 1355 15 247 95 412 315 (4x) 372 96 2 282 2 855 6 8 1 1 16 ir flow rate (m 3 /h) 253 oes not conform to ErP218 requirements 96 398 315 (4x) ccessories (p. 18) losing damper Water heater X cooler ooling unit / / GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M -HW-3R-15-1-W2 W-1,2-8 VVP45.2-4.+SS61 F-1,2-8 MOU-36HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 7

Verso R 1 F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 1 144 1~23 1,7 6,7 41 42 46-M5 428 3 / 5,6 5.1 5.1 coustic data -weighted sound power level L w, d() asing 68 77 67 76 59 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),5,1,15,2,25,3,35,4,45,5 49 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 9,4 11,6 13, 14,4 15,8 22,8 24,2 25,7 indoor +22, 1% RH Hot water duct air heater (H)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 6,3 6,3 6,3 28 279 277 17,2 17,3 17,5 Temperature in/out, 9,4/22 14,3 11,8 9,3 onnection, ½ * option 315 (4x) 94 245 445 22 48 136 151 22 245 445 1 6 9 1 1 18 ir flow rate (m 3 /h) oes not conform to ErP218 requirements Shown as left (L1) ccessories (p. 18) losing damper / / Water heater ir heater-cooler X cooler ooling unit GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M H-315 -HW-3R-15-1-W2 W-1,2-8 / HW-315 VVP47.15-2,5+SSP61 F-1,2-8 MOU-24HFN6-K8243 outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 8

Verso R 1 U / H / V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 18 26 1~23 12,9 6,7 8 46-M5 444 4,5 / 6,9 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing 62 77 62 74 58 -weighted sound pressure level L P, d() Performance (Verso R 1 UH data) ir flow rate (m 3 /s),1,2,3,4,5 6 47 247 412 15 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 11,5 13,3 14,5 15,7 16,8 22,7 23,9 25, indoor +22, 1% RH hangeover water heating/cooling exchanger (Hw) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 6,3 6,3 6,3 12, 28 279 277 253 3,5 3,5 3,6 99,7 Temperature in/out, 11,5/22 25/18 22,9 18,8 14,6 15,2 onnection, ½ 282 372 98 1355 15 247 95 412 315 (4x) 372 96 2 282 2 855 6 9 1 1 18 2 ir flow rate (m 3 /h) 253 oes not conform to ErP218 requirements 96 398 315 (4x) ccessories (p. 18) losing damper Water heater X cooler ooling unit / / GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M -HW-3R-15-1,6-W2 W-1,4-9 VVP47.2-4,+SSP61 F-1,4-1 MOU-36HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 9

Verso R 17 U / H / V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 22 1~23 12,9 6,7 8 4 46-M5 43 4,5 / 6,3 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing,1,2,3,4,5,6 6 62 77 62 74 57 -weighted sound pressure level L P, d() Performance (Verso R 17 UH data) 6 9 1 1 18 2 2 ir flow rate (m 3 /h) oes not conform to ErP218 requirements ccessories (p. 18) 46 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 11,2 9, 14,3 15,5 16,7 22,7 23,9 25,1 hangeover water heating/cooling exchanger (HW) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 6,9 6,9 6,9 12,6 34 33 31 2167 1,7 1,7 1,7 12,5 Temperature in/out, 11,2/22 25,1/18 24,9 19,8 14,3 15, onnection, ¾ 27 46 28 indoor +22, 1% RH 286 39 xx4(x) 91 13 39 235.5 1485 1547 282.5 92 27 46 39 91 995 286 losing damper ir heater-cooler X cooler ooling unit H V / / SRU-M-x+LF24/LM24 SRU-M-x+LF24/LM24 STS-IVR3-6--7-S STS-IVR3-6--12-S -HW-3R-15-1,6-W2 W-1,6-11 VVP47.2-4,+SSP61 F-1,6-11 MOU-36HFN6-K8243 xx4(x) Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 1

Verso R U / H / V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 2 21 1~23 16,9 6,3 8 4 46-M5 61 7,5 / 8,3 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing 67 82 67 79 6 -weighted sound pressure level L P, d() Performance (Verso R UH data) 49 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 9,2 11,5 12,9 14,3 15,7 22,9 24,3 25,7 indoor +22, 1% RH hangeover water heating/cooling exchanger (Hw) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 1,7 1,7 1,7 17,7 474 472 47 343 2, 2, 2, 22,7 Temperature in/out, 9,2/22 25,7/18 31,5 25,3 18,8 18,4 onnection, ¾,1,2,3,4,5,6,7 6 8 1 16 2 28 ir flow rate (m 3 /h) oes not conform to ErP218 requirements ccessories (p. 18) 286 39 28 46 27 xx4(x) 91 13 39 235.5 1485 1547 282.5 92 27 46 39 91 995 286 losing damper ir heater-cooler X cooler ooling unit H V / / SRU-M-x+LF24/LM24 SRU-M-x+LF24/LM24 STS-IVR3-6--7-S STS-IVR3-6--12-S -HW-3R-15-2,5-W2 W-2,5-17 VVP45.25-6,3+SS61 F-2,5-17 MOU-55HFN6-K8243 xx4(x) Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 11

