Product Alert September 20, 2012

Similar documents
SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SPECIFICATION: ARGONITE Engineered Fire Suppression System

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

Badger Universal Control Head

SECTION FM-200 FIRE SUPPRESSION SYSTEM

PRODUCT MANAGEMENT BULLETIN# 171b

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

FM-200 In-Cabinet Series

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

DETECT-A-FIRE Heat Detectors

esfr pendent sprinkler vk510 (k25.2)

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

TECHNICAL DATA NOTICE

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

Spark Electrodes/Flame Sensors

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

CORE Protection Fire System Specification

Hospitals and Major Medical Centers

JUL 17 Rev C

TECHNICAL DATA OBSOLETE

CERTIFICATE OF FIRE APPROVAL

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

Superior by Design The Kidde ADS TM FM-200 System

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

WORMALD INTERNATIONAL ELECTRIC VALVE ACTUATOR

12 Ton Hydraulic Crimping Head, PN

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

SERVICE INSTRUCTION SI0035 Rev NC Page 1 of 3

Settlement Agreement. Schedule 1: Covered Products

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

SAFETY THE BEST FOR YOUR EQUIPMENT

Audi-Larm Audible Alarm

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Data/ Specification Sheet

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Worldwide Contacts.

SuperKlean Washdown Products

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

esfr pendent sprinkler vk510 (k25.2)

AD Technical Bulletin

Field Adjuster s Evidence Submission Checklist General Info All Claims

TECHNICAL INSTRUCTIONS

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

PriceList Category PartNbr Part Description Weight (l MSRP

Capital Projects Group Fire Extinguishers Specification

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

Hydraulic Crimping Head, PN

FIRE SUPPRESSION SYSTEM

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

TECHNICAL DATA. Wet 26a. February 22, 2009

esfr dry pendent sprinkler Vk501 (k14.0)

Sprinkler Identification Numbers

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Internal Operating Procedure ISO 9001:2008 SOC NEVADA LLC

TECHNICAL INSTRUCTIONS

5700-E Sediment Filter Installation & Start-Up Guide

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

TECHNICAL INSTRUCTIONS

! WARNING. Before using product, read and understand instructions.

Models Series Series

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Heat Exchanger Tube Change Procedure

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007

Types of Detection. Fusible Link Detection - Most Common

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

esfr dry pendent sprinkler Vk502 (k14.0)

DYNA-CRIMP* Hydraulic Crimping Head, PN 69099

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Models Series Series

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Hydraulic Crimping Heads and

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Transcription:

Product Alert September 20, 2012 Type of Notification: Performance Related Concern FM Approvals has been made aware of a potential issue with Chemetron Fire System s Carbon Dioxide System Discharge Hose (P/N 50260263). The brass ferrule that attaches the male coupling to the hose may exhibit cracking that can cause the hose to fail under pressure. Company Identity: Chemetron Fire Systems Address: c/o Kidde-Fenwal, Inc. 400 Main Street Ashland, MA 01721 Contact information: Mr. Richard Karadizian, Mechanical Engineering Manager Product Identity: Carbon Dioxide Extinguishing System Description: ½ Carbon Dioxide System Discharge Hose Make/Model: P/N 50260263 Nameplate data: N/A FM Approval status: FM Approved Hazard Involved: If the ½ Carbon Dioxide system discharge hose exhibits a crack along the length of the brass ferrule on either end, it may disconnect on discharge causing the fire suppression system to not operate properly for suppression. As set out in Chemtron s Bulletin, this may also pose a life safety risk if Carbon Dioxide discharges into an occupied space. Refer to the attached documents for further details regarding direction for inspection, identification and replacement. Enclosures: Chemetron Bulletin 11-61C Chemetron Bulletin 12-25C F 900/Rev. 0

Bulletin #11-61C Date: December 1, 2011 To: From: Subject: Chemetron Fire Systems Distributors Joseph Ciol, Product Manager Safety Bulletin 50260263 ½ inch CO2 Discharge Hose Important Safety Notice - Please Read And Act Immediately We are issuing this safety bulletin to make you aware of a potential issue with the Chemetron 1/2 (nominal) CO2 discharge hose, part number 50260263. 1/2 CO2 discharge hoses shipped between June 2010 and March 2011 may exhibit a crack along the brass ferrule that attaches the male coupling to the hose. These hoses must be visually inspected at the earliest opportunity. To determine if the hose you have purchased exhibits a crack, visually inspect the ferrule to determine whether any longitudinal cracks are present. The pictures below are for your reference. If the 1/2 CO2 discharge hose exhibits a crack of ANY length along the length of the brass ferrule on either end, it may disconnect on discharge causing the fire suppression system to not operate properly for suppression. It may also pose a life safety risk if CO2 discharges in an occupied space. Male Coupling Male Coupling Braided Hose Braided Hose Brass Ferrule (Continuous) Brass Ferrule (Cracked) Example of correct ferrule condition The brass ferrule is continuous (unbroken) around the entire circumference. Example of incorrect ferrule condition (worst case complete longitudinal crack) A crack or split of ANY length along the ferrule body on either end of the hose is cause for replacement. 2011 Kidde-Fenwal, Inc. All Rights Reserved

