Geothermal Training System (46126-A0)

Similar documents
Geothermal Training System

46126-A2 Geothermal Training System

3400-3A Refrigeration System Demonstrator

Refrigeration Training System

Lighting and Fire Alarm Training System Add- On ( )

Multi-Zone Wireless Control Training Systems ( )

Job Sheet 1. Geothermal Energy OBJECTIVES. Familiarization with the training system components PROCEDURE

EDS Solar Thermal ( )

Addressable Fire Alarm System Fire Alarm Training System

The Refrigeration Cycle

Shell-and-Tube Heat Exchanger (Four Passes) - Optional

Heat Exchangers and Advanced Temperature Measurement Temperature

The Refrigeration Cycle

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

ENGINEERING SPECIFICATIONS

Heat Pump Training Course 128 hours, 128 NATE CEHs, 12.8 CEUs Volume Pages, Volume Pages

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Jr. Tech (JT-1, 2, 3) Knowledge Areas

MU053: CHILLERS: Operation & Maintenance of Chilled Water Systems

ENGINEERING SPECIFICATIONS

Air Conditioning and Refrigeration

Preparing the Next Generation of Building Technicians

CHILLER. Operator s & Installation Manual

GUIDE SPECIFICATIONS AQUARIUS ii

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT HVAC MAINTENANCE TECHNOLOGY. Test Code: 5937 Version: 01

CHILLERS. Operator s & Installation Manual

GUIDE SPECIFICATIONS AQUARIUS ii

UEE11 Electrotechnology. Training Package. UEENEEJ104A Establish the Basic Operating Conditions of Air Conditioning Systems SAMPLE

EDUCATIONAL TRAINING UNITS

Air Distribution Systems

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

2. CURRICULUM. Sl. No.

MARINE SELF-CONTAINED DIRECT EXPANSION AIR CONDITIONING SYSTEMS

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Refrigeration and Air-conditioning Technology. Open- and closed-loop control in refrigeration and air-conditioning systems

Digital, not analog: One manifold for all refrigeration systems.

HT V2 HT Split

Engineering Bulletin Rev B. Contents. Piping Arrangements for Heat Pump Water Heating Systems

Refrigeration and Air Conditioning

MAC N-407 Air-Cooled Chiller

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

EHH SERIES DRAW THROUGH FAN COILS CFM

Reinventing Energy Efficiency

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

MACH N-407 Heat Pump Air-Cooled Chiller

Refrigeration/Troubleshooting Manual

Revised April High School Graduation Years 2016, 2017, and Unit/Standard Number

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

CH750, CH751 & CH951 CHILLERS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Electrical Faults in Air Conditioning Systems Unit TEFA

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

ASSIGNMENT OBJECTIVES

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

TECHNICAL NOTICE GH/GHO/GAE V

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

NQ Series Portable Chillers

Precise Temperature Control; Compact Footprint

BasicTroubleshooting Information and Guidelines

DISTRIBUTION SYSTEMS. Water Piping and Pumps

MAC-120HE-03 Air-Cooled Chiller

SECTION WATER-SOURCE UNITARY HEAT PUMPS

AHWG Remote Mount Hot Water Generator Module

INSTALLATION INSTRUCTIONS

SERVICING AND BREAKDOWN...

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

INSTALLATION INSTRUCTIONS

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

armfield COMPUTER CONTROLLED HEAT EXCHANGER SERVICE MODULE HT30XC series issue 2

Intermediate Refrigeration Systems for Operators

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

Training Fees 4,000 US$ per participant for Public Training includes Materials/Handouts, tea/coffee breaks, refreshments & Buffet Lunch.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Heat Pumps COMFORT NEED IT. When You

30GT FLOTRONIC AIR-COOLED CHILLERS

VertiCool Aurora Engineering Guide

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

IE Code IE Competency Title Credit OAC Ref.

