Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

Similar documents
TECHNICAL DROP-IN SPECIFICATIONS

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

Super Gripnet INTEGRATED DRAINAGE SYSTEM (IDS) GEOMEMBRANE

SPECIAL SPECIFICATION 3687 Impermeable Liner

Liner Construction & Testing Guidance Overview

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

GEOMEMBRANE INSTALLATION GUIDELINES AND SPECIFICATIONS FOR LLDPE 20, 30, AND 40 MIL UNREINFORCED & GEO-SKRIM SERIES REINFORCED LINERS.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIFICATIONS AND TECHNICAL REQUIREMENTS FOR THE MANUFACTURING AND INSTALLATION OF POLYETHYLENE GEOMEMBRANES

SPECIFICATIONS AND TECHNICAL REQUIREMENTS FOR THE MANUFACTURING AND INSTALLATION OF POLYETHYLENE GEOMEMBRANES

GEOMEMBRANE AND DRAINAGE INSTALLATION SPECIFICATION

Section Specification for Geotextile Used in Permanent Erosion Control Application

Acronyms. TRI TRI Environmental, Inc. Table of Contents. iii

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

III.DRAINAGE. This section describes the use of geotextiles in underdrains for two different field conditions:

UNIFIED FACILITIES GUIDE SPECIFICATION

SECTION 02230BP AGGREGATE BASE

PVC GEOMEMBRANE FABRICATION AND INSTALLATION SPECIFICATION

CalTrans tackles The Merge

GEOMEMBRANE FIELD INSTALLATION

V. EROSION CONTROL. -Drainage swales separation -Under rip-rap protected -Under rip-rap unprotected

APPENDIX A POND LINING TECHNICAL SPECIFICATIONS

MATERIAL SPECIFICATION FOR GEOTEXTILES

UNIFIED FACILITIES GUIDE SPECIFICATION

Geosynthetics for the Management, Containment and Closure of Coal Combustion Residual Disposal Facilities

Geosynthetic Institute GSI GRI GT13(b) ISO Version

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL

GRI White Paper #12. The Development of a Benefit/Cost Ratio Matrix for Optimal Selection of a Geosynthetic Material

Leak Location Geosynthetic Materials in Base Liner Systems. NY Federation SWANA. May, 2014

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Introduction To Geosynthetics In Transportation

CAPPING OF A GOLD MINE IN ROSIA MONTANA, ROMANIA

SECTION TABLE OF CONTENTS GEOTEXTILE TUBES PARAGRAPH TITLE PAGE NOS.

geotextiles bidim Nonwoven polyester geotextile Made in Australia Designed for performance RECYCLED Quality ISO 9001

D.P.E. Enviroliner. geotextile protection layer. covering new ground 2016

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Elements of Design of Multi-linear Drainage Geocomposites for Landfills

FOR PROJECTS INITIATED AFTER FEBRUARY 1, 2010 REVISION 1 ITEM 709 TRIANGULAR FILTER FABRIC FENCE

REHABILITATION OF SAIDA DUMPSITE

MATERIAL SPECIFICATION FOR GEOTEXTILES

Evaluating Tubular Drainage Geocomposites for use in Lined Landfill Leachate Collection Systems

INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS

GRI White Paper #8. - on - Construction Quality Assurance-Inspectors Certification Program (CQA-ICP)

geotextiles bidim Nonwoven polyester geotextile Made in Australia Designed for performance RECYCLED

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form

PRESTO GEOTERRA GTO FAST DEPLOYMENT CONSTRUCTION MAT SYSTEM SPECIFICATION & INSTALLATION GUIDELINE

American Railway Engineering and Maintenance of Way Association Letter Ballot

AQUAMASTER INSTALLATION GUIDE

Engineering Report: Appendix F Volume 3 Landfill Liner Construction Specifications COWLITZ COUNTY HEADQUARTERS LANDFILL PROJECT COWLITZ COUNTY, WASHIN

Firestone Reinforced Polypropylene (fpp-r) Geomembrane

Capping waste rock at a Superfund site An innovative design tackles pollution at a mining operation s waste repository.