Verso R F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, 21 28 1~23 16,9 6,3 56 42 96 58 7,5 / 9,7 5.1 ontrol panel 5.1 coustic data -weighted sound power level L w, d() asing,1,2,3,4,5,6 6 69 79 69 79 6 -weighted sound pressure level L P, d() Performance 49 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15,8 16,9 17,6 18,3 18,9 22,4 23,1 23,8 indoor +22, 1% RH Hot water duct air heater (H)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 4,2 4,2 4,2 185 184 183 9,1 9,1 9,2 Temperature in/out, 15,8/22 16, 13,3 1, onnection, ½ * option 315 (4x) 35 35 121 6 6 1318 8 1 16 2 ir flow rate (m 3 /h) oes not conform to ErP218 requirements 264 26 264 527 223 ccessories (p. 18) Shown as left (L1) losing damper GUJ-M-355+LF24/LM24 Water heater / / GS-355--9-M GS-355--1-M H-355 -HW-3R-15-1-W2 ir heater-cooler X cooler W-2,-13/ HW-355 VVP47.2-4,+SSP61 F-2,-14 outdoor intake supply air extract indoor exhaust air ooling unit MOU-48HFN6-K8243 www.aeria-france.fr 12

VERSO StandaRd New Verso R 2 H Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 28 45 34 1~23 22 11,7 792 392-1 771 7,5 / 7,4 5.1 9 5.1 coustic data -weighted sound power level L w, d() asing 61 79 63 75 6 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),1,2,3,4,5,6,7,8 45 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 1,4 12,5 13,7 15 16,3 22,8 24,1 25,4 indoor +22, 1% RH Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 1,9 1,9 1,9 481 479 477 3,3 3,3 3,3 Temperature in/out, 1,4/22 22,1 17,7 13,2 onnection, ½ Shown as right (R2) 269 269 462 462 618 37 618 7xx4(x) 8 1 16 2 28 3 ir flow rate (m 3 /h) oes not conform to ErP218 requirements ccessories (p. 18) Shown as left (L2) losing damper ir heater-cooler X cooler ooling unit / / SRU-M-7x+LF24/LM24 STS-IVR3-8--7-S STS-IVR3-8--12-S -HW-3R-15-2,5-W2 W-2,5-17 VVP45.25-6.3+SSP61 F-2,5-17 MOU-55HFN6-K8243 outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 13

Verso R U / H / V 3 44 Supply voltage HW, V Maximal operating current HE, 19,8 Maximal operating current HW, 7,1 Filters dimensions H L, mm 525 51 46-M5 ( 2) 688 Electric air heater capacity, kw / t, 9/7,8 ontrol panel 5.1 5.1 coustic data -weighted sound power level L w, d() asing,2,4,6,8 1 6 57 69 65 76 57 -weighted sound pressure level L P, d() Performance (Verso R UH data) 45 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 11,5 13,3 14,5 15,7 16,8 22,7 23,9 25 hangeover water heating/cooling exchanger (HW) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 11,3 11,3 11,3 21,3 499 496 494 366 1,9 1,9 1,9 2,3 Temperature in/out, 11,5/22 25/18 39,9 32,2 24,2 25,1 onnection, 1 33 544 indoor +22, 1% RH 28 323 4 xx4(x) 11 123 1181 6 7 7 328.5 328.5 33 544 4 323 11 1 2 3 ir flow rate (m 3 /h) 11 4 323 4 323 ccessories (p. 18) xx4(x) losing damper ir heater-cooler X cooler ooling unit H V / / SRU-M-x+LF24/LM24 SRU-M-x+LF24/LM24 STS-IVR3-6--7-S STS-IVR3-6--12-S -HW-3R-15-2,5-W2 W-3,-2 VVP45.25-6,3+SS61 F-3,-2-2 2xMOU-36HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 14

VERSO StandaRd New Verso R F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 4 289 19.9 7,1 56 54 96-M5 1167 9 / 6, 5.1 6 5.1 coustic data -weighted sound power level L w, d() asing 71 84 71 84 62 -weighted sound pressure level L P, d() Performance,2,4,6,8 1 1,2 6 51 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 5,4 8,7 1,8 12,9 14,9 23 25 27 indoor +22, 1% RH Hot water air heater (SVK)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 23,4 23,4 23,4 134 129 124 7,6 7,7 7,8 Temperature in/out, 5,4/22 37 3,6 24,2 onnection, 1 * option 1318 33 64 xx4(x) 33 64 121 1 2 3 4 ir flow rate (m 3 /h) 324 648 216 222 324 oes not conform to ErP218 requirements ccessories (p. 18) Shown as left (L1) losing damper Water heater ir heater-cooler X cooler ooling unit / / SRU-M-x+LF24/LM24 STS-IVR3-6--7-S STS-IVR3-6--12-S SVK-8x-2R -HW-3R-2-4,-W2 W-4,-27 VVP45.25-1+SS61 F-4,-27-2 2xMOU-48HFN6-K8243 outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 15

Verso R U / H / V 5 478 Supply voltage HW, V Maximal operating current HE, 31,1 Maximal operating current HW, 9,7 Filters dimensions H L, mm 525 51 46-M5 ( 2) 1371 Electric air heater capacity, kw / t, 15 / 8,2 ontrol panel 5.1 5.1 coustic data -weighted sound power level L w, d() asing 66 85 66 82 59 -weighted sound pressure level L P, d() Performance (Verso R UH data) ir flow rate (m 3 /s),2,4,6,8 1 1,2 1,4 1,6 6 49 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 7,9 1,4 11,9 13,5 15,1 22,9 24,5 26,1 indoor +22, 1% RH hangeover water heating/cooling exchanger (HW) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 24,1 24,1 24,1 33,6 166 16 156 5773 3,1 3,1 3,1 46,1 Temperature in/out, 7,9/22 26,1/18,7 59, 48,2 37,2 33,6 onnection, 1 323 4 4 323 28 544 33 xx4(x) 1181 544 11 33 11 123 6 7 7 328.5 328.5 6 ir flow rate (m 3 /h) oes not conform to ErP218 requirements 11 4 323 4 323 ccessories (p. 18) xx4(x) losing damper ir heater-cooler X cooler ooling unit H V / / SRU-M-x+LF24/LM24 SRU-M-x+LF24/LM24 STS-IVR3-8--7-S STS-IVR3-8--12-S -HW-3R-25-6.3-W2 W-4,5-3 VVP45.25-1+SS61 F-4,5-31-2 2xMOU-55HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 16

