Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd

Similar documents
Firetect C. Fire protective products: Fire protective board

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

European Technical Assessment. ETA-14/0028 of 22 September General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-12/0166 of 18 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-08/0315 of 15 May General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-14/0269 of 13 October General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical ETA-12/0084 Assessment of 3 February 2017 General Part

European Technical Assessment. ETA-10/0352 of 6 July English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-15/0440 of 6 July English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-02/0024 of 17 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-12/0084 of 14 April English translation prepared by DIBt - Original version in German language.

Trade name of the construction product Fix Master Injection system Fit-Ve 200 for rebar connection. Karhutie 9 Fl NURMIJÄRVI FINNLAND

European Technical Assessment. ETA-14/0323 of 10 October General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-15/0296 of 27 August English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-10/0255 of 22 August General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-11/0492 of 26 June General Part. Technical Assessment Body issuing the European Technical Assessment:

concrete Indo Spark Constructions services 198 E Tararani Chowk Near Geeta mandir KOLHAPUR Maharastra INDIEN

European Technical Assessment. ETA-15/0195 of 12 November English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-16/0693 of 29 August English translation prepared by DIBt - Original version in German language.

Trade name of the construction product Injection system Hilti HIT-HY 110. This version replaces ETA-13/1037 issued on 17 January 2014

European Technical Assessment. ETA-15/0771 of 14 December English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-09/0171 of 18 March English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-14/0125 of 26 May General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-08/0314 of 8 August General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-14/0030 of 26 June General Part. Technical Assessment Body issuing the European Technical Assessment:

European Technical Assessment. ETA-13/0651 of 18 June English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-16/0958 of 11 April English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-13/0652 of 17 March English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-16/0515 of 14 December English translation prepared by DIBt - Original version in German language

European Technical ETA-13/0909 Assessment of 8 December 2016 General Part

European Technical Assessment. ETA-12/0605 of 4 May English translation prepared by DIBt - Original version in German language.

European Technical ETA-15/0270 Assessment of 2 February 2016 General Part

Trade name of the construction product Injection system Hilti HIT-HY 200-A with HIT-Z / HIT-Z-F / HIT-Z-R

for concrete Apolo MEA Befestigungssysteme GmbH Industriestraße Aichbach DEUTSCHLAND Apolo MEA Befestigungssysteme GmbH, Plant2 Germany

European Technical Assessment. ETA-16/0509 of 17 August English translation prepared by DIBt - Original version in German language.

AC100-PRO Ice. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND

European Technical Assessment. ETA-11/0360 of 6 October English translation prepared by DIBt - Original version in German language.

Trade name of the construction product Fix Master Injection system FIT-Ve 200 or FIT-Wi 200 for concrete. Karhutie 9 Fl NURMIJÄRVI FINNLAND

European Technical ETA-07/0332 Assessment of 30 January 2015 General Part

European Technical Assessment. ETA-16/0107 of 22 March English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-11/0240 of 7 May English translation prepared by DIBt - Original version in German language.

EN :2012 EN :2012 ETAG 026 part 3:2011 DECLARATION OF PERFORMANCE. Sikasil -670 Fire

European Technical Approval ETA-08/0035 This ETA replaces ETA-08/0035 with validity from till

European Technical ETA-06/0078 Assessment of 21 January 2015 General Part

European Technical Assessment. ETA-07/0121 of 30 March English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-03/0032 of 27 August English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-02/0020 of 11 December English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-07/0219 of 19 September English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-16/0488 of 6 July English translation prepared by DIBt - Original version in German language.

European Technical Assessment

fermacell AESTUVER Fire Protection Joint Seal M

European Technical Assessment. ETA-15/0388 of 30 September English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-18/0213 of 17 May English translation prepared by DIBt - Original version in German language.

European Technical ETA-07/0025 Assessment of 9 December 2016 General Part

European Technical ETA-10/0305 Assessment of 6 December 2017 General Part

European Technical ETA-11/0080 Assessment of 9 February 2016 General Part

European Technical Assessment ETA 17/1007 of 02/05/2018

European Technical Assessment. ETA-12/0208 of 26 May English translation prepared by DIBt - Original version in German language.

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

European Technical Assessment. ETA-05/0069 of 5 August English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-14/0475 of 19 December English translation prepared by DIBt - Original version in German language

DECLARATION OF PERFORMANCE. No EN

DECLARATION OF PERFORMANCE. No EN

European Technical ETA-06/0047 Assessment of 8 February 2016 General Part

European Technical ETA-07/0142 Assessment of 9 December 2016 General Part

Stanley Black & Decker Deutschland GmbH Richard-Klinger-Straße Idstein DEUTSCHLAND. Manufacturing plant Manufacturing Plant 4 and Plant 9

European Technical Assessment. ETA-99/0010 of 15 December English translation prepared by DIBt - Original version in German language

European Technical ETA-07/0135 Assessment of 9 December 2016 General Part

1. Terms defined in the Construction Products Regulation (CPR)

European Technical Assessment. ETA-10/0258 of 2 August English translation prepared by DIBt - Original version in German language.

European Technical Assessment. ETA-11/0163 of 22 May English translation prepared by DIBt - Original version in German language.

