Flameless Technology Demonstration Heater

Similar documents
THE WORLD S FIRST FLAMELESS CRUDE HEATER

The World s First Flameless Crude Heater

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

LOW-NOX BURNER RETROFIT CHALLENGE

Fired Heaters Key to Efficient Operation of Refineries and Petrochemicals

Shell Martinez Refinery Callidus CUBL Burners

INDUSTRIAL WATERTUBE BOILERS

Coker Heaters Performance Improvement. Don Tran LyondellBasell, Houston Refinery & Ashutosh Garg Furnace Improvements Sugar Land, TX

Trends for Radiant Tube Heated Strip Lines

OIL AND GAS INDUSTRY

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Burners Flares Incinerators Vapor Combustion

PROPOSED October 15, 2013

DELTA-TE III. Nozzle-mix line burner

Amec Foster Wheeler- Fired Heater Division

Improving Fired Heaters Reliability using Inclined Firing Technology

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

Improving the Performance and Reliability of Fired Heaters and Boilers

Small Capacity Regenerative Burners

HYDROCARBONENGINEERING June June 2015

Process Heat Equipment & Combustion Field Services Guide

HOW TO BOOST THE PERFORMANCE OF FIRED HEATERS

Shale Oils Designing for Improved Crude Preheat Train Reliability and Performance

DATE PRODUCT WAS INTRODUCED TO THE CANADIAN MARKET: September 2018

Kolmetz Handbook of Process Equipment Design REFINERY FURNACE DESIGN, SIZING AND TROUBLESHOOTING (ENGINEERING DESIGN GUIDELINE

Pulse Firing Doubles Capacity and Cuts Fuel Costs

PUSHING THE LIMITS OF WHAT IS POSSIBLE

Get Wise to ThermWise. An Insider s Guide to ThermWise Rebates

Zeeco recently had the opportunity

Revamp Fired Heaters to Increase Capacity Use these guidelines to ensure a successful project

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

d. Portable water heaters used exclusively for underwater diving operations.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

"HC" AIRFLO. In-duct firing line burner

Burner Comparisons. Typical Competitor s Burner

Boiler MACT Webinar Q/A

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Specifications of V-Line burners

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

GAS CONDENSING TECHNOLOGY

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

San Joaquin Valley Unified Air Pollution Control District. Best Performance Standard (BPS) x.x.xx

PROFIRE -E SERIES BURNERS

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Boiler Basics. Design and operation

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Originators of the Flexible Water Tube design

ON-LOAD CLEANING FOR HEAT EXCHANGER FOULING. Optimising heat transfer on petrochemical plants and oil refineries

FUEL-FIRED VERTICAL TUBELESS BOILERS

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

High tube metal temperatures

Presented by Steve Connor August 26, Boiler Choices: The What, When & Why

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

The world s standard in efficiency. CBEX FIRETUBE

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

PETRO-CANADA OIL AND GAS. FIRE-TUBE IMMERSION HEATER OPTIMIZATION PROGRAM & Field Heater Audit Program

2007 KBC Advanced Technologies plc. All Rights Reserved.

PACKAGED COMMERCIAL WATERTUBE BOILERS

You can view our archived webinars by going to

Fired Heater Flooding

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

OPERATING AND MAINTENANCE MANUAL

HFID Heated Total Hydrocarbon Analyzer Module

Fuel-Fired Vertical Tubeless Boilers

Downsizing after Retrofit

High Performance Diesel Fueled Cabin Heater. Abstract

DIRECTIVE NO: D-B

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

TRANE 95 GAS FURNACES TRANE 95 GAS FURNACES THE WARM SIDE OF TRANE. Innovative furnaces with efficiency in mind READ ONLY

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

The Only Gas Furnaces Made in Canada napoleonheatingandcooling.com

Originators of the Flexible Water Tube design

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Solution builder. in energy management.