VERSO StandaRd New Verso R H Maximal operating current HE, Filters dimensions H L, mm ontrol panel 5 442 13,1 592 592-8 ( 2) 141 5.1 1 5.1 coustic data -weighted sound power level L w, d() asing 65 82 64 8 61 -weighted sound pressure level L P, d() Performance,2,4,6,8 1 1,2 1,4 1,6 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 1,5 12,5 13,8 15,1 16,4 22,8 24,1 25,3 indoor +22, 1% RH Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 2,4 2,4 2,2 93 899 886 5,4 5,4 5,3 Temperature in/out, 1,5/22 37,3 29,1 2,2 onnection, ½ 6 6 34 34 62 62 1 6 ir flow rate (m 3 /h) 1 751 37 751 xx4(x) 1 oes not conform to ErP218 requirements Shown as left (L1) ccessories (p. 18) losing damper ir heater-cooler X cooler ooling unit / / SRU-M-x+LF24/LM24 STS-IVR3---7-S STS-IVR3---12-S -HW-3R-2-4,-W2 W-4,5-3 VVP45.25-1.+SS61 F-4,5-31-2 2xMOU-55HFN6-K8243 outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 17

Verso R 7 H Maximal operating current HE, 68 765 18,1 Filters dimensions H L, mm 592 592-8 635-M5 ( 2) 157 ontrol panel 5.1 1 5.1 coustic data -weighted sound power level L w, d() asing,4,8 1,2 1,6 2 6 61 83 64 83 59 -weighted sound pressure level L P, d() Performance 48 ir flow rate (m 3 /s) Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 1,9 12,9 14,1 15,4 16,6 22,7 24, 25,2 indoor +22, 1% RH Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 25,2 25,2 25,2 1114 119 113 9, 9,2 9,3 Temperature in/out, 1,9/22 56 45,7 35,4 onnection, 1 7 7 72 72 152 125 6 7 8 ir flow rate (m 3 /h) oes not conform to ErP218 requirements 1 751 39 751 Shown as left (L1) 1x6x4(x) ccessories (p. 18) losing damper ir heater-cooler X cooler ooling unit / / SRU-M-1x6+LF24/LM24 STS-IVR3-1-6-7-S STS-IVR3-1-6-12-S -HW-3R-2-4,-W2 W-7,-47 HR3 32 16+M162 F-7,-48-3 3xMOU-55HFN6-K8243 outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 18

Verso F ir handling units with a counterflow plate heat exchanger Sizes of Verso F units ir flow, m³/s,6,8,11,14,17,19,28,55,83 1,11 3 2 17 1 1 6 7 ir flow, m³/h dvantages of Verso F units Heat energy saving In the process of ventilation the heat of the exhaust air is recovered to the supplied air. Totally separated airflows The supply and exhaust airflows are separated, thus making possible utilization of the heat of the extracted foul air. Long term efficient operation The absence of movable parts ensures effective heat exchange and long run. Low noise level Verso F air handling units are equipped with silently operating fans and sound insulation, which ensures low noise level. Efficient fans VERSO units are equipped with the most efficient backward curved impellers and either Ultra Premium IE5 class PM or Super Premium IE4 class E motors. ounter flow aluminium plate heat exchanger factor up to 92% in wet conditions and up to 88% in dry conditions. Heat exchanger is tight, both air flows are separated, use of heat of polluted air is possible. luminium construction is resistant to sea water, it has long service life. There is a build-in bypass with damper for heat recovery regulation and exchanger frost protection. Each unit with plate heat exchanger is equipped with stainless steel sloping drain tray and water trap. nti-frosting protection If the temperature of the exhaust air drops below 4, freezing may occur at the exhaust air corner of the heat exchanger. To avoid free zing the temperature sensor is installed in this zone to give a signal to the automatic control. If for some period of time temperature will not rise up, by-pass damper is opened to redirect outdoor air through by-pass channel and only warm exhaust air flows through exchanger to defrost risky zone. www.aeria-france.fr 19

Verso F range standard equipment possible choice ordered separately Supply / exhaust air filter class ontrol system 5 Unit size Heater ooler Inspection side M5 F7 HE HW HW W X R1 L1 panel 5.1 Verso F U Verso F H / V Verso F F Verso F 1 U Verso F 1 H / V Verso F 1 F Verso F 1 F Verso F 17 U Verso F 17 H / V Verso F 2 U Verso F 2 H / V Verso F 2 F Verso F 3 U Verso F 3 H / V uct connection H horizontal V vertical U universal, 14 installation options F false ceiling Heater HE electric heater. HW water duct heater is installed on the duct and must be ordered separately. Heaters are mounted on the outside of the unit in any userconvenient place....1 V heater control included in automatic control system. HW heater-cooler one for both heating and cooling. Ideal for buildings using geothermal energy. ooler W designed for air cooling using cold water (water-glycol mixture), provides a higher comfort level in rooms. X designed for air cooling using direct expansion cooling unit, provides a higher comfort level in rooms. Inspection side See p. 116 ontrol system 5 ontrol features: 5 different operation modes: omfort1, omfort2, Economy1, Economy2 and Special; Temperature control modes: Supply air / Extract air / Room; Energy parameters indication: thermal efficiency of the heat exchanger, heat exchanger's recovered energy, energy saving indicator; ir quality, minimum temperature control; Flow control modes: V, VV and V; Weekly operating schedule; ir flow indication (m 3 /h, m 3 /s, l/s); Rotary or plate heat exchanger failure protection; Rotary heat exchanger cleaning and warm-up function; Intelligent self-diagnostic; night cooling; ir quality function; Supply air temperature control; Min. supply air temperature maintenance; ombined water heater & cooler control; Inverter-type X outdoor unit control; ooling recovery function; Outdoor compensated ventilation; Humidity control: air humidification and dehumidification*; irculation pumps control by demand; Warm-up function of circulation pumps and mixing valves; ir filter clogging indication; Operation hours and energy counters; Remote control via web interface; uilt-in data logger for all air handling unit parameters; pplication software for smartphones based on ndroid and ios. * additionally ordered function. www.aeria-france.fr 2

