DuroSite TM LED High Bay. for Industrial & Commercial Applications.

Similar documents
DuroSite Series LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

DuroSite LED End-to-End Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

DuroSite LED RTO Area Light - UL / CSA. for Indoor and Outdoor Industrial Applications #

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Dialight. DuroSite LED Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

DuroSite LED End-to-End Linear Fixture - CE. for Indoor and Outdoor Industrial Applications

Essentials Series 4.0

Essentials Series 4.0

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Catalog Number. Notes

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

FPLHB - Fidelux Premier Linear Highbay

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

DIMMING 0-10V Continuous

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

LHBXD LED Linear High Bay

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Parking Garage. Lighting & Control Solutions SLGUS.COM

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Evolve LED Garage Light

Project Name. Date. Cat. Number. Type

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

Applications. Standard Materials

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

S R 8 Circular LED Engine Product Specification

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Dimensions (111mm) (111mm) 3 (76mm)

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Catalog Number. Notes. Type

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Project Name. Date. Cat. Number. Type

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

SECTION INTERIOR LIGHTING

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

TERRALUX RETROFIT LED LIGHTING

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

PRODUCT DATA SHEET LIGHTING PRODUCTS

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Alliance 4 - ALI4 LED 4 Linear High Bay

VESICA LINEAR SUSPENDED VES L

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Catalog Number. Notes. Type. IBL Series Lumens Distribution Lens Voltage Color temperature

Product Specifications

New LED Product Offerings

Who is Iconic LED? Page 2. Phone:(337)

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

DHL-LP-LED Low Profile LED Linear High/Low Bay

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

SenScape Luminaires Ideal for Covered Parking, Canopy and Low Bay Applications

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Welcome. Page 2. Iconic LED, LLC 1806 W Pinhook Rd. Lafayette, LA Main (337)

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

ARCHWAY TM PASSAGE TM

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

LED FIXTURE CATALOG. Shining light into the future

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Product Specifications MaxLumen MRI LED Diffused Lighting

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

LED LUMINAIRE SERIES LED Luminaire Series Improves Your Illumination Systems

110 lm w STANDARD SERIES


L305. tambient LED. for single workstations. All-in-one task/ambient luminaire, slim profile outrigger design for open office workstations with VDTs

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

USER MANUAL INSTALLATION GUIDE FOR: 2X2: MLFP22DS4035 MLFP22DS4041 MLFP22DS4050

Rating. Class I Div II

LED RETROFIT SOLUTIONS

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

LED HIGH BAY LINEAR HL SERIES

Vaya Linear LP, White & Mono

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Product Specifications Dialog Room Controller* (*patent pending)

Transcription:

DuroSite TM LED High Bay for Industrial & Commercial Applications 1

DuroSite TM LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours Up to 79 lm/ Significant energy savings Instant on/off Maintenance free Mercury free Superior light quality Dark Sky Compliant No heat or UV Simple installation Universal input: (100-277VAC), 50/60Hz or (347-480VAC), 50/60Hz Resistant to shock and vibration Temperature compensation technology for long life Copper free aluminum Typical Applications Warehouse Manufacturing Cold Storage Canopy Gymnasium Tunnels G.S. Dunn Limited Dry Mustard Millers Rockline Industries Supplier of Private Label Wet Wipes Frontline International Cooking Oil Management Solution Vie the full case studies at: G.S. Dunn Limited - /nes/details/gsdunn_case_study Rockline Industries - /nes/details/rockline_case_study Frontline international - /nes/details/frontline_case_study 2

