ASSURIX Intrinsically Safe Photoelectronic Sensors 3-wire construction Operating Manual and Control Drawing No. OM-AX-01

Similar documents
ASSURIX Intrinsically Safe Photoelectronic Sensors

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Inductive slot sensor

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

PEPPERL+FUCHS GmbH

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. Dimensions

Technical Data. Dimensions

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

DB5 Intrinsically Safe Sounder Type DB-5

4) Intrinsic Safety Certification

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Tank Gauging System Special Safety Instruction

Operating Manual MS220DA

Technical Data. Dimensions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

SET-2000 Hi Level/Oil

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Technical Data. Dimensions

SET Installation and Operating Instructions. Level switch for one sensor

OilSET-1000 (12 VDC)

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

INSTRUCTION & SERVICE MANUAL

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

SET-2000 Oil/Sludge 12 VDC

COMPACT FLAME CONTROLLER CFC 2000

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

VERSAFLOW VORTEX Supplementary instructions

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 1000

INSTRUCTION MANUAL. Frequency-Pulse Converter, Repeater and Trip Amplifiers Din-Rail Model D1060S D1060S

FDOOT241-A9-Ex Multisensor fire detector

Manual Isolating Barrier D461R1 (Revision 01)

INSTRUCTION MANUAL (ATEX)

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Laser Distance Sensor Type M Analog-Output

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

INSTRUCTION MANUAL (ATEX / IECEx)

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

2 General Application Photoelectric Sensors

OPTIBAR DP 7060 Supplementary Instructions

Class 1 laser beam sensor safe for your eyes

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Manual Isolating Barrier D461 (Revision 05)

Laser Collimated Beam Sensor

Class 1 laser beam sensor safe for your eyes

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

2 General Application Photoelectric Sensors

INSTALLATION AND OPERATING MANUAL

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Instrumentation Products and Applications

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Class 1 laser beam sensor safe for your eyes

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

IECEx Certificate of Conformity

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

Certificate of Compliance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

OOH740-A9-Ex Multi-sensor fire detector

EU DECLARATION OF CONFORMITY

OOH740-A9-Ex Multisensor fire detector

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

AND INSTALLATION MANUAL

PROTECT SRB 200EXi-1A

Declaration of conformity

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Operating Instructions Edition 02/2007

Certificate of Compliance

Model 144H. Product Data Sheet , Rev DB February Content

Annubar Flowmeter Series

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Installation and Operating Instruction

PumpSaver ISS-105 IS Super Cell Installation Guide

Certificate of Compliance

RT FLOW RATE TOTALISER

Transcription:

ISO 9001:2000 / ATEX ASSURIX Intrinsically Safe Photoelectronic Sensors 3wire construction Operating Manual and Control Drawing No. OMAX01 0158 II 2 G EEx ia IIC T6 24VL applicable in Ex Zones 1, 2 / CL I, CL II, CL III, Division 1, GR ABCDEFG, HAZARDOUS LOCATIONS. Intrinsically Safe EEx ia IIC T6. CLASSIFIED BY UNDERWRITER'S LABORATORIES INC. ASSIGNED CONTROL No. 24VL. ATEX Certification DMT 03 ATEX E003 Types Light Barriers Proximity Switch Retroreflective Barriers Technical Data Type of Ex protection EEx ia IIC T6, applicable in zones 1 and 2 Designation AXSE25P18 AXSE50P30 AXT5P18 AXT10P18 AXR1P18 AXR4P30 AXSE25P30 AXT5P30 AXT10P30 Marking S:Emitter / E: Receiver T: Proximity switch R: Retroreflective barrier Range 25m 50m 0.5m Note1 1m Note1 1m Note2 4m Note2 Housing...P18 = M18 M30...P18=M18...P18=M18 M18 M30 (Yellow brass, nickel plated)...p30=m30...p30=m30...p30=m30 Light wave length 880nm 880nm 880nm 880nm 625nm 625nm maximum radiant intensity 2.6mW/mm 2 2.6mW/mm 2 1.2mW/mm 2 6.2mW/mm 2 0.6mW/mm 2 0.6mW/mm 2 Power supply VDC (intrinsically safe) Current consumption 13mA 13mA 15mA 15mA 15mA 15mA Safety ratings Vi <=13.6VDC / Ii <= 0mA /Pi <= 800mW (in accordance with the power supply) effective capacity / inductance Ci = 150pF / Li = 7.92uH Response 50Hz 50Hz 100Hz 100Hz 100Hz 100Hz PNP, short circuit protected Operating temperature TA 20 C < TA < +60 C Protection rating IP65 EN 60529 Cable, Length: 3m, Emitter: 2 x AWG24 3xAWG24 3xAWG24 shielded, blue covered Receiver: 3xAWG24 Fibre optics connection only types M30 Accessories M18: 4 nuts M18 M18: 2 nuts M18 2 nuts M18 2 nuts M30 M30: 4 nuts M30 M30: 2 nuts M30 Options Light barrier with 10kHz response: Type AXSE10P18 Light barrier with a range of 100m: Type AXSE100P30 Light barrier for fibre optics: Types AXSE56P30GF (High density), AXSE25/50P30GF maximum radiant intensity <= 3.2mW/mm 2 with connected fibre optics Device with 90 viewing angle: AXR1P18/90 Light barriers series S17: With connector M18: Type AXS/E..P30 S17: Socket M18: Binder series 714, 4 terminals, housing M30, inside the socket for receiver and emitter Series S92, housing M30: Socket M/4P, without potentiometer, in the socket Series S99, housing M30: Socket M/ 5P, with Potentiometer and Devices with special high flexible cable for trailing: Types AX..S74 Reflector (triple mirror for retroreflective barriers, D=83mm Function and indication Light barriers Proximity switch Light beam not interrupted Light beam free / Reflection detected Light beam interrupted Light beam interrupted / no reflection Retroreflective barriers Light beam not interrupted Light beam interrupted = ON = OFF function: Inverted output function by changing the polarity of the supply voltage. +VDC OUT 0V +VDC OUT 0V Connection diagram:: Devices with Socket S17: Socket S92: Socket S99: cable connection (Pin 4: Not connected) (Pin:2: Not connected) +VDC Brown Pin 1 Pin 1 Pin 1 0V: Blue Pin 3 Pin 3 Pin 3 : Black Pin 2 Pin 2 Pin 4 Protection earth PA At the housing Pin 4 At the housing Pin 5 Cable shield blank or white Note 1: Range on white paper 30cm x 20cm. Note 2: Range on reflector (Triple mirror) D=83mm

