NOVELAN 44 50 103776HV1241 5 7 6 7 6 4
NOVELAN 103776HV1241
package (heat pumps and combination heater with heat pump) Seasonal space heating energy efficiency of heat pump (ηs) of the heat pump (Prated ) 137 3,5 5,7 Temperature control Class (Table 1) VII + Supplementary boiler package with hot water storage tank Psup (rated heat output of supplementary heater) ησ (συπ) ( ηs (sup) (αwe: see Table 3) ) x (αwp) = (αwe) solar contribution (AKoll m²) (ηkoll ) (VSp m³) (standstill heat loss of the hot water storage tank in W) (ηsp: Table 2) ((294/Prated x11) x (AKoll m²) + (115/Prated x11) x (VSp m3)) x 0,45 x ((ηkoll ) /100) x (ηsp) = + Seasonal space heating energy efficiency of package 141 rounded to the nearest integer Seasonal space heating energy efficiency class of package X < 30 30 34 36 75 82 90 98 125 150 Seasonal space heating energy efficiency under colder or warmer climate conditions Seasonal space heating energy efficiency of the heat pump (ηs) under colder climate conditions 95 Seasonal space heating energy efficiency of the heat pump (ηs) under warmer climate conditions 164 colder 141 V 42,4 = 98,6 warmer 141 +VI 26,5 = 167,5
heatpump datasheet: manufacturer: NOVELAN model: Information concerning energy efficiency class and rated heat output: average / low average / medium energy efficiency class space heater: A++ A++ rated heat output: 6,7 5,7 energy efficiency space heater: 183 137 annual final energy consumption space heater 2949 3321 h 44 sound power level indoors special precautions concerning assembly, installation or maintenance All instructional work in this manual may only be carried out by qualified specialist personnel in compliance with local regulations. additional information low medium rated heat output colder climate 6,5 5 rated heat output warmer climate 4,1 5,5 energy effiency space heater colder climate 160 95 energy effiency space heater warmer climate 236 164 annual energy consumption space heater colder climate 3945 5036 h annual energy consumption space heater warmer climate 915 1761 h 50 sound power level outdoors technical data of the temperature controller manufacturer: model: ait deutschland WPRNet 2.1 controller class VII contribution of the controller to the energy efficiency space heater 3,5
Model Airtowater heat pump: (/) Brinetowater heat pump: (/) Watertowater heat pump: (/) Lowtemperature heat pump: (/) Equipped with supplementary heater: (/) combination heater with: (/) application: (low/medium) medium climate: (colder/average/warmer) average Prated 6 Seasonal space heating energy efficiency ηs 137,2 Tj = 7 5,0 Tj = 7 2,31 3,5 3,43 3,0 4,86 3,4 6,56 5,0 2,31 4,2 2,12 For airtowater heat pumps: Tj = +15 (if TOL < 20) For airtowater heat pumps: Tj = +15 (if TOL < 20) Bivalent temperature Tbiv 7 For airtowater heat pumps: Operation limit temperature TOL 10 Cycling interval capacity for heating Pcych Cycling interval efficiency COPcyc Degradation coefficient (**) Cdh 1,0 WTOL 60 Psup 1,5 Power consumption in modes other than active mode Heating water operating limit temperature Supplementary heater Off mode POFF Thermostatoff mode PTO Type of energy input Standby mode PSB Crankcase heater mode PCK electrical Other items Capacity control variable sound power level, indoors/outdoors LWA 44 / 50 Emissions of nitrogen oxides NOX mg/h For airtowater heat pumps: Rated air flow rate, outdoors 2.500 For water/brinetowater heat pumps: Rated brine or water flow rate, outdoor heat exchanger ηwh Qfuel h For heat pump combination heater: Declared load profile Daily electricity consumption Contact details Qelec Water heating energy efficiency h Daily fuel consumption ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany (*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(tj). (**) If Cdh is t determined by measurement then the default degradation coefficient is Cdh = 0,9.
Model Airtowater heat pump: (/) Brinetowater heat pump: (/) Watertowater heat pump: (/) Lowtemperature heat pump: (/) Equipped with supplementary heater: (/) combination heater with: (/) application: (low/medium) low climate: (colder/average/warmer) average Prated 7 Seasonal space heating energy efficiency ηs 182,6 Tj = 7 5,9 Tj = 7 3,26 3,8 4,70 3,3 5,96 3,4 7,92 5,9 3,26 5,1 3,18 For airtowater heat pumps: Tj = +15 (if TOL < 20) For airtowater heat pumps: Tj = +15 (if TOL < 20) Bivalent temperature Tbiv 7 For airtowater heat pumps: Operation limit temperature TOL 10 Cycling interval capacity for heating Pcych Cycling interval efficiency COPcyc Degradation coefficient (**) Cdh 1,0 WTOL 60 Psup 1,6 Power consumption in modes other than active mode Heating water operating limit temperature Supplementary heater Off mode POFF Thermostatoff mode PTO Type of energy input Standby mode PSB Crankcase heater mode PCK electrical Other items Capacity control variable sound power level, indoors/outdoors LWA 44 / 50 Emissions of nitrogen oxides NOX mg/h For airtowater heat pumps: Rated air flow rate, outdoors 2.500 For water/brinetowater heat pumps: Rated brine or water flow rate, outdoor heat exchanger ηwh Qfuel h For heat pump combination heater: Declared load profile Daily electricity consumption Contact details Qelec Water heating energy efficiency h Daily fuel consumption ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany (*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(tj). (**) If Cdh is t determined by measurement then the default degradation coefficient is Cdh = 0,9. Powered by TCPDF (www.tcpdf.org)