Verso F U / H / V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 1 225 1~23 9,5 3,3 8 46-M5 165 4,5 / 11,9 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing,5,1,15,2,25,3 56 73 56 73 53 -weighted sound pressure level L P, d() Performance 6 8 1 ir flow rate (m 3 /h) 42 242 421 285 372 181 196 253 134 242 95 421 372 91 965 285 91 398 ir flow rate (m 3 /s) 15 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15,9 16,3 16,9 17,6 18,2 22,6 23,7 24,9 indoor +22, 1% RH hangeover water heating/cooling exchanger (Hw) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 2, 2, 2, 6,6 9 9 89,5 1139 1,7 1,7 1,8 33,3 Temperature in/out, 15,9/22 24,9/18 13,5 1,8 8,2 1,2 onnection, ½ vailable versions: 1) Electric air heater (HE) 2) hangeover water heating/cooling exchanger (HW) 98 253 315 (4x) 315 (4x) ccessories (p. 18) losing damper Water heater X cooler ooling unit / / GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M -HW-3R-15-,63-W1 W-,7-5 VVP47.15-2,5+SSP61 F-,7-5 MOU-18HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 21

Verso F F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 173 1~23 7,3 3,3 5 42 46-M5 171 3 / 8,3 5.1 5.1 coustic data -weighted sound power level L w, d() asing 61 76 61 77 57 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),5,1,15,2,25,3 6 46 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 16,1 16,5 17, 17,6 18,3 22,6 23,7 24,9 indoor +22, 1% RH Hot water duct air heater (H)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 2, 2, 2, 87 87 86 3,2 3,2 3,2 Temperature in/out, 16,1/22 9,9 8, 6, onnection, ½ * option 1 275 5 315 (4x) 275 5 121 6 8 1 ir flow rate (m 3 /h) 527 263 15 16 1795 263 ccessories (p. 18) losing damper / / Water heater ir heater-cooler X cooler ooling unit GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M H-315 -HW-3R-15-1-W2 W-,9-6 / HW-315 VVP47.15-2,5+SSP61 F-,9-6 MOU-18HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 22

Verso F 1 U/H/V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 1 225 1~23 11,7 5,5 8 46-M5 26 4,5 / 8,9 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing 62 8 62 8 58 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),5,1,15,2,25,3,35,4 6 47 285 372 315 (4x) 372 285 242 242 421 95 421 6 8 1 1 16 ir flow rate (m 3 /h) 181 196 253 134 91 965 91 398 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15,3 15,8 16,5 17,2 18, 22,7 23,8 25, indoor +22, 1% RH hangeover water heating/cooling exchanger (Hw) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 2,9 2,9 2,9 9,3 129 128 128 1 2, 2, 2, 61,3 Temperature in/out, 15,3/22 25/18 16,7 13,5 1,2 12,8 onnection, ½ vailable versions: 1) Electric air heater (HE) 2) hangeover water heating/cooling exchanger (HW) 98 15 oes not conform to ErP218 requirements 253 315 (4x) ccessories (p. 18) losing damper Water heater X cooler ooling unit / / GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M -HW-3R-15-1-W2 W-1,4-9 VVP47.2-4,+SSP61 F-1,4-1 MOU-36HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 23

Verso F 1 F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 1 175 1~23 11,7 5,5 5 42 46-M5 31 4,5 / 9,6 5.1 5.1 coustic data -weighted sound power level L w, d() asing 64 8 64 8 58 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),5,1,15,2,25,3,35,4 6 47 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15,5 16, 16,6 17,3 18, 22,6 23,8 25, indoor +22, 1% RH Hot water duct air heater (H)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 2,8 2,8 2,8 125 125 124 4,9 4,9 4,9 Temperature in/out, 15,5/22 11,8 9,5 7,2 onnection, ½ * option 315 (4x) 1 275 5 275 5 121 6 8 1 1 16 ir flow rate (m 3 /h) 527 263 15 16 1795 263 oes not conform to ErP218 requirements ccessories (p. 18) losing damper / / Water heater GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M H-315 -HW-3R-15-1-W2 Shown as left (L1) ir heater-cooler X cooler ooling unit W-1,4-9 / HW-315 VVP47.2-4,+SSP61 F-1,4-1 MOU-36HFN6-K8243 outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 24