European Technical Assessment

DECLARATION OF PERFORMANCE. No EN

European Technical Assessment. ETA-15/0352 of 12 April English translation prepared by DIBt - Original version in German language.

European Technical Assessment

European Technical Assessment. ETA-17/0624 of 8 September English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-16/0276 of 23 September English translation prepared by DIBt - Original version in German language

European Technical Assessment. ETA-07/0211 of 19 May English translation prepared by DIBt - Original version in German language.

European Technical Approval ETA-10/0161

European Technical Assessment. ETA-11/0095 of 11 March English translation prepared by DIBt - Original version in German language.

DECLARATION OF PERFORMANCE

European Technical ETA-15/0815 Assessment of 1 February 2016 General Part

European Technical Assessment. ETA-11/0288 of 10 September English translation prepared by DIBt - Original version in German language

SHEH KAI PRECISION CO., LTD No. 1, Ben Gong 1st Rd., Ben Chou Industrial Park, KAOHSIUNG TAIWAN R.O.C

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

GNB-CPR Position Paper: Issuance of certificates under CPR

European Technical Assessment. ETA-05/0120 of 14 February English translation prepared by DIBt - Original version in German language

European Technical ETA-12/0607 Assessment of 18 January 2018 General Part

DECLARATION OF PERFORMANCE. DoP: 0094 for Injection System fischer FIS V (Bonded anchor for use in concrete) EN

European Technical Assessment. ETA-05/0069 of 3 July English translation prepared by DIBt - Original version in German language.

DECLARATION OF PERFORMANCE. No EN

European Technical Assessment. ETA-15/0435 of 21 December English translation prepared by DIBt - Original version in German language

DECLARATION OF PERFORMANCE

European Technical ETA-10/0005 Assessment of 29 January 2016 General Part

European Technical Assessment ETA-14/0176

European Technical Assessment. ETA-10/0005 of 10 May English translation prepared by DIBt - Original version in German language.

European Technical ETA-13/1038 Assessment of 29 January 2016 General Part

Transcription:

Member of www.eota.eu UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. designated according to Article 29 of the Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment, www.eota.eu) European Technical Assessment ETA 14/0161 of 12/06/2014 Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd Trade name of the construction product Product family to which the construction product belongs NFEL Fire Collar Fire Stopping and Sealing Product: Penetration Seals Manufacturer Northern Fire Engineering Ltd 40 Crompton Road Heaton Newcastle on Tyne NE6 5QL Manufacturing plant(s) A/006 This European Technical Assessment contains This European Technical Assessment is issued in accordance with regulation (EU) No 305/2011, on the basis of 9 pages including 1 Annex which forms an integral part of this assessment. ETAG 026-2, edition 2011, used as European Assessment Document (EAD). Translations of this European Technical Assessment in other languages shall fully correspond to the original issued document and should be identified as such. Communication of this European Technical Assessment, including transmission by electronic means, shall be in full. However, partial reproduction may be made, with the written consent of the issuing Technical Assessment Body. Any partial reproduction has to be identified as such. ETA 14/0161 of 12/06/2014 page 1 of 9

Table of Contents I. SPECIFIC PARTS OF THE EUROPEAN TECHNICAL ASSESSMENT... 3 1 Technical description of the product... 3 2 Specification of the intended uses of the product in accordance with the applicable European Assessment Document (Hereinafter EAD): ETAG 026-2... 3 3 Performance of the product and references to the methods used for its assessment... 4 4 ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE (HEREINAFTER AVCP) SYSTEM APPLIED, WITH REFERENCE TO ITS LEGAL BASE... 5 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable EAD... 5 ANNEX A Resistance to Fire Classification NFEL Fire Collar... 7 A.1 Flexible or rigid wall constructions with wall of minimum 100 mm... 7 A.1.1 Penetration seals, in drywalls and concrete/masonry walls... 7 A.2 Rigid floor constructions with floor of minimum 150 mm... 8 A.2.1 Penetration seals, in concrete floors... 8 ETA 14/0161 of 12/06/2014 Page 2 of 9

I. SPECIFIC PARTS OF THE EUROPEAN TECHNICAL ASSESSMENT 1 Technical description of the product 1) NFEL Fire Collar is a pipe closure device used to form penetration seals where combustible pipes penetrate walls and floors. 2) The NFEL Fire Collar is supplied with intumescent liner complete within powder coated metal steel shell, to be clamped around the service and screw fixed back to the supporting element. The NFEL Fire Collar has two half shells with slide together fixing. 3) The applicant has submitted a written declaration that the product and/or constituents of the product contains no substances which have been classified as dangerous according to Directive 67/548/EEC and Regulation (EC) No. 1272/2008 and listed in the indicative list on dangerous substances of the EGDS taking into account the installation conditions of the construction product and the release scenarios resulting from there. In addition to the specific clauses relating to dangerous substances contained in this European Technical Assessment, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the Construction Products Regulation, these requirements need also to be complied with, when and where they apply. 4) The use catagory of NFEL Fire Collar in relation to BWR 3 (Hygiene, health and environment) is IA1, S/W3 2 Specification of the intended uses of the product in accordance with the applicable European Assessment Document (Hereinafter EAD): ETAG 026-2 Detailed information and data is given in Annex A. The intended use of system NFEL Fire Collar is to reinstate the fire resistance performance of flexible wall and rigid wall and floor constructions, where they are penetrated by services. 1) The specific elements of construction that the system NFEL Fire Collar may be used to provide a penetration seal in, are as follows: Flexible walls: Rigid walls: Rigid floors: The wall must have a minimum of 100 mm and comprise steel studs lined on both faces with minimum 2 layers of 12.5 mm thick boards. The wall must have a minimum of 100 mm and comprise concrete, aerated concrete or masonry, with a minimum density of 650 kg/m3. The floor must have a minimum of 150 mm and comprise aerated concrete or concrete with a minimum density of 650 kg/m3. The supporting construction must be classified in accordance with EN 13501-2 for the required fire resistance period. 2) The system NFEL Fire Collar may be used to provide a penetration seal with specific supporting constructions and substrates (for details see Annex A). ETA 14/0161 of 12/06/2014 Page 3 of 9

