Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Similar documents
Control/Communicator

2000 Series. Program Entry Guide. Control Panels

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Release Notes for Version 7.05 January 2007

OJD ITB No Attachment E Duress Alarm Equipment Specifications

DS7400Xi Addressable Control/ Communicator

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

CC408. Quick Reference Guide Solution 880

DOOR MONITORING/DURESS SYSTEM

D1255RB/D1256RB/D1257RB

Radionics D4112 Program Sheet

First Alert 1200C Installer Notes M. Leuck

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

GV2 Series Control Panels

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Solution-8248 Installation Manual ISSUE 1.16

Control/Communicator Installation Manual

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Installation Guide. Control/Communicator

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Security System. User Guide for the LED Command Center

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Security System. User s Guide for the Text Command Center

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

SECTION INTRUSION DETECTION 1.1 SECTION INCLUDES

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

TrueAlarm Fire Alarm Systems

SENTROL ZX400/ZX410. Security System Control. Programming

D2412 Control / Communicator Installation Manual

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Property of Monitronics Inc

D720 and D1255 Command Centers

CC488. Quick Reference Guide Solution Ultima 880

Quick Programmer s Manual

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Contact ID as of 2/2/2015

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

AXI LED USER MANUAL (REV. 1.0)

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

NetworX NX-8V2. LED Keypad User Manual

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

GEM-P800. Control Panel/Communicator. Installation Instructions

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

SECURITY SYSTEM NOTES

TABLE OF CONTENTS TABLE OF CONTENTS 1

Safewatch Pro 3000 System Manual

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Fire Command Keypad. XR5 User s Guide

Programming Worksheets

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

EVO192 v3.0 Fire and Burglary What s New

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

SECTION INTRUSION DETECTION

RE6100 Series Helix Security and Automation Platform

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Series. NX-4-EUR Control Panel. Installation manual

D1265. User's Guide. Touchscreen Keypad

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

D7212 Control/Communicator Operation and Installation Manual

Spectron LSN (Life Safety Network) Suggested Specifications

ELECTRONICS LINE S TECHNICAL SUPPORT DEPARTMENT: (972)

User's Manual VISTA-40 N7003V1 6/97

Installation Instructions

NETWORX TM. User manual NX-4

NetworX Series NX-4V2 Control Panel Installation and Startup

CARD ACCESS CONTROL SYSTEM

Addressable Fire Alarm Control Panel

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

L900 series USER MANUAL

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Integrated Security Solutions

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

All-In-One Wireless Security System V1.0. Model #: MG-6060

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

System Introduction. 1.1 Specifications

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Version 1.03 January-2002 USER S MANUAL

Reference Guide for the DS7400Xi (Version 3+) Control/Communicator

Addressable NAC Output Module D327A

Tomorrow s technology for today s security needs.

Transcription:

Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance... 2 1.2.3 Warranty... 2 2.0 PRODUCTS... 3 2.1 SYSTEM DESCRIPTION... 3 2.2 SYSTEM FEATURE/CAPABILITY SUMMARY... 3 2.3 SYSTEM INTERFACE REQUIREMENTS... 6 3.0 EXECUTION... 7 3.1 PROGRAMMING... 7

GENERAL 1.0 GENERAL 1.1 SCOPE OF WORK 1.1.1 Introduction The system shall be the standard product of one manufacturer, and the manufacturer shall have been in business manufacturing similar products for at least 5 years. 1.2 GENERAL CONDITIONS 1.2.1 After-Sales Support The Contractor shall be a factory-authorized and trained dealer of the system and shall be factory-trained and certified to maintain/repair the system after system acceptance. 1.2.2 Quality assurance All equipment, systems, and materials furnished and installed shall be installed in accordance with the applicable standards of: 1. National codes: NEC, NFPA, UBC 2. Approvals and listings: UL 3. Local Authorities Having Jurisdiction 1.2.3 Warranty All components, parts, and assemblies supplied by the Manufacturer and installed by the Contractor shall be warranted against defects in material and workmanship for a period of at least 36 months (parts and labor), commencing upon date of acceptance by Owner. Warranty service shall be provided by a qualified factorytrained service representative. A&E Specifications 45148D Page 2 2003 Bosch Security Systems