MODULUS CHARACTERISTICS OF GEOSYNTHETICS USED IN ROADWAY CONSTRUCTION

Air-channel testing landfill geomembrane seams

AASHTO M Subsurface Drainage

Chesapeake Energy Center. Submitted To: Chesapeake Energy Center 2701 Vepco Street Chesapeake, VA 23323

Geotextile Separation Interlayer Guide Specification

Charudatta R. Prayag Deputy Director Ahmedabad Textile Industry s Research Association Ahmedabad

Module 5 Erosion & Sediment Control. Introduction To Geosynthetics In Transportation. Prepared by. For the Local Technical Assistance Program

Selecting the Right Closure Cap Option for Your Surface Impoundment or CCR Landfill

ACTIVITY: Geotextiles ES 12

Sea to Sky Geotechnique 2006

EARTH STABILIZATION GEOSYNTHETIC SOLUTIONS

INTERNATIONAL ASSOCIATION OF GEOSYNTHETICS INSTALLERS (IAGI) AND FABRICATED GEOMEMBRANE INSTITUTE (FGI)

Aquaculture Lining Systems

We Don t Have No Stinkin Dirt! Coal Ash Pond Closures (Traditional and an Alternative Method)

Technical Supplement 14D. Geosynthetics in Stream Restoration. (210 VI NEH, August 2007)

J. K. Gupta, Scientist D, Bureau of Indian Standards

SOUTH AFRICAN NATIONAL STANDARD

MATERIAL SPECIFICATION FOR GEOTEXTILES

POND SEALING OR LINING GEOMEMBRANE OR GEOSYNTHETIC CLAY LINER

SWANA/A&WMA s. Third Annual Landfill Operator s Training Geosynthetics in Landfills. February 13, 2013

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Horsehead Holding Corporation Relies on XR-5

Rhyno. Woven Polypropylene Geotextiles. Geosynthetics Limited

NOTICE OF INTENT. Submitted To: Bremo Power Station 1038 Bremo Bluff Road Bremo Bluff, VA 23022

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

and Water Features and Water Features

Soil/Geosynthetic Interface Strengths from Torsional Ring Shear Tests

Geomembranes that work

Woven Polypropylene Geotextiles

Lessons Learned From the Failure of a GCL/Geomembrane Barrier on a Side Slope Landfill Cover

Pozidrain. A guide to the selection and specification of Pozidrain drainage geocomposite

CI/SfB (16)(17) Common Arrangement D11 Uniclass L1411/ L132/ L6634. Woven Polypropylene Geotextiles.

Basic Geosynthetics: A Guide to Best Practices in Forest Engineering

Geotextile Tube Structures: Example Contract Specifications

POLYETHYLENE GEOMEMBRANE SPECIALIST. For environmental lining solutions. the world comes to GSE

Introduction. Functions of Non woven Geotextile (TechGeo) Separation. Filtration. Drainage. Containment. Tech Geo. . Geotextile Overview

Stormwater protection

Geomembranes that work

Moisture Content Effect on Sliding Shear Test Parameters in Woven Geotextile Reinforced Pilani Soil

RG1,5SA Self Adhesive

Firestone GeoGard EPDM Review of Technical Performances

DUPONT TM PLANTEX LANDSCAPE SOLUTIONS Guidebook

Civil engineering Fibertex Geotextiles

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Leakage through Liners under High Hydraulic Heads. PH (512) ; FAX (512) ;

A Collection and Removal System for Water in the Final Cover Drainage Layer

Exposed Geomembrane Cover Systems for Coal Ash Facilities

D DAVID PUBLISHING. 1. Introduction. Dr. Vivek Ganesh Bhartu

E R O S I O N C O N T R O L

Transcription:

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

The following specification is a sample guideline to be customized by the engineer for preparing site specific specification. This information is provided for reference purposes only and is not intended as a warranty or guarantee. AGRU assumes no liability in connection with the use of this information. Part 1 GENERAL 1.1 DESCRIPTION OF WORK 1. This specification covers the Integrated Drainage System (IDS) geomembrane, a flat cast structured polyethylene geomembrane with integrated drainage layer. For this application the IDS geomembrane shall be covered with a nonwoven geotextile to provide filtration for the capping drainage system. The work for this section includes furnishing all labor, material and equipment to complete the installation of the IDS geomembrane, including all necessary and incidental items, in accordance with the Plans and Specifications. 1.2 RELATED DOCUMENTS 1. The conditions and description of work shown in other sections of these Specifications, the Plans for Construction, Construction Quality Assurance (CQA) Plan, and other Contract Documents apply to this section. 1.3 REFERENCES A. The latest revision of the following standards of the American Society of Testing and Materials (ASTM) are hereby made part of these Specifications. 1. D792 Method B, Density and Specific Gravity of Plastics by Displacement 2. D1004 Initial Tear Resistance of Plastic Film and Sheeting 3. D1238 Flow Rates of Thermoplastics by Extrusion Plastometer 4. D3895 Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 5. D4218 Determination of Carbon Black in Polyethylene Compounds 6. D4833 Index Puncture Resistance of Geotextiles, Geomembranes, and Related Products 7. D5397 Evaluation of Stress Crack Resistance of Polyolefin Geomembranes Using Notched Constant Tensile Load Test 8. D5596 Microscopic Evaluation of the Dispersion of Carbon Black in Polyolefin Geosynthetics 9. D5994 Measuring Core Thickness of Textured Geomembranes 10. D6392 Determining the Integrity of Nonreinforced Geomembrane Seams Produced Using Thermo-Fusion Methods 11. D6693 Determining Tensile Properties of Nonreinforced Polyethylene and Nonreinforced Flexible Polypropylene Geomembranes 12. D7466 Measuring Asperity Height of Textured Geomembranes B. Geosynthetic Research Institute 1. GRI GM Test Methods, Test Properties and Testing Frequency for High Density Polyethylene (HDPE) Smooth and Textured Geomembranes 2. GRI GM 17 Test Properties, Test Properties and Testing Frequency for Linear Low Density Polyethylene (LLDPE) Smooth and Textured Geomembranes 3. GRI GC 8, Standard Guide for Determination of Allowable Flow Rate of a Drainage Geocomposite 1.4 DEFINITIONS A. Project Name and location of project here. 2

B. Owner Name of owner here. C. Lot - A quantity of resin (usually a rail car) used in the manufacture of geomembranes. Finished roll will be identified by a roll number traceable to the resin lot used. D. Construction Quality Assurance Consultant (CONSULTANT) - Party, independent from MANUFACTURER and INSTALLER that is responsible for observing and documenting activities related to quality assurance during the lining system construction. E. ENGINEER- The individual or firm responsible for the design and preparation of the project s Contract Drawings and Specifications. F. Geomembrane Manufacturer (MANUFACTURER) - The party responsible for manufacturing the geomembrane rolls. G. Geosynthetic Quality Assurance Laboratory (TESTING LABORATORY) - Party, independent from the OWNER, MANUFACTURER and INSTALLER, responsible for conducting laboratory tests on samples of geosynthetics obtained at the site or during manufacturing, usually under the direction of the OWNER. H. INSTALLER- Party responsible for field handling, transporting, storing, deploying, seaming and testing of the geomembrane seams. The Installer shall be approved by the Manufacturer and shall have current Approved Installation Contractor (AIC) status issued by the International Association of Geosynthetic Installers (IAGI www.iagi.org). I. Panel - Area of a geomembrane that will be seamed in the field that is larger than 100 ft 2. J. Patch - Area of a geomembrane that will be seamed in the field that is less than 100 ft 2. K. Subgrade Surface - Soil layer surface which immediately underlies the geosynthetic material(s). 1.5 SUBMITTALS A. The Manufacturer shall furnish the following product data, in writing, to the Consultant for approval at least ten (10) working days prior to shipment of the IDS geomembrane material: 1. Resin Data shall include the following: a. Certification stating that the resin meets the specification requirements (see Table 1.9). 2. Geomembrane Roll a. Statement certifying no recycled polymer and no more than 10% rework of the same type of material is added to the resin (product run may be recycled). b. Material samples for interface shear testing as required. c. Quality Control Certificates signed by the Manufacturer shall be provided for each roll. Each certification shall have the roll identification number, test methods, frequency, and test results. At a minimum, the test results and frequency shall be as shown in Table 1. B. The INSTALLER shall furnish the following information to the ENGINEER and OWNER prior to installation: 1. Installation layout drawings a. Must show proposed panel layout including field seams and details Seams should generally follow the direction of the slope. Butt seams or roll-end seams should not occur on a slope unless approved by the Owner s Representative. Butt seams on a slope, if allowed, should be staggered and/or installed at 45 angle to the slope. b. Must be approved prior to installing the geomembrane 3