Control Drawing for Hazardous Areas: Hazardous Area Zones 1, 2 CL I, GR ABCD / CL II, GR EFG, CL III control Ex ia Sensor Nonhazardous Area brown + black output blue shield [Ex ia] Power Supply Electrically Isolating Vmax >= Voc Vmax = 13.6V Maximum ratings for the power supply Imax >= Ioc Imax = 0mA Vo <= 13.6V Ci + Ccable <= Ca Ci = 150pF Io <= 0mA Li + Lcablel <= La L = 7.92uH Po <= 800mW TA <= 60 Equipotential Bonding prescription: 34567890345678901 34567890345678901 34567890345678901 34567890345678901 34567890345678901 Power Input 24/115/230VAC RelayContact or electronic The end of the cable must be connected outside the hazardous location. The local equipotential bonding 34567890345678901 have to be done with conductive3456789034567890345678903456789034567890345678903456789 corrosionresistant clamps or nuts M18/M30 3456789034567890345678903456789034567890345678903456789 The cable shield is to connect at 0V() of the supply voltage. ATEX related designations CE 0158 Manufacturer with address Device type II 2 G EEx ia IIC T6 Certification number: DMT 03 ATEX E 003 TA: 20 < TA < 60 Electrical data according to the chart Date of construction: Numeral 4 to 7 of the serial number Dimensions light barriers Dimensions proximity switch Dimensions retroreflective barriers 130 105 118.5 45 52 33 137 30 100 7 102 30 65 7 S92: Socket M Operating Manual / EC Declaration of Conformity: M30x1.5 M30x1.5 in Socket S99: Socket M 45 55 5 102 30 65 7 115 32 80 3 Matrix Elektronik AG (Manufacturer) Tippkemper Matrix GmbH Kirchweg 24 CH5420 Ehrendingen Meegener Str. 43 D51491 Overath Tel.:+41 56 2040020 Fax 29 Tel.:+49 2206 95660 Fax 19 M30x1.5 M30x1.5 Mounting prescriptions: ExProtection It is necessary to take into consideration the valid international and national rules and regulations (EN 6007914). The electrical connections must be exactly as shown in the control drawing for hazardous areas. The local equipotential bonding have to be done by a reliable, noncorrosive holding of the protection earth connection. The cable must be protected against damages. To connect cables inside the hazardous locations, only use certificated Ex e housings. Only original manufacture optical parts must be used. Other additional optical lenses or fibre optics are not allowed in hazardous locations. The sensor must only be supplied by an approved intrinsically safe power supply type [EEx ia], mounted out of the hazardous location. Connector versions: The maximum rates of capacity and inductance of the connection cable must be respected. Function Light barriers: If the light beam is not interrupted the output switches to ON (+V). If the light beam is interrupted the output switches to OFF. The load must be connected between the output and 0V. Proximity Switches: If the sensor detects reflected light, by any object, the output is switching ON (HLevel). If the sensor detects no reflected light, the output is switched OFF. Retroreflective light barriers: If the light beam the sensor and the reflector, is not interrupted the output switches to ON (+V). If the light beam is interrupted the output switches to OFF. The load must be connected between the output and 0V. Mode (XFunction): By changing the polarity of the supply voltage (Blue +, Brown), the output mode will be reversed. The function will remain unchanged. Maintenance No special maintenance is required. Cleaning only with a nonaggressive cleaning liquid. Safety Informations The sensors of the aeries AX.. must not be used for Accident Prevention! When installing and operating with the light barrier, it is necessary to take into consideration the relevant international and other national regulations. ATEX 118a, ElexV, TRbF, TRD, UVV, EXRL, BetrSichV, UL508, UL913 Intrinsically Safe Apparatus and Associated Apparatus for use in Class I, II, III Division 1, Hazardous (Classified) Locations. There is no risk on eye injuries by the diode emitters. The maximum possible exposure is less then the ratings described by the standard EN 608251/item 13). Standards met: EN 50014, EN 50020; EN 500811/2, EN 500821/2, Ex protection: 94/9/EG (ATEX 100a), UL 913 Machine directive: 98/37/EG Low volatge directive: 73/23/EWG RoHS directive: 2002/95/EG General Notes We reserve the right to modify our equipment. Our equipment is designed in accordance with the RoHS directive. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. Declaration of Conformity / Approvals: DMT 03 ATEX E 003 ULClassified, Assigned Control No. 24VL / E185916 The conformity of the devices with the EC/UL standards and directives and the EC/ULtype examination certificate and the observation of the Quality Safety System ISO 9001:2000 with the ATEX module "Production", declares: Hans Bracher, Matrix Elektronik AG 45 63 10.5 3 45 52 8 16 34567 34567 34567 34567 34567 34567 34567 25 30 58 20 20 28 M30x1.5 OmAx01_e16//MAY22,06/HB

