PL PERFORMANCE FIELDS

Similar documents
N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

6-30 Vertical Deep Well. Close Coupled Vertical Turbine Submersible Turbine. Pump Type. Application. Description. Materials

Full-line Product Overview

Industrial. Solutions brands you trust. Product Overview

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Wastewater pumps 3045, For groundwater and sewage

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Pumps SELECTION OF A PUMP

Flygt N-pumps 3231, 3306, 3312, 3356, 3400

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

HOMA Pump, Ansonia Connecticut

Choosing the Right Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

Reliable Long-Term Solutions For Your Toughest Pump

Rotodynamic Pumps INTRODUCTION:

VRD. Sump pump for polluted liquids

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

- Sewage and Sludge Pumps

STAINLESS STEEL UNITS

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Unequaled I Unrivaled I Performance

M-Series Vertical Turbine Pumps. BULLETIN 3A.1 June 2003

K4RH(X) Solids-Handling Pumps

Company name: Created by: Phone:

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

dp pumps the dynamics of water HVAC centrifugal (norm) pumps

Sewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps

Home Pressure Systems

VTP Vertical Turbine, Wet-Pit Pump

SUMP PUMPS, EFFLUENT PUMPS AND SEWAGE PUMPS

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

HASSLE FREE SUBMERSIBLE DL

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

ETP Series - Self Priming Pumps

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

TYPE VL/VLS VERTICAL INLINE PUMPS

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

Electric Submersible Pumps

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Submersible and Immersible Pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

B.K. Machinery (M) Sdn. Bhd. Submersible Pumps. Flexible Vibrator Poker. 1 of 6. Other Construction Machinery

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

JCseries EVAPORATIVE CONDENSER. engineering data

Self-priming centrifugal pumps

MINING EFFICIENT BY DESIGN

Specially Designed Waste Water & Sewage Pumps

Goulds Large Capacity, Single Stage, Double Suction Pump

Model CFTM Chop-FlowTM Pump Chopping While Pumping. Excellent Power & Industrial Solutions

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

CH & EQ centrifugal pumps. High efficiency for cost-effective pumping

Selecting the Correct Fan

NJWEA TECH TRANSFER MARCH 1, 2016

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

SL S.S.N.51D

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

SL EX.4.51D

SECTION STEAM CONDENSATE PUMPS

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

CORNELL PUMP COMPANY MINE DEWATERING WHEN RELIABILITY MATTERS

Tel Group

CombiBloc Close-coupled centrifugal pumps

INDUSTRIAL AND MARINE PUMPING SOLUTIONS

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

PUMPS AND PROP AGITATORS

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

Goulds HSU, HSUL & JCU. Submersible Pumps

MULTISAN Fully automatic sewage and waste water pump

Wells and Pump Servicing Tifft Symposium September 23, 2015

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Goulds Trash Hog. Self-Priming Solids Handling Pumps

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Water Piping and Pumps

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

12 Impeller Replacement

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Electric Submersible Pumps

MARLOW PUMPS RECIRCULATION

UNDERGROUND JUMBO FACE PUMPS

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

SELF-PRIMING PUMPS CORNELL PUMP COMPANY STX & STL SERIES INDUSTRY LEADING EFFICIENCY WITH CYCLOSEAL SYSTEM EFFICIENT BY DESIGN FIVE-YEAR WARRANTY

ENGINE DRIVEN PUMPS PRODUCTS

dualarm Vertical In-Line Pumps

COR-20 STANDALONE MAIN TITLE GOES MODE USER GUIDE HERE

FEATURES. Other Fed-Flush Arrangements

PENGUIN SERIES HSC PUMPS INTRODUCTION

Table of Contents INTMPE OVERVIEW ANSI B73.1 ANSI B73.1M API-610

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Transcription:

PL/LL PUMPS PL/LL 1 PL PERFORMANCE FIELDS SUPERSEDES ISSUED Use for pre-selection only. 3 711 74 7 776 1 1 1 3 4 Flow, l/s 1 1 8 761 781 711 711 3 714 1 1 3 4 Flow, l/s ITT Flygt Series P-7 Electric Submersible Propeller Pumps have a well known and uncontested ability to handle lowhead high capacity pumping. Applications range from agricultural uses, such as irrigation and land drainage, to flood control and the pumping of municipal storm water effluent. Other applications include pumping of water from waste water treatment plants, water used in industrial processes, cooling applications, raw water and water rides in amusement parks.

