POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 15 MAY NOVATEC, Inc All Rights Reserved.

Similar documents
POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved

NDB-15 through NDB-50

COMPRESSED AIR LOADER MODEL: AL-1

HB CDA SERIES WITH TEMPERATURE SETBACK

INSTRUCTION MANUAL. CDA2 Series. Central Drying Hopper Assembly with OverDry Protection

MCS-401A MCS-401 SINGLE STATION CONTROL PACKAGE

Vacuum Receivers VR-FL and VRH-FL Series

NDM-5 MEMBRANE DRYER for Plastics

Central Vacuum Dust Collector FDC Series

NovaDrier MEMBRANE DRYER for Plastics

VACUUM LOADERS GSL Series

Vacuum Receivers VR-FL and VRH-FL Series

Vacuum Receivers VR and VRP Series

NovaWheel DESICCANT WHEEL DEHUMIDIFYING INSTRUCTION MANUAL

NDB Dryers with NovaTouch PLC Control

VACUUM LOADERS GSL Series

Vacuum Receivers VR and VRP Series

Central Vacuum Dust Collector FDC Series

VACUUM LOADERS VL and VLP Series

Silo Manager: CL Analog Silo Controllers For up to 12 Silos

Advanced Resin Handling, Drying and Downstream Extrusion Systems for the Plastics Industry

Advanced Resin Handling, Drying and Downstream Extrusion Systems for the Plastics Industry

NovaDrier MEMBRANE DRYER for Plastics

Vacuum Receivers with Hinged Lid VRH and VRH-MM Series

Vacuum Receivers VR and VRP Series

Vacuum Receivers VR and VRP Series

NovaWheel DESICCANT WHEEL DEHUMIDIFYING DRYER INSTRUCTION MANUAL

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

NDB Dryers with NovaTouch PLC Control

Gas-Fired Heater with NovaTouch PLC Interface

Conveying Controls. Conveying, Drying and Blending Systems. Technical Service Available 24/7! D C F. For Extrusion, Injection and Blow Molding Plants

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

InstructIon Manual KrEs EQuIPMEnt stands

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

525 EAST STOP 18 ROAD GREENWOOD, IN PHONE: FAX:

Horizontal Bottle Cooler Installation and Operation Manual

Installation and Operations Manual

PROTEK DRYER CONTROLS

Refrigerator Freezer Installation and Operation Manual

Dust Collector. Sizes DC1 and DC2 U S E R G U I D E UGC

OPERATING INSTRUCTIONS

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

MDH Series Air Dryer. User s Guide

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

NEWGATE TECHNOLOGIES, INC.

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

CPX MEDICAL AIR PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

VSA Series Air Dryer. User s Guide

SFD. Suburban Filter Dryer. User Manual Installation Instructions

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Control Panel For Water Wash Hoods AM2

Compressed Air Dryer

DBF 4XL Dryer Booster Fans

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Glass Door Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

Blade Series Heat Exchanger Operation and Installation

Installation & Maintenance Instructions

PDF Created with deskpdf PDF Writer - Trial ::

15Hp/20Hp Deluxe Compressor-Dryer System

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Dry Air Pac ENGINEERED COMPRESSED AIR DRYING SYSTEMS FOR COLD STORAGE/ FREEZER ROOM DRY PIPE SPRINKLER SYSTEMS

Installation & Operation Manual Ice Cream Freezers

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

TrueClean ToteCleaner

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

OPERATING INSTRUCTIONS

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

READ AND SAVE THESE INSTRUCTIONS. Air Boss Model T5200 Custom Packaged Electronic Air Cleaner. TRION

MODEL MPM-2 MPM-9 MPM-18 MPM-50 LIQUID COLOR PRE-MIXER

PORT700CF Portable Fume Collector

Electric Duct Heaters

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Panel Fan Series Operators Manual (Galvanized and Polymer)

Transcription:

POD Silo Dehumidifier Series with Logo! TM PLC POD-150 NOVATEC, Inc. 2017 All Rights Reserved DOCUMENT: POD IM 15 MAY 2017 Page 1 of 2

NOTES: Please record the following information, which is specific to this piece of equipment, in the space provided. Our Parts/Service Department will need these numbers to properly respond to any of your requests. Instruction Manual: POD IM 15 MAY 2017 Model #: Serial # DISCLAIMER: NOVATEC, Inc. shall not be liable for errors contained in this Instruction Manual nor for misinterpretation of information contained herein. NOVATEC shall not, in any event, be held liable for any special, indirect or consequential damages in connection with performance or use of this information. POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 2