II 2 G EEx ia IIC T6 ISO 9001:2000 / ATEX ASSURIX Intrinsically Safe Photoelectronic Sensors NAMUR types 0158 Operating Manual and Control Drawing No. OMAX02 applicable in Ex Zones 1, 2 / CL I, GR ABCD, CL II GR EFG, CL III HAZARDOUS LOCATIONS. Intrinsically Safe EEx ia IIC T6. CLASSIFIED BY UNDERWRITER'S LABORATORIES INC. ASSIGNED CONTROL No. 24VL. ATEX Certification DMT 03 ATEX E003 Types Light Barriers Proximity Switch Retroreflective Barriers Technical Data Type of Ex protection EEx ia IIC T6, applicable in zones 1 and 2 Designation AXSE10N AXSE10P AXT3NN18 AXT3PN18 AXR1NN18 AXR1PN18 N18 N18 AXT3NN30 AXT3PN30 Marking S:Emitter / E: Receiver T: Proximity switch R: Retroreflective barrier Range 10m 10m 0.3m Note1 0.3m Note1 1m Note2 1m Note2 Housing M18 M18...N18=M18...P18=M18 M18 M18 (Yellow brass, nickel plated)...n30=m30...p30=m30 Light wave length 880nm 880nm 880nm 880nm 625nm 625nm maximum radiant intensity 2.6mW/mm 2 2.6mW/mm 2 1.2mW/mm 2 6.2mW/mm 2 0.6mW/mm 2 0.6mW/mm 2 Nominal supply voltage 8.2VDC (intrinsically safe) Current consumption 3.5mA 3.5mA 2.5mA 2.5mA 2.5mA 2.5mA Safety ratings Vi <=13.6VDC / Ii <= 0mA /Pi <= 800mW (in accordance with the power supply) effective capacity / inductivity Ci = 0pF / Li = 5.28uH Response time 25Hz 25Hz 100Hz 100Hz 100Hz 100Hz no output, status indication by current consumption (NAMUR specification) Operating temperature TA 20 C < TA < +60 C Protection rating IP65 EN 60529 Cable, Length: 2m, Emitter: 2 x AWG24 2xAWG24 2xAWG24 shielded, blue covered Receiver:2xAWG24 Fibre optics connection only types M30 Accessories 4 nuts M18 M18: 2 nuts M18 2 nuts M18 (2 clamps M18, optional) M30: 2 nuts M30 (1 clamp M18, optional) Options Device with 90 viewing angle: AXR1N/1PN1890 Retroreflective light barrier with potentiometer: AXR1N/1PN18 S87 Retroreflective light barrier, range=4m, housing M30: AXR4N/4PN30 Sensors with connector M: AX... S92 Proximity switch, range=10cm, switching frequency= 1kHz AXT1.N30 Proximity switch, range=20cm, switching frequency= 700Hz AXT1.N30 Devices with special high flexible cable for trailing: AX... S74 The devices S74 are not UL approved! Reflector (triple mirror for retroreflective barriers, D=83mm Function and indication Light barriers Light beam not interrupted Light beam interrupted Proximity switch Light beam free / Reflection detected Light beam interrupted / no reflection Retroreflective barriers Function and indication Sensors Type "N" AXE10NN18 AXT3NN18 AXT3NN30 AXR1NN18 Function and indication Sensors Type "P" AXE10PN18 AXT3PN18 AXT3PN30 AXR1PN18 Note 1: Range on white paper 30cm x 20cm. Light beam not interrupted = ON I > 2mA = ON I < 1mA = OFF + brown / 1 2+4=NC blue / 3 + brown / 1 2+4=NC blue / 3 Note 2: Range on reflector (Triple mirror) D=83mm Light beam interrupted = OFF I < 1mA = OFF I > 2mA = ON + brown / 1 2+4=NC blue / 3 + brown / 1 2+4=NC blue / 3