2.0 PRODUCTS 2.1 SYSTEM DESCRIPTION PRODUCTS The Digital Alarm Communicator System (DACS) specified herein shall include a Digital Alarm Communicator Transmitter (DACT), test timer, battery charging / voltage supervision circuitry, powered two-wire smoke detector compatibility, diagnostics displays, lightning / EMI protection circuits, and the associated optional modules and components for a complete DACS system. The DACT firmware shall support programmable "software" features as detailed in section 2.2 System Features/Capability Summary. The following describes the general functional requirements of the DACS system: A. The DACS shall support the connection and reporting of intrusion and residential fire detection devices. B. The DACS shall provide identification, annunciation, and communication of alarmed detectors by point. C. The DACS shall be "modularly" expandable using hard-wired modules, wireless receivers or via input points connected to a keypad. Wireless input points shall be programmed via a learn mode and not be addressed via mechanical means. D. The DACS shall have electrically-supervised detection loops and power supplies (mains and battery(s)). This supervision shall be programmable for the purposes of reporting this information to the DACR. The battery supervision must include missing-battery supervision. The mains supervision reporting must be able to be suppressed until another signal is sent to the DACR (tag along reporting). E. The DACS shall be capable of reporting and communicating alarm or trouble event data by reporting to one (1) or two (2) off-site remote Digital Alarm Communicator Receivers (DACR) via dial-up analog telephone lines. Pulse or Dual-Tone Multi-Frequency (DTMF) dialing option is required. F. The DACS shall be capable of sending (manually or automatically) test and status reports to remote DACRs. Automatic tests shall be capable of being sent daily, weekly or once each 28 days. Automatic test times shall be capable of being set as an offset of up to 24 hours from the current time. Automatic test reports shall be capable of being deferred by one test interval if any other report is transmitted in the current interval. G. The DACS shall be programmable locally or remotely. Programming shall be accomplished via a portable programmer or a computer with a remote programmer and diagnostic software package. An on-site user must be able to initiate remote programming while on-line with the servicing location. The remote programming device must provide a compare feature and allow for downloading either the stored program or the (un)modified program copied from the panel. The number of system programmers shall be severely restricted via the use of program locking features and passwords. Passcode protection in excess of 16 million combinations is required. The panel must allow the local programming option to be disabled and must provide a method to program a panel, while no one is home, when the panel shares a line with an answering machine. H. The DACS shall annunciate alarm, trouble, service reminders, and other relevant system status messages in English text at the keypad. Point description text is to be 16 custom characters per point. I. The DACS shall be capable of executing diagnostics and testing functions locally or remotely. J. The DACS shall be capable of activating 2 relays for auxiliary functions. Each relay output shall be capable of operating as an AND or an OR for two of the functions. 2.2 SYSTEM FEATURE/CAPABILITY SUMMARY The following indicates system software/hardware capabilities, capacities, and formats: A. Number of Loops/Sensors: 24 separately-identifiable points, of which 8 are on-board loops and up to 24 are off-board addressable points / zones connected to 8 point hardwire interface modules, 8 point RF interface, 16 point RF interface or 4 input point keypads. A&E Specifications 2003 Bosch Security Systems Page 3 45148D