Withlacoochee Technical College Syllabus Air-Conditioning, Refrigeration and Heating Technology HVAC / R

water to water heat pumps

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Heating, Air Conditioning, Ventilation and Refrigeration Maintenance Technology/Technician CIP Task Grid

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Technical Development Program

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

SYSTEM DESIGN REQUIREMENTS

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

30GN FLOTRONIC II AIR-COOLED CHILLERS

Transcription:

Geothermal Training System 582385 (46126-A0) LabVolt Series Datasheet Festo Didactic en 220 V - 60 Hz 03/2019

Table of Contents General Description 2 Geothermal Heat Pump 3 Ground-Loop Heat Exchanger 4 Domestic Hot Water System 4 Control Panels 5 Pumping Station 5 Troubleshooting 6 Courseware 6 Topic Coverage 6 Features & Benefits 7 List of Manuals 7 Table of Contents of the Manual(s) 7 Specifications 7 General Description The Geothermal Training System has been designed to maximize learning capabilities by regrouping every subsystem in real geothermal home energy installations. It teaches the fundamentals of heat transfer, refrigeration, and air conditioning applied to geothermal energy HVAC projects. It is suitable for varied educational requirements: future system designers and builders, maintenance technicians, and students learning the concept of energy efficiency. With its courseware containing detailed theory and practical exercises, the Geothermal Training System is the most efficient and effective way to acquire the knowledge and skills that are put into practice every day in the geothermal industry. Using components found exclusively on a real geothermal HVAC project, this robust training system is built on a mobile workstation sized to fit through standard door openings. The training system includes a complete curriculum, an extensive set of measuring instruments, and all the security and safety devices required to protect the user and the equipment. The Geothermal Training System, Model 46126-A, is variant of the Geothermal Training System, Model 46126-0. It contains exactly the same equipment with the addition of second geothermal heat pump with its control panel. The second heat pump is used to control the temperature of the water in the tank to simulate various ground conditions. it fits in the same mobile workstation as the rest of the equipment. The Geothermal Training System consists of two geothermal heat pumps, a ground-loop heat exchanger, a pumping station, a domestic hot water system, a circulation pump, control panels, and the instrumentation required to measure the operating parameters of the system. All components are mounted in a mobile workstation that is sized to fit through standard door openings. 2 Festo Didactic

Geothermal Heat Pump The geothermal heat pump is a commercial-grade heat pump that mirrors actual equipment installed in residential buildings. It allows flow, temperature, and pressure measurements at various important locations. It is possible to safely look inside the heat pump cabinet through clear plastic panels while the system is running. Parts of the cabinet of the geothermal heat pump are made from clear plastic panels, enabling users to safely observe the electronic control board and the mechanical components such as the heat exchanger, compressor, thermostatic expansion valve and blower while the system is in operation. The system also features a standard pullout disconnect switch used in HVAC equipment. The above photo shows the pullout disconnect switch, thermocouple terminal blocks, and pressure gauges. Pullout disconnect switch, thermocouple terminal blocks, and pressure gauges. Festo Didactic 3

Ground-Loop Heat Exchanger The ground-loop heat exchanger mainly consists of two short loops and one long loop (copper coils) immersed in a water tank. Each loop includes a flow meter, flow control valves, and temperature test points at each end. Temperature values can be read via thermocouple terminal blocks. The inlet and outlet headers include transparent sections to observe fluid flow. A pressure meter with a threeway valve is also provided to measure the pressure at the inlet and outlet of the ground-loop header. The ability to change the configuration of the ground loop, to control the flow of water in each loop, and the addition Ground loop header of a second geothermal heat pump enables students to observe the impact of various ground-loop conditions on the HVAC system performance. Domestic Hot Water System Partial view of the domestic hot water system. 4 The domestic hot water system consists of a hot water tank, a desuperheater heat exchanger and a pump. The domestic hot water system is provided with a flowmeter and thermocouples to measure the parameters required to calculate the amount of energy that is being transferred to the domestic hot water tank. Parts of the desuperheater heat exchanger and pump section are made from clear plastic panels, enabling users to safely observe the processes. Festo Didactic