Control Drawing for Hazardous Areas: Hazardous Area Nonhazardous Area Zones 1, 2 CL I, GR ABCD / CL II, GR EFG, CL III EEx ia NAMUR Sensor [EEx ia] Power Supply brown / 1 + control blue / 3 shield Vmax <= Voc Vmax = 13.6V Maximum ratings for the power supply Imax <= Ioc Imax = 0mA Vo <= 13.6V Ci + Ccable <= Ca Ci = 0pF Io <= 0mA Li + Lcablel <= La Li = 5.28uH Po <= 800mW TA <= 60 Equipotential Bonding prescription: The local equipotential bonding 3456789034567890 have to be done with conductive3456789034567890345678903456789034567890345678903456789 3456 corrosionresistant clamps or nuts M18/M30 3456789034567890345678903456789034567890345678903456789 The cable shield is to connect at 0V() of the supply voltage. ATEX related designations CE 0158 Manufacturer with address Device type II 2 G Certification number: DMT 03 ATEX E 003 TA: 20 < TA < 60 Electrical data according to the chart Date of construction: Numeral 4 and 5 of the serial number Dimensions light barriers Dimensions proximity switch Dimensions retroreflective barriers 130 3456789034567890 3456789034567890 3456789034567890 3456789034567890 3456789034567890 105 Electrically Isolating 3 118.5 Power Input 24/115/230VAC or 24VDC RelayContact or electronic The end of the cable must be connected outside the hazardous location. 45 52 33 45 55 5 102 30 65 7 M30x1.5 45 63 10.5 3 45 52 16 34567 34567 34567 34567 34567 34567 34567 25 28 Operating Manual / EC Declaration of Conformity: Mounting prescriptions: ExProtection It is necessary to take into consideration the valid international and national rules and regulations. The electrical connections must be exactly as shown in the control drawing for hazardous areas. The local equipotential bonding have to be done by a reliable, noncorrosive holding of the protection earth connection. The cable must be protected against damages. To connect cables inside the hazardous locations, only use certificated Ex e housings. Only original manufacture optical parts must be used. Other additional optical lenses or fibre optics are not allowed in hazardous locations. The sensor must only be supplied by an approved intrinsically safe power supply type [EEx ia], mounted out of the hazardous location. Connector versions: The maximum rates of capacity and inductivity of the connection cable must be respected. Function Light barriers and retroreflective light barriers "N" types: When the light beam is not interrupted the current consumption will be >= 2mA and the lights up. When the light beam is interrupted the current consumption is reduced to <=1mA and the switches OFF. Light barriers and retroreflective light barriers "P" types: When the light beam is not interrupted the current consumption will be <= 1mA and the switches OFF. When the light beam is interrupted the current consumption is increased to >=2mA and the lights up. Proximity Switches "N" types: When the sensor detects diffused reflected light, the current consumption will be >= 2mA and the lights up. When no light will be detected the current consumption is reduced to <=1mA and the switches OFF. Proximity Switches "P" types: When the sensor detects diffused reflected light, the current consumption will be <=1mA and the switches OFF. When no light will be detected the current consumption is increased to >=2mA and the lights up. Maintenance No special maintenance is required. Cleaning only with a nonaggressive cleaning liquid. Matrix Elektronik AG (Manufacturer) Tippkemper Matrix GmbH Kirchweg 24 CH5422 Oberehrendingen Meegener Str. 43 D51491 Overath Tel.:+41 (0) 56/2220757 Fax 563 Tel.:+49 (0) 2206/95660 Fax 19 Fibre optics For efficiently detection solutions look for our multiple program of fibre optics, also for high temperature areas. Safety Informations The sensors of the aeries AX.. must not be used for Accident Prevention! When installing and operating with the light barrier, it is necessary to take into consideration the relevant international and other national regulations. ATEX 118a, ElexV, TRbF, TRD, UVV, EXRL(BGR104), BetrSichV(ATEX137), UL508, UL913 Intrinsically Safe Apparatus and Associated Apparatus for use in Class I, II, III Division 1, Hazardous (Classified) Locations. There is no risk on eye injuries by the diode emitters. The maximum possible exposure is less then the ratings described by the standard EN 608251/ item 13). Standards met: EN 50014, EN 50020, UL 508, UL 913 EN 6100061/2, EN 6100063/4; EN 60529 Ex Protection: 94/9/EG (ATEX 100a) Machine directive: 98/37/EG Low voltage directive: 73/23/EWG, 93/68/EWG EMC: 89/336/EWG, 91/263/EWG, 92/31/EWG, 93/68/EWG General Notes We reserve the right to modify our equipment. Our equipment is designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. Declaration of Conformity and Approvals Approvals: DMT 03 ATEX E 003, ULClassified, Assigned Control No. 24VL / E185916 The conformity of the devices with the EC/UL standards and directives and the EC/ULtype examination certificate and the observation of the Quality Safety System ISO 9001 with the ATEX module "Production", declares: Hans Bracher, Matrix Elektronik AG OmAx02_e8/APR.01,05/HB

ASSURIX Intrinsically Safe Laser Light Barrier AXLS/E51 Operating Manual and Control Drawing No. OmAxL1e 0158 ISO 9001 ATEX II 2G Applicable in Hazardous Locations, ExZone 1 and 2 Intrinsically Safe Protection Level EEx ia IIC T6 Laser Class 2 (BG Approval) High EMC reliability ATEX approved Type AXLS/E51 Technical Data Designation S: Emitter / E: Receiver Laser Class / Laser Power Class 2 / P < 1mW Laser Beam Diameter ~ 8mm at a distance of 10m Wave Length 640680nm / visible red Range 50m Minimum Detectable Object Size 11mm (without additional slipon diaphragm) Switching Frequency 1000Hz Response Time 0.5ms Connection Values Exi Power supply VO <=8.6VDC / IO <= 0mA /PO <= 800mW Supply Voltage 7.0 VDC up to max. 8,6 VDC intrinsically safe Current Consumption (Normal Modus) Emitter: 35 ma / Receiver: 6mA Max. Power Dissipation ( Normal Modus) Transmitter: 300mW / Receiver: 52mW 1 x PushPull Impedance 60W Housing M18 Yellow Brass, Nickel Plated Enclosure Rating IP 65 according to EN 60529 Operating Temperature TA 0 C < TA < +50 C Connecting Cable Emitter 2 x AWG24 (0.2mm 2 ) + / L=3m / blue covered Connecting Cable Receiver 3 x AWG24 (0.2mm 2 ) + / L=3m / blue covered Accessories included 2 Clamps M18 or 4 Nuts M18 Options Plugtype connector (Binder M18, Series 714), Designation: AXLS/E51C Cable Length up to 100m Devices with special high flexible cable for trailing, Designation AXLS/E51K Slipon Diaphragms 5mm to 1mm Indication Function Light Beam Interrupted Light Beam not interrupted extinguished shows yellow Connection Layout Receiver: Standard Highflex Connector brown brown 1 = + blue white 3 = black green 2 = white blank = Emitter: Standard Highflex Connector brown brown 1 = + blue white 3 = white blank = PNP=OFF NPN=ON +8.6VDC Out PNP=ON +8.6VDC Out NPN=OFF