3) The provisions made in this European Technical Assessment are based on an assumed working life of the NFEL Fire Collar of 10 years, provided that the conditions laid down in the manufacturers datasheet and instructions for the packaging/transport/storage/installation/ use/repair are met. The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works. 4) Type Z 2 : intended for use at internal conditions with humidity classes other than Z1, excluding temperatures below 0 C. 3 Performance of the product and references to the methods used for its assessment Product-type: Pipe Collar Intended use: Penetration Seal Basic requirement for construction work Basic Requirement BWR 1 Mechanical resistance and stability Performance - None Not relevant BWR 2 Safety in case of fire EN 13501-1 Reaction to fire Class F EN 13501-2 Resistance to fire Annex A BWR 3 Hygiene, health and environment EN 1026:2000 Air permeability (material property) No performance determined ETAG 026-2, Annex C Water permeability (material property) No performance determined Declaration of manufacturer Release of dangerous substances BWR 4 Safety in use Use categories: IA1, S/W3 Declaration of manufacturer EOTA TR 001:2003 Mechanical resistance and stability No performance determined EOTA TR 001:2003 Resistance to impact/movement No performance determined EOTA TR 001:2003 Adhesion No performance determined BWR 5 Protection against noise EN 10140-2/ EN ISO 717-1 Airborne sound insulation No performance determined BWR 6 Energy economy and heat retention EN 12664, EN 12667 or EN 12939 EN ISO 12572 EN 12086 Thermal properties Water vapour permeability General aspects relating to fitness for use No performance determined No performance determined EOTA TR 024:2009, clause 3.1.11 & 3.1.12 Durability and serviceability Z 2 BWR 7 Sustainable use of natural resources - - No performance determined ETA 14/0161 of 12/06/2014 Page 4 of 9

4 ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE (HEREINAFTER AVCP) SYSTEM APPLIED, WITH REFERENCE TO ITS LEGAL BASE According to the decision 1999/454/EC Commission Decision of date 22nd June 1999 on on the procedure for attesting the conformity of construction products pursuant to Article 20(2) of Council Directive 89/106/EEC as regards fire stopping, fire sealing and fire protective products, published in the Official Journal of the European Union (OJEU) L178/52 of 14/07/1999, see http://eur-lex.europa.eu/joindex.do) of the European Commission 1, as amended, the system(s) of assessment and verification of constancy of performance (see Annex V to Regulation (EU) No 305/2011) given in the following table(s) applies (apply). Product(s) Intended use(s) Level(s) or class(es) System(s) Fire stopping and Fire Sealing Products For fire compartmentation and/or fire protection or fire performance Any 1 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable EAD Tasks of the manufacturer: Factory production control The manufacturer shall exercise permanent internal control of production. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic manner in the form of written policies and procedures, including records of results performed. This production control system shall ensure that the product is in conformity with this European Technical Assessment. The manufacturer may only use initial / raw / constituent materials stated in the technical documentation of this European Technical Assessment. The factory production control shall be in accordance with the Control Plan of 13 th May 2014 relating to the European Technical Assessment ETA 14/0161 issued on 12/06/14 which is part of the technical documentation of this European Technical Assessment. The "Control Plan" is laid down in the context of the factory production control system operated by the manufacturer and deposited at UL International (UK) Ltd. The results of factory production control shall be recorded and evaluated in accordance with the provisions of the Control Plan. 1 Official Journal of the European Communities L178/52 of 14/7/1999 ETA 14/0161 of 12/06/2014 Page 5 of 9

Other tasks of the manufacturer Additional information The manufacturer shall provide a technical data sheet and an installation instruction with the following minimum information: (a) Technical data sheet: Field of application: Building elements for which the penetration seal is suitable, type and properties of the building elements like minimum, density, and - in case of lightweight constructions the construction requirements. Limits in size, minimum etc. of the penetration seal Construction of the penetration seal including the necessary components and additional products (e.g. backfilling material) with clear indication whether they are generic or specific. (b) Installation instruction: Steps to be followed Procedure in case of retrofitting Stipulations on maintenance, repair and replacement 6 Issued on: 12 th June 2014 Report by: Reviewed by: C. Johnson C. W. Miles Staff Engineer Business Manager Europe & Latin America Building and Life Safety Technologies Building and Life Safety Technologies For and on behalf of UL International (UK) Ltd. ETA 14/0161 of 12/06/2014 Page 6 of 9

