Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Similar documents
Low Global Warming Refrigerants For Commercial Refrigeration Systems

Low GWP Refrigerants for Air Conditioning Applications

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

Sub-Critical Operation of the CO2 Expander/ Compressor

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

ZERO ZONE USER GUIDE TO THE 2017 EPA RETAIL FOOD REFRIGERATION REGULATIONS

A refrigeration system for supermarkets using natural refrigerant CO 2

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

R32 Compressor for Air conditioning and Refrigeration applications in China

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Wide-Boiling Refrigerant Mixtures - Technical and Commercial Challenges

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Purdue e-pubs. Purdue University

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

System Design, Commissioning, Operation

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Study of R161 Refrigerant for Residential Airconditioning

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Compressor Capacity Control: A New Direction

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Trends and Perspectives in Supermarket Refrigeration

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Compressor Capacity Control

Dynamic Simulation of Liquid Chillers

Chillers for High Ambient Conditions: What Technologies and Fluids?

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

Why Secondary-Coolant Systems for Supermarket Refrigeration?

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Natural Refrigerants.

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

THE INSTITUTE OF REFRIGERATION

System Using Exhaust Heat from Residential GHPs

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Commercial Refrigeration

Parilla Thermal Storage Project Case Study. May Page 1 of 11

PRACTICAL EXPERIENCE WITH AN ALTERNATIVE TO R-22 BASED ON R-32lR /R a. R E Low, B E Gilbert, T W Dekleva.

Guidance for Stationary Refrigeration & Air-Conditioning

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Thermodynamics II Chapter 5 Refrigeration

Comparison of the High Side vs

HFCs or the Old Refrigerants - what is the best Choice?

Commercial CO 2 Refrigeration Systems

Development of Large Refrigerant Compressors

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Thermodynamics I. Refrigeration and Heat Pump Cycles

Air-Cooled Heat Exchanger Performance for R410A

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Chapter 10. Refrigeration and Heat Pump Systems

From the Field to the Supermarket

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Performance Evaluation of an Economised Indirect Multi-Temperature Transport Refrigeration System

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Two-Step Capacity Modulation of a Single Cylinder Compressor

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

System Modeling of Gas Engine Driven Heat Pump

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Transcription:

Purdue University Purdue e-pubs nternational Refrigeration and Air Conditioning Conference School of Mechanical Engineering 1996 Modelling of an ntegrated Supermarket Refrigeration and Heating System Using Natural Refrigerants T. P. Castle EA Technology R. H. Green EA Technology D. Anderson Lancaster University Follow this and additional works at: http://docs.lib.purdue.edu/iracc Castle, T. P.; Green, R. H.; and Anderson, D., "Modelling of an ntegrated Supermarket Refrigeration and Heating System Using Natural Refrigerants" (1996). nternational Refrigeration and Air Conditioning Conference. Paper 35. http://docs.lib.purdue.edu/iracc/35 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