Dimensions: Connector:mm (Same Dimensions for Emitter and Receiver) at the Receiver. Connector Version: 1 Inside the Connector 45 52 33 + Control Drawing for Hazardous Areas: Zone 1,2 Hazardous Area Nonhazardous Area Ex ia AXLS/E51 [Ex ia] Power Supply e.g. NEX1/8.2V (1) brown + Control (3) black Out Electrically Isolating (2) blue Max. Values for the Power Supply Vi = 8.6V Vo <= 8.6V Ii = 0mA Pi = 800mW Io <= 0mA Po <= 800mW Ci = 214pF per m Cable Co >= 30nF Li = 11uH per m Cable Lo >= 1.2mH Equipotential Bonding: The local equipotential Bonding have to be done with conductive corrosionresistant clamps or nuts M18 23456789034567890345 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567 1 34567890345678903456789034567890345678903456789034567890345678903456 34567890345678903456789034567890345678903456789034567890345678903456 Mounting prescriptions Lenght Receiver: 130 Lenght Emitter: 110 ExProtection It is necessary to take into consideration the valid international and national rules and regulations. The electrical connections must be exactly as shown in the control drawing for hazardous areas. The local equipotential bonding have to be done by a reliable, noncorrosive holding of the protection earth connection. The cable must be protected against damages. To connect cables inside the hazardous locations, only use certificated Ex e housings. Additional optical lenses are not allowed in hazardous locations. The sensor must only be supplied by an approved intrinsically safe power supply type [EEx ia], mounted out of the hazardous location. Connector versions: The maximum rates of capacity and inductivity of the connection cable must be respected. Mounting Prescriptions Because Lasers have a very small aperture angle, mount the light barriers free from vibrations and shocks. If it is practicable, protect the lenses from contamination. Do not exceed the maximum ratings. The electrical connections must exactly as shown in the connection layout. The cable shield must be connected short. The cable shield should be connected to the protection earth, large surfaced. Connection cables must not be installed parallel to high voltage cables. Operating Manual Connection layout for connector versions..c View on the pins at the sensor 2 Out Power Input e.g. 115/230VAC The end of the cable must be connected outside the hazardous locations to an intrinsically safe power supply. connected to PE largesurfaced 3 4 PE e.g.relay Contact or Optocoupler Laser Safety Safety Notes for Laser Installations of Class 2. The instructions for planning and installation must be followed in accordance with EN 608251 Do not stare into Laser Beam General Safety Informations For installing and using the Laser Light Barrier it is necessary to take into consideration the relevant international and other national regulations: ATEX118a, EXRL, ElexV, TrbF, TRD, UVV Standards met: EN 50014, EN 50020, EN 500811/2, EN 500821/2, EN 608251 ExProtection 94/9/EG (ATEX 100a) Machine Directive 89/392/EWG, 91/368/EWG, 93/44/EWG, 93/68/EWG Low Voltage Directive 73/23/EWG, 93/68/EWG EMC 89/336/EWG, 91/263/EWG, 92/31/EWG, 93/68/EWG Maintenance The Laser Light Barrier does not require any special maintenance. Contaminated lenses are to clean with a non aggressive medium. Equipment must only be repaired or serviced by the manufacturer. General Notes Function: We reserve the right to modify our equipment. Our equipment If the light beam between emitter and receiver is not interrupted is designed such way, that it has the least possible adverse the PNPTransistor is switched ON (H level) and the NPN effect on the environment. It neither emit or contain any Transistor is switched OFF. If the light beam between emitter damaging or siliconized substances and use a minimum of and receiver is interrupted the PNPTransistor is switched OFF energy and resources. No longer usable or irreparable units (L level) and the NPNTransistor is switched ON. must be disposed of in accordance with local waste disposal regulations. Approvals DMT 00 ATEX E020 OmAxL1_e1,SEP.,00/HB Group Tippkemper Matrix GmbH Matrix Elektronik AG Meegener Str. 43 D51491 Overath Kirchweg 24 CH5422 Oberehrendingen Tel.:+49 (0) 2206/95660 Fax 19 Tel.:+41 (0) 56/2220757 Fax 563

ASSURIX Intrinsically Safe Laser Light Barrier AXLS/E80 Operating Manual and Control Drawing No. OmAxL0e 0158 ISO 9001 ATEX II 2G Applicable in Hazardous Locations, ExZone 1 and 2 Intrinsically Safe Protection Level EEx ia IIC T6 Laser Class 2 (BG Approval) High EMC reliability ATEX approved Type AXLS/E80 Technical Data Designation S: Emitter / E: Receiver Laser Class / Laser Power Class 2 / P < 1mW Laser Beam Diameter ~ 8mm at a distance of 10m Wave Length 640680nm / visible red Range 80m Minimum Detectable Object Size 20mm Switching Frequency 1000Hz Response Time 0.5ms Connection Values Exi Power supply VO <=8.6VDC / IO <= 0mA /PO <= 800mW Supply Voltage 7.0 VDC up to max. 8,6 VDC intrinsically safe Current Consumption (Normal Modus) Emitter: 35 ma / Receiver: 6mA Max. Power Dissipation ( Normal Modus) Transmitter: 300mW / Receiver: 52mW 1 x PushPull Impedance 60W Housing M30 Yellow Brass, Nickel Plated Enclosure Rating IP 65 according to EN 60529 Operating Temperature TA 0 C < TA < +50 C Connecting Cable Emitter 2 x AWG24 (0.2mm 2 ) + / L=3m / blue covered Connecting Cable Receiver 3 x AWG24 (0.2mm 2 ) + / L=3m / blue covered Accessories included 2 Clamps M30 or 4 Nuts M30 Options Plugtype connector (Binder M30/M18, Series 714), Designation: AXLS/E80C Cable Length up to 100m Devices with special high flexible cable for trailing, Designation AXLS/E80K Slipon Diaphragms 5mm to 1mm Indication Function Light Beam Interrupted Light Beam not interrupted extinguished shows yellow Connection Layout Receiver: Standard Highflex Connector brown brown 1 = + blue white 3 = black green 2 = white blank = Emitter: Standard Highflex Connector brown brown 1 = + blue white 3 = white blank = PNP=OFF NPN=ON +8.6VDC Out PNP=ON +8.6VDC Out NPN=OFF