Table of Contents 1.0 GENERAL DESCRIPTION... 4 1.1 Introduction... 4 1.2 Principle of Operation... 4 1.2.2 Adsorption Cycle... 4 1.2.3 Regeneration cycle... 4 2.0 UNPACKING AND INSTALLATION... 5 2.1 Unpacking... 5 2.2 General Inspection... 5 2.3 Installing the Dehumidifier... 5 2.3.1 Locating the dehumidifier... 5 2.3.2 Regeneration Outlet... 5 2.4 Utility Connection... 5 3.0 START-UP PROCEDURE... 6 4.0 THREE HOUR SEQUENCE of OPERATION... 7 5.0 PLC COUNTER SETTINGS... 7 7.0 TROUBLE SHOOTING GUIDE... 9 8.0 WARRANTY... 12 POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 3

1.0 GENERAL DESCRIPTION 1.1 Introduction The POD Series dual-bed dryer is a continuous-duty desiccant dryer designed to supply an uninterrupted flow of constant, low dew point air. The unit is completely automatic and requires very little maintenance to offer many years of trouble free service. Cycle operation is controlled by a Siemens Logo PLC. 1.2 Principle of Operation 1.2.2 Adsorption Cycle The reduction of moisture is accomplished by use of an adsorbent material (Silica Gel). The adsorption blower draws humid air across the filters (and if supplied a pre-cooler) and down through the tower of adsorption. The desiccant material extracts water vapor from the flow, and dry air is supplied at the dehumidifier outlet. Before the bed on adsorption reaches the saturation point, the 4-way valves automatically reverse and transfer the humid airflow to the opposite tower that has been previously regenerated. 1.2.3 Regeneration cycle While one bed is on adsorption, the opposite is on regeneration. The regeneration blower forces ambient air through the regeneration heater and up through the saturated bed. The air is heated to the temperature required to vaporize water absorbed by the desiccant during the preceding drying period. Water vapor carried from the tower by the air is discharged to the ambient through the regeneration outlet duct. The heater is de-energized when the desiccant is dry, and the bed is cooled to the required adsorption temperature. Adsorption and regeneration alternate automatically between the two towers in a continuous cycle. Pre-cooling the drying air returning from the hopper lowers inlet temperature to below 150 degrees F., maintaining high desiccant efficiency. Pre-coolers also condense out unwanted contaminants including plasticizers harmful to the dryer operation. POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 4

2.0 UNPACKING AND INSTALLATION 2.1 Unpacking Caution should be exercised to see that the equipment is not handled roughly. The crate must be removed carefully. The machine must not be used to pry against when removing the crate. The dryer is shipped completely assembled and requires no further attention prior to installation. 2.2 General Inspection When the unit is unpacked, make a visual inspection looking for missing parts or damage received during shipment. All electrical and mechanical connections should be checked for tightness, as vibration during transit may cause them to loosen. 2.3 Installing the Dehumidifier 2.3.1 Locating the dehumidifier The dehumidifier should be placed on a level base so the desiccant bed remains level inside the unit. This is extremely important! If the desiccant level is not the same across the bed, the resistance to airflow is different and the air will take the path of least resistance, which affects the efficiency of the unit. 2.3.2 Regeneration Outlet The regeneration outlet duct discharges hot, humid air and although it is not required, in some cases ducting this air away may be desirable. Extreme caution must be given to the length of this duct as not to cause back - pressure to the regeneration blower. Contact the factory if the duct length will exceed 4 feet. If ducting outside, the reactivation air duct should be slanted down to prevent rain and condensation from entering the dryer. A trap for the condensate should be installed at the lowest point. 2.4 Utility Connection Connect the proper power supply through a main line disconnect (field supply) to terminal block marked L1-L2-L3 and ground in the control cabinet. This is the only power supply required, as the unit is completely pre-wired and supplied with a control voltage transformer to supply 115 volt to the control circuit. If the unit is equipped with a pre cooler, the condensate drain underneath the pre-cooler should be connected to suitable drainage. The proper water supply should be connected to pipes marked Inlet-Outlet on the side of the precooler. POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 5