Verso F 1 F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 16 19 1~23 12,9 6,7 5 42 46-M5 42 4,5 / 7,8 5.1 5.1 coustic data -weighted sound power level L w, d() asing 62 76 61 76 58 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),1,2,3,4,5 6 48 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15, 15,6 16,2 17, 17,8 22,7 23,9 25,1 indoor +22, 1% RH Hot water duct air heater (H)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 3,8 3,8 3,8 165 165 164 7,3 7,3 7,4 Temperature in/out, 15,/22 13,5 1,8 8,2 onnection, ½ * option 1 275 5 315 (4x) 275 5 121 6 9 1 1 18 ir flow rate (m 3 /h) 527 263 15 16 1795 263 oes not conform to ErP218 requirements ccessories (p. 18) losing damper / / Water heater ir heater-cooler X cooler ooling unit GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M H-315 -HW-3R-15-1-W2 W-1,6-11/HW-315 VVP47.2-4,+SSP61 F-1,6-11 MOU-36HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 25

Verso F 17 U/H/V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 17 243 1~23 12,9 6,7 8 46-M5 465 4,5/7,4 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing 6 77 59 77 59 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),1,2,3,4,5 6 49 242 421 285 372 242 95 421 372 285 6 9 1 1 18 2 ir flow rate (m 3 /h) 181 196 253 134 91 965 91 398 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 14,7 15,3 16,1 16,8 17,7 22,7 23,9 25,2 indoor +22, 1% RH hangeover water heating/cooling exchanger (HW) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 4,2 4,2 4,2 11,5 184 183 182 1971 2,4 2,4 2,4 96 Temperature in/out, 14,7 / 22 25,2 / 18 2,7 16,7 12,6 14,5 onnection, ½ vailable versions: 1) Electric air heater (HE) 2) hangeover water heating/cooling exchanger (HW) 98 315 (4x) 15 oes not conform to ErP218 requirements 253 315 (4x) ccessories (p. 18) losing damper Water heater X cooler ooling unit / / GUJ-M-315+LF24/LM24 GS-315--9-M GS-315--1-M -HW-3R-15-1,6-W2 W-1,6-11 VVP47.2-4,+SSP61 F-1,6-11 MOU-36HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 26

Verso F 2 U/H/V Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 2 2 1~23 16,8 6,3 8 46-M5 64 7,5 / 8,7 5.1 8 5.1 coustic data -weighted sound power level L w, d() asing 63 81 63 81 61 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),1,2,3,4,5,6,7,8 6 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15,1 15,8 16,1 16,9 17,8 22,5 23,4 24,3 indoor +22, 1% RH hangeover water heating/cooling exchanger (Hw) Water temperature in/out, 8/6 7/ 6/4 7/12 apacity, kw 5,1 5,1 5,1 14,2 225 224 223 2439 2,8 2,8 2,8 134,8 Temperature in/out, 15,4/22 24,3/18 25,3 2,3 15,3 16,7 onnection, ½ vailable versions: 1) Electric air heater (HE) 2) hangeover water heating/cooling exchanger (HW) 262 398 398 262 1 2 ir flow rate (m 3 /h) oes not conform to ErP218 requirements 15 416 239 xx4(x) 91 935 43 2 281 26 1438 95 416 239 91 965 ccessories (p. 18) losing damper ir heater-cooler X cooler ooling unit H V / / SRU-M-x+LF24/LM24 SRU-M-x+LF24/LM24 STS-IVR3-6--7-S STS-IVR3-6--12-S -HW-3R-15-1,6-W2 W-2,5-17 VVP45.25-6,3+SS61 F-2,5-17 MOU-55HFN6-K8243 Shown as left (L1) xx4(x) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 27

Verso F 2 F Supply voltage HW, V Maximal operating current HE, Maximal operating current HW, Filters dimensions H L, mm Electric air heater capacity, kw / t, ontrol panel 26 34 1~23 16,9 6,3 888 42 96-M5 67 7,5 / 8, 5.1 62 coustic data -weighted sound power level L w, d() asing 64 83 64 83 62 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),1,2,3,4,5,6,7 7 6 51 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15,5 16, 16,6 17,3 18, 22,6 23,8 25, indoor +22, 1% RH Hot water air heater (SVK)* Water temperature in/out, 8/6 7/ 6/4 apacity, kw 5,7 5,7 5,7 251 249 248 3,7 3,7 3,8 Temperature in/out, 15,5/22 21,7 17,4 13, onnection, ½ * option 8 1 16 2 28 ir flow rate (m 3 /h) oes not conform to ErP218 requirements 7xx4(x) 245 ccessories (p. 18) losing damper / / Water heater ir heater-cooler X cooler ooling unit SRU-M-7x+LF24/LM24 STS-IVR3-8--7-S STS-IVR3-8--12-S SVK-7x-2R -HW-3R-15-1-W2 W-2,5-17 VVP45.25-6,3+SS61 F-2,5-17 MOU-55HFN6-K8243 28 264.5 18 528 191 Shown as left (L1) outdoor intake supply air extract indoor exhaust air 263.5 www.aeria-france.fr 28

Verso F 3 U/H/V 3 Supply voltage HW, V Maximal operating current HE, 19,8 Maximal operating current HW, 7,1 Filters dimensions H L, mm 525 51 46-M5 ( 2) 851 Electric air heater capacity, kw / t, 9 / 7,1 ontrol panel 5.1 5.1 coustic data -weighted sound power level L w, d() asing 56 79 57 78 55 -weighted sound pressure level L P, d() Performance ir flow rate (m 3 /s),2,4,6,8 1 1,2 1 2 3 4 ir flow rate (m 3 /h) oes not conform to ErP218 requirements 44 Outside temperature, -23-15 -1-5 25 3 35 fter heat exchanger, 15, 15,7 16,1 16,9 17,8 22,5 23,4 24,4 33 544 indoor +22, 1% RH Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 8,2 8,2 8,2 363 361 36 3, 3,1 3,1 Temperature in/out, 15,/22 3,2 24,1 18, onnection, ¾ 28 323 4 xx4(x) 11 12 1181 11 4 323 7 7 329 329 4 323 4 323 33 544 11 ccessories (p. 18) xx4(x) losing damper ir heater-cooler X cooler ooling unit H V / / SRU-M-x+LF24/LM24 SRU-M-x+LF24/LM24 STS-IVR3-8--7-S STS-IVR3-8--12-S -HW-3R-15-2,5-W2 W-4,-27 VVP45.25-6,3+SS61 F-4,-27-2 2xMOU-48HFN6-K8243 Shown as left (L1) outdoor intake supply air extract indoor exhaust air www.aeria-france.fr 29