ANNEX A Resistance to Fire Classification NFEL Fire Collar A.1 Flexible or rigid wall constructions with wall of minimum 100 mm A.1.1 Penetration seals, in drywalls and concrete/masonry walls Penetration Seal: Combustible pipes fitted with NFEL Fire Collars to both sides of the wall. Construction details: A.1.1.1 upvc* Pipes NFEL Fire Collar Inlay Classification Internal Diameter x Length 50-55 mm Ø and 2 3.7 mm wall 55 x 50 mm 4 mm 82 mm Ø and 3 3.5 mm wall 82 x 50 mm 6 mm 110 mm Ø and 2.2 8.1 mm wall 110 x 50 mm 8 mm EI 120 C/U 125 mm Ø and 3.7 9.2 mm wall 125 x 60 mm 12 mm 160 mm Ø and 3.2 11.8 mm wall 160 x 60 mm 16 mm * According to EN 1452-1, EN 1329-1 or EN 1453-1. In Germany the pipe must additionally comply with DIN 19531-10 ETA 14/0161 of 12/06/2014 Page 7 of 9

A.2 Rigid floor constructions with floor of minimum 150 mm A.2.1 Penetration seals, in concrete floors Penetration Seal: Combustible pipes fitted with NFEL Fire Collar to the soffit of the floor. Construction details: A.2.1.1 upvc* Pipes NFEL Fire Collar Inlay Classification Internal Diameter x Length 50 mm Ø and 2.5 3.7 mm wall 55 x 50 mm 4 mm EI 240 C/U 82 mm Ø and 3 3.5 mm wall 82 x 50 mm 6 mm 110 mm Ø and 2.2 8.1 mm wall 110 x 50 mm 8 mm EI 180 C/U 125 mm Ø and 3.7 9.2 mm wall 125 x 60 mm 12 mm EI 120 C/U 160 mm Ø and 3.2 11.8 mm wall 160 x 60 mm 16 mm EI 180 C/U * According to EN 1452-1, EN 1329-1 or EN 1453-1. In Germany the pipe must additionally comply with DIN 19531-10 ETA 14/0161 of 12/06/2014 Page 8 of 9

PE* Pipes NFEL Fire Collar Inlay Classification Internal Diameter x Length 160 mm Ø and 10 mm wall 160 x 60 mm 16 mm EI 60 U/C * PE According to EN 12201-2, EN 1519-1 and EN 12666-1. In Germany the pipes have additionally to comply with DIN 19535-10 Composite Combustible* Pipes 110 mm Ø and 5.3 mm wall * ABS inner/pvc outer NFEL Fire Collar Internal Diameter x Length Inlay Classification 110 x 50 mm 8 mm EI 180 U/C PP* Pipes NFEL Fire Collar Inlay Classification Internal Diameter x Length 110 mm Ø and 3.8 mm wall 110 x 60 mm 16 mm EI 240 U/C * PE According to EN 12201-2, EN 1519-1 and EN 12666-1. In Germany the pipes have additionally to comply with DIN 19535-10 ETA 14/0161 of 12/06/2014 Page 9 of 9

Notified Body No. 0843 cpr Notified Body, UL International (uk) Ltd., wonersh House, The Guildway, old Portsmouth Road, Guildford, Surrey, GU3 1LR, United Kingdom Certificate of constancy of performance 0843-CPR-0{90 In compliance with the Regulation 305l2O11lEU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation or CPR), this certificate applies to the construction product NFEL Fire Gollar Penetration Seal Glassified for use in flexible & solid walls and solid ftoors A pipe closure device used to form penetration seals where combustible pipes penetrate walls and floors. The NFEL Fire Collar is supplied with intumescent liner complete within powder coated metal steel shell, to be clamped around the service and screw fixed back to the supporting element. The NFEL Fire Collar has two half shells with slide together fixing. produced by Northern Fire Engineering Ltd 40 Crompton Road Heaton Newcastle on Tyne NE6 sql and produced in the manufacturing plant(s) A/006 This certifteat+ attests that all provisions concerning the assessment and verification of constancy of performance described in the ETA: ETA 14/0161 under system AVCP 1 for the performance set out in this certificate are applied and that NFEL Fire Collar fulfil all the prescribed requirements for these performances. This certificate was first issued on 16th July 2A14 and will remain valid as long as the ETA remains valid and the manuffiing conditions in the plant or the factory production control itself are not modified significantly, unless suspended or withdrawn by the product certification body. Firstissuedate 16h July 2014 Karl Harland Quality Engineering Manager UL lnternational (UK) Ltd. 274P-F0403.1sre 6.0 wone rs h Ho u se, rhe., l'' o''j*,i 8'ilT?l l'i,l H:i Cuildford,5urrey, CU3 rlr, United Kingdom

cpr Notified Body, ur rntell?iifhf,f-3i{.}fi;o?:xi,o,,", rhe Guirdway, ord Portsmouth Road, Guildford, Surrey, GU3 1LR, United Kingdom Annex: Detailed information sheet Certificate Number: 0843-CPR-01 90 ProducUllevice descri ption : NFEL Fire Collar Applicant designation: Northern Fire Engineering Ltd 40 Crompton Road Heaton Newcastle on Tyne NE6 sql Product Information: NFEL Fire Collar The referenced product complies with: A - All the relevant requirements as per ETA 1410161 ETA issue date: 12th June 2014 t;{,lt /"/p'/ - Karl Harland Quality Engineering Manager UL International (UK) Ltd. 2rcP-F04031$ue 6.0 wo n e rs h Ho u se, rh e o, l, ot#; 8,ilT?l Ltl,il H:"ri Cuildford, Surrey, CU3 rlr, United Kingdom