Dimensions: (Same Dimensions for Emitter and Receiver) Connector:17mm 30 135 100 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 3456789034567890345678903 at the Receiver Connector Version: inside the Connector 1 + Control Drawing for Hazardous Areas: Zone 1,2 Hazardous Area Nonhazardous Area Ex ia AXLS/E80 [Ex ia] Power Supply e.g. NEX1/8.2V (1) brown + Control (3) black Out Electrically Isolating (2) blue Max. Values for the Power Supply Vi = 8.6V Vo <= 8.6V Ii = 0mA Pi = 800mW Io <= 0mA Po <= 800mW Ci = 214pF per m Cable Co >= 30nF Li = 11uH per m Cable Lo >= 1.2mH Equipotential Bonding: The local equipotential Bonding have to be done with conductive corrosionresistant clamps or nuts M30 23456789034567890345 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567890345678903456 34567 1 34567890345678903456789034567890345678903456789034567890345678903456 34567890345678903456789034567890345678903456789034567890345678903456 Mounting prescriptions ExProtection It is necessary to take into consideration the valid international and national rules and regulations. The electrical connections must be exactly as shown in the control drawing for hazardous areas. The local equipotential bonding have to be done by a reliable, noncorrosive holding of the protection earth connection. The cable must be protected against damages. To connect cables inside the hazardous locations, only use certificated Ex e housings. Additional optical lenses are not allowed in hazardous locations. The sensor must only be supplied by an approved intrinsically safe power supply type [EEx ia], mounted out of the hazardous location. Connector versions: The maximum rates of capacity and inductivity of the connection cable must be respected. Mounting Prescriptions Because Lasers have a very small aperture angle, mount the light barriers free from vibrations and shocks. If it is practicable, protect the lenses from contamination. Do not exceed the maximum ratings. The electrical connections must exactly as shown in the connection layout. The cable shield must be connected short. The cable shield should be connected to the protection earth, large surfaced. Connection cables must not be installed parallel to high voltage cables. Operating Manual M30 x 1,5 Connection layout for connector versions..c View on the pins at the sensor 2 Out Power Input e.g. 115/230VAC The end of the cable must be connected outside the hazardous locations to an intrinsically safe power supply. connected to PE largesurfaced 3 4 PE e.g.relay Contact or Optocoupler Laser Safety Safety Notes for Laser Installations of Class 2. The instructions for planning and installation must be followed in accordance with EN 608251 Do not stare into Laser Beam General Safety Informations For installing and using the Laser Light Barrier it is necessary to take into consideration the relevant international and other national regulations: ATEX118a, EXRL, ElexV, TrbF, TRD, UVV Standards met: EN 50014, EN 50020, EN 500811/2, EN 500821/2, EN 608251 ExProtection 94/9/EG (ATEX 100a) Machine Directive 89/392/EWG, 91/368/EWG, 93/44/EWG, 93/68/EWG Low Voltage Directive 73/23/EWG, 93/68/EWG EMC 89/336/EWG, 91/263/EWG, 92/31/EWG, 93/68/EWG Maintenance The Laser Light Barrier does not require any special maintenance. Contaminated lenses are to clean with a non aggressive medium. Equipment must only be repaired or serviced by the manufacturer. General Notes Function: We reserve the right to modify our equipment. Our equipment If the light beam between emitter and receiver is not interrupted is designed such way, that it has the least possible adverse the PNPTransistor is switched ON (H level) and the NPN effect on the environment. It neither emit or contain any Transistor is switched OFF. If the light beam between emitter damaging or siliconized substances and use a minimum of and receiver is interrupted the PNPTransistor is switched OFF energy and resources. No longer usable or irreparable units (L level) and the NPNTransistor is switched ON. must be disposed of in accordance with local waste disposal regulations. Approvals DMT 00 ATEX E020 OmAxL0_e1,SEP.,00/HB Group Tippkemper Matrix GmbH Matrix Elektronik AG Meegener Str. 43 D51491 Overath Kirchweg 24 CH5422 Oberehrendingen Tel.:+49 (0) 2206/95660 Fax 19 Tel.:+41 (0) 56/2220757 Fax 563

II (2) G [EEx ia] IIC ASSURIX Intrinsically Safe Power Supply NEX1..AC Operating Manual and Control Drawing No. OMNEX01a ISO 9001:2000 / ATEX Power Supply for 3wire and NAMUR EEx ia Sensors. Process Control Equipment for Hazardous locations. Type of protection: Intrinsically Safe [EEx ia] IIC Listed by Underwriter's Laboratories Inc. Assigned Control No. 36HN Int. Safe Connections Cl.I, II,III Division 1, Applicable Gp.AG EU Certification of Conformity PTB 03 ATEX 2091 with Relay or Electronic. also available with adjustable delay function. Types NEX1R...VAC NEX1E...VAC NEX1RZ...VAC NEX1EZ...VAC Specifications Supply Voltage NEX1.24VAC 24VAC / 100mA (5060Hz) (Vm=250VAC) NEX1.115VAC 115 VAC / 40mA (5060Hz) (Vm=250VAC) NEX1.230VAC 230 VAC / 20mA (5060Hz) (Vm=250VAC) Connections 1 proximityswitch or 1 light barrier or 1 NAMURsensor Intrinsically safe output voltage for 3wire Sensors VDC (Vo = 13.6 VDC) Intrinsically safe output voltage for NAMUR sensors 8.2 VDC (Vo = 13.6 VDC) Maximum output current Io = 111mA Max. usable output current 30mA Maximum output power Po = 785mW Max. capacitive load Co = 250nF Max. inductive load Lo = 1.4mH Switching frequency 5 Hz 1kHz 5Hz 10Hz Time delay 0.1 to 10sec. 0.1 to 10sec. Dropin and Dropout Delay adjustable adjustable Relay OptoCoupler Relay OptoCoupler Maximum AC load 250VAC/4A/100VA 250VAC/4A/100VA Cos ϕ >= 0,7 Cos ϕ> = 0,7 Maximum DC load 30VDC/4A 28VDC/50mA 30VDC/4A 28VDC/50mA 100W 1W 100W 1W Housing Synthetic (Polycarbonate, Polystyrole) Protection rating IP 20 at EN 60529 Ambient temperature range 0 C < TA < 60 C Mounting On rail EN 50022 or with 2 screws Options (not UL LISTED) with NPN input circuit, Type NEX1...N (without NAMUR input) or + max. 28VDC Collector Pin 1 + max. 28VDC R > 820Ω Connection to the Optocoupler: (Only for devices with Coupler) Dimensions: 0158 Emitter Pin 2 Signal 0V to VDC10% R > 820Ω Collector Emitter Pin 1 Pin 2 Signal 1V to VDC 62,5 60 36 75 4,8 37,5 35 50 110