Verso S False ceiling supply air handling units Sizes of Verso S units ir flow, m³/s,6,8,11,14,17,19,22,28,55,83 1,11 2 1 6 7 8 ir flow, m³/h dvantages of Verso S units Height is only 297 mm / 3 mm / 545 mm easy to choose the place for installation. Units are complemented with fastening profiles and vib ration absorbing holders. Safe and handy design of removable cover ensures easy fi xing of cover at different opening levels for perfor ming maintenance and service inspection. ir handling units have integrated control system. ontrol panel may be installed in any user-convenient place. ontrol panel display enables to set the operation para meters of the unit and monitor them. There is a possibility to complement and control the duct mounted cooling section. Verso S range standard equipment possible choice ordered separately Supply/exhaust air filter class Inspection side ontrol system 5 Heater ooler Unit size M5 F7 HE HW W X R1 panel 5.1 Verso S 1 F Verso S 2 F Verso S F uct connection F false ceiling Heater HE electric heater HW water air heater Inspection side See p. 116 ooler W designed for air cooling using cold water (water-glycol mixture), provides a higher comfort level in rooms. X designed for air cooling using direct expansion cooling unit, provides a higher comfort level in rooms. ontrol system More information about 5 on p. 8. www.aeria-france.fr 3

Verso S 1 F Filters dimensions H L, mm at reference flow rate, W ontrol panel 1 46 558 287 46-M5 3 5.1 5.1 2 (2x) 3 152 coustic data -weighted sound power level L w, d() 893 925 7 3 74 asing 8 56 Technical data -weighted sound pressure level L P, d() Supply air handling unit Supply voltage, V ir heater capacity, kw Maximal operating current, ΔT, 46 Verso S 1 F-HE/9 9, 15,7 19,2 Verso S 1 F-HE/15 15, 24,4 32,1 Verso S 1 F-HW 1~23 2,9 Performance ir flow rate (m 3 /s),5,1,15,2,25,3,35,4 6 6 9 1 1 ir flow rate (m 3 /h) * ompliance to ErP218 requirements check with the selection program. Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 1,1 8,4 6,5 448 369 286 3,3 2,8 2,3 Temperature in/out, -5 / 18,2-5 / 14,2-5, / 1, 1,1 8,4 6,5 onnection, ½ ccessories (p. 18) losing damper ir heater-cooler X cooler ooling unit GUJ-M-2+LF24/LM24 GS-2--6-M GS-2--9-M -HW-3R-15-2.5-W2 W-1,4-9 VVP47.2-4,+SSP61 F-1,4-1 MOU-36HFN6-K8243 www.aeria-france.fr 31

Verso S 2 F Filters dimensions H L, mm at reference flow rate, W ontrol panel 19 73 858 287 46-M5 34 5.1 5.1 7x2x2(x) 3 152 coustic data -weighted sound power level L w, d() 893 953 7 asing 75 52 Technical data -weighted sound pressure level L P, d() Supply air handling unit Supply voltage, V ir heater capacity, kw Maximal operating current, ΔT, 42 Verso S 2 F-HE/15 15, 24,7 21,9 Verso S 2 F-HE/22,5 22,5 35,6 32,9 Verso S 2 F-HW 1~23 3,3 Performance ir flow rate (m 3 /s),1,2,3,4,5,6 8 1 16 2 ir flow rate (m 3 /h) * ompliance to ErP218 requirements check with the selection program. Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 17, 14,4 11,7 752 632 511 7,5 5,9 4,5 Temperature in/out, -5,/21,7-5,/17,5-5,/13,3 17, 14,4 11,7 onnection, ½ ccessories (p. 18) losing damper ir heater-cooler X cooler ooling unit SRU-M-7x2+LF24/LM24 STS-IVR3-8-2-7-S STS-IVR3-8-2-12-S -HW-3R-15-2.5-W2 W-2,-13 VVP47.2-4,+SSP61 F-2,-14 MOU-48HFN6-K8243 www.aeria-france.fr 32

Verso S F Filters dimensions H L, mm at reference flow rate, W ontrol panel 125 4 48 92-M5 ( 2) 5.1 5.1 129 6xx2(x) 555 coustic data 2 -weighted sound power level L w, d() 116 1227 115 7.5 71 asing 8 52 Technical data -weighted sound pressure level L P, d() Supply air handling unit Supply voltage, V ir heater capacity, kw Maximal operating current, ΔT, 41 Verso S F-HW 2,7 Performance ir flow rate (m 3 /s),2,4,6,8 1 6 1 2 3 ir flow rate (m 3 /h) * ompliance to ErP218 requirements check with the selection program. Hot water air heater Water temperature in/out, 8/6 7/ 6/4 apacity, kw 32,6 32,6 32,6 1442 1435 1429 4,5 4,5 4,5 Temperature in/out, -5/22-5/22-5/22,2 42,5 34,7 onnection, 1 ccessories (p. 18) losing damper ir heater-cooler X cooler ooling unit SRU-M-6x+LF24/LM24 STS-IVR3-6--7-S STS-IVR3-6--12-S -HW-3R-25-6.3-W2 W-3,-2 VVP45.25-6,3+SS61 F-3,-2-2 2xMOU-36HFN6-K8243 www.aeria-france.fr 33

