Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Similar documents
Technical documentation DTR

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

Technical documentation DTR. Farmer HCF in EPP casing

Technical documentation

Technical documentation: S1 S2 S3 S4

Technical documentaton DTR. Farmer

Technical documentaton DTR. Farmer

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

PRICE LIST VALID FROM 1st October 2017

Reventon Group [Ltd.] 3B Montażowa Street, Bielsko-Biała, Poland VAT ID tel.

HEATING AND COOLING DEVICE AGC

1.1 VTS: number 1 in the world pillars of success

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON EL. PROTON EL Electric heating.

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON ECO. PROTON ECO Three-speed AC-motor

TERM-E ELECTRIC HEATING AND VENTILATION UNITS

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

Installation & Operating Manual ZM kW Universal Oil Heater. ZMH Ltd t/a Z M Heaters T (0)

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

Air curtain.

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

How to install and use your storage heater

USER S GUIDE UTE202NP SERIES NON PROGRAMMABLE ELECTRONIC THERMOSTAT

SAFETY AND OPERATING MANUAL

HEATING AND COOLING UNITS BRAVA

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON JET. PROTON JET Air Heater with with AirJet nozzle.

Air-Water heat pump Small GT

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

USERS MANUAL FOR GAS BOILERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

No. 1 in Europe New on offer air curtain GUARD

ErP OPERATIONS MANUAL FOR AIR HEATER PROTON AST. PROTON AST Air Heater with the anemostat

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

WHE 2.24 / WHE 2.24 FF

USER'S MANUAL PGE Single Package Rooftop

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

MANUAL FOR ASSEMBLY AND OPERATION OF ELECTRIC FLOW-THROUGH BOILER/MODULE WITH THREE STAGE ELECTRONIC CONTROL

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

TSL hand dryer. installation + maintenance

OIL COOLER INSTRUCTION HANDBOOK

OXeN. Ductless ventilation with heat recovery.

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Roof top SPACE RPC 450Z R407C M011

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

THE QUALITY BRAND IN FANS

THE QUALITY BRAND IN FANS

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

CNBOP-PIB Standard Fire Protection

No. 1 in Europe New on offer air curtain GUARD

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

P4000 Construction Heater

Installation and Operating Instructions. Models: T4-12LOW-9IS

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

Ozomax Ltd Ozone generators

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

OPERATING AND INSTALLATION MANUAL

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

50TM TFF COMBINATION HEATING/COOLING UNITS

Series VENTS VUT R WH ЕС

Specification / Type INTEGRA 400/100 INTEGRA 500/120 INTEGRA 800/200

MERIT SERIES Up Flow / Horizontal

50TM COMBINATION HEATING/COOLING UNITS

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

AQUATHERM LTD INSTALLATION AND OPERATION OF ELECTRIC BOILERS

LOW STATIC HYDRONIC DUCTED UNIT

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

The guarantee on this appliance is valid for 12 months from the first day of installation.

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

Mercury RV Water Heaters. Duoetto. HCE-10 Dual Voltage 12VDC/240VAC. P.O. Box 777, Leichhardt, NSW 2040

ST 53.1 User s manual

Drying Ovens Models F3 - F6 - F9

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

LHS PREMIUM LHS SYSTEM

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

technical data Fan coil unit FWB small duct unit

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

HOT TAP WATER EXCHANGER with solar pump-group ENSOL IT INSTALLATION AND OPERATION MANUAL WARRANTY CARD

DH-Direct Fired Poultry Farm Diesel Heater

Ceiling Mount Air Purification System

Installation Operation Maintenance

TTV 4500 / TTV 4500 HP / TTV 7000

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Oil Filled Radiator. Model: SH60010 (all colours) Help line: This product is only suitable for well insulated spaces or occasional use

DUCTLESS VENTILATION WITH HEAT RECOVERY. OXeN ductless ventilation unit

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Transcription:

