HI-LINE LV FAN CONVECTOR MODEL: 7-4.

Similar documents
SLIM-LINE RC FAN CONVECTOR.

HI-LINE SUPER RC FAN CONVECTOR MODELS: 25-18,

KICKSPACE 500, 600, V & 800

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

HI-LINE RC & HI-LINE RC Heater/Cooler Models: 7-4, 10-6, 15-10, Installation, Operating, Maintenance and After Sales Manual.

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

WHISPA III 5000, 7000 & Installation, Operating, Maintenance and After Sales Manual. Tested to UL & CSA Standards. Part Number: Issue 1

WHISPA III 5000 WM & 9000 WM. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual. Part Number: Issue 1

VD 3401 Chauffage central Installation, Operating, Maintenance and After Sales Manual

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

Signature, Sovereign, Sentry, Sentinel, Staccato Fan-Assisted Radiator. Installation & User Guide

Model: Touch-RS. 1 Touch-RS

Open Vented Condensing Boilers

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Flo~mate Mains Boost Pump Installation & Maintenance Instructions

Installation, Operation & Maintenance Instructions

100cm Chimney Hood GB IE

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

ART cm Island Curved Glass

UBGHFF60W 60cm Gas on Glass Gas Hob

CG60/ 70/ 80/ 90/ 100 SS/BK

Drying Cabinet Installation and Operating Manual

EVG Extractors. Manual for Installation, Use and Maintenance

QUALITY SPACE HEATERS

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

Thank you for choosing EnviroVent

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

User and maintenance manual

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Safety Warnings & Advice 3 Your Blast Vac Pro 4 Care & Cleaning 13 Using Your Vacuum 8 Troubleshooting 14 Guarantee 14 Technical Information 15

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M

Flomate Mains Boost Pump Installation & Maintenance Instructions

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

Installation, Operating and Servicing Instructions

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

200W Frostwatch Radiant Heater Operation Manual

Installation, Operation & Maintenance Instructions

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DEVIL CERAMIC SPACE HEATERS

Installation, Operating and Servicing Instructions

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

User Instruction Manual

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Assessment Schedule - TS.6

Electrisaver User and Installation Instructions

Heated Display. Instruction manual. Model: CW147 / CW148

USERS GUIDE 24, 30. For installation guide see reverse of book

INSTALLATION & TECHNICAL MANUAL

November This product has been reconfigured Please read these instructions

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

ISCG90SS _03 ISCG90SS

SP16. 08/50740/1 (UK) - Issue 1

Installation and Operating Manual Drying Cabinet

INSTALLATION GUIDE NZ AU GB IE A

LT4X AND LT6X Electric Slot Toasters

The Professional s Choice

CENTRIFUGAL PUMPS OPERATING INSTRUCTIONS

HOTLINE:

INSTALLATION & USER INSTRUCTIONS

Installation, Operating and Servicing Instructions

INSTALLATION & TECHNICAL MANUAL

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

INSTANTANEOUS ELECTRIC SHOWER

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Installation, Operating and Servicing Instructions

instructions OIL FILLED RADIATOR V V and V551225

INSTALLATION & USER INSTRUCTIONS

PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR UK-PR ISS-B

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Spiral Dough Mixer. Instruction manual. Model: CP821

E25 CONVECTION OVEN E25MS CONVECTION OVEN SERVICE MANUAL

GB User and maintenance manual

USERS GUIDE. LOGIC+ Combi 24, 30, 35

User's Instructions. Alpha CB50

GB24 & GB30. User Manual

Surface Warm Ceiling Heaters

IMPORTANT: RETAIN FOR FUTURE REFERENCE

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - US10 EPU - US15

ECOLEC PANEL HEATERS GENERAL NOTES.

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

Installation and Maintenance

CTE9. Extractor. Installation, use and maintenance.

Imperial Electric Fires

Xpelair Simply Silent TM Contour Fan

EZT90BL Extractor. Installation, Use and Maintenance.

SURFACE WARM CEILING HEATERS

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

Assembly and Operating

Your Blast Vac Pro. Your Blast Vac Pro

Transcription:

HI-LINE LV FAN CONVECTOR MODEL: 7-4. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL Product Serial Number: Please leave this manual with the end user. Part Number: 1370058 heatingthroughinnovation.

