Experimental study of air evaporative cooling process using microporous membranes

Similar documents
Impact of indirect evaporative air cooler type on the performance of desiccant systems

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Two Stage Indirect/Direct Evaporative Cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Effect of operating conditions on performance of silica gel-water air-fluidised desiccant cooler

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Investigation of an evaporative air cooler using solar energy under Algerian climate

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Applied Thermal Engineering

Dynamic performance of a novel dew point air conditioning for the UK buildings

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

ANALYSIS OF THE MAISOTSENKO CYCLE BASED COOLING SYSTEM FOR ACCUMULATOR BATTERIES

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Modified Air Cooler with Split Cooling Unit

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

ω = (1) Kirby S. Chapman Ph.D.

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Heat pump and energy recovery systems

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

UNIT 1 AIR CONDITIONING 1. Write the various psychometric processes? Explain any four processes with neat sketches?

Oxyvap Evaporative Cooling Applications

SCIENCE CHINA Technological Sciences

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Compression of Fins pipe and simple Heat pipe Using CFD

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

A review on Efficient Technique of Air-Conditioning Rajesh Kumar, Pravesh Mishra, Ram Raja

Recent Advances in Energy, Environment and Economic Development

Scholars Research Library

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Design of solar adsorption refrigeration system with CPC and study on the heat and mass transfer performance

Thermodynamics II Chapter 6 Mixtures & Psychrometry

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Theoretical Performance Analysis Of Direct Evaporative Cooler In Hot And Dry Climates

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

EXPERIMENTAL INVESTIGATION OF DIRECT EVAPORATIVE COOLER WITH HEMP AND ABACA COOLING PAD MATERIAL

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Energy and Exergy Analysis of an Ejector-Absorption Refrigeration Cycle with Using NH3-H2O as the Working Fluids

Measurement of internal pressure and thermal performance in a closed-loop oscillating heat-pipe with check valves (CLOHP/CV)

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

Desiccant-enhanced evaporative (DEVap) cooler system introduction and its comparison with direct expansion (DX) system

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Performance of an Improved Household Refrigerator/Freezer

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

NEBRASKA MODIFIED ROOF POND: 1985 SUMMER PERFORMANCE RESULTS

Testing and Performance Analysis of a Hollow Fibre-Based Core for Evaporative Cooling and Liquid Desiccant Dehumidification

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Performance of solid desiccant-based evaporative cooling system under the climatic zones of India

EXPERIMENTAL STUDY OF AIR FLOW RATE EFFECTS ON HUMIDIFICATION PARAMETERS WITH PREHEATING AND DEHUMIDIFICATION PROCESS CHANGING

METHODS FOR ANALYZING THE ENERGY EFFICIENCY AND COST EFFECTIVENESS OF EVAPORATIVE COOLING AIR CONDITIONING

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

EXPERIMENTAL STUDY ON THE LOOP HEAT PIPE OPERATING UNDER HORIZONTAL ORIENTATION

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Optimizing Electric Humidifier Operation with an Air Side Economizer

A study of tea leaves drying using dehumidification process and regeneration of liquid desiccant in a closed-cycle dehumidification-humidification

DESIGN AND FABRICATION OF AN EVAPORATIVE COOLING SYSTEM. Md. Rakibuzzaman 1,* and M. A. Wazed 2. Chittagong-4349, Bangladesh 1,*

Performance Of The Dehumidification Cycle Of A 3-Fluid Liquid Desiccant Membrane Air-Conditioning System

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Department of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics

STUDYING THE PERFORMANCE OF A COUNTER-FLOW, VERTICAL EVAPORATIVE HUMIDIFIER

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

High Efficiency Heat Pump for Domestic Hot Water Generation

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Design and Development of Combined Direct and Indirect Evaporative Cooling System

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Optimisation of cooling coil performance during operation stage for improved humidity control

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Transcription:

Experimental study of air evaporative cooling process using microporous membranes Sebastian Englart 1,* 1 Wrocław University of Science and Technology, Faculty of Environmental Engineering, Department of Air Conditioning, Heating, Gas Engineering and Air Protection, ul. Norwida 4/6, 50-373 Wrocław, Abstract. This article describes the potential use of microporous membranes in evaporative cooling applications for air conditioning. The structure of membrane contractor and the measuring device are described. On the basis of the results of the measurements air cooling effectiveness coefficient has been determined. 1 Introduction Evaporative cooling is an air cooling method which uses the heat of vaporization of water. Numerous studies analyzed the possibilities of using the evaporative cooling in various options, to maintain comfort conditions in living quarters and to lower air temperature in industrial facilities [1]. This type of air cooling can be characterized by less energy consumption compared to conventional solutions used in air conditioning [2 10]. The disadvantages of evaporative cooling include dependence on the outside air parameters and the lack of possibility of air drying. In the case of direct cooling (DEC) an additional disadvantage is also a direct contact with water. To avoid direct contact of air with water, Johnson et al. [11] proposed the use of membranes for this process. Such a solution is intended to prevent the passage of bacteria, including Legionella, from water to air. The use of a synthetic membrane, which is a porous, semi-permeable barrier between the liquid and the air, allows for a kind of semi-direct evaporative cooling (SDEC). Membranes are currently used in various industries for separation processes. They may also be used in heating, ventilation and air conditioning (HVAC) systems for various processes such as air treatment, for example: dehumidification or humidification or the evaporative cooling in question [12 19]. The results of experimental research on air evaporative cooling using the membrane module will be presented later in the article. 2 Performance indices While evaluating and selecting the method of evaporative cooling a few indicators should be taken into account. One of the indicators that can be used to compare devices and * Corresponding author: sebastian.englart@pwr.edu.pl The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

processes of air evaporative cooling is their effectiveness. Besides the effectiveness criterion, also the energetic aspect of the evaporative cooling is important. 2.1 Effectiveness The evaporative cooling has its limitations resulting from the ability of the air to absorb moisture. Those maximum capabilities are clearly determined by the temperature of the air that is being humidified, the amount of moisture in it and the atmospheric pressure. The equipment efficiency is determined by the real air cooling effectiveness. The effectiveness of the heat exchange can be defined as a relation of the temperature difference in one of the fluids to the difference of temperatures on the heat exchanger inlet. Thus for the water and air membrane heat exchanger the effectiveness can be represented by the following equation: t t d1 d 2 tw (1) td1 tw1 In the studies [18, 19], where the membrane module was used, the above equation was proposed to determine the effectiveness of the sensible cooling. In order to compare commercial evaporative coolers the following saturation effectiveness indicator is used [20]: t t d1 d 2 twb (2) td1 twb1 For some structural solutions for the evaporative coolers the dew point effectiveness is determined [8]: t t d1 d 2 tdp (3) td1 tdp1 2.2 Energy efficiency ratio The energy effectiveness of cooling equipment can also be determined using the energy effectiveness ratio (EER). For the complete thermal load the EER indicator is determined as a ratio of the cooling power to the electrical power consumption: Qc EER (4) P This indicator is used to compare the efficiency of air conditioning equipment. Taking into account only a drop in the outside air temperature, the cooling power of the direct evaporative cooler can be calculated using the following formula [21]: Q c mac pa td1 td 2 (5) The main energy expenditures associated with the membrane semi-direct evaporative cooling (SDEC) operation result from the air and water transport. Hence, the demand for electrical power for the air transport can be represented by the following formula: 2

mapm Pa (6) a For the water transport pumping system: mwp p Pw (7) w The total demand for electrical power for the evaporative cooling operation using the membrane module, will amount to: P P a P w (8) For the direct evaporative coolers Watt [21] proposed the introduction of the following parameter: UC Q c (9) td1 twb1 The unit cooling UC determines the relation of the sensible heat removed from air to the temperature difference (entering air wet bulb depression). Consequently it becomes possible to eliminate the influence of external weather conditions and to bring the comparison to a common base. Watt [21] also proposed the introduction of evaporative EER indicator to the direct evaporative cooling: UC eeer (10) P 2.3 Required parameters of the indoor air It is necessary to evaluate the influence of an evaporating cooling device on the quality of the indoor microclimate of the premises. The air parameters (temperature, humidity) obtained by means of the evaporative cooler and the conditions required in the room will determine the applicability of the solution. In the areas intended for permanent human stay, specific temperatures, relative humidity and air speed are required, depending on the season and physical activity of the people. The appropriate air parameters are to ensure thermal comfort of the people using the room. The ASHRAE comfort zone for the summer period [1] is indicated on the psychometric chart (Fig.1). Skrzyniowska [22] indicates that the optimum values of the indoor air for the summer period are as follows: temperature 18 26 C, relative humidity 40 60%, maximum air speed of 0.3 0.6 m/s. The closer range of those values should be determined after taking into account physical activity of the people inside. The limits of air in the ventilated facilities without the possibility of cooling can amount up to 70% of the relative humidity and 3 to 5 C of the temperature above the ambient temperature. In industrial spaces, the air parameters in a room (temperature, relative humidity) will often be subordinated to the technological processes conducted there. One of the methods for determining the cooling capacity of the environment can be the effective temperature. This is a fictitious temperature to which combinations of temperature, humidity and air speed correspond. Such combinations should give the same feeling of comfort. A fragment of the nomogram for determining effective temperatures, with the marked zone of comfort for the summer period is included in Figure 2. It has been developed on the basis of [22]. 3