VERSO Pro Heat recovery units casing is comprised of three main sections. Two side sections are similar fan and filter sections. The middle section is for a heat exchanger. Supply air unit casing is composed of symmetrical filter and fan sections. For customer convenien ce air heaters, cooler sections are mounted outside the unit. HU N : 7.9.356 Range: VERSO ir flow.28 1.39 2.78 4.17 5.56 6.94 8.33 9.72 11.11 m 3 /s 9 8 7 6 4 3 2 Verso S Verso P Verso F Verso R ErP 218 1 1 5 1 15 2 25 3 35 4 m 3 /h www.aeria-france.fr 34

dvantages onvenient Unit design assures effective transportation and easy installation. Separate parts are compact, without projection parts; therefore it is easy to transport them to a designa ted area of the building, where later they are assembled. Fi nished air handling units are delivered to the customer in packages that are ready to be transported. urable Unit doors are mounted with firm and aesthetic-looking hinges and are locked with convenient and elegant locks. oor seals are made of firm and elastic foam type gaskets, which are automatically fastened to the door by the newest machinery and are long lasting and hermetic. Universal Unit walls are made of galvanized steel sheets with mm thickness insulation. This assures not only effective heat and noise insulation, but also a high level of fire resistance. ir handling unit accessories external grilles for supply/exhaust vents, hood and roof allow installing units outside. On request units may be painted customer desired color. User friendly Filters, fans, heat exchangers, coolers and other components are easily accessible during use; if necessary, they can be easily replaced. new filter clamping mechanism, not only assures tightness, but also essentially simplifies filter change procedure. esign Rotary heat exchanger Used in Verso R series units. factor up to 85 %. Possible wave height: 1,4 mm; 1,5 mm, 1,7 mm. Types of rotary heat exchangers: ondensation (aluminium); Enthalpy (aluminium and zeolith); Sorption (aluminium with zeolith coating); eep epoxy coating lygold technology. luminium foil is made of an aluminium alloy resistant to sea water. Rotary heat exchanger rotation speed is controlled by a frequency converter, according to the air temperature. The heat exchanger can be ordered with an installed purge section. ounter flow plate heat exchanger Used in Verso F series units. factor up to 92 % in wet conditions and up to 88 % in dry conditions. The plate heat exchanger is equipped with automatic by-pass. luminium plates are made of an aluminium alloy resistant to sea water. Plate heat exchanger Used in Verso P series units. factor up to 75 % in wet conditions and up to 73 % in dry conditions. luminium plates are made of an aluminium alloy resistant to sea water. www.aeria-france.fr 35

Heat exchangers VERSO air handling units may generate different energy efficiency levels with four main types of heat exchangers. The most advanced one is a rotary heat exchanger with the thermal efficiency of 85 % and the minimum risk of freezing. counter cross-flow plate heat exchanger and a double plate heat exchanger are also highly effective and may have efficiency coefficients up to 92 % or 82 % correspondingly, however, they are very sensitive to low outdoor temperatures. standard plate heat exchanger complete the range of the heat exchangers with the maximum efficiency of 73 %. luminium is used as a material for the exchangers. nti-frost precautions Under conditions when the outdoor air temperature is low and humidity is high, the risk of heat exchanger frosting may appear. To avoid frosting of the heat exchanger bypass damper is opened. For an extremely low outdoor air temperature the duct mounted electric preheater is recommended. The counter cross-flow heat exchanger is even more sensitive for low outside air temperatures, as the risk of frosting appears in the temperature range from -3 to -5 and below. standard aluminium cross-flow plate heat exchanger has better features, as the risk of freezing appears only at -1. s an option, you can choose the latest effective protection from icing of the counterflow heat exchanger "3+1". The essence of this system is that even after the icing starts, 2/3 of the heat exchanger surface area works efficiently. The lo west risk and the highest resistance to cold outside air is a competitive feature of the rotary heat exchanger, as it does not freeze even at the temperatures of -3 if the humi dity level of the air is appropriate. Fans In VERSO series units plug type fans are used, therefore, units are silent and use electricity effectively. The fans are balanced statically and dynamically, based on the ISO 194 standard; therefore, unit vibration is minimal and meets all requirements. When running, fans exhibit the following qualities: Very high efficiency coefficient Frequency converters ensure an optimal capacity Good acoustic performance Longevity: a fan is directly connected to the electric motor, therefore, there is no a belt gear that simplifies maintenance. There is a possibility to install an air flow measuring device Two types of fan motors are available three-phase permanent magnet synchronous motors (PM) ( V, Hz), controlled by frequency converters, or electronically commutated (E) with an integ rated electronic controller with 2 % speed regulation. Safety category IP55 according to IE 34-5. Windings insulation category F. Maximum operating temperature is 4. n aluminium or high performance composite impeller has less weight and vibration force on motor bearings. new design of the impeller can reach up to 79 % of static efficiency. PM and E fans Highly efficient in all operating areas, PM and E motors are available in all types of VERSO PRO units. High efficiency is determined by low energy consumption, high efficiency and the best values of SFP factor. PM type motors correspond to the Ultra Premium Efficiency lass IE5 and ensure high efficiency in a wide operation range with reliable performance, durability, relatively low cost and electrical stability. Their operation is extremely smooth and silent, ensuring the highest efficiency, energy saving and accuracy in operation. E type motors correspond to the Premium Efficiency lass IE4, have integrated motor controller, and ensure high operation efficiency, smooth and energy saving operation in all working points. oth types of motors have long-life operation feature and guarantee the highest level of operation. www.aeria-france.fr 36