PRODUCTS B. Programming Point Functionality: Each point in the system shall provide for the following matrix of selectable type of response in the system. Type Response Options 1. Disabled 1. No Alarm Response 1. No Point Options 2. Fire 2. Reports 2. Trouble on Open 3. Fire Alarm with Verification 3. Alarm Report Delay 3. Trouble on Short 4. Buzz on Fault 4. Swinger Bypass 4. Trouble on Open or Short 5. 24 Hour, Visible 5. Alarm Output 5. Double Knock 6. 24 Hour, Invisible 6. Cross Point 7. Controlled, ALL, Delay 7. Partner Point 8. Controlled, ALL, No Delay 9. Controlled, PART, Delay 10. Controlled, PART, No Delay 11. Keyswitch 12. Extended Delay, ALL 13. Extended Delay, PART C. Number of Keypads: Eight (8), each capable of displaying custom English text on liquid crystal displays and sounding different patterns of audible alarm for different events, shall be required. D. Number of User Passcodes: Up to 8 different passcodes shall be required. Passcodes shall be three (3) to six (6) digits. Passcodes shall be assigned one of three (3) different authority levels to carry out functions such as changing passcodes from the keypad, activating one-time passcodes and changing watch tone responses. These passcodes shall also be required for performing various system functions such as disarming the system, transmitting a duress code, and silencing sounders. E. Communication Formats: The Modem II format shall be utilized for optimum system performance. The DACT shall report to a Commercial Central Station using a Bosch Security Systems D6500 Alarm Receiver that supports the Modem II communication format. One such advantage is point identification information transmission to DACRs (Alarms, Troubles and Restorals by point). Others include actual point number; point text; actual user number; by-passed points; relay activation; and opening/closing reports by user. F. Testing, Diagnostic, and Programming Facilities: Automatic test reports and remote system access for diagnostics, and programming shall also be supported via a remote central station computer utilizing the RAM II software. G. Reports: Reports to DACRs at commercial central stations as a result of system supervision shall include alarm, trouble, missing modules, restoral, system status, AC failure and low battery. The DACS shall also transmit test reports once every 24 hours, 7 days, or 28 days. CPU failure shall be annunciated locally. H. "Phone Routing": The DACS shall have the capability of communicating with up to two (2) different DACRs (phone numbers), Each Phone Number can be up to 19 digits long. The DACS reports shall be classified into eleven (11) sub-categories or "report groups." Each DACR shall be designated as a primary or duplicate destination for each report group. The transmission of events, allows the reporting of different types of information to different remote DACRs. The report groups shall be as follows: 1. Fire Alarm 7. Cancel reports 2. Non-Fire Alarm 8. System trouble reports. 3. Point Trouble 9. System restoral reports 4. Restorals 10. Duress 5. Closing reports 11. Test 6. Opening reports I. Number of Programmable of Relay Output Modules: Two relays (Form C) are to be provided via individual or dual relay module for a total of two relays per DACS. These multi-purpose modules are programmable and shall be used to implement auxiliary functions (manually or automatically). The following functions can be executed: A&E Specifications 45148D Page 4 2003 Bosch Security Systems

PRODUCTS 1. Alarm (selected Points) 13. User Reset (3 key) 2. Alarm Memory (selected Points) 14. AC Failure 3. Point Trouble (selected Points) 15. Battery Trouble 4. Follow Point (selected Points) 16. Communication Fail. 5. Watch Tone (selected Points) 17. Communicating 6. A, B, C Key Steady (selected Points) 18. Ground Start. 7. A, B, C Key Pulsed (selected Points). 19. Entry and Exit Delay 8. A, B, C Key Momentary (selected Points) 20. Extended Delay 9. Off with passcode (10 seconds). 21. Pulsed Output 10. Follow Alarm Output 22. Two Second Output 11. All ON 23. RF Keypad Light Key 12. Part ON 24. RF Keypad Special Key J. Number and Alarm Output Selections: Two different types of alarm output selections shall be supported by the DACS: Steady, Pulsed. K. Miscellaneous Features: Programmable Swinger count (1, 2, 3 or 4), Momentary Keyswitch on/off operation, Interconnection to proximity door access system with 199 users providing automatic disarming on entry. L. DACS Power Ratings: The DACS shall provide 0.350 amps of auxiliary power and 1.5 amps of alarm power, both rated at 12VDC. Additional auxiliary power shall be provided by adding battery/charger modules up to a maximum of 2 amps. M. DACS Fault Detection: The DACS shall check the point sensor loops once every 500 milliseconds. The point response time is fixed at 2 scans (1,000 milliseconds). N. User-Programmable Features: The DACS shall provide a "user-friendly" interface for operating the system to the operational criteria of the application. A service passcode can be assigned to the servicing agent allowing him limited access to system functions. User-programmable / activated functions include: 1. Arming the system: All, All Instant, Part, Part Instant, watch mode, and arming the system with a duress passcode. 2. Disarming the system: All and disarming with a duress passcode. 3. Viewing system status: Faulted points, event memory, bypassed points, and point status. 4. Implementation functions: Bypass a point, unbypass a point, reset sensors, silence bell, activating relays, initiating the remote programming function locally to allow programming the system from a remote location. 5. Testing the system: Local Walk test, Service Walk test, send report to remote DACR to check the telephone link. 6. Change system parameters, passcodes, watch modes and watch points. 7. Transmitting special alerts and activating audible and visible signals. 8. Keypad will include electronic manual in the form of on-line text help displays. A&E Specifications 2003 Bosch Security Systems Page 5 45148D

