USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Similar documents
SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

2. General information Page Warnings Page Technical characteristics Page Installation Page Front panel Page 7

USE AND INSTALLATION HANDBOOK

USE AND INSTALLATION HANDBOOK

ST1. Mod. USE AND MAINTENANCE MANUAL

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Original operating instructions Safety switch with guard locking AC901S AC902S

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Swaging Machine Type H50-46ECO

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

GB User and maintenance manual

Instructions For Use ENG. LED Magnifier Lamp

User and maintenance manual

AUTOMATIC VACUUM UNIT

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

General safety precautions English

LHS PREMIUM LHS SYSTEM

General safety precautions English

General safety precautions English

General safety precautions English

CONTROL PANELS for 2 Q2P series ELECTRIC PUMPS

Table of Content LT 5165-UL

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

USERS MANUAL FOR GAS BOILERS

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Original instructions JSNY7 Magnetic switch

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

CTA15-2 warming drawer. operating and installation instructions

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

Instruction Manual. Electronic gas and smoke detector GRM

Original instructions Sense7-series Non-contact coded safety switch

Service package PDAD- -SP (en) Assembly instructions d [ ]

HSGM Heißschneide-Geräte

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

MODEL 7000 SUCTION UNIT

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Installer: (Name, address, telephone)

NXM2G Installation and Operating Manual

Stainless Steel Chimney Extractor

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

90cm Chimney Extractor

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

HR 601 C A AUS. ENGLISH Instructions for use Page 2

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

ISIS SAFETY SYSTEM Installation guide

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

MOD. 605 E. Made in Italy INSTRUCTION MANUAL

IMPORTANT SAFETY INFORMATION

Automatic Flux Processing Oven Model FEM

L / -014L / -015L

Mini. Level Control systems For Manual Sump Pumps up to 750W 1 or 2 Pump Systems

Whole Room Dryer WRD, WRD/110

Stainless Steel Chimney Extractor

KM300 Carbon Monoxide Detection System Installation Manual

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Drying Ovens for Fluxes Models F100 F200 - F400

Installation, Operation & Service Manual

INSTRUCTIONS NACHO WARMER MODELS: 1995 / 1995S

SCHMIDT LED Measured Value Display MD Instructions for Use

RE-PR3-E-27 3-Phase Panel Mount 27kW

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

INSTRUCTION AND MAINTENANCE MANUAL

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Heat press PF-150C Series

ISCG90SS _03 ISCG90SS

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Instructions for use

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

Premier External TD. Installation Manual INS352-3

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

INSTRUCTIONS AND WARRANTY

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. External Sounder & Strobe Unit

The guarantee on this appliance is valid for 12 months from the first day of installation.

PAC1500Xi PORTABLE APPLIANCE CHECKER

Door Release Power Supply

Transcription:

USER GUIDE DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

II

CONTENTS 1. SYMBOLS AND WARNINGS... 5 2. GENERAL INFORMATION... 6 3. WARNINGS... 7 4. GENERAL DESCRIPTION... 8 5. INSTALLATION... 9 6. CONTROL PANEL... 10 6.1 Luminous indicators and control commands... 10 6.2 General operation notes... 11 7. SETTINGS AND ADJUSTMENTS... 12 7.1 Current control protection... 12 7.2 Alternating operation mode... 13 7.3 Other functions... 15 8. STANDARD CIRCUIT DIAGRAMS... 16 8.1 DRENA 2 Single phase circuit diagram... 16 8.2 DRENA 2 Three phase circuit diagram... 17 9. STANDARD WIRING DIAGRAMS... 18 9.1 DRENA 2 Single phase wiring diagram... 18 9.2 DRENA 2 Three phase wiring diagram... 18 10. TROUBLESHOOTING... 19 11. GENERAL CONDITIONS... 21 11.1 Warranty... 21 11.2 Maintenance... 21 11.3 Disposal... 21 13. DECLARATION OF CONFORMITY... 22 III

IV

1. SYMBOLS AND WARNINGS This operation and maintenance manual uses the symbols outlined below to indicate risks that may arise in the event of failure to observe the instructions supplied. DANGER This symbol corresponds to an immediate risk of death or serious physical injury or material damage. When present, take great care to observe warnings and instructions. CAUTION This symbol corresponds to a possible risk of death or serious physical injury or material damage. Take care. WARNING Failure to observe the instructions in the presence of this symbol may lead to malfunctions and damage to equipment, with possible consequent injuries to the operator. Before performing any work on the electrical panel or system, shut off the electrical power supply. The electrical panel must be connected by a qualified electrician in observance of the relevant electrical standards. Before any other operation, ensure the installation is connected to an efficient earthing system. After making the electrical connection, check that all electrical panel settings are correct to avoid automatic start-up of the electric pump. 5

