INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Similar documents
HYC-950L. Medical refrigerator M.R.C LTD. OFFICES: HAGAVISH 3, HOLON P.O.B. 111, HOLON 58100, ISRAEL TEL: FAX:

Medical Refrigerator

Instruction Manual Refrigerator-freezer

Refrigerator - Freezer

Instruction Manual. Chest Freezer Model: CF.142L

Medical Refrigerator DW-25H SERIES

Refrigerator User s Manual MODEL:FC420MS

COMPACT REFRIGERATOR DRY ERASE SINGLEDOOR. User manual KSTRC24CBP KSTRC24CBU MODEL:

Instruction Manual. Refrigerator. Model: HS-65L

Hisense Refrigerator

WHS-65LB1/WHS-65LW1/WHS-65LSS1

User Instruction &)+ 4: CFH110QB

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

EVAKOOL ELITE - UPRIGHT FRIDGE FREEZERS OPERATING MANUAL

TM585. Refrigerator - Freezer Operation manual. Contents

User Manual. Chest Freezer ZFC26500WA

Thank you for buying this refrigerator-freezer. To ensure that you get the best

CONTENTS. Names of the parts...1. Safety warnings...2. Installation instructions...3. Operation instructions...3. Packing and moving...

WHD-125FW1 //WHD-125FB1/WHD-125FSS1

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Bar Fridge USER MANUAL MB46W

Thank you for purchasing our products and placing your confidence in us.

CHEST FREEZER Model Number: EWCF5W

CHEST FREEZER USER GUIDE LEC CF61LW

Refrigerator Freezer HD-368RWEW

Contents. Important Safety Instruction

ULTRA LOW TEMPERATURE FREEZER. User Manual

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Model:WHS-109FB1/WHS-109FW1/WHS-109FSS1

GLASS DOOR BAR FRIDGE

BEFORE USING THE APPLIANCE

REFRIGERATOR - FREEZER OPERATION MANUAL

Instruction Manual 1.1 CU. FT. Upright Freezer UF-114W (WHITE) UF-114SS (STAINLESS STEEL)

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

PICEM75 Ice Maker & Dispenser

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

FR-1020ARW FR-1020ARS

TWLRZ-238 REFRIGERATOR

V 120 SG - V 160 SG. Instructions for use

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

PORTABLE ICE MAKER. Model: IM-124S INSTRUCTION MANUAL

CHEST FREEZER HS225523

SJ-244V SJ-308V SJ-339V

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

HR6BF170R HR6BF170B HR6BF170G

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

# FREEZER ZF130 BK series #

OPERATION MANUAL. 20ltr Black - DS31837 (BCH-20B) 24ltr Black - DS28917 (BCH-24B) 24ltr White - DS31838 (BCH-24W) 32ltr Black - DS28918 (BCH-32B)

Chest Freezer HSA46330

This product contains flammable refrigerant isobutane (R600a). It is hazardous for anyone other than an Authorised Service Person to service this

Vinobox C 50 1T Vinobox C 50 2T

WINE COOLER. Model: WR 64-16

BAR FRIDGE 118 & 228 LITRE

SJ-22G SJ-25G SJ-29G. Refrigerator - Freezer Operation manual. Contents. Refrigerant: R600a Insulation blowing gas: Cyclopentane ENGLISH

User manual: Stainless steel CSS1 Refrigerator and FSS2 Freezer

INSTRUCTION MANUAL Water Dispenser

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Refrigerator INSTRUCTION MANUAL W1BF17 & W1WF17

HR6BMFF320 HR6BMFF320S

REFRIGERATOR. User manual KSTRC43BB KSTRC43BW MODEL:

Commercial Countertop Beverage Center

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

Dehumidifier. User Manual

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

FR270W FR270SS REFRIGERATOR

FRZ111W FRZ111S FREEZER INSTRUCTION MANUAL. Model No:

Wine Cooler CVD121V/CVD131V/CVD130/CVD120

Installation & Operations Manual for. MSC-A & MSF-A Model. Display Freezers. 5/16 Rev. A

Instruction Manual. No frost. Model. HITACHI Refrigerator. Contents. Page

Hazards or unsafe practices that may result in severe personal injury or death.

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

WARNING/SAFETY PRECAUTIONS

FR120RC/FR120RM FR120RR/FR120RB FN-153/FN-153C

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

F 100. Instructions for Use. Freezer

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

RCB53724MW RCB53724MX RCB53724VW RCB53724VX. User Manual Fridge Freezer USER MANUAL

Freestanding Wine Cooler Instruction Manual

BAR FRIDGE MODEL:FF.69L

Parts introduction FRONT BACK

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

Haier Medical and Laboratory Co., Ltd.

-86 Ultra Low Temperature Freezer

10/2017. Mod: WR-FP600-X. Production code: AGBS-600RI /

200L Chest Freezer / GVATCS20Q. Instruction Manual

FR-031DDRVBE1 FR-031DDRVWE

SJ-XE624F SJ-XE676F. Refrigerator - Freezer Operation manual. Contents MODEL

REFRIGERAT A OR USE DF1-15 F ridge

Contents. For your safety About your product Installing your appliance Using your appliance Care & cleaning...