PRODUCTS 2.3 SYSTEM INTERFACE REQUIREMENTS A. Grounding: The Contractor shall properly earth ground the DACS. B. Primary power: The Contractor shall provide a dedicated 120 VAC power circuit to the DACS system. This circuit shall be connected to the emergency power system. The 120 VAC is stepped down to 16.5 VAC to power the DACS panel using a class two, plug-in transformer. This power circuit shall be properly rated to continuously power all points and functions indefinitely in full alarm condition. C. Primary power supervision: When the primary power source fails, the system can be configured to report an "AC Fail" message to a commercial central station. The creation of this message is suppressed if the AC Failure is less than 60 seconds. The message can be programmed to "tag-along" with another message transmitted to the central station. The system will always display a loss of primary power on the keypad and may be configured to provide additional audible warning. D. Secondary power (standby battery): The Contractor shall provide adequate battery power as defined by the relevant application criteria, (UL 985 and 865 for alarm installations or NFPA 72 chapters for fire applications). Appropriate battery chargers shall be provided consistent with the battery backup capacity. E. Secondary power supervision: When the secondary power source experiences an 85% depletion of its standby capacity, the system can be configured to report a "Low Battery " message to a commercial central station. The system will always display a low battery condition on the keypad and may be configured to provide additional audible warning. F. Wiring: The contractor shall provide cables consistent with the manufacturer's recommendations. The following general guideline shall be followed for wiring installation: Wiring shall be appropriately color-coded with permanent wire markers. G. EMI / Lightning Protection: The DACS system shall be protected from EMI and lightning surges. H. Telephone interface: This interface shall conform with FCC rules part 15 and 68. I. Auxiliary function control interfaces: Auxiliary functions such as activating bells, strobes, or lights shall be accomplished using the optional relay modules. These auxiliary interfaces shall be electrically isolated to avoid inter-system interference or damages. J. Non-Volatile Backup: Functional criteria programmed into system memory shall be backed up non-volatile. Additionally, the number of system programmers shall be severely restricted via the use of program locking features and passwords. A&E Specifications 45148D Page 6 2003 Bosch Security Systems

3.0 EXECUTION 3.1 PROGRAMMING EXECUTION Programming of the system shall include the following tasks: A. Programming system configuration parameters (hardware and software, zone/circuit numbers, communication parameters). B. Programming operational parameters such as opening/closing reports, system response text (custom English) displays of events, activation of relays that drive auxiliary devices, and identifying types of zones/loops. C. Programming passcodes according to the authorities and functions defined by the owner. D. Other system programming tasks required by the owner. These additional programming requirements shall be coordinated between the owner and the contractor. END OF SPECIFICATIONS A&E Specifications 2003 Bosch Security Systems Page 7 45148D

2003 Bosch Security Systems 130 Perinton Parkway, Fairport, NY 14450-9199 USA Customer Service: (800) 289-0096; Technical Support: (888) 886-6189 45148D A&E Specifications 8/03 Page 8 of 8