Control Panels Geothermal Heat Pump control panel (both models) and Simulated Ground Heat Pump control panel (46126-A only). indicator lights. The operation of the geothermal heat pump and circulation pump is controlled via the geothermal heat pump control panel. This control panel features a main power switch, thermostat, indicator lights, and fault switches. Electrical faults can be inserted for troubleshooting purposes using switches hidden behind a cover. The operation of the second heat pump is controlled via the simulatedground heat pump control panel. This control panel contains a main power switch, a temperature controller, and The above photo shows the geothermal heat pump control panel (available in models 46126-0 and -A), as well as the simulated-ground heat pump control panel (available only in Model 46120-A). Pumping Station The pumping station mainly consists of a priming tank and a circulation pump. The priming tank supplies the circulation pump with water during startup, and prevents cavitation. The priming tank also allows variations in water level to compensate for pressure changes in the loop and can be bypassed to create a pressurizedloop configuration. This configuration also features an expansion tank typical for such a loop. The pumping station contains the connections to fill and flush the loops. A strainer is inserted in the network to remove impurities. Priming tank and circulation pump Festo Didactic 5

Troubleshooting The Geothermal Training System contains six instructor-insertable fault switches to enable users to develop troubleshooting skills. Connections to the control board are provided to allow users to diagnose the faults. The instructor may also insert many mechanical faults that modify the operation of the system, such as choking a flow control valve, obstructing an air opening, etc. Connections to the control board are provided for troubleshooting purposes. Courseware The training system includes a full courseware that consists of a student manual and an instructor guide. The student manual contains a series of job sheets. Each job sheet includes an information sheet that presents the theory and a manipulation section that lists a series of tasks for students to perform. The student manual is fully illustrated and color printed. Refer to the Table of Contents of the Manual(s) section of this datasheet to see the list of covered topics. The instructor guide provides results and measurements obtained under typical operating conditions, as well as the answers to all questions. No prerequisite are needed to attain the learning objectives of the courseware, since all the theory required is included in the information sheets. However, while not essential, it is recommended to have a basic knowledge in refrigeration, this is not essential. Topic Coverage 6 Geothermal Energy The Ground Loop Heat Pump Connections and Interior Piping Heat Pump Control and Safety The Refrigeration Cycle Psychrometrics Geothermal Heat Pumps Heat Exchangers Heat Pump Control and Safety Devices System Characterization Maintenance and Troubleshooting Geothermal Software Design Tools Estimated program duration: 25 hours Festo Didactic

Features & Benefits Includes a complete curriculum Integrates six instructor-insertable electrical faults to develop troubleshooting skills Contains a set of measuring instruments Includes all the security and safety devices required to protect the user and the equipment All components are commercial-grade components found in the industry Allows ground temperature control Three ground-loop heat exchangers of two different dimensions Pump and priming tank Test points to control the temperature in the water tank for continuous testing, and further testing using various conditions of ground temperature Energy recovery system Header allowing flow adjustment Ability to measure the temperature List of Manuals Manual Description number Geothermal Heat Pump Systems (Job Sheets - Student) 580637 (89952-20) Geothermal Heat Pump Systems (Job Sheets - Instructor) 580638 (89952-30) Table of Contents of the Manual(s) Geothermal Heat Pump Systems (Job Sheets - Student) (580637 (89952-20)) 1 Geothermal Energy 2 The Ground Loop 3 Heat Pump Connections and Interior Piping 4 The Refrigeration Cycle 5 Psychrometrics 6 Geothermal Heat Pumps 7 Heat Exchangers 8 Heat Pump Control and Safety Devices 9 System Characterization 10 Maintenance and Troubleshooting 11 Geothermal Software Design Tools Specifications Parameter Geothermal Heat Pump Capacity - Cooling Capacity - Heating Refrigerant Water-to-Refrigerant Heat Exchanger Type Geothermal Heat Pump (for the Simulated Ground) Capacity - Cooling Capacity - Heating Refrigerant Water-to-Refrigerant Heat Exchanger Type Ground-Loop Heat Exchanger Loops Value 4.3 kw (14 600 BTU/h) 3.1 kw (10 600 BTU/h) R-410A, nominal charge of 0.54 kg (19 oz) Tube-in-tube coil (coaxial) 6.4 kw (21 800 BTU/h) 3.7 kw (12 900 BTU/h) R-410A, nominal charge of 0.81 kg (29 oz) Tube-in-tube coil (coaxial) 2 short loops, 1 long loop Festo Didactic 7