Doc: CPR14-0161 Declaration of Performance (in accordance with Annex III of the Regulation (EU) Nr. 305/2011 (Construction Products Regulation) 1. Unique identification code of the product-type:- NFEL Fire Collar, Series 6100 2. Type, batch or serial number as required pursuant to Article 11(4):- Refer to product label displayed on the product 3. Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer:- Fire stopping and sealing product for penetration seals (see ETA-14/0161) 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required pursuant to Article 11(5):- Northern Fire Engineering Ltd, 40 Crompton Road, Heaton, Newcastle upon Tyne, NE6 5QL, UK 5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2):- n/a 6. System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V:- System 1 7. In the case of the declaration of performance concerning a construction product covered by a harmonised standard:- n/a 8. In case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued:- UL International (UK) Ltd, The Guildway, Old Portsmouth Road, Guildford, GU3 1LR, UK issued ETA 14/0161 on the basis of ETAG 026-1 and ETAG 026-2 and who performed initial type testing, inspection of manufacturing plant and factory production control, continuous surveillance of factory production control and audit testing of samples under system 1 and issued certificate of constancy of performance 0843-CPR-0190

Doc: CPR14-0161 9. Declared performance:- Essential characteristic Performance Harmonised technical specification Reaction to fire Class F 13501-1 Resistance to fire See ETA 14/0161 for resistance to 13501-2 fire and field of application Release of dangerous Does not contain dangerous ETAG 026-1 clause 2.4.5 substances substances Durability and serviceability Z2 ETAG 026-2 clause 1.2 Other Not applicable/no performance declared ETAG 026-2 clause 2.3 10. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer: Northern Fire Engineering Ltd Signed upon this date:- 25/09/2014 at:- Newcastle upon Tyne (Signature or equivalent authorised by the issuer)

Member of www.eota.eu UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. designated according to Article 29 of the Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment, www.eota.eu) European Technical Assessment ETA 14/0195 of 18/09/2014 Technical Assessment Body issuing the ETA and designated according to Article 29 of the Regulation (EU) No 305/2011: UL International (UK) Ltd Trade name of the construction product Product family to which the construction product belongs NFEL Pipe Wrap Fire Stopping and Sealing Product: Penetration Seals Manufacturer Northern Fire Engineering Ltd 40 Crompton Road Heaton Newcastle on Tyne NE6 5QL Manufacturing plant(s) A/006 This European Technical Assessment contains This European Technical Assessment is issued in accordance with regulation (EU) No 305/2011, on the basis of 11 pages including 1 Annex which forms an integral part of this assessment. ETAG 026-2, edition 2011, used as European Assessment Document (EAD). Translations of this European Technical Assessment in other languages shall fully correspond to the original issued document and should be identified as such. Communication of this European Technical Assessment, including transmission by electronic means, shall be in full. However, partial reproduction may be made, with the written consent of the issuing Technical Assessment Body. Any partial reproduction has to be identified as such. ETA 14/0195 of 18/09/2014 page 1 of 9

Table of Contents I. SPECIFIC PARTS OF THE EUROPEAN TECHNICAL ASSESSMENT... 3 1 Technical description of the product... 3 2 Specification of the intended uses of the product in accordance with the applicable European Assessment Document (Hereinafter EAD): ETAG 026-2... 3 3 Performance of the product and references to the methods used for its assessment... 4 4 ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE (HEREINAFTER AVCP) SYSTEM APPLIED, WITH REFERENCE TO ITS LEGAL BASE... 5 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable EAD... 5 6 Issued on:... 6 ANNEX A Resistance to Fire Classification NFEL Pipe Wrap... 7 A.1 Rigid floor constructions with minimum 150 mm... 7 A.1.1 Penetration seals, in floors... 7 A.2 100 mm deep fire rated mortar seal in rigid floor constructions with floor of minimum 150 mm... 8 A.2.1 Penetration seals, in mortar seals in concrete floors... 8 A.3 Rigid walls constructions with minimum 100 mm... 10 A.3.1 Penetration seals for plastic pipes, in walls... 10 A.3.2 Penetration seals for insulated metal pipes, in walls... 11 ETA 14/0195 of 18/09/2014 Page 2 of 11