2. Approved drawings will be for concept only and actual panel placement will be determined by site conditions. 3. Installer s Geosynthetic Field Installation Quality Control Plan C. The INSTALLER will submit the following to the ENGINEER upon completion of installation: 1. Material and installation warranties 2. As-built drawings showing actual geomembrane placement and seams including typical anchor trench detail and location of repairs. 1.6 DELIVERY, STORAGE, AND HANDLING A. Delivery 1. Rolls of IDS geomembrane will be prepared to ship by appropriate means to prevent damage to the material and to facilitate off-loading. Labels on each roll of IDS geomembrane shall identify the product, length, width, lot and roll numbers, and name of Manufacturer. B. Storage 1. The onsite storage location for the IDS geomembrane will be provided by the Owner. The IDS geomembrane shall be protected from punctures, abrasions and excessive dirt and moisture. The storage area shall have the following characteristics: a. Level (no wooden pallets) b. Smooth c. Not subject to ponding or flooding d. Protected from theft and vandalism C. Handling 1. Materials are to be handled so as to prevent damage and per manufacturer guidelines 1.7 WARRANTY A. IDS geomembrane material shall be warranted, on a pro-rated basis against Manufacturer s defects for a period of (1) year from the date of IDS geomembrane installation B. Installation shall be warranted against defects in workmanship for a period of one (1) year from the date of IDS geomembrane installation. 2 PRODUCTS 2.1 IDS GEOMEMBRANE A. A. The IDS geomembrane shall be, first quality products designed and manufactured specifically for the purpose of this work which shall have been satisfactorily demonstrated by prior testing to be suitable and durable for such purposes. The IDS geomembrane rolls shall be seamless, high density polyethylene (HDPE - Formulated Sheet Density 0.94 g/cc) or linear low density polyethylene (LLDPE - Formulated Sheet Density 0.939 g/cc) containing no plasticizers, fillers or extenders and shall be free of holes, blisters or contaminants, verified by 100% in-line spark testing. The IDS geomembrane shall be supplied as a continuous sheet with no factory seams in rolls. The IDS geomembrane will meet the property requirements as shown in (GRI GM for HDPE) or (GRI GM 17 for LLDPE). B. The IDS geomembrane shall be produced using a flat cast manufacturing process to create a structured geomembrane with inte- 4