2. GENERAL INFORMATION This manual must always accompany the relevant equipment and be conserved in an accessible location for consultation by qualified technicians assigned for operation and maintenance of the system. The installer/user is strongly recommended to carefully read all instructions and information in this manual before using the product, in order to avoid damage or improper use of the unit, which would also render the warranty null and void. Before operating the equipment, carefully read the manual and follow all instructions herein. The information and instructions in this manual refer to the standard use of this product; in the event of special circumstances, functions or applications not described in this document, contact our service centre for assistance. If technical assistance or spare parts are required, when contacting the manufacturer always specify the identification code of the model and construction number as stated on the data plate. Our service centre is available for any requirement or clarification. The electrical equipment supplied must be installed indoors in a well-ventilated environment, within a temperature range of -5 to +40 C. N.B. the information provided in this manual is subject to modifications without notice. The manufacturer shall not be held liable for any damage caused in relation to the use of these instructions as they are to be considered guideline only. Note that failure to observe the instructions provided in this manual may cause physical injury or damage to objects. In any event all local and/or current legislation must be observed at all times. 6

3. WARNINGS On receipt of the goods, perform an inspection immediately to ensure that the equipment has not been damaged during transport. If defects or missing material are found, the client should promptly notify, and in any event within 5 days of receiving the goods, our retailer, or in the event of direct purchases, the Elentek service centre. The DRENA 2 electrical panel must be used exclusively for the purpose and function as specified in design. Any other application or use is to be considered improper and therefore hazardous. DANGER All DRENA 2 panel installation and maintenance operations must be performed by a specialised technician who is fully aware of the relevant current safety standards. No parts of the panel must be disassembled without the official authorisation of Elentek: any tampering with or modifications to the unit will render all terms of the warranty null and void. Always disconnect the unit from the power supply before maintenance or cleaning. If DRENA 2 is not used for prolonged periods, store the product in a clean and safe location protected against atmospheric agents and the potential risk of dropping/falling. DANGER CAUTION In the event of a fire in the place of installation or the surrounding area, avoid the use of water jets and use the appropriate extinguishing equipment and means (powder, foam, carbon dioxide). Install the equipment far from heat sources and in a dry and sheltered location in observance of the stated protection rating (IP). The installation of a safety device is recommended to protect the panel power line in compliance with current electrical standards. Elentek declines all liability in the event of the following: - Incorrect installation; - Use by personnel not adequately trained in the correct use of the panel; - Serious failure to perform scheduled maintenance; - Use of non-original spare parts or parts not specific to the model; - Unauthorised modifications or interventions; - Partial or total failure to observe instructions; 7

4. GENERAL DESCRIPTION Power supply 1 ~ 50/60Hz 230V±10% (DRENA 2-Single); Power supply 3 ~ 50/60Hz 400V±10% (DRENA 2-Three); Low voltage control circuits and inputs; G.MIN Normally open input for minimum level/pressure command; G/P1 and G/P2 normally open inputs for start-up command; T1 and T2 input for motor clicson; G/P ALARM normally open input for alarm activation 12Vdc 200mA; AUTOMATIC-0-MANUAL buttons (spring return); Motor switching module with 5-second delay; Internal selector for switching module shut-off; Internal selector for start-stop function on switching module; Green led: Power mains ON; 2 green leds: motors active; 2 green leds: automatic mode enabled; Red led: level alarm; 2 red leds: motor overload alarm; 2 red leds: motor clicson activation alarm; Settable electronic motor overload control; 5-second overcurrent protection trip; Protection of aux. circuits and utilities with fuses; Alarm output (COM-NO-NC resistive load - 5A / 250V); Door lock general disconnect switch; Provision for start-up capacitor (not included); Box in ABS, IP55; Ambient temperature: -5/+40 C; Relative humidity 50% at 40 C (condensate free). 8

5. INSTALLATION Ensure that the mains power supply specifications correspond to the voltage specified on the data plate of the electrical panel and motor connected, then make the earthing connection before all other connections. DRENA 2 Single 1~230V ± 10% 50/60Hz DRENA 2 Three 3~400V ± 10% 50/60Hz The power line must be protected by a residual current circuit breaker. Tighten the electrical cables on the relative terminals using a suitable tool correctly sized to avoid the risk of damage to the fixing screws. Take care if using an electric screwdriver. The DRENA 2 electrical panel is designed for wall-mounting using screws and plugs in the predrilled holes at the corners of the enclosure, or by means of brackets when present. 9

