Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Similar documents
Use. The burner controls are certified to EN 230 and EN 298.

Burner Controls. Building Technologies HVAC Products

Gas Burner Controls. Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Burner controls. Building Technologies HVAC Products

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies HVAC Products

LGA... Gas Burner Controls. Building Technologies Division

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

LAE10 LFE10. Use. Series 02

Flame Safeguards LFE10. Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

Flame Safeguards LFE10. Building Technologies HVAC Products

Oil Burner Controls LOA3... Building Technologies Division

UV Flame Supervision System

C Note! LGI16... Burner Controls. Building Technologies

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Burner Management System

Infrared Flame Detectors

LFL Series Burner Flame Safeguard Control

EUROBOX SERIES TYPES CM... SM... MM...

Product Range Overview

Burner Management System

QRA10... QRA53... QRA55...

Flame detector. The QRA4.U is for use with the following types of burner control:

Building Technologies Division

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. Building Technologies Division Infrastructure & Cities Sector

EUROFLAT SERIES TYPES C... S... M...

QRA10... QRA53... QRA55...

Building Technologies

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

EUROBOX SERIES TYPES CM...N SM...N MM...N

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Program module for burner control LME71.000

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Basic unit with integrated air-fuel ratio control for forced draft burners

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Burner Management System

Infrared Flame Detectors

Forced draught gas burner

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

MMG Gas burner safety control

MMI (40-34) Gas burner safty control

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

QRA10... QRA53... QRA55...

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

MICROFLAT SERIES TYPES C.../U T X

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

Advanced Ultraviolet Burner Controller

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Gas burner automatic safety control MMI / 811.1

Forced draught gas burner

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

BGH Series Hot Surface Ignition Control

SGU 930 SGU 930i. Control box

DATASHEET. Burner control unit FDA 601x

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

TWO STAGE HEAVY OIL BURNERS

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

Gas Burner Safety Control DMG 970

24 VAC Intermittent Pilot Gas Ignition Control

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Blue-flame Detectors

24 VAC Direct Spark Gas Ignition

MBCE-110/230UV Flame Sensor Module

Operating Manual MS220KA and MSR220KA

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Interrupted Ignition Series Oil Primary Control

Part 3 Troubleshooting

Eclipse Trilogy Flame Safeguard Modulating Sequences

Burner control unit BCU 370

Burner control unit BCU 370

MANUAL OF - INSTALLATION - OPERATION - MAINTENANCE LIGHT OIL BURNERS G4 - G6 G10 - G18 SINGLE STAGE

Monitoring Devices 11/1

Light oil - kerosene burner

AUR300C. Advanced Ultraviolet Burner Controller

UV - flame detector dual fuel burners for intermittent burner operations

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

BC-R10 Series. Burner Controllers

Instruction Manual. Electronic gas and smoke detector GRM

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

BOSCH CONDENS 5000W ZSB18-2A

Eclipse 90 UV Scanner Model A Version 1

Transcription:

7 2 SO 900 Burner Controls Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation. The burner controls are certified to E 230 and E 298. They carry the CE mark based on the directives for gas-fired appliances and electromagnetic compatibility. The and this data sheet are intended for use by OEs which integrate the burner controls in their products! Use Burner controls are used for the startup and supervision of single- or two-stage gas or gas / oil burners in intermittent operation. The flame is supervised with a detector electrode or a UV detector QRA... (with auxiliary unit AGQ2...A27). G2... / G22... in the same type of housing replace their predecessors GB2... / GB22... (refer to «Type summary») and, using the respective adapters, their predecessors F7... and F... (refer to «Replacement types» under «Ordering»). Application-specific features Detection of undervoltages Air pressure supervision with functional check of the air pressure monitor during startup and operation Electric remote reset ndication of error code and flame signal by means of EDs in the lockout reset button Precise program times owing to digital handling of signals Available versions G2... / G22... G25... For unlimited burner capacities (output on startup 0 kw) ockout in the event of flame failure during operation For burner capacities 0 kw Three repetitions in the event of flame failure during operation andis & Staefa CC72E June 5, 998 /

