Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Similar documents
K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Concise catalogue Water-Industry

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

CTT8 TEMPERATURE MONITOR DEVICE

MO n : 12JMC rév A

UDC 700 Universal Digital Controllers and Indicator Specifications

JENCO ELECTRONICS, LTD.

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

RS Pro Infrared Temperature Sensor

Dew point set DS 400

Dual Input ph/orp Analyzer

Intelligent addressable fire alarm control panel

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MultiFix Central unit

eed quality electronic design USER s MANUAL

F4 Process Controller Installation and Operation Guide

203RE ph v 1.0 Instructions

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

portable gas analyser

Dual Input Toroidal Analyzer

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

TPF Series Ozone Generators

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

PHOTOELECTRIC AMPLIFIER SERIES

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Dosing systems for dishwashing machines TWINDOSE SERIES

portable gas analyser

HSD Dry Cabinet

HSD Dry Cabinet. Outstanding performance

O3TH. Ozone Detector c/w Indicator for Temperature/Humidity. Automatikprodukter. Features. Technical Data. Description. Ordering Codes. Dec.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Dual Input ph/conductivity Analyzer

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Advanced FireAlarm Panel 1-4Loop

Flopurge TS. Operation Manual

Excellence through Versatility

OPTISENS TUR 2000 Technical Datasheet

TC515 and TC600 Installation Manual. a Winters company

Toxic Gas Detection. Model F12. Toxic Gas Detection

FEC400 Series. Installation Manual

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Measuring Recording Online Monitoring Regulation Alarming

Signet V(D) to V(D) PVDF Conductivity Electrodes

BC3250. Blowdown Controller

BSC-50 ADU-500. Autonomous RTUs

AS950 PORTABLE SAMPLERS

User Manual System 11

PULSAFEEDER MODEL 3210 MICROPROCESSOR-BASED CONDUCTIVITY CONTROLLER INSTALLATION & OPERATION MANUAL SERIAL #:

High Pressure Conductivity Monitor

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

SENSORS TRANSMITTERS. Process monitoring

EC3-X33 Stand-alone Superheat Controller Technical Data

D3000. Installation & Setup Guide

Installation Manual Tracker 221

Controller Specification Sheet

Flostop TS D7E and A8E. Operation Manual

Hydrazine Analyzer Series 2171 Specifications

Steam and Water Analysers

Universal controller for panel mounting Models CS6S, CS6H, CS6L

CLEANROOM MONITOR CR3A Network - Installation Instructions

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Two-Channel Gas Controller

COBRIX3 multibev. Online Beverage Analyzer. ::: Unique Density & Concentration Meters

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Installation Instructions & Operating Manual. Heat Exchanger PLEASE READ CAREFULLY BEFORE INSTALLING. Incorrect Installation Will Affect Your Warranty

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

IGD.CO.UK

Temperature Controllers

Odyssey. issue 01c. system manual

Omniguard 4: Features

HSD Dry Cabinet. Outstanding performance

User Manual Ichill 200 L/D (Firmware version 1.7)

Dissolved Oxygen Measurement liquisys M COM 223 / 253

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

WIO200 Water In Oil measuring instrument

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

MCS 4000 Control Panel

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

MultiFix Central unit

Advantages / Characteristics

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

PCA 310, PCA 320, PCA 330 Chlorine, ph, Temperature, ORP Analyzers

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

WATER TREATMENT SYSTEM CONDUCTIVITY CONTROLLER With feed verification INSTALLATION & OPERATION MANUAL

SiteSentinel itouch Console

WIO200 Water in oil sensor

Constant climate chambers

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Transcription:

Inductive Range Inductive 0 1.000 μs; 0 10.000 μs; 0 100.000 μs; 0 1 Simens (0 999,999mS) Resolution 1 μs; 10 μs; 100 μs; 1.000 μs S410/IND Electrodeless Conductivity Sensors Low Cost Low Maintenance Online, Dip and Tank Mounting Options Ideal for Cooling Tower Bleed, Rinse Water & Solution Concentration Applications The S410/IND Series of Electrodeless conductivity sensors have been developed and engineered to produce a very low cost sensor, without sacrificing performance or quality. This has been achieved by injection moulding the sensor in glass loaded polypropylene. The sensor provides all of the benefits that the method of Electrodeless conductivity measurement provides. It is extremely tolerant of coating on the sensor, probably the greatest problem with conventional conductivity measurement. The S410/IND incorporates temperature compensation and can be mounted online, in a tank wall or large bore pipe or in an open tank using a range of adapters. Features Sensor Only Operating temperature Wetted material Temperature compen. -5 to 60 C (not freezing) Glass filled polypropylene 2 wire Pt1000 Online Assembly Material Operating temperature Dip length PVC with Viton seal -5 to 60 C (not freezing) 600 or 1200 mm Cable Connection Protection Standard 5 metres 0.5" BSP male IP68 Mounting Operating pressure Standard bracket or flange option Vacuum to 6.5 bar (100 psi)

Chemitec introduces the 35 Series family of industrial control instruments designed for measuring: ph/orp Dissolved Oxygen Conductivity Turbidity Chlorine Chlorine Dioxide Ozone 1 analogue output Programmable for measure. Output limits are freely programmable between the range of measures. 4 digital outputs ON OFF Set Point: set of the operating range (hysteresis / direction) and of start/stop time 000 999 Seconds Alarm Reporting: Instrumental anomalies, minimum, maximum, set point s delay, permanence time (live check) Delay time: 00:00 59:99mm:ss at minimum steps of 15sec Permanence time: 00:00 99:99 hh:mm Set Point disableing (in case of alarm): Enable / Disable. Wall mounting version with IP66 protection (144 x 144 x 120 mm) Electrode washing Programming of the time leg (minimum 15min) and lasting. During the washing phase, all digital and analogue outputs are freezed. Digital input To disabile dosages. Panel mounting version (144 x 144 x 100 mm) RS485 Serial output For set-up and real-time data acquisition from remote. Manual controls Possibility to simulate all the analogue and digital outputs using the keyboard Temperature compensation Via Temperature sensor PT 100 with 3 o 4 wires, or PT 1000 Panel mounting version (96 x 96 x 133 mm)

Electrical connections Measure 1 8 Serial Port RS485 1st Channel Temperature 2 Vac/dc 3 Digital 4 CPU 9 Output 4 20 ma 1st Channel Power Supply 100 240 Vac 5 Ground 6 Relay 1 Setpoint Keypad 10 Relay 2 Setpoint Relay Alarm Relay Wash Output 1 Chemical Measurement 8 SRS485 Serial and USB Ports 2 Temperature measurement 9 Current outputs 3 voltage 15 30 Vac-Vdc 10 Dry contact relay 4 Digital SetPoint 1 SetPoint 2 5 Universal input 100 240 Vac Alarm 6 Earth Potential Probe washing Keypad and Display

Simple and user friendly set up. Main menu graphic icons Interactive and clear interface

Wall-mounting version IP66 144 122,5 25.5 32 80 144 Ø6.5 68 16.25 4 x pg9 38 38 18 30 2 x pg11 35 35 Panel-mounting version 144 x144 Panel-mounting version 96 x 96 92 92 88 96 108 123 Paab Tekno Trading AB - Tingvallastrand 12, 661 40 Säffle, Sweden Tel: +46 533 150 60 - Fax +46 533 169 31 - info@paab.com - www.paab.com