3.0 START-UP PROCEDURE 3.1 With electrical connections checked, and the proper power supply connected, see that the Power On/Off switch, located on the outside of the control cabinet, is in the Off position. 3.2 Energize the dryer by switching ON the field supplied disconnect switch, Power light and Logo PLC should energize. 3.3 Start the dryer by moving the Power OFF/ON switch to the ON position. 3.4 At first, jog the Power OFF/ON switch to establish blower rotation. (Do not assume that the blower is turning correctly if air is moving across the towers. Blowers of this design move air in either direction.) Make certain that the blower (s) are turning in the direction of the rotation arrow or by removing the filter (s) and observing the blower wheel(s). 3.5 With blower rotation established, check the three electrical leads in the control cabinet to see that the blower(s) are not pulling the above nameplate amperage (see nameplate on blower for amperage rating at proper voltage). If the blower is equipped with an adjustable slide gate, adjust this slide gate so blower is pulling nameplate amperage. (In some cases, the slide gate will be fixed and the blower will operate below nameplate amperage. This condition was established in the factory.) DO NOT ATTEMPT TO CHANGE. 3.6 Press ESC button on the Logo PLC, press the arrow to the Set Param line. Press OK button. Main counter B1 should display with Cnt value at bottom of screen. Cnt value represents current count in minutes for the total cycle. If counter B1 fails to display, press or arrows until B1 displays with Cnt value. To fast cycle advance counter B1 connect the 115V hot wire to PLC input I2. Check schematic diagram for wires numbers to jump for fast cycle advance. Each 1 minute count becomes 1 second in the fast advance mode. On initial start fast advance B1 counter to 0 or 1 Counter value. Reference the chart below for sequence of operation. POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 6

4.0 THREE HOUR SEQUENCE of OPERATION Time Counter, B1 3 Hour Cycle 0 Hour, 0 Minutes 0 Bed shift, Left bed drying. 0 Hour, 1 Minutes 1 Right bed heating, regen blower & heater on. 1 Hour, 10 Minutes 70 Right bed dynamic cooling, regen heater off. 1 Hour, 20 Minutes 80 Right bed static cooling, regen blower off. 1 Hour, 30 Minutes 90 Bed shift, right bed drying. 1 Hour, 91 Minutes 91 Left bed heating, regen blower & heater on. 2 Hour, 40 Minutes 160 Left bed dynamic cooling, regen heater off. 2 Hour, 50 Minutes 170 Left bed static cooling, regen blower off. 3 Hour, 0 Minutes 180 Bed shift, left bed drying. 4.1 When Counter B1 has a value of 1 the regeneration heater contactor is energized and the right bed will begin heating. Verify regen blower rotation (if a 3Ph regen blower is supplied). Check each heater lead for proper amperage (See Schematic Diagram). Verify adjustment of regeneration temperature controller. (Factory preset, See Schematic Diagram.) This can be accomplished by removing the ½ pipe plug located in the right tower lower duct and temporarily installing a thermometer. This actual inlet temperature may be less than the preset adjustment of the controller. The regeneration air outlet temperature should also be checked after the unit has cycled at least 24 hours with no load on the initial start-up. At the end of the heating period the regen outlet temp should be 275 degrees F. A ½ pipe plug located in the right tower upper duct can be removed and a thermometer temporarily inserted for this purpose. If the correct temperatures are obtained with the right bed, the left regeneration temperature will also be correct. 5.0 PLC COUNTER SETTINGS Counter ON Value OFF Value Description B1 180 0 Cycle reset, bed shift B3 0 90 Bed shift B4 91 170 Left regen blower B5 1 80 Right regen blower B7 91 160 Left regen heater B8 1 70 Right regen heater POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 7

6.0 MAINTENANCE AND INSPECTION SCHEDULE 6.1 It is recommended that maintenance and inspection is done on a scheduled basis. Maintenance requirements will naturally vary widely for each installation and specific operation conditions. It is suggested that a complete inspection be preformed with necessary maintenance at the end of the first month, the first three months, and the first six months. These inspections will be indicative of how often future maintenance will be necessary. 6.2 Every Month A. Inspect air filters, Clean or replace as required. Replace if cartridge is broken. The time interval for inspection should be shortened if experience indicates unusual dust loading. B. Check system for air leaks and correct as required. 6.3 Every 3 Months A. Units equipped with sleeve bearing motors should be lubricated with SAE 20 oil. B. Units equipped with ball bearing motors are factory greased and should be relubricated with a high - grade ball bearing grease. 6.4 WHEN ADDING LUBRICANT 1. Remove filter - plug at the bearings and install grease fittings suitable to your grease guns. Also, remove the drain plug at the bearings. 2. Add ball bearing grease until all of the old grease is expelled through the drain hole. 3. Run motor with drain plug removed to eliminate excess grease. 4. Clean and replace drain plugs. C. Check heater amperage (See Electrical Drawing). D. Check motor (s) amperage (See Electrical Drawing). NOTE: Most units are equipped with permanently lubricated bearings and no lubrication is required. All motors should be examined on an individual basis. 6.5 Once Every Year Check dehumidifier valve linkage and operation of valve. 6.6 Every 2 Years or as Needed Remove top covers of towers and replace desiccant. Replace sealing gaskets under lids. (See Mechanical Drawing for amount of desiccant). POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 8