Warning notes To avoid personal injury, damage to property or the environment, the following warning notes must be observed! are safety devices. t is therefore not permitted to open, interfere with or modify the units! The unit must be completely isolated from the mains supply before performing any work in the connection area of the Check the wiring and all safety functions! Risk of explosion Protection against electric shock hazard on the unit itself and on all electrical connections must be ensured through appropriate mounting! Press lockout reset button / operating button only manually (applying a force of 0 ), without using any tools or pointed objects! The connecting wires of the air pressure monitor must be checked for short-circuits! Engineering notes ounting notes nstallation notes Check the electromagnetic compatibility with adjacent components! On applications with actuators, no position feedback signal is delivered to the burner control. The running times of the actuators must be matched to the burner control's program. An additional safety check of the burner with actuator must be made! The relevant national safety regulations must be complied with! gnition and detector electrode must be located such that arcing over of the ignition spark to the detector electrode cannot occur! Risk of electric overloads nstallation and commissioning work may only be carried out by qualified personnel! Observe the permissible length and shielding of the detector lines! Refer to «Technical data» gnition cables must always be run separate from the unit and other cables while observing the greatest possible distances! Check wiring carefully before putting the burner control into operation! Switches, fuses, earthing, etc., must be installed in compliance with local regulations! The earthing lug in the plug-in base must be secured with a screw and a lockwasher or similar! The connection diagrams shown apply to burner controls with earthed neutral. n the case of ionization current supervision in networks with non-earthed neutral, terminal 2 must be connected to the earth conductor via an RC unit (part no. ARC 668 9066 0)! The maximum permissible switching capacity of the connection terminals may not be exceeded! o external mains voltage may be fed to the burner control's control outputs. When checking the functioning of devices controlled by the burner control (gas valves, etc.), the burner control may never be plugged in! n the case of burners with no fan motor, an AGK25 must be connected to terminal 3 of the burner control, or else the burner cannot be started! For safety reasons, it is absolutely essential to feed the neutral wire to the neutral distributor in the plug-in base, or to terminal 2, and from there to the different devices (fan, ignition transformer and gas valves), or to an external neutral distributor! Example 2 3 7 5 72a6/0398 2/ CC72E June 5, 998 andis & Staefa