Contents 1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 Water Connections 04 8.0 Electrical Connection 05 9.0 Commissioning Procedure 05 10.0 Technical Data 06 11.0 Operating Instructions 06 12.0 Troubleshooting 06 13.0 Maintenance 07

HI-LINE LV Fan Convector 03 1.0 General Information l This HI-LINE LV fan convector is designed for wall-mounted installation with a maximum installation height of 2.13m to the underside of the unit and a minimum clearance between the top of the unit and the ceiling of 50mm. l The minimum installation height to the underside of the unit is 1.8m. l The minimum side clearance is 100mm. l The HI-LINE LV should only be used on closed circulation, two pipe, pump assisted central heating systems. l Before proceeding with the installation, the heating system design must be considered and the unit correctly sized to meet the heat loss requirements of the room at normal fan speed. l This unit is supplied with a fan speed selector switch giving two fan speed options and off. l This unit is fitted with a 12V transformer that enables the unit to be fitted in a bathroom. The unit must be positioned in accordance with local or national wiring regulations. l This HI-LINE LV unit can be controlled by the addition of a remote room thermostat. In bathroom installations this must be connected to the low voltage circuit, and positioned in accordance with local or national wiring regulations. l This unit should not be installed in locations with ceiling heights greater than 3m. l This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. l Children should be supervised to ensure that they do not play with the appliance. 1.0 2.0 3.0 4.0 2.0 Heating System Design This fan convector must be fitted on a two pipe, pumped circulation heating system. For optimum fan convector heating performance the system must be capable of providing sufficient hot water through the heat exchanger. This means that: 1. The minimum pipe size from boiler to fan convector must be at least 15mm. 2. This unit is not suitable for use on microbore pipework. 3. Where the unit is fitted on to a system with other emitters a separate circuit for the fan convector should be considered to provide adequate water flow. 4. The system water must be above 43 C for heating mode. 5. This unit is NOT suitable for one-pipe systems. 6. Optimum performance will require effective balancing of the whole system. 7. This unit should NOT be used to replace a radiator in an existing system unless an adequate flow of water can be guaranteed. 3.0 Unit Selection/Sizing Heat output performance is given in the Technical Data section of this manual. This unit has two fan speed options, however, it is important to size the unit to match the calculated heat loss requirements of the room with the unit operating on the low fan speed. The higher fan speed can then be used for more rapid heating from cold in extreme conditions. 4.0 Location l This HI-LINE LV unit may be fitted to any convenient wall at a height from floor level that suits the application, providing an unimpeded flow of warm air into the area to be heated. l The maximum distance from the underside of the unit to floor level is 2.13m. l The minimum installation height to the underside of the unit is 1.8m. l This unit should not be installed in locations with ceiling heights greater than 3m. l The unit should be mounted on a flat wall, and stud or partition walls should be avoided to minimize the possibility of noise transmission. l This unit may be fitted in zone 2 or the outside zones of a bathroom, in accordance with local or national wiring regulations (see fig. 1). OUTSIDE ZONES Zone 1 Zone 2 3m Fig. 1 2.25m 0.6m Zone 0 0.6m Zone 2

04 HI-LINE LV Fan Convector 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. HI-LINE LV unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Fixing kit (rubber mounts, cable gland and equipotential bond pipe clamp). 6. Transformer. 6.0 Fixing l Using the fixing dimensions below (see fig. 2), mark the fixing hole positions on the wall. l Drill and plug the wall for No. 8 x 40mm round head wood screws ensuring that the wall plugs are suitable for the wall type. 59 422 73 35 94 l Remove the backing from the self-adhesive washers and place on screws with adhesive side towards the point. 277 49 l Tighten the screws into the wall leaving about 9mm projecting. l Press adhesive washers to the wall. Remove the outer casing as follows: l Remove the 2 screws from the underside of the unit (see fig. 2). l Lift off the outer case. l Fit chassis on to mounting screws and tighten. Note: The guard at the left of the heat exchanger must be removed to access the mounting screws. Guards must be replaced before outer cover is fitted. Fig. 2 Before proceeding with pipework connections check that the unit is level. If the right hand end is lower than the left then the ability to vent the unit may be restricted. When water connections and electrical connections have been completed and the unit has been vented, fit the outer cover and secure with fixing screws. 554 7.0 Water Connections l Connect unit to system flow and return pipes using the two 15mm isolating valves (see fig. 3). l Ensure system is flushed in accordance with recognised best practice and a suitable inhibitor is added to the system as necessary. l Open valves fully, check pipe connections for leaks and vent the heat exchanger - see Commissioning Procedure. Cable Entry 79 96 42 50 min to ceiling 56 100 min each side Fig. 3 Case fixing screw positions 202 247 170

HI-LINE LV Fan Convector 05 8.0 Electrical Connection WARNING: The electrical installation must comply with local or national wiring regulations. l This unit is supplied with a 2m long mains cord. l A fused electrical spur with a maximum 3A fuse and a switch having 3mm separation on all poles must be provided in an easily accessible position. The fused spur must not be positioned in a bathroom or other similar high humidity installations. l For bathroom installations this unit must be connected to an equipotential bond using the pipe clamp provided in the accessories pack. Attach clamp to 15mm flow or return pipework inside the unit and attach earth conductor. Room Thermostat - if a remote room thermostat is required to control the fan convector, remove the link between T1 and T2 on the terminal block and connect a suitable bimetallic thermostat, capable of operating at low voltages, across these two terminals. The thermostat cable entry is through the hole in the chassis. A cable gland must be used. Transformer 0V Mains Supply 240V bl 5.0 12V br br 12V 0V T1 T2 6.0 br Colour Code bl = Blue br = Brown r = Red bl br br LOW LIMIT THERMOSTAT 7.0 y = Yellow MOTOR r y SWITCH 8.0 Fig. 4 Wiring diagram 9.0 9.0 Commissioning Procedure l Fill and vent the system. l Open both valves fully and check for leaks at pipe connections. l Refit the outer case and secure using the 2 fixing screws. l Switch on electrical supply. l Check the operation of the unit by following the operating instructions. l When installation and commissioning are complete, hand over instruction manual to end-user.