grated drainage layer. The IDS geomembrane shall meet the properties listed in Table 1 of this section. 2.2 GEOTEXTILE A. A nonwoven fabric produced by needle-punching together 100% synthetic staple fibers, in a random network, forming a high strength, dimensionally stable fabric. Synthetic fibers specially formulated to resist ultraviolet light deterioration, and inert to commonly encountered soil chemicals. The synthetic fiber to be stable within a ph range of 2 to. Table 1: AGRU HDPE Super Gripnet Liner Tested Property Test Method Frequency Minimum Average Value 50 mil 60 mil 80 mil 100 mil Thickness, (minimum average) mil (mm) Lowest individual reading (-10%) ASTM D5994 every roll 50 (1.25) 45 (1.15) 60 (1.50) 54 (1.40) 80 (2.00) 72 (1.80) 100 (2.50) 90 (2.30) Transmissivity (m 2 /sec) ASTM D4716 500,000 SF 7.0 x 10-4 Drainage Stud Height, mil (mm) ASTM D7466 second roll 0 (3.30) 0 (3.30) 0 (3.30) 0 (3.30) Friction Stud Height, mil (mm) ASTM D7466 second roll 175 (4.45) 175 (4.45) 175 (4.45) 175 (4.45) Density, g/cm 3 ASTM D792, Method B 200,000 lb 0.94 0.94 0.94 0.94 Tensile Properties (each direction) Strength at Break, lb/in-width (N/mm) Strength at Yield, lb/in-width (N/mm) Elongation at Break, % Elongation at Yield, % ASTM D6693, Type IV Dumbell, 2 ipm G.L. 2.0 in (51 mm) G.L. 1.3 in (33 mm) 20,000 lb 110 (19) 110 (19) 200 2 (23) 2 (23) 200 176 (30) 176 (30) 200 220 (38) 220 (38) 200 Tear Resistance, lb (N) ASTM D1004 45,000 lb 38 (169) 42 (187) 56 (249) 70 (312) Puncture Resistance, lb (N) ASTM D4833 45,000 lb 80 (356) 90 (400) 120 (534) 150 (667) Carbon Black Content, % (Range) ASTM D4218 20,000 lb 2.0-3.0 2.0-3.0 2.0-3.0 2.0-3.0 Carbon Black Dispersion ASTM D5596 45,000 lb Note (1) Note (1) Note (1) Note (1) Notched Constant Tensile Load, hr ASTM D5397, Appendix 200,000 lb 500 500 500 500 Oxidative Induction Time, min ASTM D3895, 200 C; O 2, 1atm 200,000 lb >140 >140 >140 >140 NOTES: (1) Dispersion only applies to near spherical agglomerates. 10 views shall be Category 1 or 2. All AGRU geomembranes have dimensional stability of ±2% when tested according to ASTM D 1204 and LTB of <-77 C when tested according to ASTM D 746. Transmissivity at 21 C, gradient of 0.25, normal load of 250 psf, seat time 100 hr, boundary conditions: plate/sand/8 oz nonwoven geotextile/ids geomembrane/plate 5

Table 2: AGRU HDPE Drain Liner Tested Property Test Method Frequency Minimum Average Value 50 mil 60 mil 80 mil 100 mil Thickness, (minimum average) mil (mm) Lowest individual reading (-10%) ASTM D5994 every roll 50 (1.25) 45 (1.15) 60 (1.50) 54 (1.40) 80 (2.00) 72 (1.80) 100 (2.50) 90 (2.30) Transmissivity (m 2 /sec) ASTM D4716 500,000 SF 7.0 x 10-4 Drainage Stud Height, mil (mm) ASTM D7466 second roll 0 (3.30) 0 (3.30) 0 (3.30) 0 (3.30) Density, g/cm 3 ASTM D792, Method B 200,000 lb 0.94 0.94 0.94 0.94 Tensile Properties (each direction) Strength at Break, lb/in-width (N/mm) Strength at Yield, lb/in-width (N/mm) Elongation at Break, % Elongation at Yield, % ASTM D6693, Type IV Dumbell, 2 ipm G.L. 2.0 in (51 mm) G.L. 1.3 in (33 mm) 20,000 lb 110 (19) 110 (19) 2 (23) 2 (23) 176 (30) 176 (30) 220 (38) 220 (38) Tear Resistance, lb (N) ASTM D1004 45,000 lb 38 (169) 42 (187) 56 (249) 70 (312) Puncture Resistance, lb (N) ASTM D4833 45,000 lb 80 (356) 95 (422) 126 (560) 158 (703) Carbon Black Content, % (Range) ASTM D4218 20,000 lb 2.0-3.0 2.0-3.0 2.0-3.0 2.0-3.0 Carbon Black Dispersion ASTM D5596 45,000 lb Note (1) Note (1) Note (1) Note (1) Notched Constant Tensile Load, hr ASTM D5397, Appendix 200,000 lb 500 500 500 500 Oxidative Induction Time, min ASTM D3895, 200 C; O 2, 1atm 200,000 lb >140 >140 >140 >140 NOTES: (1) Dispersion only applies to near spherical agglomerates. 10 views shall be Category 1 or 2. All AGRU geomembranes have dimensional stability of ±2% when tested according to ASTM D 1204 and LTB of <-77 C when tested according to ASTM D 746. Transmissivity at 21 C, gradient of 0.25, normal load of 250 psf, seat time 100 hr, boundary conditions: plate/sand/8 oz nonwoven geotextile/ids geomembrane/plate. 6