Electrical connection of ionization current and UV detectors t is important to achieve practically loss-free signal transmission. The length of the detector cable should not exceed 20 m The detector cable may not be run together with other cables ine capacitance reduces the magnitude of the flame signal Use separate cables nsulation resistance Between detector electrode and ground minimum 50 Ω Soiled detector electrode holders support creepage currents which reduce the flame signal The burner must be earthed in compliance with the regulations; earthing of the boiler alone is not sufficient Observe the polarity Burner controls detect wrong polarity of live and neutral, in which case they initiate lockout at the end of «T» echanical design Burner controls Plug-in base Type summary Type of flame detector Type reference Plug-in design according to predecessor type GB2... (refer to «Dimensions») Housing made of impact-proof, heat-resistant plastic Housing accommodates the - control of the microcontroller - electronic flame signal amplifier - lockout reset button with integrated red fault indication lamp and green flame signal lamp ade of impact-proof, heat-resistant plastic Available with screw terminals AGK Cable entry optionally - from the front or laterally by means of cable gland holders AGK65 or cable holders AGK66 - from below through two holes of 6.2 mm dia. Provided with catches on the two narrow sides which engage in the housing of the burner control - must audibly click when the is plugged in - to disengage, a screwdriver must be slightly tilted in the appropriate guiding slots, then the burner control slightly lifts For length and width of plug-in base and positions of fixing holes, refer to «Dimensions» The type references contained in the following table refer to with no plug-in base and with no flame detector. For ordering information on bases and other accessories, refer to «Ordering». Approval to EEC directives tw s max. t s min. T s max. Burner controls for pre-purging with low flame air volume, without actuator control t3n s appr. t3 s appr. t s appr. t0 s min. t s ¹) max. t s ¹) max. Behavior in the event of flame failure during Detector electrode () G2.30A27 2)3) E298 / 230 8 7 3 2.6 2 8 5 - - ockout or G2.230A27 ) 3) E298 / 230 8 20 3 2.6 2 8 5 - - ockout UV detector QRA... G2.330A27 ) 3) E298 / 230 8 30 3 2.6 2 8 5 - - ockout with G2.350A27 )7) E298 / 230 8 30 5.6 2 0 5 - - ockout AGQ2...A27 G2.550A27 ) E298 / 230 8 50 5.6 2 0 5 - - ockout Burner controls for pre-purging with nominal air volume, with actuator control Detector electrode () G22.30A27 2) 3) E298 / 230 8 7 3 2.6 3 8 3 ockout or G22.230A27 ) 3) E298 / 230 8 20 3 2.6 3 8 3 6.5 6.5 ockout UV detector QRA... G22.233A27 E298 / 230 8 20 3 2.6 3 8 3 30 30 ockout with G22.330A27 3)) E298 / 230 8 30 3 2.6 3 8 3 ockout AGQ2...A27 G22.330A270 )5) E298 / 230 8 30 3 2.6 3 8 3 ockout Burner controls for pre-purging with low flame air volume, without actuator control Detector electrode () G25.230A27 3) E298 / 230 8 20 3 2.6 2 8 5 - - max. 3 repetitions or G25.330A27 E298 / 230 8 30 3 2.6 2 8 5 - - max. 3 repetitions UV detector QRA... G25.350A27 E298 / 230 8 30 5.6 2 0 5 - - max. 3 repetitions with AGQ2...A27 egend tw Waiting time t nterval «-» or «-R» t Checked pre-purge time t0 Specified time for air pressure signal T gnition safety time t Programmed opening time for actuator t3 Pre-ignition time t Programmed closing time for actuator t3n gnition time during «T» ) aximum running time available for actuators ) Also suited for use with direct fired air heaters 2) Also suited for use with flash-steam generators 5) Without integral fuse; use only in connection with bases 3) On request, also available for AC 00...0 V, in which case the last two digits read...7 in place of...27 AGK86... or with an external microfuse of max. 6.3 A, (slow) andis & Staefa CC72E June 5, 998 3/

Ordering Burner control refer to «Type summary» Flame detectors Detector electrode delivered by others UV detector QRA... refer to data sheet 77 Plug-in base with screw terminals AGK Cable gland holder For insertion in the plug-in base For 5 x Pg, one each on the narrow sides, three on the wide side Cable holder For insertion in the plug-in base With six knockout holes for cable entries (without cable tension relief) - x 8.8 mm dia. and x 7 mm dia. (laterally) - 3 x 7 mm dia. (on the front) - x rectangular opening 6 x 20 mm (on the front) Pedestal Empty housing for increasing the height of the to that of the F... or F7... (for height, refer to «Dimensions») AGK65 AGK66 AGK2 RC unit ARC 668 9066 0 For supervision of the ionization current in networks with non-earthed neutral PTC resistor (AC 230 V) To generate load on terminal 3 (used with burners with no fan motor, e.g. atmospheric gas burners) AGK25 Auxiliary unit for UV supervision AGQ2.A27 (cable length 500 mm) AGQ2.2A27 (cable length 300 mm) Can be fitted under the plug-in base (always use B-series); for dimensions, refer to «Dimensions» Actuators (refer to data sheet 7808) Actuators (refer to data sheet 780) Actuators (refer to data sheet 7806) SQ3... SQ7... SQ9... Service adapter KF8872 For checking the functioning of the burner controls on the burner plant Functional check with indicator lamps ote: with no load on the output terminals, the respective indicator lamp may light up! Detector current measurement with jacks of mm dia. Test case For checking the functioning of the burner controls away from the burner plant Adapters / replacement types o rewiring required ew type of burner control Adapter type Predecessor type G2... with adapter KF8853-K F7... KF8880 F... / F...-F G22... with adapter KF8853-K F7... KF8880 F... KF883 / CC72E June 5, 998 andis & Staefa