Action On Your Part 1. Check your inventory and make the necessary arrangements to inspect hoses installed at your customer sites. A hose that exhibits a crack or split of ANY length along the ferrule body on either end of the discharge hose must be replaced immediately. An inspection mirror may be required to view the entire surface of the ferrule. Note: Hoses shipped between June 2010 and March 2011 have two distinct configurations. Only Configuration A is subject to the instructions outlined in this communication. Configuration B need not be replaced and may remain in service, subject to the standard inspection and test procedures per NFPA and/or other relevant codes and standards. REPLACE NO ACTION REQUIRED Configuration A No marking on the coupling hex Configuration B Supplier Identifier marking on the coupling hex 2. Hoses shipped between June 2010 and March 2011, that do not exhibit a crack along the ferrule but have no marking on the coupling hex (See Configuration A above), must be replaced at the next service interval. Hoses removed from service must be rendered inoperative and disposed of to avoid the possibility of reuse. This can be achieved by cutting the hose in half or the removal of one of the fittings. Once again, only hoses shipped between June 2010 and March 2011 meeting Configuration A (no marking on the coupling hex) need to be replaced per this bulletin. Hoses meeting Configuration B are not subject to this bulletin. 3. Please contact your customer service representative at Chemetron (800-878-5631) to arrange for the replacement hoses via the RMA process. Replacement hoses will be provided in advance at no charge, upon request. We request that any cracked hoses found be returned to Chemetron for analysis. Any uncracked hoses which are replaced in accordance with this service bulletin should be rendered inoperative per the instructions above. Please notify us within 6 months of the quantity of hoses replaced in the field by completing the attached 61C High Pressure CO2 Discharge Hose Safety Upgrade Credit Claim Form. Upon proper completion of this form Chemetron will provide a labor credit of $200 per site visit. Providing Chemetron with this completed form is also necessary to prevent charging you back for the advanced replacement hoses.

4. Chemetron has identified the stock numbers and purchase orders for each hose purchased during this time frame and this list is included at the end of this service bulletin. Your Chemetron Customer Service Representative will be able to assist you with your purchase information, should you have additional questions. Please note that this discharge hose part number is used as a component in the assemblies listed below: 5. To accomplish the hose replacement follow standard procedure for disarming the system including removal of all the discharge heads in the system to avoid accidental discharge. Disassemble the Swivel Nut side of the hose first, leaving the Union Adaptor in the Discharge Head. Then remove the male end from the system piping. The new hose should then be assembled in the reverse order with the male fitting end first, then the swivel nut end into the union adaptor. Use a small amount of a good grade of pipe thread dope or Teflon tape on the threads when making these connections. Before connecting discharge heads to cylinders, make certain that the plungers of ALL discharge heads are in the non-actuated position (i.e., check the plunger to see that it is retracted). When the piston is in the non-actuated (retracted) position, the end of the plunger should be approximately 3/4 inside the bottom of the union nut. Reassemble the discharge heads. Discharge Head Swivel Nut Union Adapter left in Discharge Head

16 W 361 S Frontage Road Suite 125 Burr Ridge, Illinois 60527 (708) 748-1503 Bulletin #12-25C Date: July 13, 2012 To: From: Subject : All Chemetron Fire Systems Distributors Joe Ciol, Product Manager Reminder - Safety Bulletin 50260263 ½ inch CO2 Discharge Hose Important Safety Notice - Please Read And Act Immediately In December 2011, you received the attached safety notice, #11-61C. This notice advised you of a potential safety issue with the ½ inch high pressure discharge hose 50260263. If you have already complied with this notice and have completed all inspections, made all necessary replacements and have submitted your credit claim form, you may disregard this reminder. If you have not yet complied with this notice, please make every effort to identify, inspect and replace the hoses immediately. All of the ½ inch discharge hoses shipped between June 2010 and March 2011 without marking on the coupling head (see configuration A in the safety bulletin #11-61C) must be replaced. Advance replacement hoses will be provided at no charge. Also a $200.00 credit will be provided to you per site visit upon proper completion of a credit request form. Refer to the bulletin for details. Thank you for you attention to this important safety matter. If you have any questions or require additional information, please contact Technical Support at (708) 748-1503 or Joe Ciol, Product Manager at 508-231-2749. Main Fax (708) 748-2847 www.chemetron.com Chemetron trademark of Kidde-Fenwal, Inc.