Application: Dialight s Durosite LED High Bay fixture as designed specifically to replace conventional lighting in a ide variety of industrial applications; both indoor and outdoor. Its lo profile light eight design and versatile mounting options make it ideal for many applications such as arehouse, garage, aisle, cold storage, bridge, tunnel and general area lighting. All of Dialight s long life LED luminaires are designed to meet the most demanding specification criteria hile offering maximum energy savings, reduced maintenance costs, and a superior quality of light. (6) 1/4-20 SELF TAPPING SCREW HOLE 1.88 [47.75] Ordering Info: Part Number 6.88 [174.75] 1.95 [49.53] 3.00 [76.20] 5/16-18.75 THREADED (2) DuroSite TM LED High Bay Fixture 10 [3.05m] cord Patent Pending Dimensions in Inches [mm] Certifications Lens Optical Pattern UL-1598A UL-1598 IP-66, NEMA - 4 CSA 22.2 #250 Dry Locations CSA 22.2 #250 Clear Diffused Circular Oval Marine Wet Locations (Acrylic Lens) (Polycarbonate Lens) 2 Mechanical Information: Fixture Weight: 17 lbs (7.7 kg) Mounting: (1) 3/4 NPT or (2) 5/16-18 x.75 UNC Electrical specifications: Operating Voltage 1 : 100-277VAC, 50/60 Hz or 347-480VAC, 50/60 Hz Total System 150W Poer Consumption: Operating Temp: -40 F to +149 F (-40 C to +65 C) Harmonics: IEC 6100-3-2 Surge / Lightning 1 kv line to line Protection: 2 kv line to ground THD: <5% (120VAC) <10% (230/240VAC) <12% (277VAC) <15% (347-480VAC) Poer Factor: > 0.9 (100-277VAC) > 0.95 (347-480VAC) Construction: Body: Poder Coated Aluminum Lens: Acrylic (UL1598 Dry Location versions) Polycarbonate (UL1598A versions) Photometric Information: CRI (typ): 70 CCT (typ): 6000K (cool hite) Initial Fixture Lumens Typical (±10%) 3 Lumens Per Watt HB1C4N 11,672 78 HB6C4M 11,548 77 HB5C4M 10,862 72 HB1C4J 10,818 72 HB5C4J 10,541 70 HB3C4L 8,107 54 HB2C4M 10,904 73 HB7C4M 10,857 72 HB2C4K 10,175 68 HB4C4L 8,173 51 1 Part numbers listed in the table above are 100-277VAC. For 347-480VAC version replace the 5th character ith a 5. E: HB1C4N (100-277VAC) becomes HB1C5N (347-480VAC). 2 Units meet IP-66 hen installed using conduit or an IP66 approved cable gland at the 3/4 NPT. Dialight offers IP-66 approved cable glands as part of accessories HBW2 and HBCG. 3 Initial fixture lumens based on temperatures up to 113 F (45 C) 3

Occupancy Sensor Version Application: Dialight offers a series of High Bay products ith an attached occupancy sensor. The occupancy sensor leverages the High Bay s instant-on and instant-off capability to increase energy savings and enhance ROI. Other industrial lighting sources such as HID fixtures do not offer instant-on capability. Information 1 : Weight: 19lbs (8.6kg) Patent Pending Sensor Mounting: Attached to the base of the neck using a semi-rigid flexible conduit Occupancy Sensor: Leviton OSFHU- C T W ( 1 2 0-3 4 7 V A C ) or C 4 W ( 4 8 0 V A C ) Sensor Timing: 30 seconds to 20 minutes Sensor Lens Options: Narro lens ith a hite trim ring Wide lens ith a blue trim ring Oval lens ith a black trim ring Operating Temperature 2 : -14 o F + 149 o F (-10 o C + 65 o C) Features and Benefits No additional electrical connections required for installation Flexible conduit permitting the positioning of the occupancy sensor for optimal coverage Interchangeable sensor lens for high bay, lo bay, or aisle applications Dimensions in Inches [mm] Ordering Info: Part Number Certifications UL-1598 CSA 22.2 #250 Dry Location (Acrylic Lens) 3 Lens Optical Pattern Clear Diffused Circular Oval Initial Fixture Lumens Typical (±10%) 4 Lumens Per Watt HB1C4T 11,672 78 HB6C4T 11,548 77 HB5C4T 10,862 72 HB1C4S 10,818 72 HB5C4S 10,541 70 HB3C4R 8,107 53 1 Mec hanical, Electrical and Photometric specifications are the same as page 3 except as noted. 2-40 o F + 149 o F (-40 o C + 65 o C) polycarbonate lens units (consult factory) 3 Units meet IP-66 hen installed using conduit or an IP66 approved cable gland at the 3/4 NPT. Dialight offers IP-66 approved cable glands as part of accessories HBW2 and HBCG. 4 Initial fixture lumens based on temperatures up to 113 F (45 C) 4