MODELLNG OF AN NTEGRATED SUPERMARKET REFRGERATON AND HEATNG SYSTEM USNG NATURAL REFRGERANTS Author(s): T.P.Castle, R.H.Green; EA Technology. United Kingdom: D.Anderson; Lancaster University, United Kingdom ABSTRACT This paper describes the development of a computer simulation model of an integrated supermarket refrigeration and heating system using natural refrigerants (namely ammonia and hydrocarbons). nitial results of the model's performance are presented, showing the influence of some of the operating parameters on system thermal efficiency. This will be validated using data collected from monitoring of a similar plant. The model and monitoring of a novel refrigeration plant are part of the UK's contribution to EA Annex 22 work program - Compression Systems with Natural Working Fluids (NWFs). NTRODUCTON The growing accept..mce of TEW (tot..'ll equivalent warming impact) as a me..'lsure of a systems contribution to global warming. puts greater emphasis on the energy efficiency associated with the system, rather than ',the direct contribution from the refrigerant. Natural refrigerants, such a<> ammonia, hydrocarbons and carbon dioxide. are widely seen as offering environmental benefit<; for retail refrigeration. The inherently high efficiency, and negligible direct global warming effect of natural refrigerants, in comparison to the widely used HFCs. will have a positive impact on the TEW rating of a refrigeration system. Also. many see tighter controls on refrigerant emissions and potential restrictions in supply of HFCs as an impetus to move towards natural refrigerants. However, many have problems assocbted with their use - ammonia for example is toxic, whilst hydrocarbons are highly flammable. Conventional supermarket refrigeration systems use direct cooling, with refrigerant circulated around the building to individual display case air coolers. The refrigerant leakage rate for this type of system is significantly greater than indirect systems, adversely effecting the TEW rating for refrigerants with a global warming effect n comparison to direct systems, the charge of primary refrigerant for an indirect system can be reduced by as much as 8-9%. Furthermore, the risk of leakage is greatly reduced for an indirect system, since the primary refrigerant is contained in a factory assembled and leak tested unit. Ammonia and hydrocarbons are only likely to be acceptable a<; refrigerants for indirect systems, where a limited charge can be contained safely. Recent changes to the British standards has widened the scope for 'natural' refrigerant usage; these are favoured more positively in Europe than in the USA. The safe and effective use of ammonia, coupled with a secondary system, represents a very sound solution with the potential for excellent energy efficiency in supermarkets. Until recently ammonia has not been used widely in supermarket refrigeration plant. However, recent developments, and considerable investment, have seen a number of full scale field trials by the majority of the main retailers, and the demand is steadily increasing in the UK. SUPERMARKET REFRGERATON MODEL A common approach to HV AC systems has been adapted to meet the chilling, freezing, store heating and cooling demand of a typical supermarket. A single phase secondary fluid is pumped around the shop floor ring mains acting as a heat sink and heat source for freezer, chiller and heat pump compressor packs. See figure L Any surplus heat from the secondary fluid is rejected to the 363

outdoor environment with a primary. n the interest of maintaining a system restricted to 'natural' refrigerants the refrigerated cabinet and heat pump compressor packs use hydrocarbon refrigerants. The number of display cases per compressor pack will be limited by the low charge restriction imposed by the new BS4434: 1995 standard (this may be as low as 1.5 kg for a sealed direct expansion system for supermarket use in some cases). Heat pump and cabinet refrigeration units use hydrocarbon refrigerants Ammonia chiller,-----------,!c=::x:::::::>l Se<."'ndary fluid / Figure 1 Schematic of integrated refrigeration and store heating system for a supermarket The benefit of this system is that a heat pump can be used to upgrade the heat rejected into the secondary fluid to provide heating for the store, reducing the refrigeration load of the ammonia chillers. Also the pumping requirements of the coolant fluid is reduced by circulating the coolant fluid at temperatures greater than the freezer units. The coolant fluid has to have sufficiently low viscosity at the required operating conditions (viscosity increases dramatically at the operating temperatures of freezers) not to need a huge input of pump power to drive it around the system. The choice of secondary fluid depends on the minimum temperature expected at the outlet of the evaporators. Below 5 C propylene glycol is used with the minimum concentration selected to avoid the adverse effect-> on physical properties viscosity and specific heat. Above 5 C water is chosen. The overall energy efficiency of the system includes the pumping requirement of the secondary fluid. An approximate figure for the model pumping power is derived by multiplying the monitored store design figure, by scalar values of the variables which influence the pressure drop of the secondary fluid. Refrigeration units and heat pumps The petformance of the, refrigeration units and heat pumps are predicted using manufacturer's data. Performance data is not available for the high efficiency scroll compressors using hydrocarbons. This was generated from isentropic and volumetric efficiencies obtained from R22 data. For comparison purposes, the range of refrigerants that can be selected for use in the scroll compressors are R22, R44a (the refrigerant used in the monitored refrigeration plant), propane and CARE 5 (a HC blend). 364