Fig. 1. ASHRAE comfort zone [1] with examples of changes of air in a pilot plant for the semi-direct evaporative cooling. Fig. 2. The cooling capacity of air in the monogram of effective temperatures (developed on the basis of [22]). 3 Experimental setup For the process of semi-direct evaporative cooling (SDEC), a membrane module with a capillary membrane of polypropylene (PP) was used. The parameters of the membrane were as follows: the inner diameter of the membrane of 1.67 mm, the outer diameter of the 4

membrane of 2.71 mm, the average pore diameter of 0.43 m, the maximum pore size of 0.55 m. In the module, 744 membranes of a total surface area of 3.04 m 2 and a packing density of 667 m 2 /m 3 were used. The membranes were situated perpendicularly to the air flow direction (fig. 3). Fig. 3. View of membranes in the module. Fig. 4. Schematic diagram and view of the test bench. F-fan, MO-measuring orifice, Ro-rotameter, R-recorder, WT-water reservoir, M-membrane module, Pu-pump, Reg-thyristor controller, sensors of: t temperature, humidity, Δp differential pressure. To evaluate the effectiveness of the evaporative cooling, where the membrane module had been applied the measurements were taken on the test bench which is shown in Figure 4. The measuring bench was equipped with devices for measuring the following parameters: - outdoor air temperature and humidity, - air temperature and humidity at the inlet and outlet of the membrane module, - the air flow rate in the duct, - temperature of water upstream and downstream the module, 5

- the water flow rate. The measurements were performed at constant flow of air and a variable flow of water. The air flow was 95 m 3 /h. The water flow through the internal part of capillaries, forced with a pump, ranged from 50 kg/h to 200 kg/h. The sample air changes obtained in the pilot plant during the tests are shown on the psychometric diagram (Fig. 1). Points 1, 3, 5, 7 determine the air parameters before the module (outside air), points 2, 4, 6, 8 represent the state of the air after cooling in the membrane module. 4 Results and discussion In the process of semi-direct evaporating cooling which was tested in the module the temperature decreased and the humidity increase simultaneously. The air changes indicated in Fig. 1 show that the evaporative cooling in the tested unit was insufficient to maintain comfort conditions. After taking into account the potential heat gains in the room, further cooling of the air to the required inlet air temperatures will be necessary. In the case of 1 2, and 5 6 changes, after the application of further cooling, it is possible to obtain the air inlet temperature which ensures thermal comfort without dehumidification. The solution with the initial evaporative cooling can be operated as supportive for conventional air coolers. In the case of 7 8 changes, it is also possible to obtain a relatively favorable cooling effect related to the effective temperature. Fig. 2 includes the lines presented as numbers 1, 2, 7, 8, which link the dry and wet bulbs scale. The line numbers correspond to the air parameters before and after the module, according to the numbering of the points in Fig. 1. The intersection of each line between the air speed curves determines the effective temperature for a particular speed. In the case 1 and 2 both the outside air and the cooled air fall within the limits prescribed for the summer period. In the case 7 and 8 the correct effective temperature, on condition that the minimum speed of the air is 1 m/s, can be obtained only after cooling the air in the membrane module. In the absence of classic air cooling, the use of the semi-direct evaporative cooling may, in some cases, improve the parameters of the air in the room in comparison to other rooms ventilated only with the outside air. Such a solution can be applied to partially improve the microclimate of industrial premises where there is no need to ensure thermal comfort conditions. The effectiveness were determined based on the equations (1 3). Fig. 5 shows the results obtained for an exemplary measurements series, with respect to the pilot plant operation time. The values obtained are somewhat lower than in the case of classical direct evaporative cooling, but comparable to the processes where the membranes are used [18, 23]. The changes in the rate of water flow through the module, within the range of the stream variation, caused no significant changes in the temperature effectiveness. A similar effect was observed at study [23]. Instead, Johnson et al. [11] proposed resignation from the circulating pump to replace it with the gravitational flow of water into the membrane module. EER and eeer indicators set by equations (4) and (10) are presented in Fig. 6. The obtained EER for the presented measurement series averaged from 13.6 to 18.5 and the eeer from 1.10 to 1.41. With the water flow decreasing, the demand for electric energy for the water pumping decreased, and thus the increase of EER and eeer was possible. In the case of conventional air conditioners the most effective units are characterized by EER of approximately 3.20. According to ASHRAE [1], EER for the two-stage indirect-direct evaporative cooling range between 3.7 11.3. For the analyzed solution Bruno [8] obtained an average value of 11.5 ratio with top temporary values reaching 13. 6