I. SPECIFIC PARTS OF THE EUROPEAN TECHNICAL ASSESSMENT 1 Technical description of the product 1) NFEL Pipe Wrap is a pipe closure device used to form penetration seals where combustible pipes penetrate floors. 2) The NFEL Pipe Wrap is supplied with intumescent liner complete within polyethylene sleeve, to be wrapped around the service and cast into the supporting element. 3) The applicant has submitted a written declaration that the product and/or constituents of the product contains no substances which have been classified as dangerous according to Directive 67/548/EEC and Regulation (EC) No. 1272/2008 and listed in the indicative list on dangerous substances of the EGDS taking into account the installation conditions of the construction product and the release scenarios resulting from there. In addition to the specific clauses relating to dangerous substances contained in this European Technical Assessment, there may be other requirements applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the Construction Products Regulation, these requirements need also to be complied with, when and where they apply. 4) The use catagory of NFEL Pipe Wrap in relation to BWR 3 (Hygiene, health and environment) is IA1, S/W3 2 Specification of the intended uses of the product in accordance with the applicable European Assessment Document (Hereinafter EAD): ETAG 026-2 Detailed information and data is given in Annex A. The intended use of system NFEL Pipe Wrap is to reinstate the fire resistance performance of flexible wall and rigid wall and floor constructions, where they are penetrated by services. 1) The specific elements of construction that the system NFEL Pipe Wrap may be used to provide a penetration seal in, are as follows: Rigid floors: Mortar seals: Rigid walls: The floor must have a minimum of 150 mm and comprise aerated concrete or concrete with a minimum density of 650 kg/m 3. The mortar seal must have a minimum of 100 mm and be installed within a floor as above. The floor must have a minimum of 100 mm and comprise aerated concrete, concrete or masonry with a minimum density of 650 kg/m 3. The supporting construction must be classified in accordance with EN 13501-2 for the required fire resistance period. 2) The system NFEL Pipe Wrap may be used to provide a penetration seal with specific supporting constructions and substrates (for details see Annex A). ETA 14/0195 of 18/09/2014 Page 3 of 11

3) The provisions made in this European Technical Assessment are based on an assumed working life of the NFEL Pipe Wrap of 10 years, provided that the conditions laid down in the manufacturers datasheet and instructions for the packaging/transport/storage/installation/ use/repair are met. The indications given on the working life cannot be interpreted as a guarantee given by the producer, but are to be regarded only as a means for choosing the right products in relation to the expected economically reasonable working life of the works. 4) Type X: intended for use at conditions exposed to weathering. 3 Performance of the product and references to the methods used for its assessment Product-type: Pipe Collar Intended use: Penetration Seal Basic requirement for construction work Basic Requirement BWR 1 Mechanical resistance and stability Performance - None Not relevant BWR 2 Safety in case of fire EN 13501-1 Reaction to fire Class F EN 13501-2 Resistance to fire Annex A BWR 3 Hygiene, health and environment EN 1026:2000 Air permeability (material property) No performance determined ETAG 026-2, Annex C Water permeability (material property) No performance determined Submission of chemical constitution or declaration of manufacturer Release of dangerous substances BWR 4 Safety in use Use categories: IA1, S/W3 Declaration of manufacturer EOTA TR 001:2003 Mechanical resistance and stability No performance determined EOTA TR 001:2003 Resistance to impact/movement No performance determined EOTA TR 001:2003 Adhesion No performance determined BWR 5 Protection against noise EN 10140-2/ EN ISO 717-1 Airborne sound insulation No performance determined BWR 6 Energy economy and heat retention EN 12664, EN 12667 or EN 12939 EN ISO 12572 EN 12086 EOTA TR 024:2009, clause 3.1.11 & 3.1.12 Thermal properties Water vapour permeability General aspects relating to fitness for use Durability and serviceability BWR 7 Sustainable use of natural resources No performance determined No performance determined X - - No performance determined ETA 14/0195 of 18/09/2014 Page 4 of 11

4 ASSESSMENT AND VERIFICATION OF CONSTANCY OF PERFORMANCE (HEREINAFTER AVCP) SYSTEM APPLIED, WITH REFERENCE TO ITS LEGAL BASE According to the decision 1999/454/EC Commission Decision of date 22nd June 1999 on on the procedure for attesting the conformity of construction products pursuant to Article 20(2) of Council Directive 89/106/EEC as regards fire stopping, fire sealing and fire protective products, published in the Official Journal of the European Union (OJEU) L178/52 of 14/07/1999, see http://eur-lex.europa.eu/joindex.do) of the European Commission 1, as amended, the system(s) of assessment and verification of constancy of performance (see Annex V to Regulation (EU) No 305/2011) given in the following table(s) applies (apply). Product(s) Intended use(s) Level(s) or class(es) System(s) Fire stopping and Fire Sealing Products For fire compartmentation and/or fire protection or fire performance Any 1 5 Technical details necessary for the implementation of the AVCP system, as provided for in the applicable EAD Tasks of the manufacturer: Factory production control The manufacturer shall exercise permanent internal control of production. All the elements, requirements and provisions adopted by the manufacturer shall be documented in a systematic manner in the form of written policies and procedures, including records of results performed. This production control system shall ensure that the product is in conformity with this European Technical Assessment. The manufacturer may only use initial / raw / constituent materials stated in the technical documentation of this European Technical Assessment. The factory production control shall be in accordance with the Control Plan of 22 nd May 2014 relating to the European Technical Assessment ETA 14/0195 issued on 18/09/14 which is part of the technical documentation of this European Technical Assessment. The "Control Plan" is laid down in the context of the factory production control system operated by the manufacturer and deposited at UL International (UK) Ltd. The results of factory production control shall be recorded and evaluated in accordance with the provisions of the Control Plan. 1 Official Journal of the European Communities L178/52 of 14/7/1999 ETA 14/0195 of 18/09/2014 Page 5 of 11