The model can co}:!e with up to three temperature levels in the display cases. A different refrigerant can be used for the refrigeration units if one refrigerant is more energy efficient than another at a particular temperature lift. There is also the option to cool the high temperature cases directly with the secondary fluid. f the temperature lift between the evaporator and condenser of the high temperature (HT) refrigeration unit is too small to perfonn well, then the secondary fluid should provide the cooling directly, saving energy from not using HT compressor sets. Condenser and evaporator coolant heat exchangers n most cases there will be a point of minimum temperature difference (pinch), between the secondary fluid and the refrigerant temperature profiles in the evaporators and condensers. The pinch temperature of the ammonia evaporator, D. TpTE, occurs between the secondary fluid outlet temperature, and the ammonia inlet temperature. The display case refrigeration condenser pinch temperature, D.TPTC occurs between the secondary fluid outlet temperature, and the refrigerant condensing temperature. To simulate the heat transfer process correctly the refrigerant and coolant temperature profiles must never cross: that is D.TPTC and D.TpTE are always positive. The method uses D.TPTC D.TPTE, and the temperature rise setting across the HC refrigeration condenser to define the evaporating and co~densing temperatures from the secondary fluid supply temperature. The full range of input data is as follows:. Refrigerant performance data for the chillers and refrigeration units, and the secondary fluid thennophysical data 2. Secondary fluid outlet temperature from the s. velocity of fluid. and temperature 3. rise across the Refrigeration condenser. specifications for pinch point values. subcooling in the condensers, and superheating in the evaporators. 4. 5. Refrigerant choice, duty, and evaporation temperatures of the refrigeration unit<> Condensing temperature of PRELMNARY RESULTS Examples of the effect on system efficiency of changes in secondary fluid operating temperature are shown in figures 2 and 3. These both show the system at its simplest, with one refrigeration temperature and no heat pump. Figure 2 shows a refrigeration temperature of -3"C (typical of frozen produce) whilst figure 3 shows -lo"c (typical of chilled produce). n general the power drawn by the refrigeration units installed in the display cabinets (hydrocarbon scroll compressors) increases with increasing secondary fluid temperature (due to the increasing condensing temperature), whilst the power drawn by the decreases with secondary fluid temperature (due to the increased evaporating temperature). Thus, there tends to be one distinct secondary fluid temperature which optimises system efficiency for a given set of chilled and frozen cabinet control temperatures, duties, and ambient temperature. n figure 3, there is a discontinuity in the total power consumption at -O"C second,:try fluid temperature, representing the secondary fluid chilling the HT cabinets directly. At a chiller condensing temperature of 45"C the overall power consumption is slightly in favour of using the secondary fluid to provide the cooling directly. whereas at 35"C it is the only solution. to avoid a significant energy penalty. Although not shown, one would also expect a discontinuity for the low temperature graph at -3"C secondary fluid temperature, with the chiller evaporating at approximately ~35"C. gnoring the pumping power of the secondary fluid at -3 C, the power consumption of the chiller (164kW@ -35 C evaporation, 35"C condensation) alone, is greater than the minimum overall power consumption using refrigeration units for the low temperature duty. Note that there is a minimum temperature lift for satisfactory operation of both the chiller and refrigeration units. As a result, above approximately l5 C secondary fluid temperature, the 365