Parameter Water Tank Capacity Expansion Tank Water Additives Pumping Station Priming Tank Pump Type Domestic Hot Water System Tank Capacity Circulation Pump Type Desuperheater Heat Exchanger Type Control Panel Heat Pump Thermostat Indicator Lights Fault Insertion Other component Safety Devices Instrumentation High-Pressure Gauge Low-Pressure Gauge Value 140 L (37 gal) 2.8 L (0.75 gal) Rust-inhibitor solution and antibacterial solution Insulated with level sight glass and two three-way valves Centrifugal 7.5 L (2 gal) Centrifugal Tube-in-tube coil (coaxial) Cooling/heating, non-programmable Loop pump, reversing valve, compressor, desuperheater, heat pump fault, circulation pump Six faults that can be inserted using switches Main power switch High pressure control, frost sensor, relief valve, fuse, breaker, pullout disconnect switch, tag and padlock 0 kpa to 5500 kpa (0 psi to 800 psi), refrigerant monitoring -200 kpa to 0 kpa / 0 kpa to 3450 kpa (-30 psi to 0 psi / 0 psi to 500 psi), refrigerant monitoring Flowmeters 20 L/min (5 gal/min), quantity 3; 7 L/min (2 gal/min), quantity: 1 Thermocouples Type K, quantity: 18, located at pertinent points and accessible through terminal blocks Pressure Gauge 0 kpa to 690 kpa (0 psi to 100 psi), heat exchanger monitoring, quantity: 2 Anemometer AC/DC Clamp-on Meter Control Panel (for the Simulated Ground) Indicator Lights Other components Power requirement Voltage - Phase - Frequency Current Required Physical Characteristics Intended Location Dimensions (H x W x D) Net Weight Waterproof pocket size with air velocity, temperature, relative humidity, dew point, and wind chill Dual type K thermocouple inputs, true rms measurements for ac voltage and current measurements, built-in noncontact voltage detector, resistance, capacitance, and frequency measurements Reversing valve, heat pump fault Main power switch, temperature controller 208/230 V - Single-phase - 60 Hz Two 15.0 A circuits On the floor (stands on casters) 1905 x 2273 x 740 mm (75.0 x 89.5 x 29.1 in) TBE 8 Festo Didactic

Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification. Festo Didactic reserves the right to make product improvements at any time and without notice and is not responsible for typographical errors. Festo Didactic recognizes all product names used herein as trademarks or registered trademarks of their respective holders. Festo Didactic Inc. 2019. All rights reserved. Festo Didactic SE Rechbergstrasse 3 73770 Denkendorf Germany P. +49(0)711/3467-0 F. +49(0)711/347-54-88500 Festo Didactic Inc. 607 Industrial Way West Eatontown, NJ 07724 United States P. +1-732-938-2000 F. +1-732-774-8573 Festo Didactic Ltée/Ltd 675 rue du Carbone Québec QC G2N 2K7 Canada P. +1-418-849-1000 F. +1-418-849-1666 www.labvolt.com www.festo-didactic.com Festo Didactic 9