Technical data Flame supervision with detector electrode Flame supervision with AGQ2...A27 Operating voltage AC 230 V +0 % / -5 % Weight (AC 00 V -5 %...0 V +0 %) on request only - Burner control approx. 58 g - Plug-in base AGK approx. 80 g ains frequency 50 Hz -6 %...60 Hz +6 % - AGK65... approx. g Power consumption VA - AGK66... approx. g Primary fuse max. 0 A, slow Degree of protection P 0 ax. cable length terminals 8 and 0 20 m ounting position optional nput current to terminal max. 5 A dentification code to E 298 G2... / G22... F T X G25... F T C X Switching capacity of terminals At cos ϕ 0.6 At cos ϕ = - Terminal 3 max. 2.7 A max. 3 A (5 A during max. 0.5 s) - Terminals, 5 and 7 max..7 A max. 2 A - Terminal 0 max. A max. A Environmental conditions CE conformity Transport EC 72-3-2 According to the directives of the European Union Climatic conditions class 2K2 Electromagnetic compatibility EC Temperature range -0...+60 C 89 / 336 EEC incl. 92 / 3 EEC Humidity < 95 % r.h. Directive for gas-fired appliances 90 / 396 EEC echanical conditions class 22 Operation EC 72-3-3 Climatic conditions class 3K5 Temperature range -20...+60 C Humidity < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted! At mains voltage U = AC 230 V Detector voltage across terminals and 2 or ground AC 230 V (AC voltmeter, Ri 0 Ω) Switching thresholds (limit values) Switching on (flame on) DC ammeter, Ri 5 kω) DC µa ¹) Switching off (flame off) (DC ammeter, Ri 5 kω) DC 0.5 µa ax. short-circuit current across terminals AC 200 µa and 2 or ground (AC ammeter, Ri 5 kω) ¹) Based on the same quality of flame, the detector current with G... is approx. 30 % lower than with GB... Operating voltage AC 230 V +0 % / -5 % ax. cable length ains frequency 50 Hz -6 %...60 Hz +6 % QRA... to AGQ2...A27 20 m Power consumption.5 VA (separate cable) Degree of protection P 0 AGQ2...A27 to 20 m ounting position optional Weight AGQ2...A27 approx. 0 g QRA... refer to data sheet 77 At mains voltage U AC 220 V AC 20 V Detector voltage at QRA... (with no load) To the end of «t0» and after a controlled DC 620 V DC 675 V shutdown From the beginning of «t» DC 300 V DC 300 V Detector voltage oading by DC meter Ri > 0 Ω To the end of «t0» and after a controlled DC 500 V DC 550 V shutdown From the beginning of «t» DC 280 V DC 280 V DC current detector signals with UV detector QRA... a: measurement made on 3 µa 5 µa b: measurement made on UV detector 200 µa 500 µa Environmental conditions Transport EC 72-3-2 Climatic conditions class 2K2 Temperature range -0...+60 C Humidity < 95 % r.h. echanical conditions class 22 Operation EC 72-3-3 Climatic conditions class 3K5 Temperature range -20...+60 C Humidity < 95 % r.h. andis & Staefa CC72E June 5, 998 5/