Other tasks of the manufacturer Additional information The manufacturer shall provide a technical data sheet and an installation instruction with the following minimum information: (a) Technical data sheet: Field of application: Building elements for which the penetration seal is suitable, type and properties of the building elements like minimum, density, and - in case of lightweight constructions the construction requirements. Limits in size, minimum etc. of the penetration seal Construction of the penetration seal including the necessary components and additional products (e.g. backfilling material) with clear indication whether they are generic or specific. (b) Installation instruction: Steps to be followed Procedure in case of retrofitting Stipulations on maintenance, repair and replacement 6 Issued on: 18 th September 2014 Report by: Reviewed by: C. Johnson C. W. Miles Staff Engineer Business Manager Europe & Latin America Building and Life Safety Technologies Building and Life Safety Technologies For and on behalf of UL International (UK) Ltd. ETA 14/0195 of 18/09/2014 Page 6 of 11

ANNEX A Resistance to Fire Classification NFEL Pipe Wrap A.1 Rigid floor constructions with minimum 150 mm A.1.1 Penetration seals, in floors Penetration Seal: NFEL Pipe Wrap, cast into soffit of the floor with fire resisting compound/mortar with 30 mm annular space/mortar seal width Construction details: A.1.1.1 upvc* Pipes NFEL Pipe Wrap Width x Thickness Classification 50 mm Ø and 2.2 8.1 mm wall 82 mm Ø and 2.2 8.1 mm wall 110 mm Ø and 2.2 8.1 mm wall 50 mm Ø and 3.6 8.1 mm wall 50 x 3.6 mm EI 180 C/U 82 mm Ø and 3.6 8.1 mm wall 110 mm Ø and 3.6 8.1 mm wall EI 240 C/U 125 mm Ø and 3.7 9.2 mm wall 75 x 3.6 mm 160 mm Ø and 3.2 11.8 mm wall 75 x 7.2 mm * According to EN 1452-1, EN 1329-1 or EN 1453-1. In Germany the pipe must additionally comply with DIN 19531-10 ETA 14/0195 of 18/09/2014 Page 7 of 11

PE/ABS/SAN+PVC* Pipes NFEL Pipe Wrap Width x Thickness Classification 160 mm Ø and 6.2 mm wall 75 x 7.2 mm EI 180 U/C * PE According to EN 12201-2, EN 1519-1 and EN 12666-1, ABS according to EN 1455-1 and SAN+PVC according to EN 1565-1. In Germany the pipes have additionally to comply with DIN 19535-10 A.2 100 mm deep fire rated mortar seal in rigid floor constructions with floor of minimum 150 mm A.2.1 Penetration seals, in mortar seals in concrete floors Penetration Seal: NFEL Pipe Wrap, cast into soffit of the floor with min. 100 mm deep fire resisting compound/mortar with up to 75 mm annular space/mortar seal width. Construction details: A.2.1.1 NFEL Pipe Wrap upvc* Pipes Classification Width x Thickness 110mm Ø and 3.4 mm wall 75 x 1.8 mm 160 mm Ø and 4 mm wall 75 x 5.4 mm EI 180 U/C * According to EN 1452-1, EN 1329-1 or EN 1453-1. In Germany the pipe must additionally comply with DIN 19531-10 ETA 14/0195 of 18/09/2014 Page 8 of 11

PE* Pipes NFEL Pipe Wrap Width x Thickness Classification 110 mm Ø and 4.3 mm wall 50 x 1.8 mm EI 60 U/C 125 mm Ø and 4.9 mm wall 75 x 3.6 mm EI 180 U/C 250 mm Ø and 7.8 mm wall 75 x 14.4 mm EI 180 U/C * PE According to EN 12201-2, EN 1519-1 and EN 12666-1. In Germany the pipes have additionally to comply with DIN 19535-10 ETA 14/0195 of 18/09/2014 Page 9 of 11

A.3 Rigid walls constructions with minimum 100 mm A.3.1 Penetration seals for plastic pipes, in walls Penetration Seal: NFEL Pipe Wrap, fitted into both sides of the wall with mortar used to fill any small gaps. Construction details: A.3.1.1 upvc* Pipes Up to 110 mm Ø and 2.2 8.1 mm wall 125 mm Ø and 3.2 9.2 mm wall 160 mm Ø and 3.2 11.8 mm wall NFEL Pipe Wrap Width x Thickness 50 x 3.6 mm 50 x 5.4 mm Classification^ EI 120 U/C E 180 U/C EI 90 U/C E 120 U/C EI 90 U/C * According to EN 1452-1, EN 1329-1 or EN 1453-1. In Germany the pipe must additionally comply with DIN 19531-10 ^ U/C classification for pipe end configuration covers C/U and C/C classifications also ETA 14/0195 of 18/09/2014 Page 10 of 11