Table 3: AGRU HDPE MicroDrain Liner Tested Property Test Method Frequency Minimum Average Value 50 mil 60 mil 80 mil 100 mil Thickness, (minimum average) mil (mm) Lowest individual reading (-10%) ASTM D5994 every roll 50 (1.25) 45 (1.15) 60 (1.50) 54 (1.40) 80 (2.00) 72 (1.80) 100 (2.50) 90 (2.30) Transmissivity (m 2 /sec) ASTM D4716 500,000 SF 7.0 x 10-4 Drainage Stud Height, mil (mm) ASTM D7466 second roll 0 (3.30) 0 (3.30) 0 (3.30) 0 (3.30) MicroSpike Asperity Height, mil (mm) ASTM D7466 second roll 20 (0.51) 20 (0.51) 18 (0.46) 18 (0.46) Density, g/cm 3 ASTM D792, Method B 200,000 lb 0.94 0.94 0.94 0.94 Tensile Properties (each direction) Strength at Break, lb/in-width (N/mm) Strength at Yield, lb/in-width (N/mm) Elongation at Break, % Elongation at Yield, % ASTM D6693, Type IV Dumbell, 2 ipm G.L. 2.0 in (51 mm) G.L. 1.3 in (33 mm) 20,000 lb 110 (19) 110 (19) 2 (23) 2 (23) 176 (30) 176 (30) 220 (38) 220 (38) Tear Resistance, lb (N) ASTM D1004 45,000 lb 38 (169) 42 (187) 56 (249) 70 (312) Puncture Resistance, lb (N) ASTM D4833 45,000 lb 80 (356) 95 (422) 126 (560) 158 (703) Carbon Black Content, % (Range) ASTM D4218 20,000 lb 2.0-3.0 2.0-3.0 2.0-3.0 2.0-3.0 Carbon Black Dispersion ASTM D5596 45,000 lb Note (1) Note (1) Note (1) Note (1) Notched Constant Tensile Load, hr ASTM D5397, Appendix 200,000 lb 500 500 500 500 Oxidative Induction Time, min ASTM D3895, 200 C; O 2, 1atm 200,000 lb >140 >140 >140 >140 NOTES: (1) Dispersion only applies to near spherical agglomerates. 10 views shall be Category 1 or 2. All AGRU geomembranes have dimensional stability of ±2% when tested according to ASTM D 1204 and LTB of <-77 C when tested according to ASTM D 746. Transmissivity at 21 C, gradient of 0.25, normal load of 250 psf, seat time 100 hr, boundary conditions: plate/sand/8 oz nonwoven geotextile/ids geomembrane/plate. 7