Functions G2... / G25... A B B C D SB / R / W / GP tw t0 t t3 t3n 00 ms T t 0 3 7 5 8 72d05/098 G22... A B B C D SB / R / W / GP (R) 0 3 7 9 5 8 tw t t3n 00 ms t T t 72d06/098 t0+t egend Prerequisites for startup Undervoltage Checked intermittent operation Reversed polarity protection A Start command (switching on by «R») B-B nterval for establishment of flame C Operating position of burner reached C-D Burner operation D Controlled shutdown by «R» Burner is immediately shut down Burner control is immediately ready for new startup Fault status signal (alarm) Fan motor BV... Fuel valve R Control thermostat / pressurestat Remote reset button Actuator Flame signal SB Safety limit thermostat GP Gas pressure monitor W imit thermostat / pressure monitor Air pressure monitor gnition transformer R oad controller Burner control is reset All contacts in the line are closed Fan motor or AGK25 is connected Air pressure monitor is in idle position o undervoltage Safety shutdown in the event the mains voltage is lower than about AC 60 V (based on nominal AC 230 V) a restart is made when the mains voltage exceeds AC 95 V (based on nominal AC 230 V) After 2 hours of continuous operation at the latest, the burner control initiates a safety shutdown, followed by a restart. f the connections of line (terminal ) and neutral (terminal 2) have been exchanged, the burner control will initiate lockout at the end of «T». Control program in the event of fault Reset of f a fault occurs, the supply of fuel will immediately be stopped (< s) On restoration of power, a restart will be made with an unabridged program sequence f the operating voltage has dropped below the undervoltage threshold (for switching threshold, refer to «Functions»), a restart will be made with an unabridged program sequence f there is a premature faulty flame signal during «t», the burner control will initiate lockout Contacts of air pressure monitor welded in working position: prevention of startup and, after 8.5 seconds, lockout Contacts of air pressure monitor welded in idle position: lockout at the end of «t0» Air pressure failure on completion of «t0» ockout f the burner does not ignite by the end of «T» ockout f there is a flame failure during operation G2... / G22... lockout G25... three repetitions Whenever a lockout occurs, the burner control can immediately be reset! Keep lockout reset button depressed for a minimum of 0.5 seconds and a maximum of 3 seconds. 6/ CC72E June 5, 998 andis & Staefa

Connection diagram G2... / G25... G2.../25... 2 0 8 3 6 7 9 5 ) ¹) Wire link required only with GB2..., not with G2... / G25... 0 72a06/0598 Application examples Control of actuators of two-stage or two-stage modulating burners. Checked pre-purging «t» with low flame air volume. Exactly the same low flame actuator positions during startup and operation! For information about actuators : R RV SQ3...: refer to data sheet 7808 SQ7...: refer to data sheet 780 SQ9...: refer to data sheet 7806 72a07/0398 G2.../25... 2 0 8 3 6 9 7 5 (*) G2.../25... 2 0 8 3 6 7 5 GP/ SB R R 0 (*) * 2 6 7 5 3 b b2 B a a3 a b b S a b a2 a V b A a b V 72a03/0598 RV K KP K V u t V V t T 72d03/098 t 0 2 5 3 6 K2 + V a b D a b - + C3 K C3 V S a b a b R32 R a b 72a08/0598 K SQ3... / two-stage control * ote: with two-stage modulating burners (with gas regulation damper «RV»), and the dotted connection between terminals (*) are not required SQ9.0... / two-stage control G2.../25... 2 0 8 3 6 7 5 GP/ SB R 8 5 3 2 7 6 0 a c b2 KP V V B A b a2 C V 72a09/0598 K zu t T t t SQ7...2 / two-stage control andis & Staefa CC72E June 5, 998 7/

Connection diagram G22... G22... 2 0 8 3 6 7 5 9 0 72a5/0598 Application examples Control of actuators of two-stage or two-stage modulating burners. Checked pre-purging «t» with nominal load air volume. For information about actuators : SQ3...: refer to data sheet 7808 SQ7...: refer to data sheet 780 SQ9...: refer to data sheet 7806 R /2 72a/0598 G22... 2 0 8 3 6 9 5 7 R * G22... 2 0 8 3 6 9 5 7 R * 0 * 8 2 R3 7 5 6 3 9 K2 R K C2 + D - + R2 C S C3 V 72a3/0598 RV K KP K u t t T t 72d0/098 0 6 8 0 2 R3 3 7 9 R K2 C2 K + D - + C3 R2 S C 72a/0598 RV K SQ3...5... or SQ3...25... * ote: with two-stage modulating burners (with gas regulation damper «RV»), and the dotted connection between terminals (*) are not required SQ90.220... / two-stage modulating control G 22... G22... 2 0 8 3 6 5 9 7 2 0 8 3 6 9 5 7 R R 2 5 3 2 8 6 7 5 3 2 8 6 7 0 a b2 c KP V V 0 a b2 C A b a2 B V 72a7/0598 K zu t T t t A b a2 B V 72a8/0598 SQ7...5 / two-stage control, single-wire control SQ7...2 / two-stage control, two-wire control 8/ CC72E June 5, 998 andis & Staefa