Control Drawing for Hazardous Areas: Hazardous Area NonHazardous Area Zone 1, 2; Division 1 Control Ex ia Sensor Vmax >= Voc TA <= 60 C Imax >= Ioc Vmax = 13,6V Li + LCablel <= Lo Imax = 111mA Ci + CCable <= Co Ci max = 250nF Li max = 1.4mH Connections: NAMURSensors to NEX1R 3456 3456 NAMUR Emitter S blue E+ brown S+ brown E blue brown + black Sig NEX1.. [EEx ia] Power Supply Electrically Isolating and Circuit blue Max. Values Power Supply NEX1 Vo = 13.6V Io = 111mA Po = 785mW Co = 250nF Lo = 1.4mH 3456 3456 NAMUR Receiver Pin 10: do not connect any wire. Power Input 24/115/230VAC Relay Contact or OptoCoupler 3wire Sensors to NEX1EZ 3456 3456 3456 Emitter 3456 3456 3456 Receiver + brown blue black Pin 11 / NDevices: NPNInput. 11 10 9 V NPN PNP 0V Intrinsically Safe Circuit max. 250VAC/4A/100VA 30VDC/4A/100W Intrinsically safe power supply. Type: NEX1 RN230VAC N Ph 1 2 3 4 5 6 Connect proximity switch same way as light barrier receiver. 11 10 9 V NAMUR PNP 0V Intrinsically Safe Circuit Delay Intrinsically safe power supply. Type: max. 28VDC/50mA NEX1 EZ230VAC NC N Ph 1 2 3 4 5 6 Pin 11 / Other Devices: do not connect any wire. Connect proximity switch same way as light barrier receiver. Operating Manual / EC Declaration of Conformity: Mounting prescriptions: WARNING: "To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing ExProtection The power supply must be installed out of the explosion risk area. The stated limit values must not be exceeded. The power supply must only be used with the voltage shown on the identification label. The connection for the intrinsically safe circuit is marked in blue. The power supply must only drive approved EEx ia intrinsically safe sensors. Function: The power supply NEX1.. will provide the power and signalling function for intrinsically safe sensors at protection level EEx ia. When the PNPinput is activated or INAMUR > 2mA, the red will light up and the output will be activated. When the inputs are passive the shows green. For the "Z"versions the dropin and dropout time delays can be adjusted by 2 potentiometers. For the types NEX1..N, the NAMUR input is replaced by an NPN input. (Attention: This versions are not UL listed!) Maintenance: The power supply does not require any special maintenance. Safety Instructions: When installing and operating with the NEX1 power supply, it is necessary to take into consideration the Matrix Elektronik AG (Manufacturer) Tippkemper Matrix GmbH Kirchweg 24 CH5420 Ehrendingen Meegener Str. 43 D51491 Overath Tel.:+41 56 2040020 Fax 29 Tel.:+49 2206 95660 Fax 19 relevant EU/US and other national regulations and the relevant guidelines ATEX 118a, ElexV, TRbF, TRD, UVV, EXRL, BetrSichV, UL508, UL913, Intrinsically Safe Apparatus and Associated Apparatus for use in Class I, II, III Division 1, Hazardous (Classified) Locations.. Standards met: EN 50014; EN 50020; EN 50081; EN 50082 Ex Protection 94/9/EG (ATEX 100a), UL 508, UL 913 Machine Directive: 98/37/EG Low Voltage Directive: 73/23/EWG, 93/68/EWG EMC: 89/336/EWG, 91/263/EWG, 92/31/EWG, 93/68/EWG RoHS directive: 2002/95/EG General Notes We reserve the right to modify our equipment. Our equipment is designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. Declaration of Conformity / Approvals: PTB 03 ATEX 2091 ULLISTED, ASSIGNED CONTROL No. 36HN / E210500 The conformity of the devices with the EC standards and directives and the ECtype examination certificate and the observation of the Quality Safety System ISO 9001 with the ATEX module "Production", declares: Hans Bracher, Matrix Elektronik AG Nex1AC_250VAC_e9/FEB.21,2007/HB