PL/LL PUMPS PL/LL PL CHARACTERISTICS SUPERSEDES Models 74/7 7/761 776/781 711 711/711 13-63 kw 1-179 kw 18-186 kw 67-6 kw 138-399 kw (17-84 HP) (-4 HP) (34- HP) (9-3 HP) (18-3 HP) ISSUED Models Discharge Tube Dia. (mm) PL-74 7 Heights: PL-7 7 6." to 18" PL-7 8 PL-761 8 Widths: PL-776 1 4.4" to 61" PL-781 1 PL-71 1 1 PL-711 14 Weights: PL-711 14 1, lbs. to, lbs. Installation The integral pump/drive unit is installed in a discharge column. This means that the pump/drive unit may be lowered inside the discharge column down to its seat at the base of the discharge column. The pump is held in place by its own weight. With proper hoisting equipment, it is easy to remove the unit from the column for inspection or service. Propeller Pump Section The pump section includes a propeller and a guide vane system. The latter also forms the bowl assembly, which holds the pump section and driving unit together. The bowl assembly is designed to match the inside diameter of the discharge column with an adequate clearance to raise and lower the entire pump/motor unit. A seat is provided at the bottom of the discharge column to support the weight of the pump/motor unit. The bowl assembly is provided with a replaceable wear ring at the propeller periphery. Materials The outer casing of the driving unit is made of cast iron. The guide vane system (bowl assembly) is made of cast iron. The propeller is available in either cast iron, aluminium bronze or stainless steel depending on pump model and application. Practical Limitations The 7 series can pump liquids at temperatures of up to 4 C (14 F). Maximum pump submergence is m.

Five Low-Cost Types of Installations In order to reduce installation costs, ITT Flygt has standardized the main elements of pumping stations so that they can be combined in different ways to match specific site PL/LL PUMPS PL/LL 3 PL TYPICAL INSTALLATIONS SUPERSEDES ISSUED conditions. The five examples shown here, illustrating the flexibility of the system, provide guidelines for optimizing the design of your station. Suitable where the liquid is pumped to a tunnel, channel or basin with a water level that is nearly constant so that shutoff devices are not required. This arrangement involves the smallest number of steel components; it consists of a circular concrete shaft and a short pipe grouted in place as a base for the pump. Water cannot run back to the sump when the pump is shut off because the top of the shaft is placed at a level slightly above the maximum water level in the channel. In this case the pump is placed in a steel column with a collar that rests on a supporting frame. Steel work is marginally more expensive, but civil construction costs are somewhat lower. If the water level on the outlet side of the pump varies considerably, flap valves can be installed. Normally the pump works against the head in the discharge channel or basin; when the pump is not in operation, the water is prevented from running back to the sump by the automatic closure of the valve. In this way, the pump always operates against the minimum head. The discharge elbow is used because of its low losses and comparatively simple construction. If odours require a closed system, this arrangement can be used with either a free discharge, as shown, or with a flap valve. In either case, a cover can be so placed as to prevent any overflow. If the pump is to work in combination with a siphon or a discharge line, a pressure-tight discharge elbow must be used. The elbow recommended here permits both fast installation and easy retrieval of the pumps.

PL/LL PUMPS PL/LL 4 LL PERFORMANCE FIELDS SUPERSEDES ISSUED Use for pre-selection only. 1 1 33 317 31 31 38 31 1 3 4 Flow, l/s 3 1 336 34 331 36 1 1 Flow, l/s The LL-3 series Vertical Mixed Flow Pumps were developed for the pumping of small to large volumes of raw water for use in marine pumping applications, secondary and final treatment plant effluent, storm water, amusement park water rides and any application where low to medium head pumping of clean, raw or partially contaminated water is required.

The basic design of the LL-3 series pump is a combination of the standard line of ITT Flygt heavy duty electric submersible motor units coupled with solids handling, mixed-flow impellers which utilize a diffuser having three or more guide vanes to stabilize the discharge flow. This diffuser is used in lieu of a centrifugal pump volute. PL/LL PUMPS PL/LL LL CHARACTERISTICS SUPERSEDES ISSUED 1/99 The LL-3 series mixed-flow pump is installed simply lowering the one piece motor/pump unit into its discharge column pipe and onto the pump mounting plate. The weight of the motor/pump unit firmly seats the pump to its mounting plate. LL NON-CLOG MIXED FLOW IMPELLER PERMANENT INSTALLATION IN A VERTICAL DISCHARGE COLUMN Model Horsepower LL-38 3. LL-31 LL-317 7.4-1 LL-31 14 LL-31 3 LL-33 4-6 LL-336 7-31 LL-34 3-3 LL-331 7-6 LL-36 9-6

PL/LL PUMPS PL/LL 6 LL TYPICAL INSTALLATIONS SUPERSEDES ISSUED ACCESS DOOR CONTROL PANEL CONTROL PANEL PRE-CAST R.C. PIPE LEVEL EQUIPMENT LEVEL EQUIPMENT STEEL INSERT RETAINING RING MESH SCREEN WITH " x " OPENINGS Steel Tube Installation Concrete Installation Contact your nearest ITT Flygt representative for additional information.