evaporating temperature of the chiller remains fixed at 1 C. whilst the chiller duty and power increase. Also, at less than -1 C and -5 C coolant temperatures. the condensing temperature of the LT and HT refrigeration units remains fixed at ooc and 5 C respectively. Most supennarkets will operate both low temperature (L T) and high temperature (HT) cabinets. The effect on system efficiency with change in secondary fluid temperature and split in duties between LT and HT refrigeration units operating at temperature levels -3 C and -1 C is shown in figure 4 and 5. Figure 4 shows the power consumption for a typical supermarket duty ratio of 1 L T : 2 HT. Using the secondary fluid directly for the HT refrigeration is slightly more efficient than the best case using HT scroll compressor units, when the chiller condenses at 35 C. However, condensing at 45 C, the total power consumption is less using HT scroll compressor units. Figure 5 shows the power of the secondary fluid pump, chiller and refrigeration units for the most efficient secondary fluid temperature. with the chiller condensing at 35 C. for different LT:HT duty ratios. For both the 1:5 and 1:2 LT:HT duty ratios. the best performance is obtained with direct cooling of the HT cabinets using the secondary fluid - hence the relatively low power consumption from the hydrocarbon refrigeration units (low temperature only). At the 1:1 ratio. however, the optimum performance is achieved using the hydrocarbon refrigeration units for both the LT and HT cabinets - hence the larger power input to these units. nstead of using the to reject heat to ambient it is possible to raise the condensing temperature of the hydrocarbon refrigeration units and reject heat directly or through a separate water circuit. Using a water circuit with a dry. forced air cooled heat exchanger (of a similar size to the ammonia condenser), the condensing temper:uure of the rethgerntion units is approximately 42 C for the same air temperature profile (compared to the 35 C for the ammonia plant). n all cases, (even ignoring the extra pumping power of the water heat rejection loop) the raised condensing temperature means that the power consumption when just using the hydrocarbon refrigeration units is always worse than the best case when using the ammonia plant as well. CONCLUSON A computer simulation model of an integrated supermarket refrigeration and heating system has been designed to assess the performance of 'natural' refrigerants. ammonia and hydrocarbons against a conventional HFC system. The results indicate that the use of HT refrigeration units instead of secondary coolant directly chilling is advantageous at a high ambient temperature and high LT:HT duty ratio only. The advantage is likely to incre..1se at a lower ambient temperature once the store he.."lting requirements and the use of heat pumps are included. The model is still under development at present, and is in the process of being validated with data collected from the monitored pl.a.nt. t is hoped that this approach will result in an environmentally sound solution to the problem of supennarket refrigeration at minimum energy cost. 366

2 18 ~ 16 <:: 14 'li 12 f iil 1 8 Ui 6 ~ 4 "- 2 -i----- ---. ~..------:. r---,-j~[ -l--.l T------,J,v-- ----~- ~~y ~ ~------~ -~-i.. -1-5 5 1 15 2 Secondoryjfluid temperature from ammonia chiller "C =ndensing @35 C -o----- HC scroll compressor power CLD for 2kW duty -3 C - - Total power consumption @35oc chiller condensing -------<>------ Total power consumption @45"C chiller condensing condensing @45 C Figure 2 nfluence on power consumption with change in secondary fluid temperature and ammonia chiller temperature for freezer cabinets 2 s 18 "7 16 14 1l 12 1,... r----._ ----. ;>---- "-----. ~ ----; ---------- ----------- ------------ ~ :~,s--r ~t---l 1 F---1. l ~~ t t=rtj ~~ f=j ' -1-5, 5 1 15 2 Secondarylfluid temperature from ammonia chiller "C condensing @35 C ---o--- HC scroll compressor power CHD for 2kW duty @-1"C - -Total power consumption @35 C chiller condensing ------<>---- Total power consumption @45"C chiller condensing nrnrnnnin r-hill<>r Figure 3 nfluence on power consumption with change in secondary fluid temperature and ammonia chiller temperature for chiller cabinets 367

24 19 14 'E. a E c 8 9 ~.. N- ~ r----_ ---- -----------.. -- 1---. -~ ~~ '""-- ---- ------..... r------!:::::==~ -- - - ~EEFD n " 1-1 -5 5 1 15 2 Secondary fluid temperature from ammonia chiller c condensing @3s c ---o---- HC scroll compressor power CLT) for lookw duty @-3o c - - HC scroll compressor power (HT) for 2kW duty @-1 o c ----<>-------Total power consumption 3s c chiller condensing - - Total power consumption @4S c chiller condensing Figure 4 System performance with change in secondary tluid temperature for LT:HT duty ratio= 1:2 16 14 ~ 12 1 '5. E ill 8 c () OJ 6 3. 4 Secondary fluid pump Ammonia chiller condensing 3s c Refrigeration units using propane refrigerant (HC scroll compressor) 2 1:5 1:2 1 1 LT:HT refrigeration duty ratio - 3kW total duty Figure 5 Power consumption of secondary pump, chiller and refrigeration units for the most efficient operating condition for different LT:HT duty ratios 368