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Installation/Instruction Manual

CI2 330 NF. EN-Instruction Manual DE-Bedienungsanleitung FR-Notice d Utilisation ES-Manual de instrucciones

Transcription:

INSTRUCTION MANUAL Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 Fax: 02 9560 6131 www.labec.com.au 2014

DW-HW50 Ultra Low Temperature Freezer Operation Manual LABORATORY EQUIPMENT PY LTD 26-30 Farr Street Marrickville NSW 2204 Tel:02-95602811

For your personal safety and better performance of this unit, please read this Operation Manual thoroughly and save it properly for future reference. Failure to read, understand and follow the instructions in this manual may result in damage to the unit, injury to operating personnel and poor equipment performance. The material in this manual is for information purposes only. The contents and the product it describes are subject to change without notice. LABEC makes no representations or warranties with respect to this manual. Safety Notice Power supply:this freezer is designed operating under 220~240VAC 50Hz power supply. Must provide one single exclusive plug receptacle with credible grounding to unit. Don t lengthen the line randomly. If you need to use 2.5 mm 2 copper line,you should keep 4 mm 2 line to connect the electrical outlet. Flammable and explosive materials, as well as high corrosive acid and alkali must be strictly prohibited in cabinet. Keep the key properly avoiding the children take it to open the back door which may result in unexpected injury. Don t make the power line pack and pressed by furnish or heavy goods.also please don t close to the compressor and heat source. Should wear safe glove to deposit goods, Prevent frostbite. If the power shut off,please wait 5minutes.Can to connect again, to prevent the compressor damage. Ultra Low temperature Freezer through condenser to reach refrigeration. To ensure the freezer run regularly, The body back and both sides away from the wall at least 30cm.,and not be blocked by barrier. Always use the proper protective equipment PPE (clothing, gloves, goggles etc.),avoid INJURY from low temperatures. Always follow good hygiene practices. Each individual is responsible for his or her own safety. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless

they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. WARNING Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction WARNING Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer WARNING Do not damage the refrigerant circuit WARNING Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer Young children should be supervised to ensure that they do not play with the appliance. The appliance must be positioned so that the plug is accessible. Please accord to local regulations regarding disposal of the appliance for its nonflammable refrigerant and blowing gas. Before you scrap the appliance, please take off the doors to prevent children trapped.

1.Schematic Picture and Description Door body Body Control panel Because the freezer amelioration and the model different. The actual product may not be the same as the photo, Please follow the actual freezer. Series of Ultra-low temperature freezer is designed to store materials under very low temperature condition for hospital, epidemic station, blood bank, research institute, university, biological pharmaceutical industry and gene engineering, etc. The internal temperature in cabinet can be easily adjusted through the keys in control panel. All operations are convenient and reliable.

2.Pre-Installation How to transport:pick up the unit from the bottom of tank and a slant plane within 45 is acceptable. All transportation should be carefully. Remove all wrappers. Check accessories and documents according to package list. Clean the unit thoroughly before any operation. Installing location:do not position the unit in direct sunlight or near heating diffusers, radiators, or other sources of heat. The ambient temperature should not exceed 32ºC. A minimum 20cm space on the sides, rear and top should be provided for better air circulation and heat discharge. Location where is too cold and place with high humidity or can be easily splashed by water are forbidden. On the flat floor, Can directly impulse the freezer moving at stone's throw. Notice:When moving the freezer, Please notice the wheel not to damage the line. Notice:Should take away the packing base before run the freezer. Notice:When connect the power supply,don t put the goods in the freezer immediately.please waiting for 12 hours The freezer working condition: A. The environment temperature:10ºc~30ºc B. The relative humidity: 80% C. No strong shake and causticity gas around. D. No sunshine and other cold/hot power effect. Ultra Low temperature Freezer working rule:running intermission P3:N and E port can t connect l 1 Safety Introduction Power supply:this ULT freezer is designed operating under 220V/50HZ AC power

supply. The unit can normally start under the voltage varying from 198V to 242V. 2 3 Must provide one single exclusive plug receptacle with credible grounding to unit. Inflammable and explosive materials, as well as high corrosive acid and alkali must be strictly prohibited in cabinet. 4 Keep the key properly avoiding the children take it to open the back door which may result in unexpected injury. 5 To avoid cold injury, please place and remove goods with protective gloves.