A.3.2 Penetration seals for insulated metal pipes, in walls Penetration Seal: NFEL Pipe Wrap, fitted into both sides of the wall with mortar used to fill any small gaps. Pipes with continuous sustained (CS) 25 mm thick Armaflex AF-25 insulation Construction details: A.3.2.1 Mild and stainless steel pipes Up to 60 mm Ø and 3.7 14.2 mm wall Up to 219 mm Ø and 8.0 14.2 mm wall NFEL Pipe Wrap Width x Thickness 50 x 3.6 mm Classification E 240 C/C EI 90 C/C E 120 C/C EI 45 C/C Copper, mild and stainless steel pipes Up to 42 mm Ø and 1.2 14.2 mm wall Up to 108 mm Ø and 2.2 14.2 mm wall NFEL Pipe Wrap Width x Thickness Classification 50 x 3.6 mm E 240 C/C EI 20 C/C 50 x 3.6 mm ETA 14/0195 of 18/09/2014 Page 11 of 11

Notified Body No. 0843 cpr Notified Body, UL lnternational (uk) Ltd., wonersh House, The Guildway, old Portsmouth Road, Guildford, Surrey, GU3 1LR, United Kingdom Certificate of constancy of performance 0843-CPR-01 91 In compliance with the Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation or CPR), this certificate applies to the construction product NFEL Pipe Wrap Penetration Seal Classified for use in solid floors & Mortar.seats A pipe closure device used to form penetration seals where combustible pipes penetrate floors. The NFEL Pipe Wrap is supplied with intumescent liner complete within polyethylene sleeve, to be wrapped around the service and cast into the supporting element producod by Northern Fire Engineering Ltd 40 Grompton Road Heaton Newcastle on Tyne NE6 sql and produced in the manufacturing plant(s) A/006 This certificate attests that all provisions conccrning the assessment and verification of constancy of performance described in the ETA: ETA 1410195 under system AVCP 1 for the performance set out in this certificate are applied and that NFEL Pipe Wrap fulfil all the prescribed requirements for these performances. This certificate was flrst issued on 16th July 2014 and will remain valid as long as the ETA remains valid and the manufacturing conditions in the plant or the factory production control itself are not modified significantly, unless suspended or withdrawn by the product certification body. First issue date- 16ft July 2014 Karl Harland Quality Engineering Manager UL International (UK) Ltd. 414716 EC kfti. FR sa.k 274P+go3-lse 6.0 UL International (UK) Limited Wonersh House, The Cuildway, Old Portsmouth Road, Cuildford, Surrey, GU3 rlr, United Kingdom

Notified Body No. 0843 CPR Notified Body, UL International (UK) Ltd., Wonersh House, The Guildway, Old Portsmouth Road, Guildford, Surrey, GU3 1LR, United Kingdom Annex: Iletailed information sheet Certifi cate Number: 0843-CPR-01 91 ProducUllevice description : NFEL Pipe Wrap Applicant designation: Northern Fire Engineering Ltd 40 Crompton Road Heaton Newcastle on Tyne NE6 sql Product lnformation: NFEL Pipe Wrap tn" r";sygnced product complies with: A - All the relevant requirements as per ETA 14l019s ETA issue date: 11h July 2014 /'t z.-"/ l' / //-''' c- /*',,/ Karl Harland Quality Engineering Manager UL lnternational (UK) Ltd. 274P-FM0!lsue 6.0 UL International (UK) Limited Wonersh House,The Cuildway, Old Portsmouth Road, Cuildford, Surrey, CU3 rlr, United Kingdom

Doc: CPR14-0195 Declaration of Performance (in accordance with Annex III of the Regulation (EU) Nr. 305/2011 (Construction Products Regulation) 1. Unique identification code of the product-type:- NFEL Pipe Wrap, Series 7000 2. Type, batch or serial number as required pursuant to Article 11(4):- Refer to product label displayed on the product 3. Intended use or uses of the construction product, in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer:- Fire stopping and sealing product for penetration seals (see ETA-14/0195) 4. Name, registered trade name or registered trade mark and contact address of the manufacturer as required pursuant to Article 11(5):- Northern Fire Engineering Ltd, 40 Crompton Road, Heaton, Newcastle upon Tyne, NE6 5QL, UK 5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12(2):- n/a 6. System or systems of assessment and verification of constancy of performance of the construction product as set out in Annex V:- System 1 7. In the case of the declaration of performance concerning a construction product covered by a harmonised standard:- n/a 8. In case of the declaration of performance concerning a construction product for which a European Technical Assessment has been issued:- UL International (UK) Ltd, The Guildway, Old Portsmouth Road, Guildford, GU3 1LR, UK issued ETA 14/0195 on the basis of ETAG 026-1 and ETAG 026-2 and who performed initial type testing, inspection of manufacturing plant and factory production control, continuous surveillance of factory production control and audit testing of samples under system 1 and issued certificate of constancy of performance 0843-CPR-0191

Doc: CPR14-0195 9. Declared performance:- Essential characteristic Performance Harmonised technical specification Reaction to fire Class F 13501-1 Resistance to fire See ETA 14/0195 for resistance to 13501-2 fire and field of application Release of dangerous Does not contain dangerous ETAG 026-1 clause 2.4.5 substances substances Durability and serviceability Type X ETAG 026-2 clause 1.2 Other Not applicable/no performance declared ETAG 026-2 clause 2.3 10. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4. Signed for and on behalf of the manufacturer: Northern Fire Engineering Ltd Signed upon this date:- 09/11/2014 at:- Newcastle upon Tyne (Signature or equivalent authorised by the issuer)