Fig. 5. Changes in the effectiveness and the water flow during the system operation. Fig. 6. Changes of EER, eeer indicators and the water flow during the system operation. 5 Conclusions In the air conditioning technology drying the air is not always necessary to maintain its appropriate parameters. The semi-direct evaporative cooling results in the increase of air humidity which may limit applicability of the device. The direct evaporative cooling where the membrane module is used can be applied in hot and dry climate conditions. It can also be used as a supportive solution, cooperating with classic solutions, in temperate climates in periods of low relative humidity (approximately 40%). Moreover the use of the membranes makes it possible to achieve satisfactory temperature coefficient and satisfactory energy effectiveness factors. 7

Nomenclature c p specific heat (J/(kgK)) EER energy efficiency ratio (W/W) eeer evaporative EER ((W/W)/K) m mass flow rate (kg/s) P total electric power demand (W) t temperature (K ) Q c cooling capacity (W) UC unit cooling (W/K) p m pressure drop in membrane module (Pa) p p pump delivery head (Pa) effectiveness density ( kg/m 3 ) device efficiency Subscripts: 1 inlet, 2 outlet, a air, d dry bulb, dp dew point, wb wet bulb, w water References 1. ASHRAE, Handbook of HVAC Applications (ASHRAE, Atlanta, GA, USA, 2011) 2. G. Heidarinejad, M. Bozorgmehr, S. Delfani, J. Esmaeelian, Build. Environ. 44, 2073 2079 (2009) 3. G. Heidarinejad, M. Heidarinejad, S. Delfani, J. Esmaeelian, Energ. Buildings, 40, 1946 1953 (2008) 4. G. Chiesa, M. Grosso, Build. Environ. 94, 263 272 (2015) 5. J. R. Camargo, C. D. Ebinuma, J. L. Silveira, Int. J. Refrig. 28, 1124 1132 (2005) 6. C. Lertsatitthanakorn, S. Rerngwongwitaya, S. Soponronnarit, Biosyst. Eng. 93, 213 219 (2006) 7. H. Caliskan, I. Dincer, A. Hepbasli, Energ. Buildings 43, 1461 1472 (2011) 8. F. Bruno, Energ. Buildings 43, 3475 3483 (2011) 9. S. Anisimov, D. Pandelidis, J. Danielewicz, Energy 80, 452 464 (2015) 10. H.T. El-Dessouky, H.M. Ettouney, W. Bouhamra, Trans. Inst. Chem. Eng. A 78, 999 1009 (2000) 11. D. W. Johnson, C. Yavuzturk, J. Pruis, J. Membr. Sci. 227, 159 171 (2003) 12. J. Woods, Renew. Sust. Energ. Rev. 33, 290 304 (2014) 13. S. Bergero, A. Chiari, Appl. Therm. Eng. 21, 1119 1135 (2001) 14. S. Bergero, A. Chiari, Energ. Buildings, 42, 1976 1986 (2010) 15. S. Bergero, A. Chiari, Energy 36, 5261 5273 (2011) 16. C. Isetti, E. Nannei, A. Magrini, Energ. Buildings 25, 185 193 (1997) 17. N. T. Charles, D. W. Johnson, J. Membr. Sci. 319, 44 53 (2008) 18. L.Z. Zhang, Z.X. Li, T.S. Zhong, L.X. Pei, J. Membr. Sci. 427, 1 9 (2013) 19. L.Z. Zhang, Int. J. Heat. Mass. Tran. 55, 5861 5869 (2012) 20. L.Z. Zhang, Energy 31, 1228 1242 (2006) 21. J. R. Watt, Evaporative Air Conditioning Handbook (Chapman and Hall, New York, 1986) 22. D. Skrzyniowska, Cz. T. Environment Engineering 28, 3, 15 35 (2012) 23. L.Z. Zhang, S.M. Huang, Int. J. Heat. Mass. Tran. 54, 1055 1063 (2011) 8