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-S SERIES

PL TECHNICAL DOCUMENTATION Table of contents Heating coil: made of aluminum and copper. The temperature of the heating factor is C; maximum pressure, MPa; headers diameter ¾. Depending on the water heater model we offer, and heating coils.. INTRODUCTION. PRECAUTIONS. TRANSPORT. PACKAGE CONTENT. USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL DATA. CONSTRUCTION. DIMENSIONS. TECHNICAL DATA. ASSEMBLY. INSTALLATION INSTRUCTIONS. PRECAUTIONS & WARNINGS. CONTROLS. CONNECTION SCHEMES. TERMS OF WARRANTY. WARRANTY CARD. WARRANTY FORM. SERVICE FORM height: 9 mm (a) width: mm (b) depth: mm (c). INTRODUCTION HC -S, HC -S Thank you very much for purchasing Reventon Group device. We would like to congratulate you on excellent choice. height: 9 mm (a) width: 9 mm (b) depth: mm (c) Axial blowing fan: protective grid made of steel wire galvanized, metal blades. The motor has got the safety degree IP. Rate current,a-,a. -phase device, -stage fans. Models HC-S, HC-S, HC-S, HC-S have fans with diameter mm. Models HC-S and HC-S have fans with diameter mm. Rotating mounting bracket: made of steel, element for mounting the device on the wall or ceiling. Solid and durable construction, possible to assemble device in parallel on the angle. Possible rotation horizontally.. DIMENSIONS HC -S, HC -S, HC -S, HC -S c a. PRECAUTIONS The buyer and the user of the device should read carefully the following instructions and proceed to the content recommendations. Proceeding due to the following instruction guarantees the correct usage and safety. In case of any doubts please contact the producer. The producer reserves the rights to make changes to the technical documentation without previous notice. The producer is not responsible for the damages which occur due to improper installation, not keeping the device in repair or using the device out of line. The installation should. TECHNICAL DATA be carried out by the professional installers, who possess the qualifications to install these types of devices. The installers are responsible for making the TECHNICAL DATA Unit of installation as instructed in the technical data. Regulations and safety rules must measure be followed. During the installation, use, service and periodical inspections all CODE regulations and safety rules must be followed. In case of unserviceable please Nominal heating capacity plug out the device and contact with the authorized person or the producer. water 9/ C and inlet kw air temperature C [kw]. TRANSPORT During the acceptance of goods, it is needed to check the device to exclude any damages. During the transport, it is needed to use the proper equipment, it is necessary to carry the device by two people. In case of any damages please fill in the damage report in presence of the supplier. Heating power range Maximum airflow kw m³/h b HC-S HC-S HC-S HC-S HC-S HC-S WHHC-S WHHC-S WHHC-S WHHC-S WHHC-S WHHC-S -9 - - - - -,,,9,,,,, 9,9-,,,9,9-,,,,, stage stage stage 9 9 9 Maximum range of air stream m Number of rows pcs.. PACKAGE CONTENT Capacity of water dm³,,,,,9, Air temperature rise * C,,, 9, - Heater - Operation and maintenance manual and warranty card Maximum temperature of heating agent C. USE AND PRINCIPLE OF OPERATION Devices Reventon Group HC-S series are used to heat spaces such as: production halls, warehouses, commercial room, service spaces, garages, workshops, greenhouses, tents, shops, malls, shopping malls and churches. Air water heaters must be connected to central heating system. Application of modern technologies in Reventon Group devices guarantees high effectiveness and comfort of the consumption. Original colors of the devices match to every interior. The device is made very precisely and will work smoothly for many years. * The product has got the two years of warranty. Maximum operating pressure Rated current MPa A Power supply voltage V~Hz Motor speed rev stage /min stage stage Motor power W Casing: made of expanded polypropylene EPP, resistant, light and reliable. The material can carry considerable loads without deforming. It does not degrade under the influence of a lubricant, oil, crude oil and most of chemicals. It has an excellent sound insulation property, that is why it is used as casings, material is environmentally friendly and "green", i.e. % recyclable. Aesthetic design gives new nature to the device. Air stators: made of polypropylene PP. It is possible to adjust manually the air stators to achieve the needed direction of the air flow.,,,,,,,,,,,,,,,, / / / / / / 9 9 9 9 9 9 - / / / / / /,,, 9, Noise ** Casing Air stators Heating coil Axial blowing fan Rotating mounting bracket,,,, Motor IP Weight - stage stage stage,,,, Connection diameter kg. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL DATA. CONSTRUCTION stage stage stage db stage stage stage * Temperature rise according to parameters: water 9/ C and inlet air temperature C. ** The measurement at m from the unit

HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage 9/ / /,,9 9,,, 9,,,,9,,,,,,,9 9,,,,,,,,9,,, 9,,9,,,9,,,,,,,,9,, HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage / 9/ /,,9,,,9,,9,,,9,,,, 9,,, 9,,,,9,,,,,,,9,,9,,,,,,9,,,,9, HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage / / 9/,,,,, 9,9,,,,,9, 9,,, 9,,, 9,,,9,,9,,,,,,9,,,,,,,,,9,,,,,, HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage / / / 9,,,,,,,,,,,,,,9,,,,, 9,,,,9,,9,,,,,,,9,,,9,,,,,,,, HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage 9/ / /,,,9,,9,,,,,,,,,,9,,,,,,,,,,9,,,,,,9,,,9, 9,,9,,,,,,, HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage / 9/ /,9,,,9,,,,,,,,,,,,9,,,,,,,,, 9,,,,,,9,,,, 9,,,,9,,9,9,,9

HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage / / 9/,,,,,,,,9,,,,,,,,, 9,,,9,,9,,,,,,,,,,,,,9,,,,,,9,,,, HC-S m³/h stage HC-S m³/h stage HC-S m³/h stage / / /,,,,,,,,,,,,,,,,,,,,,,,9, 9,,,,,,,,,,,9,,,,9,,,9,, 9 9. ASSEMBLY Air water heaters Reventon Group HC-S series can be assembled on the wall or ceiling via rotating mounting brackets. The drawings below show the ways of assembly. In the bigger accommodation, it is recommended to assemble more than one device. Follow the parameters which are provided on the drawings Assembly on the ceiling Assembly on the wall..m.m. PRECAUTIONS & WARNINGS All works concerning electrical installation should be made by the qualified staff, who possess the qualifications due to the domestic and local norms. These recommendations include service and disassembly as well. Not following to the recommendations may cause electrocution, device damages or its incorrect work. - Before service or exchange of the device it is obligatory to cut off the current supply. - Do not cover the inlet and outlet of the device. min..m - Do not use the device in room with high moisture or close to the water basin. -m -m -m Example arrangement for few devices in the room. -m - Do not install, service the device with wet hands or barefoot. - Do not use the device in room with flammable fumes, gas and high concentration of dust. - The device should be kept out of reach of children and animals. - During the assembly use the filter on the hydraulic supply. m - Please use the following valves: ź vent valve in the highest place on the hydraulic installation, ź cut off valve on the supply and return of the device. -m Reventon Group devices can be assembled on the wall or ceiling via rotating mounting bracket. It is possible to assemble the device in parallel on the angle. Please follow the parameters as shown below. - The device should be secured against pressure increase in the water installation. - Before plugging the electric supply check the leak tightness. Mounting on a turntable - The device does not consist of the anti-frost protection. The temperature in the room should not go below C. In such case please empty the device out of water. - It is recommended to check the electric installation before the first start. - It is recommended to use the external current deferential protection. - After the turn off, the elements of device may be warm.. INSTALLATION INSTRUCTIONS The installation should be made by the qualified staff, who possess the needed rights to install electrical devices, as instructed in the following documentation. The duct size for air water heaters Reventon Group HC-S should be chosen by the designer. - After operating time of the device, please utilize it concerning the local norms and regulations.

It is recommended to clean the device periodically: Fan speed controller HC A heating coil blow through by compressed air, fan casing and blades clean form the dirt. - If the device is not used for a longer time disconnect the voltage supply. - The device is transported with the closed air stators. It is essential to open them in % before first start. Not keeping to the following recommendation may cause the damages of the fan. - Opening the air stators must be made by two hands in parallel. Not keeping to the following recommendation may cause the damages of the air stators. designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems control levels: ---- -V Power supply voltage: V AC/-Hz Allowable current output: A Protection: thermal switch Dimensions: mm x mm x mm Weight:,kg Obudowa w stopniu ochrony : IP Fan speed controller HC A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems control levels: -----V Power supply voltage: V AC/-Hz Allowable current output: A Maximum ambient temperature C Maximum temperature controller C, limited motor protection. Dimensions: mm x mm x mm Weight:, kg Degree of protection: IP Fan speed controller HC A While plugging the device to the water installation do remember to hold its stub pipes by pipes spanner, not keeping to the recommendation may cause the damages of the heating coil. designed to change the single-phase fan's speed voltage controlled in industrial supply and heating system control levels: -----V Power supply voltage: V AC/-Hz Allowable current output: A Maximum ambient temperature C Maximum temperature controller C, limited motor protection. Dimensions: mm x 9 mm x mm Weight:, kg Degree of protection: IP Fan speed controller HC A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems. CONTROLS To make easier the usage of the Reventon Group devices we also offer the additional controls: control levels: -----V Power supply voltage: V AC/-Hz Allowable current output: A Maximum ambient temperature C Maximum temperature controller C, limited motor protection. Dimensions: mm x 9 mm x mm Weight:, kg Degree of protection: IP -stage speed controllers with thermostat Controller is used to regulate devices equipped with -stage fans. It has -stage speed control and thermostat built in. In addition, the unit controls the operation of the actuators installed on the control valve. Works in both heating and cooling modes. Independent control switch system -stage fan adjustment Electric valve and thermostat controlled fan HEAT / COOL switch ON / OFF switch Temperature range: C~ C Control accuracy: < C Dimensions: xx mm Voltage: V / ~Hz Rated current: A Degree of casing's protection: IP Weight:,kg Fan speed controller HC,A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems control levels: ---- -V Power supply voltage: V AC/-Hz Allowable current output:, A Protection: thermal switch Dimensions: mm x mm x mm Weight:,kg Degree of protection: IP Fan speed controller HC A designed to change the single-phase fan's speed voltage controlled in industrial supply and heating systems control levels: -----V Power supply voltage: V AC/-Hz Allowable current output: A Maximum ambient temperature C Maximum temperature controller C, limited motor protection. Dimensions: mm x 9 mm x mm Weight:,kg Degree of protection: IP Two-way valve with actuator ¾ The two-way valve with actuator is used to automatically regulate the flow of the heating medium. Works with Reventon HC devices with ¾ connection diameters. The kit consists of a two-way valve and a double-open / open actuator. Power: V / Hz Total current: <,A Input: <, (,VA) Auxiliary microswitch: A Maximum operating temperature: ºC Class of insulation: double Degree of protection: IP Closing time: - min Adjustment stroke:, mm