Variable Dimming Version: 0-10 VDC Application: Dialight offers a series of High Bay products ith ACTIVE Dimming. Dimming permits the user to select a specific light output and poer consumption to meet their requirements. The reduction in light output and poer consumption are approximately proportional. Reducing the light output by 50% ill reduce the poer consumption by 50%. LEDs are particularly ell suited for dimming as compared to other industrial light sources. Electrical Interfaces 1 : 8.00 (203,2) Patent Pending Variable Dimming Cable Poer Cable Dimming Cable Position Variable Dimming Control: Dimming Range: Features and Benefits To conductor cable Three conductor cable Side of the neck through a cable gland 0-10 VDC active 10 VDC = 100% light output 0 VDC = 15% light output 1/4-20 SELF - TAPPING SCREW HOLE (6) 5/16-18.75 THREADED HOLE (2) 10 plenum rated dimming control cable pre-installed Dimming cabling independent of fixture iring Multiple High Bays can be connected to the same dimmer Ordering Info: Part Number 10 (3.05m) DIMMIMG CABLE UL-1598 CSA 22.2 #250 Dry Locations (Acrylic Lens) Ø 16.0 (406) Certifications 10 (3.05m) POWER CORD 1.91 (48,6) 3.13 (79,4) Dimensions in Inches [mm] UL-1598A IP-66, NEMA - 4 CSA 22.2 #250 Marine Wet Locations (Polycarbonate Lens) 2 Lens Optical Pattern Initial Fixture Total Fixture Lumens Typical (±10%) 3 Poer Consumption Clear Diffused Circular Oval Min Max Min Max HB1C4Y 2,334 11,672 78 HB6C4Y 2,310 11,548 77 HB5C4Y 2,172 10,862 72 HB1C4 2,164 10,818 72 HB5C4 2,108 10,541 70 30 W 150 W HB3C4W 1,577 8,107 54 HB2C4Y 2,181 10,904 73 HB7C4Y 2,171 10,857 72 HB2C4 2,035 10,175 68 HB4C4W 1,523 8,173 54 1 Mechanical, Electrical and Photometric specifications are the same as page 3 except as noted. 2 Units meet IP-66 hen installed using conduit or an IP66 approved cable gland at the 3/4 NPT. Dialight offers IP-66 approved cable glands as part of accessories HBW2 and HBCG. 3 Initial fixture lumens based on temperatures up to 113 F (45 C) 5 May also be configured to operate in a single STEP Dimming configuration STEP Dimming Mode The variable dimming High Bays may also be configured to operate in a single STEP Dimming configuration. When the dimming control conductors are connected together, the light output ill be reduced to approximately 15% of the maximum light output. The total fixture poer consumption ill also be reduced to approximately 20% (30 W). Connecting the leads together can be accomplished ith a common all sitch. Lumens per Watt

Part Number Description Kit Includes UL-1598 UL-1598A No Part Number Pendant Mount (Conduit supplied by installer) Conduit supplied by installer HBW2 Sivel Bracket and Cable Gland Sivel Bracket Bracket to fixture hardare Cable Gland (1/2 ) Reducer (3/4 to 1/2 ) HBW3 Sivel Bracket Sivel Bracket Bracket to Fixture Hardare HBCU Ceiling Mount Sivel Hanger Cover 3" Conduit Nipple HBCG Cable Gland Cable Gland (1/2 ) Reducer (3/4 to 1/2 ) HBLP Loop and Plug Hanger Loop (GE LOOPM353) 125/480VAC Tist Lock Plug (Pass & Seymour S2348DF) HBHP Hook and Plug Hanger Hook (GE HOOKM353) 125/480VAC Tist Lock Plug (Pass & Seymour S2348DF) HBB1 Poer Box Pendant Mount 277VAC Pendant mount 277VAC (Lithonia PPH277U) HBB3 Poer Box Pendant Mount 480VAC Pendant mount 480VAC (Lithonia PPH480U) HBB2 Poer Box Ceiling Mount 277VAC Ceiling mount 277VAC (Lithonia TPH227U) HBB4 Poer Box Ceiling Mount 480VAC Ceiling mount 480VAC (Lithonia TPH480U) HBT2 Junction Box ith Transformer 347-480VAC to 240VAC NEMA Box ith Integrated Transformer HBLAC1 Acrylic Lens, Clear (Cut) Cut Clear Lens Lens Gasket HBLAD1 Acrylic Lens, Diffused (Cut) Cut Diffused Acrylic Lens Lens Gasket HBLPD1 Polycarbonate Lens, Diffused (Molded) Molded Diffused Acrylic Polycarbonate Lens Lens Gasket 6

Mounting Options HBW2 - Sivel Bracket and Cable Gland HBCU - Ceiling Mount CUSTOMER SUPPLIED 4" SQUARE BO AND CONDUIT SWIVEL MOUNT 3/4"3" RIGID CONDUIT 8.50 [215.90] 10.00 [254.00] HBCG - Cable Gland HBLP - Loop and Plug 10 [3.05m] cord 2.00 [50.80] CABLE GLAND 3.75 [95.25] 5.00 [127.00] 9.25 [234.95] 5.00 [127.00] 3.00 [76.20] Dimensions in Inches [mm] 7

Mounting Options HBHP - Hook and Plug HBB1 & HBB3 - Poer Box Pendant Mount 3.57 [90.68] 8.82 13.43 [341.12] 5.00 [127.00] 4.95 [125.73] 5.48 [139.19] HBB2 & HBB4 - Poer Box Ceiling Mount 4.95 [125.73] 5.48 [139.19] Dialight reserves the right to make changes at any time in order to supply the best product possible. The most current version of this document ill alays be available at: /Assets/Brochures_And_Catalogs/Illumination/MDEHB001.pdf MDEHB001_E 8