Table 4: AGRU LLDPE Super Gripnet Liner Tested Property Test Method Frequency Minimum Average Value 50 mil 60 mil 80 mil 100 mil Thickness, (minimum average) mil (mm) Lowest individual reading (-10%) ASTM D5994 every roll 50 (1.25) 45 (1.15) 60 (1.50) 54 (1.40) 80 (2.00) 72 (1.80) 100 (2.50) 90 (2.30) Transmissivity (m 2 /sec) ASTM D4716 500,000 SF 7.0 x 10-4 Drainage Stud Height, mil (mm) ASTM D7466 second roll 0 (3.30) 0 (3.30) 0 (3.30) 0 (3.30) Friction Stud Height, mil (mm) ASTM D7466 second roll 175 (4.45) 175 (4.45) 175 (4.45) 175 (4.45) Density, g/cm 3 ASTM D792, Method B 200,000 lb 0.939 0.939 0.939 0.939 Tensile Properties (each direction) Strength at Break, lb/in-width (N/mm) Elongation at Break, % ASTM D6693, Type IV Dumbell, 2 ipm G.L. 2.0 in (51 mm) 20,000 lb 105 (18) 126 (22) 168 (29) 210 (36) Tear Resistance, lb (N) ASTM D1004 45,000 lb 30 (3) 40 (178) 53 (236) 67 (298) Puncture Resistance, lb (N) ASTM D4833 45,000 lb 55 (245) 70 (311) 90 (400) 110 (489) Carbon Black Content, % (Range) ASTM D4218 20,000 lb 2.0-3.0 2.0-3.0 2.0-3.0 2.0-3.0 Carbon Black Dispersion ASTM D5596 45,000 lb Note (1) Note (1) Note (1) Note (1) Notched Constant Tensile Load, hr ASTM D5397, Appendix 200,000 lb 500 500 500 500 Oxidative Induction Time, min ASTM D3895, 200 C; O 2, 1atm 200,000 lb >140 >140 >140 >140 NOTES: (1) Dispersion only applies to near spherical agglomerates. 10 views shall be Category 1 or 2. All AGRU geomembranes have dimensional stability of ±2% when tested according to ASTM D 1204 and LTB of <-77 C when tested according to ASTM D 746. Transmissivity at 21 C, gradient of 0.25, normal load of 250 psf, seat time 100 hr, boundary conditions: plate/sand/8 oz nonwoven geotextile/ids geomembrane/plate. 8

Table 5: AGRU LLDPE MicroDrain Liner Tested Property Test Method Frequency Minimum Average Value 50 mil 60 mil 80 mil 100 mil Thickness, (minimum average) mil (mm) Lowest individual reading (-10%) ASTM D5994 every roll 50 (1.25) 45 (1.15) 60 (1.50) 54 (1.40) 80 (2.00) 72 (1.80) 100 (2.50) 90 (2.30) Transmissivity (m 2 /sec) ASTM D4716 500,000 SF 7.0 x 10-4 Drainage Stud Height, mil (mm) ASTM D7466 second roll 0 (3.30) 0 (3.30) 0 (3.30) 0 (3.30) MicroSpike Asperity Height, mil (mm) ASTM D7466 second roll 20 (0.51) 20 (0.51) 18 (0.46) 18 (0.46) Density, g/cm 3 ASTM D792, Method B 200,000 lb 0.939 0.939 0.939 0.939 Tensile Properties (each direction) Strength at Break, lb/in-width (N/mm) Elongation at Break, % ASTM D6693, Type IV Dumbell, 2 ipm G.L. 2.0 in (51 mm) 20,000 lb 105 (18) 126 (22) 168 (29) 210 (36) Tear Resistance, lb (N) ASTM D1004 45,000 lb 30 (3) 40 (178) 53 (236) 67 (298) Puncture Resistance, lb (N) ASTM D4833 45,000 lb 55 (245) 70 (311) 90 (400) 110 (489) Carbon Black Content, % (Range) ASTM D4218 20,000 lb 2.0-3.0 2.0-3.0 2.0-3.0 2.0-3.0 Carbon Black Dispersion ASTM D5596 45,000 lb Note (1) Note (1) Note (1) Note (1) Notched Constant Tensile Load, hr ASTM D5397, Appendix 200,000 lb 500 500 500 500 Oxidative Induction Time, min ASTM D3895, 200 C; O 2, 1atm 200,000 lb >140 >140 >140 >140 NOTES: (1) Dispersion only applies to near spherical agglomerates. 10 views shall be Category 1 or 2. All AGRU geomembranes have dimensional stability of ±2% when tested according to ASTM D 1204 and LTB of <-77 C when tested according to ASTM D 746. Transmissivity at 21 C, gradient of 0.25, normal load of 250 psf, seat time 100 hr, boundary conditions: plate/sand/8 oz nonwoven geotextile/ids geomembrane/plate. 9