Other application examples Burner without fan assistance and without Burner with fan control via auxiliary contactor with 2 3 6 AGK25 72a0/0398 * ote: different from GB2... * 2 3 6 AGK25 72a05/0398 egend *AGK25... PTC resistor Air pressure monitor Fault status signal (alarm) R oad controller BV... Fuel valve Fan motor Dbr... Wire link S Synchronous motor Remote lockout reset button ominal load Detector electrode QRA... UV detector Flame signal R Control thermostat / pressurestat GP Gas pressure monitor RV Gas regulation damper ain switch Actuator SQ... K... nternal relays SB Safety limit thermostat K ow flame t Time K Air damper W imit thermostat / pressure monitor KP Air damper position gnition transformer andis & Staefa CC72E June 5, 998 9/

Operating concept Burner control has initiated lockout Red fault indication lamp lit Burner control in operation Green flame signal lamp lit Reset Press lockout reset button for 0.5...3 s Diagnosis of cause of fault Wait > 0 s Press lockout reset button for > 3 s Read red fault indication lamp (Error code table) Restart Press lockout reset button for 0.5...3 s Read flame establishment time Press lockout reset button for > 3 s Read green flame signal lamp (Error code table) Diagnosis of cause of fault lit «red» After a lockout, the red fault indication lamp is steady on. Diagnosis of the cause of fault is based on the following sequence: ~ it phase (waiting time > 0 s) Press lockout reset button for > 3 s Blink code Refer to «Error code table» Off Approx. 3 s Blink code Refer to «Error code table»~ Error code table Blink code 2 x 3 x x 5 x 7 x 8...7 x... 8 x 9 x 20 x Possible cause o establishment of flame at the end of «T» Faulty or soiled detector electrode Faulty or soiled fuel valves Poor adjustment of burner Air pressure monitor does not close faulty Adjustment of too sensitive Fan motor does not run Air pressure monitor does not open faulty Adjustment of too sensitive Extraneous light Usually internal device fault oss of flame during operation Poor adjustment of burner Faulty or soiled fuel valves Short-circuit between detector electrode and ground Free Air pressure monitor opens Faulty output contact Wiring error External power supply on output terminal nternal device fault During the diagnosis of the cause of fault, the control outputs are dead. Burner remains shut down Exception: at terminal 0 The burner is switched on again only after pressing the lockout reset button: Press lockout reset button for 0.5...3 seconds 0/ CC72E June 5, 998 andis & Staefa

nterrogation of flame establishment time lit «green» n the running position, the green flame signal lamp is steady on. The flame establishment time is read based on the following sequence: ~ it phase (waiting time > 0 s) Press lockout reset button for > 3 s Blink code Refer to «Diagnostics table» Off Approx. 3 s Blink code Refer to «Diagnostics table» ~ Readout is in the form of a blink code (multiples of 0. seconds) Diagnostics table Blink code Flame establishment time with «T» = 3 s x 0. s 2 x 0.8 s Flame establishment time with «T» = 5 s 0. s 0.8 s 7 x 2.8 s 2.8 s x ---.8 s The flame establishment time is the period of time from the moment opens to the moment the flame signal is detected for the first time The flame establishment time remains stored for one startup sequence and is reascertained the next time the burner is started up During the period of time the flame establishment time is interrogated, the fault status outputs are dead: Burner remains shut down t is restarted only after a reset is made Press lockout reset button for 0.5...3 seconds Flame supervision with detector electrode The conductivity and the rectifying effect of hot flame gases are used for flame supervision. The flame signal amplifier responds only to the DC current component of the flame signal. A short-circuit between detector electrode and ground causes the burner control to initiate lockout easurement circuit 72v0/0598 + - + C For detector currents, refer to «Technical data». egend C Electrolytic capacitor (00...70 µf; DC 0...25 V) Detector electrode icroammeter (Ri max. = 5000 Ω) andis & Staefa CC72E June 5, 998 /