Module relay RM-A Relay module RM-A opens and closes the circuit to affect the work Programmable room thermostat HC of other devices. It can be used to connect a receiver with higher power than the relay in the controller allows. Maximum rated current is A. Number of temperature levels: Hysteresis:, /ºC Power: baterie AA Switching: VAC/Hz () A Operating temperature range: -ºC Temperature control range: -ºC Accuracy of temperature:,ºc Number of programs: 9 Power supply: V AC Maximum rated current: A Input NO/COM Input SL Connection of a regulator with the voltage relay V Dimension [mm] W- H- D- Manual thermostat HC Thermostat is a device that is designed to maintain a pre-set room temperature. Operating temperature: -ºC Temperature control range: -ºC Accuracy of temperature: ºC Number of programs: Rated current: A CONTROLLERS COOPERATION WITH EQUIPMENT HC A HC A HC A FSHC- FSHC- FSHC-9 HC A FSHC- RM-A RMA- HCS RTHCS-9 HC, A FSHC- HC A FSHX- HC-S 9 HC-S 9 Model Code HC-S 9 HC-S 9 HC-S HC-S Farmer IP-S Farmer IP. CONNECTION SCHEMES LEGEND:. Power. Main switch, overcurrent circuit breaker *. Air water heater Reventon HC. -stage speed controllers with thermostat A-work in continuous mode B-operation in thermostatic mode. Two-way valve with actuator HC ¾ ". Fan speed controller HC. Manual thermostat HC. Digital programmable thermostat HC 9. Relay module RM-A * main switch and safety fuses are not included in the set

. TERMS OF WARRANTY I.Reventon Group Sp. z o.o. [Ltd.] B Montazowa Street, - Bielsko-Biała,Poland, is the producer of the Reventon Group brand. The warranty concerns the following devices and it is valid for (two) years: - air water heater Reventon Group HC-S kw V - air water heater Reventon Group HC-S kw V - air water heater Reventon Group HC-S kw V - air water heater Reventon Group HC-S kw V - air water heater Reventon Group HC-S kw V - air water heater Reventon Group HC-S 9 kw V -modified equipment that has been modified or repaired without written agreement of the producer; - connecting additional equipment, which is not recommended by the producer or inconsistent with the technical documentation; - improper power supply. c) Elements which wear and tear such as discolor or using. VI. All changes in record in the warranty terms or any constructive modifications, independent service outside the Reventon Group Sp. z o.o. service or use, uncaring, makes the warranty not valid. II. Warranty is valid in the European Union. III. The terms of warranty are valid from purchasing the device (the date issuing a document confirming the purchase of the device) but not further than (thirty) months from leaving the producer s warehouse. VII. To obtain the service it is needed to send to the producer warranty card with the signature, document confirming the purchase, (copy of the invoice) and correctly filled the warranty form. VIII. Not following to any of warranty regulations makes the warranty not valid. IV. The defects revealed during the warranty period will be removed free of charge in working days. The service will be done by the installation company due to the terms included in warranty card. The elements will be supplied by the Reventon Group Sp. z o.o. during the warranty period. IX. All correspondence, returns, complains should be send to the following address: Reventon Group Sp. z o.o. B Montazowa Street, - Bielsko-Biała, Poland or e-mail: serwis@reventongroup.eu V. Warranty does not cover the parts of the device subject to normal maintenance and the cases as below: The producer reserves the rights to make changes to the technical documentation without previous notice. a) Mechanical defects, damages from the impact of the improper transportation or damages through improper storage. b) Defects through: - improper usage and service; - using the device in the improper conditions (too high humidity, too high or too low temperature, impact of the surrounding, sun etc.);

Warranty card : : : : : Reventon Group [Ltd.] B Montazowa Street, - Bielsko-Biała, Poland

Reventon Group Sp. z o.o., ul.montażowa B, - Bielsko-Biała, Polska, www.reventongroup.eu