ir heaters Water air heaters Normally used with aluminium fins and copper pipes. an be made with a thread joint to connect a freezing sensor. Insulated with a mineral wool heater section mounted on the outside of the unit room space is saved this way; it is also more convenient to mount it. Maximum operating pressure 21 bars Maximum water temperature + (on special order up to +13 ) Heated air temperature up to +4 Electric air heaters Stainless steel heating elements are used in production. three level protection ensure protection from over heating. Protection class IP54 in accordance with IE 34-5. Heated air temperature up to +4. Note: exact electric air heater measurements and other information can be found in VERSO air handling units selection software. The electric heater has its own supply voltage. ir coolers Water air coolers Normally used with aluminium fins (spacing 2,5 or 3 mm) and copper pipes. Insulated with a mineral wool heater section mounted on the outside of the unit room space is saved this way and it is more convenient to mount it. Maximum operating pressure 21 bars. The air cooler section is assembled with a stainless steel sloping drain tray and a water trap. irect evaporation air coolers Normally used with aluminium fins (spacing 2,5 or 3 mm) and copper pipes. Insulated with a mineral wool heater section mounted on the outside of the unit room space is saved this way; it is also more convenient to mount it. Maximum operating pressure 42 bars. The cooler section is assembled with a stainless steel slo ping drain tray and a water trap. The power of the direct evaporation air cooler can be divided into 2 or 3 steps. It is necessary to indicate this upon order. X coil also can operate in heating mode. lygold anti-corrosion treatment The lygold Polul XT anti-corrosion treatment is a revolutionary treatment for coils, which will stop corrosion and capacity loss of your equipment. lygold Polul XT carries a guarantee of 5 years, provided that the recommended cleaning protocol is maintained. This gives you the guarantee that your coil is in optimal condition resulting in lower running costs and a longer coil life. lygold Polul XT is an anti-corrosion treatment consisting of a conversion layer followed by a polyurethane top coat. The operating temperature range is -2 to 1. There is no loss of heat transfer performance and only a minimal change in air pressure drop. The lygold treatment can be applied to cooling and X coils, run around coils, heating coils and heat pipes. reas of application may include: industrial, commercial, medical, process, marine etc. To counteract the possibility of corrosion it is current practice to specify either thicker fin material or higher specification material such as copper. With lygold there is significant potential for reducing the overall weight of the coil in addition to corrosion protection. lygold Polul XT impact on coil lifetime: luminum pigmentation for heat conducting % penetration due to high air volumes UV resistance: excellent Flexible Excellent adhesion Thin layer to prevent pressure drop Filling and sealing fin-tube spacing High mechanical resistance www.aeria-france.fr 37

ir dampers losing air dampers installed in the air handling units are produced from aluminium with rubber sealing. onnectors L2. For unit sizes 6, 7, 8 L3, 9 L4. ampers are located outside the unit; they can be made with an insulated damper casing. Standard tightness lass 2, it possible to order higher tightness lass 4 or higher thermal insulation lass 2 T. Noise reduction sections To avoid excessive pressure losses inside the air hand ling unit, duct mounted sound attenuation sections are offered for VERSO units. The sound attenuation section of 9 mm length will reduce the noise to air ducts by 15 to 2 d, a longer section of 1 mm in length by 2 to 25 d. The width and height of these sections correspond to air handling unit dimensions. The baffler-type sound absorber is installed inside this section. afflers are filled with special acoustic mineral stone wool and are covered by non-woven glass fibre felt certified to be inside the air duct. Mineral wool can be replaced with polyester wool in the case of a special request. Splitters of the absorber can be easily removed from the section for dry or semi-wet washing for ventilation hygiene purposes. The efficiency of the channel noise reduction section, in d ir filters From G4 to F9 class synthetic or fiberglass pocket type filters are used. Standard length of G4 class filters 36 mm. Standard length of M5 F9 class filters, 635 mm. The filter clamping mechanism ensures tightness and simp lifies a filter replacement procedure. lso G4 or M5 prefilter can be selected on supply air flow. No. 1 2 3 4 6 7 8 9 Ilgis, Efficiency d when frequency Hz mm 63 125 2 8 9 1 19 27 31 33 32 27 17 1 13 26 35 42 44 43 36 22 9 6 13 17 21 22 21 18 11 1 8 17 23 27 29 28 24 15 9 7 13 18 22 23 22 19 12 1 9 18 24 29 3 3 25 15 9 6 13 18 21 22 21 18 11 1 8 17 23 27 29 28 24 15 9 6 12 17 2 21 21 18 11 1 8 16 22 27 28 27 23 14 9 8 15 21 25 26 25 21 13 1 1 2 28 33 34 34 28 18 9 7 14 2 23 25 24 2 13 1 1 19 26 31 33 32 27 17 9 7 14 19 23 24 23 2 12 1 9 18 25 3 32 31 26 16 9 7 14 2 23 25 24 2 13 1 1 19 26 31 33 32 27 17 www.aeria-france.fr 38

asing and outside grilles asing and outside grilles can be additionally mounted on the supply and exhaust vents of outdoor air handling units. Roof roof with water drainage must be additionally installed on outdoor air handling units. Height adjustable feet The construction frame of the air handling unit with height adjustable feet makes it much easier to level the unit on the site. oor locks and handles Easy to use door locks and handles ensure safe unit maintenance. Inspection window and lighting Internal lighting enables to observe unit s internal operation through inspection window. Economy light is used with switch outside the unit. Inspection window enables to observe unit s internal operation. The diameter of plastic window is mm. www.aeria-france.fr 39