7.0 TROUBLE SHOOTING GUIDE Most drying problems are the result of dirty filters, air leaks, desiccant contaminants and malfunctioning regeneration heaters. It is seldom that other components fail. PROBLEM INVESTIGATE Machines won t start A, B, C, D Inadequate or No Regeneration Heat B, F, G, H, I, J, K, L, M, N Inadequate or No Adsorption Air Flow B, E, I, K, L, N Inadequate or No Regeneration Air Flow B, F, H, I, K, L, N Inadequate Dew Point F, G, H, I, J, K, L, M, N, P Changeover Temp. Too High F, H, K, L, M, N POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 9

CHECK CONDITIONS SOLUTIONS A. Power Supply No voltage or voltage Check field installed incorrectly Disconnect and re-connect B. Motor Starter Overloads tripped Reset incoming power supply. 1. Voltage on line side Replace starter starter energizes, no voltage on load side. C. Transformer No voltage on primary See A 1. No voltage on secondary Check fuse; if ok replace transformer D. On/Off Switch No voltage through switch Replace switch E. Adsorption Motor No voltage at motor See B 1. Voltage at motor Replace motor amperage incorrect. F. Logo PLC Voltage at PLC, but no Check that PLC is in outputs start mode & input I1 is on. G. Heater Amperage Voltage correct, amperage Replace Heater Incorrect H. Regeneration Motor No voltage at motor See B 1. Voltage at motor Replace motor amperage incorrect. I. Valve position Valve position not correct Check Valve linkage J. Valve Motor No voltage at motor Replace motor 1. Voltage at motor, valves move freely by hand with linkage disconnected. K. Blower Rotation Incorrect Reverse phase L. Filter Filter dirty Replace element POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 10

CHECK CONDITION SOLUTION M. Regeneration Heater Adjustment incorrect. Adjust Temperature Controller No voltage across Replace controller switch. N. Air Ducts Obstructed Remove obstruction O. Leaks in system Air leaking in or out Replace gaskets, of system. repair leaks as necessary P. Desiccant Contaminated Replace desiccant 1. Saturated Dry cycle for 24 hours. POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 11