PROVIDING PROCESS EQUIPMENT SOLUTIONS TO CUSTOMERS FOR OVER 160 YEARS

INDITHERM. Low temperature gas burners

Zircomat Oxygen Analyzers

Steam Fundamentals. (in heating & processing applications)

Heating Systems Best Practices II Alternative Systems & Approaches for Low Heat Load Homes

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

HOT OIL Special edition s BONO News October 2005

The Only Gas Furnaces Made in Canada napoleonheatingandcooling.com

MULTIPLEX SELF RECUPERATIVE gas burner

Sludge Dryer Wet Scrubber Used to Produce Renewable Energy

INDUSTRIAL BOILER MACT GUIDELINES

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

FAMILY PRO SIMPLY THE BEST

New generation heat exchanger improves industrial energy efficiency

Heating Systems Best Practices II Alternative Systems & Approaches for Low Heat Load Homes

Solutions to Pollution

Tjernlund Side Wall Venting Products

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Transcription:

Environmental Conference Poster Session October 14-16, 2012 Denver Marriott City Center Denver, Colorado Flameless Technology Demonstration Heater Presented By: Taras Lewus Sage Environmental Consulting, LP John D. Ditmore, Manager Environmental CVR Energy, Inc. William C. Gibson, President Great Southern Flameless, LLC American Fuel & Petrochemical Manufacturers 1667 K Street Suite 700 Washington, DC 20006 202.457.0480 voice 202.457.0486 fax www.afpm.org

This paper has been reproduced for the author or authors as a courtesy by the American Fuel & Petrochemical Manufacturers (AFPM). Publication of this paper does not signify that the contents necessarily reflect the opinions of the AFPM, its officers, directors, members, or staff. Requests for authorization to quote or use the contents should be addressed directly to the author(s)

FLAMELESS TECHNOLOGY DEMONSTRATION HEATER Authors: John D. Ditmore Manager, Environmental CVR Energy, Inc. William C. Gibson President, Great Southern Flameless, LLC Taras Lewus Sage Environmental Consulting, L.P. ABSTRACT In one of the most recent refinery consent decree (CD) settlements, Coffeyville Resources Refining and Marketing, LLC (CRRM) will be required to conduct a demonstration of Flameless Heater Technology. Under the CD, the Flameless Technology Demonstration Heater must have a rated capacity of at least 9.5 MMBtu/hr and be capable of operating in the 100% Flameless Firing mode, combined flameless and Conventional Mode, and 100% Conventional Mode. Additionally, the Flameless Technology Demonstration Heater must be capable of NOx emissions of < 0.01 lbs/mmbtu (HHV) per hour at 3% O2 (dry) when operating in Flameless Firing mode (without SCR) and available to operate 95% of the time while being 90% efficient on a lower heating value basis ( LHV ) when operating in Flameless Firing mode. The focus of this paper will be to provide the background on flameless technology and outline the CD requirements associated with this flameless technology demonstration. This paper will also provide background and insight on the factors considered in the demonstration heater selection. FLAMELESS TECHNOLOGY Great Southern Flameless (GSF) has developed a flameless technology to be used for process heaters in the petroleum refining industry. While High Temperature Air Combustion (HTAC) and Flameless Combustion are not new concepts, they are both new to use in direct fired process heaters in the petroleum refining industry. Concerns regarding safety, operability, and reliability through the wide range of operations required for typical refining heater operations have caused owner/operators concern with implementing this technology. What is needed is a furnace that can be run both conventionally (Ultra-Low NOx) and in the flameless mode (3-8 ppmvd NOx). GSF s flameless heater design utilizes HTAC for maximum efficiency and CO 2 reduction yet the flameless combustion process produces NOx levels which have previously only been achievable with the use of Selective Catalytic Reduction (SCR) systems. The cost for GSF flameless systems is equivalent to a conventional double fired heater with a conventional balanced draft air preheat system. Flameless Technology Fundamentals For conventional combustion burners to be operable there is the rule of the three T s: Time, Temperature and Turbulence. The fuel and air molecules, along with a relatively low level of inert flue gas molecules in an Ultra-Low NOx burner apparatus, require close spacing, low velocity and turbulence for mixing in order to create a stable primary flame. The stabilized flame creates a localized high temperature flame core which generates significant levels of NOx as well as uneven radiant heat flux to the process coil. Uneven radiant heat flux combined with frequently seen flame impingement causes hot spots, coking, shortened run lengths, reduced throughput and even the possibility of tube rupture. The flameless combustion reaction also requires time and temperature. However, it is diffusion rather than turbulence which drives the oxidation reaction to completion. Therefore, flameless combustion uses open spacing and high velocity fuel and air which both entrain very high levels of inert flue gas. Page # 1