6. CONTROL PANEL 6.1 Luminous indicators and control commands The DRENA 2 electrical panel has been designed for adjustable protection of 2 motors, commanded by external contacts (such as floats or pressure switches) and integrated function for automatic switching and disable option. KEY TO LUMINOUS INDICATORS AND COMMANDS Green led: mains power ON Green led: electric pump operating Red leds: motor thermal cut-out trip Red led: level alarm Red led: motor temperature overload alarm (optional) Green led and button: automatic mode Motor stop or alarm reset button Manual mode button 10

6.2 General operation notes After connecting the panel to the electrical mains and with the door lock switch set to ON, the green led illuminates to indicate power on the panel. On initial activation, the panel starts up in Automatic mode (indicated by the green led on the AUT button). If the motor is enabled, this is indicated by the green led signalling the electric pump in operation. The buttons enable the following settings: : start-up of the motor in Automatic mode, activated via floats or pressure switches; : manual shutdown of motor and reset in event of motor thermal cut-out trip. : start-up of motor is manual mode by operator pressing and holding the button; N.B. Motor operation in automatic mode is commanded on closure of the G.MIN contact, designed to protect against dry running, to which a pressure switch or min. level float can be connected. If G.MIN is not used, a jumper should be wired in on the contact. 11

7. SETTINGS AND ADJUSTMENTS 7.1 Current control protection On the basis of the output of the motors to be controlled, and therefore the output of the electrical panel, the electronic board is fitted with one of the following types of controller: from 2A to 18A and 16A to 35A. On initial activation of the panel, the overload protection (or thermal cut-out) must be set according to the absorption of the electrical motors connected to the panel, using the trimmer MOTOR PROT 1 and MOTOR PROT 2. During this operation, the protection trip delay (of approx. 8 seconds) must be inhibited, by wiring in the jumper RIT.PROT.MOTOR1 and RIT.PROT. MOTOR2. After the motors have started, set the protection trimmer to the maximum setting (rotate clockwise) and, as described above, wire in the jumper RIT.PROT. MOTOR1 and RIT. PROT. MOTOR2. Slowly turn the trimmers MOTOR PROT 1 and MOTOR PROT 2 towards the minimum setting (rotate counter-clockwise) until the thermal cut-out trips and the motors are shut down. At this point, the value at which the motors stop must be increased by approx. 15% to obtain the setting value for the trimmer MOTOR PROT 1 and MOTOR PROT 2. After completing this setting, remove the jumper RIT.PROT. MOTOR1 and RIT.PROT. MOTOR2. N.B. The thermal cut-out time, and therefore the motor shutdown time is approx. 8 seconds, but this can also be inhibited by wiring in the jumper on RIT.PROT. MOTOR1 and RIT.PROT. MOTOR2. 12

7.2 Alternating operation mode The DRENA 2 panel can be used with an automatic switching module to change between motors on each activation, or with a direct on/off command. This operating mode is set by wiring in the jumper ALTERNATION. To activate automatic switching of the pumps set both ALTERNATION jumpers to ON. In this way on each call sent by the command G/P1 (float or pressure switch) motors 1 and 2 are alternated. In the event of a simultaneous call from the command connected on G/P2 both motors are activated. If direct control of the motors is required, set the ALTERNATION jumpers to OFF. This means that G/P1 directly and independently controls motor 1 and G/P2 directly and independently controls motor 2. 13

Practical example: 1 Stop float. 2 Alternation float. 3 Emergency float. 4 Alarm float. 14

7.3 Other functions The DRENA 2 panel also offers the option of an alarm signal in the event of low level/pressure. By wiring in the jumper EXC. ALARM, on opening of the input contact G.MIN, a luminous signal lights up on the front of the panel to indicate a level alarm, and the cumulative alarm relay is switched. Otherwise, when the jumper is removed, on opening of the contact G.MIN, the motors stops without any additional alarm signals. On closure of the input G/P ALARM the following occurs: - activation of the luminous signal on the front of the panel to indicate a level alarm; - switching of the cumulative alarm relay; - activation of the alarm output OUT 12Vdc (G.A.) As the DRENA 2 panel is designed for electric pumps in waste water applications, it can also be used with the alternation function with start-stop function on multi-contact pear-shaped float switches. This setting is obtained by wiring in the jumper FUNCTION START/STOP on the left side of the control terminal board. If the jumper is removed, the start-stop function on the pump control float switches is no longer active. N.B. In the event of malfunctions of one of the two motors, the defective model can be excluded from automatic mode by wiring in the respective jumper at the rear of the synoptic panel, located inside the box cover. When viewing the rear of the synoptic panel, the left-hand jumper controls operation of the 2nd motor, while the right-hand jumper controls operation of the 1st motor. 15