Table 6: AGRU LLDPE Drain Liner Tested Property Test Method Frequency Minimum Average Value 50 mil 60 mil 80 mil 100 mil Thickness, (minimum average) mil (mm) Lowest individual reading (-10%) ASTM D5994 every roll 50 (1.25) 45 (1.15) 60 (1.50) 54 (1.40) 80 (2.00) 72 (1.80) 100 (2.50) 90 (2.30) Transmissivity (m 2 /sec) ASTM D4716 500,000 SF 7.0 x 10-4 Drainage Stud Height, mil (mm) ASTM D7466 second roll 0 (3.30) 0 (3.30) 0 (3.30) 0 (3.30) Density, g/cm 3 ASTM D792, Method B 200,000 lb 0.939 0.939 0.939 0.939 Tensile Properties (each direction) Strength at Break, lb/in-width (N/mm) Elongation at Break, % ASTM D6693, Type IV Dumbell, 2 ipm G.L. 2.0 in (51 mm) 20,000 lb 105 (18) 126 (22) 168 (29) 210 (36) Tear Resistance, lb (N) ASTM D1004 45,000 lb 30 (3) 40 (178) 53 (236) 67 (298) Puncture Resistance, lb (N) ASTM D4833 45,000 lb 55 (245) 70 (311) 90 (400) 110 (489) Carbon Black Content, % (Range) ASTM D4218 20,000 lb 2.0-3.0 2.0-3.0 2.0-3.0 2.0-3.0 Carbon Black Dispersion ASTM D5596 45,000 lb Note (1) Note (1) Note (1) Note (1) Oxidative Induction Time, min ASTM D3895, 200 C; O 2, 1atm 200,000 lb >140 >140 >140 >140 NOTES: (1) Dispersion only applies to near spherical agglomerates. 10 views shall be Category 1 or 2. All AGRU geomembranes have dimensional stability of ±2% when tested according to ASTM D 1204 and LTB of <-77 C when tested according to ASTM D 746. Transmissivity at 21 C, gradient of 0.25, normal load of 250 psf, seat time 100 hr, boundary conditions: plate/sand/8 oz nonwoven geotextile/ids geomembrane/plate. B. Extrudate Rod or Bead 1. Extrudate material shall be made from same type resin as the geomembrane. 2. Additives shall be thoroughly dispersed. 3. Materials shall be free of contamination by moisture or foreign matter. 2.3 SHEAR STRENGTH A. The IDS geomembrane shall exhibit minimum shear strength characteristics along each interface. These characteristics shall be demonstrated with direct shear testing (ASTM D5321) by an independent CQA laboratory. B. The minimum design shear strength at each normal stress tested shall be as listed below and determined by test conditions noted: 10

Minimum Required Shear Force (psf) Geomembrane Interface Shear Interface Tested Applied Normal Load (psf) Peak or Large-Displacement 1. Tests shall be conducted using sandwich configuration with proposed soils above and below geosynthetic system being tested. 2. Test under submerged condition. 3. Use a shearing rate of 0.04 in./min. 4. The spikes and studs shall remain intact under the above test conditions (no peeling or shearing). 2.4 GEOMEMBRANE INSTALLATION A. Installation of the geomembrane shall follow the most recent version of the International Association of Geosynthetic Installer s Guideline for Installation of: HDPE and LLDPE Geomembrane Installation Specification (Exhibit 1) B. Project specific geomembrane installation requirements listed below: 2.5 FIELD SEAMING GEOTEXTILE COMPONENT A. Geotextiles will be generally aligned with seams parallel to the prevailing slope and HEAT TREATED side of the geotextile to be face down in contact with the IDS Geomembrane drainage studs and can be seamed by either heat seaming with an approved hand held or self-propelled thermal device or by sewing with a stitching approved by the engineer. B. Any holes, tears, or burn through from thermal seaming in geotextiles will be repaired by patching with the same geotextiles. The patch will be a minimum of twelve inches (12 /30cm) larger in all directions than the area to be repaired and will be spot bonded thermally. 11

Subject to errors of typesetting, misprints and modifications. Illustrations are generic and for reference only. AGRU America 500 Garrison Road Georgetown, SC 29440 USA T. +1 800 373 2478 F. +1 843 527 2738 salesmkg@agruamerica.com Revision Date: September 5, 2017 12:55 PM