8.0 WARRANTY WARRANTY NOVATEC, INC. - Effective Date 8 MAY 2017 NOVATEC, INC. offers COMPREHENSIVE PRODUCT WARRANTIES on all of our plastics auxiliary equipment. We warrant each NOVATEC manufactured product to be free from defects in materials and workmanship, under normal use and service for the periods listed under Warranty Periods. The obligation of Novatec, under this warranty, is limited to repairing or furnishing, without charge, a similar part to replace any part which fails under normal use due to a material or workmanship defect, within its respective warranty period. It is the purchaser s responsibility to provide Novatec with immediate written notice of any such suspected defect. Warranted replacement parts are billed and shipped freight pre-paid. The purchaser must return the suspect defective part, freight prepaid and with identifying documentation to receive full credit for the part returned. Novatec shall not be held liable for damages or delay caused by defects. No allowance will be made for repairs or alterations without the written consent or approval of The provisions in equipment specifications are descriptive, unless expressly stated as warranties. The liability of Novatec to the purchaser, except as to title, arising out of the supplying of the said equipment, or its use, whether based upon warranty, contract or negligence, shall not in any case exceed the cost of correcting defects in the equipment as herein provided. All such liability shall terminate upon the expiration of said warranty periods. Novatec shall not in any event be held liable for any special, indirect or consequential damages. Commodities not manufactured by Novatec are warranted and guaranteed to Novatec by the original manufacturer and then only to the extent that Novatec is able to enforce such warranty or guaranty. Novatec, Inc. has not authorized anyone to make any warranty or representation other than the warranty contained here. Non-payment of invoice beyond 90 days will invalidate the warranty. A renewed warranty can be purchased directly Novatec. from Novatec. Please note that we always strive to satisfy our customers in whatever manner is deemed most expedient to overcome any issues in connection with our equipment. Warranty Periods: Note: All warranty periods commence with the shipment of the equipment to the customer. 5-Year Resin Drying to Include NovaWheel Dryers * Dual Bed Dryers NovaDrier * NDM-5 Membrane Dryer Gas-Fired Process Heaters Gas-Fired Regeneration Heaters Drying Hoppers Central Drying Hopper Assemblies Heater/Blower Units and Hot-Air Dryer Silo Dehumidifiers NovaVac Dryers * Resin Blending and Feeding to Include WSB Blenders, MaxiBatch & Feeders * Gaylord Sweeper Systems Resin Conveying to Include GSL Series Vacuum Loaders GlassVu Loaders, Receivers and Hoppers Downstream Extrusion Equipment to Include C and NC Bessemer Series Cutters NPS Bessemer Series Pullers NPC Mini Puller/Cutter All NS Series Servo Saws All Cooling and Vacuum Tanks Manufactured by Novatec 3-Year When a Prophecy data plan is activated for VPDB and SVP pumps with PumpSense, Novatec automatically extends the warranty to 3 years. The data plan must be activated within 60 days after pump shipment, and remain active through the warranty period to maintain extended warranty eligibility. The first 6-months of data plan usage is free from Novatec. 2-Year Central System Controls to Include FlexTouch Series Controls FlexXpand Series Controls OptiFlex Series Controls PLC Communications Modules Greenboard Communications Modules LOGO! Mini PLC Moisture Measurement Equipment to Include MoistureMaster PET Resin Crystallizers 1-Year Resin Conveying and Systems Components to Include VL/VLP Series Loaders VRH, VR, VR-FL & VRP Series Receivers Compressed Air Loaders AL-B Barrel Loader Cyclone Dust Collectors Conveying System Accessories Surge Bins Valves and Accessories Electronic Metal Separators Quick Select Manifolds Tilt Tables Filter Dust Collectors Drawer Magnets Resin Conveying System Components to Include *VPDB Vacuum Positive Displacement Pumps *SVP Vacuum Pumps MVP Vacuum Pumps UltraVac Vacuum Pumps Vacuum Regenerative Blower Pumps Velocity Control Valves *See 3-Year Warranty above Central System Controls to Include MCS-600 Series Controls (Distributed I/O) MCS-400 Series Controls CL Silo Manager Infrared Dryers Custom Equipment of any kind unless otherwise specified Railcar Unloading Systems POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 12

Exclusions: Routine maintenance/replacement parts are excluded from the warranty. These include, but are not limited to: hoses, desiccant, filters, filter elements, wiper seals, gaskets, dew point sensors, infrared lamps, motors, internal solenoids, fuses and motor brushes. Use with abrasive materials will void the warranty of any standard product. Wear resistant options may be available to extend usable service life with abrasive materials. Novatec reserves the right to limit the warranty if the customer installs replacement parts that do not meet the specifications of the original parts supplied by Novatec. *Specific Exclusions: 1. NovaDrier warranty is void if coalescing filters are not replaced on a 6-month or yearly basis (per instruction manual) and/or membrane has been exposed to ozone. 2. NovaVac Dryer -The ability of the canisters to hold vacuum will be compromised if the vacuum seal edge is damaged from mishandling. We do not warranty canisters damaged from improper handling. We do, however, warranty the seals. 3. LOAD CELLS on our WSB s are covered by Novatec standard warranty as long as they have not been damaged from improper handling. 4. Desiccant Wheel Warranty will be void if the wheel has been exposed to plasticizer, dust or other contaminants as a result of negligence on the part of the processor. This warranty shall not apply to equipment: 1. Repaired or altered without written approval of NOVATEC unless such repair or alteration was, in our judgment, not responsible for the failure 2. Which has been subject to misuse, negligence, accident or incorrect wiring by others 3. Warranty is void if processing rates exceed manufacturer-recommended levels or if damage is caused by ineffective power isolation and/or power spikes/sags or incorrect installation. NOTE: All conditions and content of this warranty are subject to changes without notice. POD IM 15 MAY 2017 2017 NOVATEC, Inc. All Rights Reserved Page 13