8. STANDARD CIRCUIT DIAGRAMS 8.1 DRENA 2 Single phase circuit diagram 16

8.2 DRENA 2 Three phase circuit diagram 17

9. STANDARD WIRING DIAGRAMS 9.1 DRENA 2 Single phase wiring diagram 9.2 DRENA 2 Three phase wiring diagram 18

10. TROUBLESHOOTING PROBLEM CHECKS / SOLUTIONS 1. The panel is powered up but does not start up in automatic mode Check that the green leds on the automatic mode buttons are lit; otherwise press the buttons. 2. The panel is set to automatic mode but the pumps do not start. Check that the float input G.MIN is jumpered if no minimum level float is used. Ensure correct operation of the start and stop floats. Check that the normally open inputs are closed. On the single phase model,. check that the 230V~ voltage is present on the motor 1 output terminals U1 and N1 and on the motor 2 output terminals U2 and N2 ; on the three-phase model check that the 400V~ voltage is present and that the contactor windings are powered on the motor 1 output terminals U1 and N1 and on the motor 2 output terminals U2 and N2. Ensure correct insertion of the alternation jumpers (see page 13). 3. On pump start-up, the panel thermal cut-out trips Check the nominal current of the pumps and set the trimmers (or potentiometers) indicated on the board by MOTOR PROT 1 and MOTOR PROT 2 with a current higher by approx. 15%. Check that the jumpers indicated on the board by PROT. DELAY MOTOR1 and PROT.DELAY MOTOR2" are not jumpered thereby delaying the thermal cut-out trip by approx. 8 seconds in the case of excessively high pump start-up currents. 4. The 12 Vdc voltage is not detected on the alarm output faston connectors Ensure that the normally open contact float closes in the event of a level alarm. Ensure correct operation of the alarm float. 5. The panel is always set to level alarm status. Ensure that the minimum level float wiring is correct (terminals in G.MIN ). 6. The panel is in motor temperature overload alarm status Check that jumpers are wired in on the motor clicson inputs T1 and "T2" if the pumps are not fitted with a thermal cut-out. 19

7. No led lights up on the control panel. Ensure that the FLAT connection with the board inside the panel is inserted correctly. Ensure that the door lock is set to ON. On the panel input, check that the voltages 230V~ or 400V~ are present between the mains input terminals L and N. 20

11. GENERAL CONDITIONS 11.1 Warranty The product warranty is subject to the general terms of sale of the company Elentek S.r.l. Acknowledgement of the warranty depends on the strict and proven observance of the operating instructions in this booklet and application of the correct mechanical, hydraulic and electro-technical practices. All products are covered by a warranty valid for 12 months, which covers all construction defects of our products and includes the replacement/repairs of defective parts. The warranty will not be deemed valid in the event of: - tampering with the panel (modifications without prior authorisation); - faults due to lack of or inadequate protection and/or connection errors; - faults caused by exceeding data plate specifications; - normal wear and tear; - failure by installation personnel to observe the specified operating procedures; - accidental causes, natural disasters of any kind, such as fires, flooding, water or lightning; The defective material must be delivered carriage paid to Elentek S.r.l., who reserves the right to final judgement of the cause of the said defects. The Warranty applies exclusively to restoring the original product characteristics and does not cover material damage or physical injury. 11.2 Maintenance DRENA 2 does not require routine maintenance provided that it is used within the operating limits and in observance of the instructions in this manual. Special maintenance or repairs must be performed exclusively by authorised service centres. In the event of repairs, only original spare parts must be used. The manufacturer declines all liability for material damage or injury to persons or animals caused by maintenance interventions performed by unauthorised personnel or using non-original materials. 11.3 Disposal In the event of disassembly and scrapping, strictly observe local legislation regarding pollution. Waste disposal according to material categories is recommended. 21

13. DECLARATION OF CONFORMITY ELENTEK Srl Unipersonale Via A. Meucci, 5/11 35028 Piove di Sacco (PD) ITALIA hereby declares, under its sole responsibility, that the machine: Trademark ELENTEK DRENA series complies with the provisions of the following EU directives and subsequent amendments: Machinery 2006/42/EC European Directive 2006/95/EC Electromagnetic Compatibility 2004/108/EC and subsequent amendments, in compliance with the following technical standards: EN 61439 EN 61000-3-2 EN 55014-1 EN 61000-3-3 Piove di Sacco, 01.04.2014 LEGAL REPRESENTATIVE Michele Borgato 22

NOTE 23

ELENTEK SRL SOCIETÀ UNIPERSONALE Via A. Meucci 5/11-35028 Piove di Sacco (PD) - ITALIA Tel. +39 049 9730367 - Fax +39 049 9731063 www.elentek.com - info@elentek.com P.IVA 04534630282 Cod. MQ 0002 UK Rev. 00 Em. 04.2014