Flame supervision with UV detector QRA... and auxiliary unit AGQ2...A27 For UV detectors QRA..., refer to data sheet 77. Auxiliary unit AGQ2...A27 When using the QRA... in connection with burner controls, auxiliary unit AGQ2...A27 is required Using circuitry (A) or (B), the quench test on ageing UV detectors can be made in two different ways: egend Type of circuitry: (A) Operation with a permanent line UV test at twice the supply voltage (2 x U = AC 60 V) across the UV cell on startup and after a controlled shutdown (B) Operation with a controlled line UV test at twice the supply voltage (2 x U = AC 60 V) on startup only, during the interval between controlled startup and air pressure signal o voltage at the UV cell after a controlled shutdown o full substitute for mode (A) described above since an aged UV cell can regenerate itself Connection diagram 2 * (B) (A) 72a/0598 br bl rt sw AGQ2...A27 sw bl AGQ2.A27 AQG2.2A27 QRA + - easurement circuit a) easurement made on UV detector b) easurement made on AGQ2...A27 QRA + - sw bl sw bl - + + C 2 72v02/0598 AGQ2...A27 - + sw + C bl sw - + QRA bl 2 72v03/0598 egend C Electrolytic capacitor (00...70 µf; DC 0...25 V) bl blue icroammeter (Ri max. = 5000 Ω) sw black QRA... UV detector gr grey / CC72E June 5, 998 andis & Staefa

nternal diagram and program sequence G2... / G25... T Control of microcontroller RESET diagnosis EK 72a0e/0398 K K2 K3 K A B B C D 72d0/098 red green SB / R / W / GP K K2 2 0 Si / 7 3 K K3 5 8 6 V 0 3 7 (R) tw t0 t t3 t3n T t 5 8 G22... T Control of microcontroller EK RESET diagnosis 72a02e/0398 K K2 K3 K A B B C D 72d02/098 red green K V SB / R / W / GP 0 K K2 K3 3 7 2 Si / 0 7 3 9 5 R 8 6 (R) 9 5 tw t t3n t T t0+t t 8 egend EK nternal lockout reset button T Power section V Flame signal amplifier Si Fuse andis & Staefa CC72E June 5, 998 3/

Dimensions Burner control Dimensions in mm 5,5 62,5 Burner control with plug-in base AGK... and cable gland holders AGK65... (can be inserted in the base) 9 25 25 88 9 T 3 sec. VA P0 230 V~ 50-60 Hz CE - 0085AT000 72m0/0398,5 22 9550 6,5 62 < 3 sec. Reset > 3 sec. Diagn. Plug-in base 2 3 5 6 7 8 9 0 72m02/0398 Ø5, 3 32 7 23,5 Ø6,2 A Ø,5 2 2 30 30 C B AGK... Plug-in base with screw terminals Hatched: position of cable gland holder or cable holder «B»: holes for cable entry «3», «32»: auxiliary terminals : neutral terminals, connected to neutral input (terminal 2) Underneath: earth terminals, joining a lug for earthing the burner andatory: (AGK...) Connection of earthing lug «C» and fixing screws in «A» to the burner ground (using a metric screw with a lockwasher or similar) Auxiliary unit AGQ2...A27 27,5 90,5 60 220 69 6 Type Dimensions reference A B AGQ2.A27 500 9 AGQ2.2A27 300 3 8 65,6 5, 5, 3 72m0/0398 A B6 998 andis & Staefa Produktion (Deutschland) GmbH / CC72E June 5, 998 andis & Staefa