An even radiant heat flux to the process coil and the flue gas heat recovery to the combustion air stream provide increased heater efficiency that results in up to an 11% reduction of fired duty and thus an 11% reduction in emissions. This is the equivalent of greater than 90% efficiency on an LHV basis. By reducing stack flue gas temperatures as low as 240 o F in the air preheater, additional heat recovery and unit efficiency can be captured. With flameless combustion, the high pre-heated air temperature will not negatively impact NOx emissions. Because flameless combustion does not depend on a stable primary flame with an adiabatic flame temperature of 2400 o F or greater, NOx emission levels for a flameless heater are only 3-8 ppm even with HTAC and without an SCR. Refer to Table 1 for comparison details. Table 1. Heater Technology Comparison FLAMELESS MAXIMUM EFFICIENCY FLAMELESS BASELINE CONVENTIONAL NATURAL DRAFT Air Preheat Yes Yes No Combustion Air Temp, o F 890 890 60 Stack Temp, o F 240 300 650 Bridgewall Temp, o F 1537 1537 1537 Heat Release (LHV), MMBtu/hr 107.5 109.9 121.2 Heat Efficiency (LHV), % 93 91 82.5 Heat Efficiency (HHV), % 83 81 72.5 Energy Savings (LHV), MMBtu/hr 13.7 11.3 NA CO, ppmvd < 50 < 50 < 50 NOx, ppmvd corrected to 3% O2 3-8 3-8 20 NOx, lb/mmbtu (HHV) 0.006 0.006 0.024 NOx, lb/hr 0.723 0.741 3.31 NOx reduction, lb/hr 2.587 2.569 NA NOx reduction, % 78.2 77.6 NA CO2, lb/hr 13,867.5 14,177.1 15,634.8 CO2 reduction, lb/hr 1,767.3 1,457.7 NA CO2 reduction, % 11.3 9.3 NA Basis: Radiant Coil Configuration: Double Fired Absorbed Duty: 100 MMBtu/hr Fuel Composition: 30% H2, 50% CH4, 20% C3H8 15% Excess Air GSF s Advanced Flameless Technology The above fundamentals are well known and proven in the combustion science world and are undisputed, so why are refineries and chemical plant owners not quickly and anxiously converting every heater in the plant to a flameless heater? The answer of course is because of the wide ranging operating parameters that are required for most process heaters. Many heaters require a turndown firing rate of 5:1 or even greater. Many units have wide ranging fuel heating values that swing up and down without notice. Many units run minimum firing rate at Start of Run (SOR) and then are at maximum firing rates at End of Run (EOR). Some units run opposite with higher rates for SOR and ramp down toward EOR. The heater is often the only high Page # 2