ASSURIX Intrinsically Safe Power Supply NEX108..VAC II (2) G [EEx ia] IIC Operating Manual and Control Drawing No. OMNEX01a ISO 9001:2000 / ATEX Power Supply for 3wire and NAMUR EEx ia Sensors. Process Control Equipment for Hazardous locations. Type of protection: Intrinsically Safe [EEx ia] IIC Listed by Underwriter's Laboratories Inc. Assigned Control No. 36HN Int. Safe Connections Cl.I, II,III Division 1, Applicable Gp.AG EU Certification of Conformity PTB 03 ATEX 2091 with Relay or Electronic. also available with adjustable delay function. Types NEX108R...VAC NEX108E...VAC NEX108RZ...VAC NEX108EZ...VAC Specifications Supply Voltage NEX108.24VAC 24VAC / 100mA (5060Hz) (Vm=250VAC) NEX108.115VAC 115 VAC / 40mA (5060Hz) (Vm=250VAC) NEX108.230VAC 230 VAC / 20mA (5060Hz) (Vm=250VAC) Connections 1 proximityswitch or 1 light barrier or 1 NAMURsensor Intrinsically safe output voltage for 3wire Sensors 8.2 VDC (Vo = 8.6 VDC) Intrinsically safe output voltage for NAMUR sensors 8.2 VDC (Vo = 8.6 VDC) Maximum output current Io = 111mA Max. usable output current 50mA Maximum output power Po = 660mW Max. capacitive load Co = 400nF Max. inductive load Lo = 2mH Switching frequency 5 Hz 1kHz 5Hz 10Hz Time delay 0.1 to 10sec. 0.1 to 10sec. Dropin and Dropout Delay adjustable adjustable Relay OptoCoupler Relay OptoCoupler Maximum AC load 250VAC/4A/100VA 250VAC/4A/100VA Cos ϕ >= 0,7 Cos ϕ> = 0,7 Maximum DC load 30VDC/4A 28VDC/50mA 30VDC/4A 28VDC/50mA 100W 1W 100W 1W Housing Synthetic (Polycarbonate, Polystyrole) Protection rating IP 20 at EN 60529 Ambient temperature range 0 C < TA < 60 C Mounting On rail EN 50022 or with 2 screws Options (not UL LISTED) with NPN input circuit, Type NEX108...N (without NAMUR input) or + max. 28VDC Collector Pin 1 + max. 28VDC R > 820Ω Connection to the Optocoupler: (Only for devices with Coupler) Dimensions: 0102 Emitter Pin 2 Signal 0V to VDC10% R > 820Ω Collector Emitter Pin 1 Pin 2 Signal 1V to VDC 62,5 60 36 75 4,8 37,5 35 50 110

Control Drawing for Hazardous Areas: Hazardous Area NonHazardous Area Zone 1, 2; Division 1 Control Ex ia Sensor Vmax >= Voc TA <= 60 C Imax >= Ioc Vmax = 8,6V Li + LCablel <= Lo Imax = 111mA Ci + CCable <= Co Ci max = 400nF Li max = 2mH Connections: NAMURSensors to NEX108R 3456 3456 NAMUR Emitter S blue E+ brown S+ brown E blue brown + black Sig blue 3456 3456 NAMUR Receiver Pin 10: do not connect any wire. NEX108.. [EEx ia] Power Supply Electrically Isolating and Circuit Max. Values Power Supply NEX1 Vo =8.6V Io = 111mA Po = 660mW Co = 400nF Lo = 2mH Power Input 24/115/230VAC Relay Contact or OptoCoupler 3wire Sensors to NEX108EZ 3456 3456 3456 Emitter + brown blue black 3456 3456 3456 Receiver Pin 11 / NDevices: NPNInput. 11 10 9 + NAMUR 8.2V PNP 0V Type NEX108R red green Connect proximity switch same way as light barrier receiver. 11 10 9 + NAMUR 8.2V PNP 0V Delay Type NEX108EZ red green Pin 11 / Other Devices: do not connect any wire. Connect proximity switch same way as light barrier receiver. PE N P 1 2 3 4 5 6 PE N P 1 2 3 4 5 6 Operating Manual / EC Declaration of Conformity: Mounting prescriptions: ExProtection The power supply must be installed out of the explosion risk area. The stated limit values must not be exceeded. The power supply must only be used with the voltage shown on the identification label. The connection for the intrinsically safe circuit is marked in blue. The power supply must only drive approved EEx ia intrinsically safe sensors. Function: The power supply NEX108.. will provide the power and signalling function for intrinsically safe sensors at protection level EEx ia. When the PNPinput is activated or INAMUR > 2mA, the red will light up and the output will be activated. When the inputs are passive the shows green. For the "Z"versions the dropin and dropout time delays can be adjusted by 2 potentiometers. For the types NEX108..N, the NAMUR input is replaced by an NPN input. (Attention: This versions are not UL listed!) Maintenance: The power supply does not require any special maintenance. Safety Instructions: When installing and operating with the NEX108 power supply, it is necessary to take into consideration the relevant EU/US and other national regulations and the relevant guidelines ATEX 118a, ElexV, TRbF, TRD, UVV, Matrix Elektronik AG (Manufacturer) Tippkemper Matrix GmbH Kirchweg 24 CH5422 Oberehrendingen Meegener Str. 43 D51491 Overath Tel.:+41 (0) 56/2220757 Fax 563 Tel.:+49 (0) 2206/95660 Fax 19 EXRL (BGR 104), BetrSichV (ATEX 137), UL508, UL913, Intrinsically Safe Apparatus and Associated Apparatus for use in Class I, II, III Division 1, Hazardous (Classified) Locations.. Standards met: EN 50014, EN 50020;EN 6100061/2,EN 6100063/4 Ex Protection 94/9/EG (ATEX 100a), UL 508, UL 913 Machine Directive: 98/37/EG Low Voltage Directive: 73/23/EWG, 93/68/EWG EMC: 89/336/EWG, 91/263/EWG, 92/31/EWG, 93/68/EWG General Notes We reserve the right to modify our equipment. Our equipment is designed such way, that it has the least possible adverse effect on the environment. It neither emit or contain any damaging or siliconized substances and use a minimum of energy and resources. No longer usable or irreparable units must be disposed of in accordance with local waste disposal regulations. Approvals: PTB 03 ATEX 2091 ULLISTED, ASSIGNED CONTROL No. 36HN / E210500 The conformity of the devices with the EC standards and directives and the ECtype examination certificate and the observation of the Quality Safety System ISO 9001 with the ATEX module "Production", declares: Hans Bracher, Matrix Elektronik AG Nex108AC_250VAC_e7/OCT.02,03/HB