3 Operation Direction 3.1 Use at the first time Advise to use the warm water and little scour to clean the freezer,and use the water to clean,then dry it. To adjust the freezer at 40ºC,To cnnect the power,the compressor startup after 3minutes.30minutes later,the freezer temperature drop obviously,it mean the refrigeration system is normal.we advise to adjust the temperature at -35ºC at first,after stop the machine,then set as -40ºC To put the goods in the freezer after the temperature drop. To save the power,please don t often open and close the door 3.2 Adjust the temperature Keyboard functions: 1 Press "SET" 3seconds,will display as F01 ; 2 Use and to consult (F01 F02 F03); 3 Press "SET" to enter figures 4 Use and to add or reduce the figures. 5 press 'RST" to keep the change figures and back out. Times Figures range Windows default Introduction F01-86~ -10-80ºC Temperature setting point F02 1ºC~20ºC 1ºC Compressor temperature Boot back to poor(it mean inside freezer temperature >F01+F02 will start cooling. ) F03 1ºC~20ºC 1ºC Compressor temperature Down to poor(it mean inside freezer temperature <F01+F03 will end cooling. )

Notice: Except F01 can be set normally by customers,others please not change randomly, will damage the control system. How to display the setting figure: Press set 2seconds,Will show F01, press again will show the current temperature. Use and to add or reduce the figures. Finally press "RST" to confirm the set temperature. And back out. 1.High temperature alarm: when freezer inside temperature set temperature +10 will show HI" and sound alarm. 2.Low temperature alarm: when freezer inside temperature set temperature -10 will show LOW" and sound alarm. 3. Sensor failure: will show EE and alarm. 4. System pressure abnormal alarm:will show PS and alarm 4 First use please set temperature on -80C, wait the freezer normal working 3-4hours, then can set temperature below -80C If input the other parameter not carefully,please don t change randomly. (not use set key ),One minute to show the normal working state.also you can to connect the power again Please don t input the good in the freezer when connect with power, should wait freezer running after 12 hours. Input the goods not more than 1/3 each time, wait the freezer running after 24hours. Then input another 1/3 goods inside/ When freezer is cooling, don t open the door, or else will cause the freezer temperature up. Because of cooling inertia, the display temperature will be different with setting temperature (especially when temperature set higher), which is normal.

4 Defrost Unused Maintenance 1 There will be some frost on the surfaces of chamber for a long time running which may decrease the performance of freezer. If the thickness of frost is more than 10mm, some defrost operations are recommended. 2 Disconnect the power supply before defrosting. Wear special protective gloves for any interior operation! Open the door and remove all materials from freezer. There are two ways to defrost: (I) softly spud the frost on the surfaces with defrost shovel; (II) let the internal temperature rise naturally to thaw all frost accretion. Then clean up the water thoroughly with dry rag. 3 Connect the power supply after defrost is completed to run your freezer. 4 Note:Any electric heater, metal tool or edge tool CAN NOT be used during defrost operation. 5 Leave Unused:If the unit is not used for long time, please disconnect power supply and maintain as the following procedures. For next time operation, ensure there is no any water around the liners to avoid the seal of door is frozen. 6 Clean: Regularly clean the filter for better performance of freezer. (Procedure: Loose the two bolts in the ventilating panel and lay the panel flatly. Then loose the sit bolts in the filter and remove the dust with soft brush or wash it. Dry the filter before installing again. 7 Maintenance:The freezer should be cleaned regularly. For personal safety, please cut the power supply for any maintenance! Wear special protective gloves and glasses and wipe the inward and outward walls with wet and soft rag. 8 Note:DO NOT sprinkle water on the faces of cabinets, which may decrease insulating property of electric parts and rust metal parts. DO NOT use hot water, corrosive cleanser and organic solvent! Note:Prohibit minors or impaired persons using the freezer.

5. After Sales Service Some unexpected failures may arise during running. Please pay attention to the running status of your ULT freezer. If any exceptional case arises, please check and solve it according to the following introductions. If the problem is not solved well, please contact our service center for details. Problem Possible Cause ULT freezer does not operate Compressor does not work Temperature is higher than setting Too great noise l l l l l l l l l l l l Power outage has occurred. The plug is bad or not securely plugged-in. Fuse is blown. Voltage is too low or too high. Power in control panel is off. Temperature setting is wrong. Frost in inner wall is too thick The door is not closed properly or is opened too frequently. Overfull materials are put into chamber. Ambient temperature is too high. Freezer is not leveled well. Freezer leans upon the wall. ³ Below are normal operation conditions: There are some light clashes when the compressor starts up and stops. During wet season some frost may accumulate on the surfaces of cabinets. Please clean it with dry rag. DO NOT open the door twice within 5 miniatures. This may lead the hot air into the interior of freezer and the door may be difficult to open because of a negative pressure due to a sharp decrease of temperature of this part air. If the freezer has liquid flowing sound, the reason is the refrigerant flowing in the pipeline. Notice: Before call the service engineer, Please clean and disinfect the freezer. Condition: Cannot shake heavily, strike, preventing drenching. Environment Temperature: -40ºc~+55ºc, Relative humidity: 10%~90%.

6 The main functions The mainly technical parameter Model DW-HW50 The facility safe types I Kind B Type Climatic type N Input powerw 300 Storing temperature -10-86ºC Refrigeration Mixture/240g Valid capacityl 50 Sizedepthwidth height mm 600x560x910 Rating voltagev 220 Rating frequencyhz 50 6.2 The encasement list Item Operation Defrost Key Manual shovel Qty 1 2 1 6.3 The circuit diagram All technical parameters and circuit diagrams are on the unit proper.