temperature heat source for most process units and it must provide dependable heat 24 hours a day, 365 days a year. There now is a way to have all the efficiency and emissions benefits of flameless combustion along with the flexibility, safety, reliability and operability of a conventional heater. GSF has developed a conventional heater that can also be run in the flameless mode. By using HTAC generated from flue gas heat recovery together with GSF s patented refractory wall texture, localized diffusion zone temperatures are maintained above the auto-ignition temperature of the fuel so the flameless oxidation reaction is sustained even at the lower bulk flue gas temperatures commonly seen in refinery process heaters. By utilizing an HTAC air pre-heater, heater efficiencies of up to 93% on an LHV basis can be realized. This can equal a reduction in fuel firing and CO 2 emissions of 11% when compared to conventional heaters without an air pre-heat system. The General Arrangement drawing shown in Figure 1 is an example of a typical conventional heater with an air pre-heat system that can also be run in the flameless mode. Figures 2, 3 and 4 provide details of a typical coil arrangement. An additional technology advancement that mitigates the risk of applying flameless combustion to process heaters is GSF s proprietary fuel delivery system design. The GSF Conventional Heater with Flameless Firing capability is an integrated heat transfer system complete with a control monitoring and management system that safely and reliably transitions back and forth between 100% flameless, 50% conventional with 50% flameless and 100% conventional firing. The control system determines the appropriate firing mode based on local parameters and permissives. When necessary for start-up, shut-down or anytime an upset causes specified local temperatures to drop below the auto-ignition point, the control system will safely and reliably transition from flameless mode to conventional operation. A sketch of the combustion air and fuel nozzle is shown in Figure 5. During normal operation while firing in flameless mode, NOx emissions are in the single digits (3-8 ppm), without an SCR. Compared to conventional firing, fuel firing rates drop by up to 9% (up to 11% with maximum heat recovery), therefore other pollutant emissions including greenhouse gases (GHG) are reduced proportional to the efficiency increase and the plant saves money on fuel operating costs. Added benefits of the even radiant heat flux are clean tubes, elimination of hot spots and coking in the process tubes which provide longer run lengths and increased throughput. Additionally, flameless heater fuel nozzles have large single fuel ports thus eliminating the risk of plugging tips, the maintenance cost of frequent cleanings, and the need for a filter/coalescer. Page # 3

Figure 1. General arrangement of vertical tube, double fired cabin heater Page # 4

Figure 2. Elevation of coil end view Page # 5

Figure 3. Elevation of coil side view Page # 6

Figure 4. Plan view of coil Page # 7

Figure 5. Combustion air and fuel nozzle plan view Flameless Technology Economics We can expect that cost for potential GHG cap-and-trade will be set just below the cost for pre and post combustion systems as this will appear attractive to the end user (and will help offset the national deficit!); however, with simple submission to cap-and-trade tax cost, the end user gives up control and receives zero return on investment. Pre and post combustion processes will be quite costly and will increase operating and maintenance cost, but users will retain control. Note that return on investment will still be zero. The capital cost (equipment plus instrumentation and installation) of a GSF Conventional Heater with Flameless Firing capability is comparable to a typical conventional, double fired heater with a balanced draft, air pre-heat system. Additionally, savings include fuel energy efficiency, reduced maintenance, greater throughput and reduction of the need for emissions credit purchase so there is a measureable return on investment. The end user maintains control over costs (capital and operating) eliminating the unknowns associated with cap-and-trade. See Table 2 for a more detailed equipment cost comparison. Page # 8

Table 2. Flameless Technology Economic Comparison FLAMELESS MAXIMUM EFFICIENCY FLAMELESS BASELINE CONVENTIONAL NATURAL DRAFT Base Heater Cost, $ 3,000,000-4,000,000 3,000,000-4,000,000 3,000,000 Air Preheat Cost, $ 837,900 700,000 0.00 Yrs to Pay for Preheat System 0.87 0.88 NA Flame/Gas Impingement on Tubes No No Yes Increased Run Length Yes Yes No Increased Tube Life Yes Yes No Even Heat Transfer to Radiant Coil Yes Yes No Burner-Burner Flame Interaction No No Yes Multi-Burner Effect NOx Increase No No Yes Basis: Radiant Coil Configuration: Double Fired Absorbed Duty: 100 MMBtu/hr Fuel Composition: 30% H2, 50% CH4, 20% C3H8 15% Excess Air Fuel Cost: $8.00/MMBtu (LHV) Flameless Technology Summary With the flexibility of being able to seamlessly transition back and forth between flameless and conventional combustion, there is ZERO risk to meeting production goals and process heat requirements. GSF s Conventional Heater with Flameless Firing capability has the flexibility to operate with wide ranging fuel compositions, including up to 100% H 2 without negatively impacting NOx emissions. Therefore, flameless combustion is a perfect complement to precombustion CO 2 reduction technologies. As shown in Table 3, further CO 2 reduction can be achieved by increasing the hydrogen composition of the fuel gas. GSF s technology can also be designed to utilize 100% oxy-fuel combustion technology to further reduce the size of secondary CO 2 recovery systems that will likely be required in the future. Page # 9