06 HI-LINE LV Fan Convector 10.0 Technical Data Heating Performance Data Model 7-4 Fan Speed Normal Boost Temperature Difference ( C) Heat Output (watts) Heat Output (Btu/h) 20 30 40 50 60 20 30 40 50 60 352 541 734 930 1128 1201 1846 2504 3173 3849 645 991 1344 1702 2065 2201 3381 4586 5807 7046 Heat outputs tested in accordance with BS 4856 Part 1. Flow rate 340 ltr/h (75 gal/h). Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply by 1.06. 227 ltr/h (50 gal/h) multiply by 0.96. 113 ltr/h (25 gal/h) multiply by 0.85. Noise Levels Fan Speed Sound Pressures at 2.5m (dba) Normal 16.6 Boost 32.5 Noise levels tested in accordance with EN 23741. Approximate Hydraulic Resistance through Fan Convectors Litres/h 455 340 227 113 mm wg 1084 798 350 134 kpa 9.4 7.7 3.5 1.4 Weight, Water Content and Motor Power Motor Power (W) Water Content (l) Unpacked Weight (kg) 30 0.3 7.4 Test Pressure 20bar (2MPa) Maximum Working Pressure 10bar (IMPa) Water connections 15mm Electrical supply to transformer 230V - 50Hz 11.0 Operating Instructions The HI-LINE LV is fitted with a fan speed and off selector switch. Ensure that the electrical supply is switched on. Heating will only be provided when the central heating boiler is on, the pump is running and the system water temperature is greater than 43 C. Ensure boiler is on, and set timer, boiler controls and room thermostats as necessary. Turn remote room thermostat (if fitted) to a high setting. Set fan speed control to position I. The unit will now run on low fan speed. The low speed setting is recommended for normal operation with the high speed for boost heating (position II) when required. Low Limit Operation A low limit thermostat fitted to the HI-LINE LV will ensure that the fan stops after the heating system is switched off and the water flow stops. If left in an operating position the unit will automatically restart when the heating system is reheated. Off Position Set the fan speed selector switch to the off (O) position. 12.0 Troubleshooting Once installed this fan convector becomes an integral part of a complete heating system that will generally include a boiler, pump, other emitters such as radiators and fan convectors, and a number of heating controls, dependent on system complexity. An apparent problem with this unit may be the result of system controls being incorrectly set and can be solved easily without calling out your installer or MYSON Service. Before calling your installer or MYSON Service, please carry out the checks listed opposite. Note: If you call out MYSON Service to a fault detailed opposite, or to repair a fault caused by incorrect use, a call out charge will be made.

HI-LINE LV Fan Convector 07 12.0 Troubleshooting (continued...) Problem Central heating mode - No fan Possible Causes Unit switched off Room thermostat not calling for heat Unit not switched on at fused spur Fuse blown at fused spur Unit isolating valves shut Water temperature reaching fan convector below 32 C Remedy Turn on Turn up room thermostat Switch on at spur Replace fuse Open valves Check boiler - Programmer ON Boiler ON and set to high with central heating pump running Note: Operation of fan can be checked by switching to F1, F2, F3 Heating Mode - Poor heating performance and/or unit cycles on low limit thermostat Low water temperature to unit Poor water flow Turn up boiler thermostat Vent air from heating system If the fan convector is still faulty after checking the above, call your installer or MYSON Service. Common Installation Faults For optimum performance, this unit must be correctly sized to match the heat loss requirements of the space it is required to Problem Poor heating performance Heating Mode - Poor heating performance and/or unit cycles on low limit thermostat heat, and the heating system must be correctly designed to provide adequate flow of hot water to the unit (refer to section 2). If the recommendations in section 2 are not followed, problems may arise as detailed below. Possible Causes Unit incorrectly sized for heat loss of room Boiler thermostat set too low Lack of flow to fan convector Pump set on low setting Isolating valves not fully open System incorrectly balanced with unit starved of hot water flow 10.0 Pipe sizing to unit too small 13.0 Maintenance Before undertaking any maintenance activity isolate the electrical supply. Maintenance should be restricted to occasional removal of dust and lint around the unit. The outer surface may be wiped over with warm water and mild detergent taking care to avoid water entering the grille areas. 11.0 12.0 13.0

MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk Serial Number Location: Lower/inner chassis position facing wall After Sales Service: MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.convectors@myson.co.uk Spare parts and technical help on all Convector products is available from MYSON Service. heatingthroughinnovation.