Table 3. Flameless Technology Economic Comparison FLAMELESS MAXIMUM EFFICIENCY FLAMELESS BASELINE CONVENTIONAL NATURAL DRAFT Air Preheat Yes Yes No Combustion Air Temp, o F 890 890 60 Stack Temp, o F 240 300 650 Bridgewall Temp, o F 1,537 1,537 1,537 Heat Release (LHV), MMBtu/hr 107.5 109.9 121.2 Heater Efficiency (LHV), % 93 91 82.5 Heater Efficiency (HHV), % 83 81 72.5 Energy Savings (LHV), MMBtu/hr 13.7 11.3 NA CO, ppmvd <50 <50 <50 NOx, ppmvd corrected to 3% O2 3-8 3-8 20 NOx, lb/mmbtu (HHV).006.006.024 NOx, lb/hr 0.723 0.741 3.31 NOx reduction, lb/hr 2.587 2.569 NA NOx reduction, % 78.2 77.6 NA CO2, lb/hr 12,497.9 12,776.9 15,634.8 CO2 reduction, lb/hr 3,136.9 2,857.9 NA CO2 reduction, % 20.1 18.3 NA Basis: Radiant Coil Configuration: Double Fired Absorbed Duty: 100 MMBtu/hr Conv. Fuel Composition: 30% H2, 50% CH4, 20% C3H8 Flameless Fuel Composition: 60% H2, 20% CH4, 20% C3H8 15% Excess Air SUMMARY OF CD REQUIREMENTS FOR FLAMELESS TECHNOLOGY DEMONSTRATION HEATER As per CD requirements, on or before December 31, 2012, CRRM is required to install a new heater or modify an existing heater, with a rated capacity of at least 9.5 MMBtu/hr, which is capable of operating in Flameless Firing mode (hereinafter the Demonstration Heater ). The Demonstration Heater will be designed as follows: a. capable of operating in the following three modes: 100% Flameless Firing mode, combined flameless and Conventional Mode, and 100% Conventional Mode; b. capable of NOx emissions of <0.01 lbs/mmbtu (HHV) per hour at 3% O2 (dry) when operating in Flameless Firing mode (without SCR); c. available to operate 95% of the time; and d. 90% efficient on a lower heating value basis ( LHV ) when operating in Flameless Firing mode. CRRM is also required to operate the Demonstrator Heater from January 1, 2013 through December 31, 2013 and on or before March 31, 2013, is required to install and operate a continuous emissions monitoring system (CEMs) on the Demonstration Heater for the remainder of the Demonstration Period. Based on operating data collected during the Demonstration Period, CRRM is required to submit a report indicating whether the Demonstration Heater performs in accordance with the design and must propose a lb/mmbtu NOx emission limit on a 365-day rolling average basis. Page # 10

The results of the Demonstration Period are of significant importance to CRRM, for if the Demonstration Heater performs in accordance with the design, then on or before December 31, 2016, CRRM shall install a new heater or modify an existing heater ( Second Demonstration Heater ), with a firing rate of at least 40 MMBtu/hr, capable of operating in Flameless Firing mode. If required, the Second Demonstration Heater must be designed to the same specifications as the Demonstration Heater. If the Second Demonstration Heater requirement is triggered, CRRM will propose an emission limit for the Second Demonstration Heater by March 31, 2017. If CRRM installs or modifies a Second Demonstration Heater, it may move the CEMs from the Demonstration Heater to the Second Demonstration Heater. If CRRM does not install a Second Demonstration Heater, then after the Demonstration Period it may disconnect the CEMs from the Demonstration Heater. SELECTION OF FLAMELESS TECHNOLOGY DEMONSTRATION HEATER After evaluation of potential existing refinery process heaters at the refinery, CRRM has elected to install a new process heater to meet the CD Demonstration Heater requirements. The Demonstration Heater is designed with an absorbed heater duty of 9.5 MMBtu/hr and 14.5 MMBtu/hr (HHV) when used in the combined Flameless and Conventional modes. The Demonstration Heater will be installed in the No. 2 Crude Unit and will fire refinery fuel gas and natural gas as needed. The installation of the Demonstration Heater is planned so that it can operate independently in parallel with the main No. 2 Crude Unit charge heater. This design intuitively makes sense as it minimizes the potential impacts the operation of the Demonstration Heater can have on the No. 2 Crude Unit operation. Similarly, an increase in the No. 2 Crude Unit throughput is not planned to coincide with the Demonstration Heater installation as this also protects the refinery operations from any significant impacts based on the operation of the Demonstration Heater. Thus, if CRRM experiences any difficulties in the startup and/or continued operation of the Demonstration Heater, its impacts on the No. 2 Crude Unit can be minimized as the existing main No. 2 Crude Unit charge heater operates independently and is appropriately sized to handle the planned crude throughput. Additionally, in selection of the Demonstration Heater, CRRM considered the cost to install CEMs including the associated instrumentation lines. Installing this new heater in the No. 2 Crude Unit presented one of the more cost effective options for the CEMs and instrumentation installation. Moreover, the design of the CEMs package was developed to allow it to be used for the Second Demonstration Heater if the CD requirements for this were triggered. CRRM reviewed existing refinery process heaters and determined that there was not an existing suitable candidate heater for modification with a firing rate capacity near the 9.5 MMBtu/hr CD threshold. While larger existing process heaters can be modified with the Flameless technology, the cost for engineering and modification of these larger existing units was not desirable in comparison to a new Demonstration Heater. Additionally, CRRM did not have any existing plans for major modifications to any existing heaters that could have been implemented to include Flameless Technology within the CD required deadlines. CRRM also elected to install a new Demonstration Heater rather than modify an existing heater, as designing a new heater with this technology is beneficial in engineering the most reliable heater. While GSF is capable of retrofitting existing conventional heaters with its Flameless technology, the ability to design a new process heater creates greater freedom in the process heater design. The installation of a new Demonstration Heater as opposed to modification of an existing heater also helps CRRM assure compliance with the CD provisions for NOx EMISSION REDUCTIONS FROM HEATERS AND BOILERS 1. Specifically, if CRRM had selected an existing refinery process heater already subject to a permit limit or the CD provisions for NOx emission reductions, the refinery would 1 Section G Civ. No. 04 CV 1064 MLB. Page # 11

need to comply with not only the CD Demonstration Heater requirements but also the other applicable permit limits and/or CD requirements. Thus, in selecting to install a new Demonstration Heater rather than modify an existing process heater, CRRM effectively limited the potential to exceed any existing permit limits and/or comply with separate CD provisions regarding NOx emission reductions from heaters and boilers. To date an approval for the construction of the Demonstration Heater has been issued by the Kansas Department of Health and Environmental (KDHE) and CRRM has begun the project for its installation. The permitted emissions for the Demonstration Heater include NOx emissions based on vendor supplied factors of 0.096 lb NOx/MMBtu (Conventional Firing Mode), 0.048 lb NOx/MMBtu (Staged Fuel Mode), and 0.01 lb NOx/MMBtu (Flameless Mode). NOx emissions were calculated based on the maximum design firing rate for the heater and based on 15% operation in the Conventional Firing Mode, 15% in the Staged Fuel Mode, and 70% in the Flameless Mode. SUMMARY Flameless technology could be a key factor in providing an economically feasible mechanism to meeting anticipated future lower emission limits from process heaters. Flameless technology combined with pre and post combustion technologies can further reduce emissions in order to meet long term compliance requirements. The results to come from CRRM s CD required Demonstration Heater will be of great interest to both the petroleum refining and petrochemical industries as its application may determine a new preferred, cost effective technology to be utilized for process heaters. Page # 12