Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Similar documents
Hazardous Area Zirconia Oxygen Systems

Electromagnetic Flowmeters

Zirconia Oxygen Analyzer

Zirconia Oxygen Analyzer

Operating Guide IM/C1900-OGR Rev. J. C1900 Series Circular Chart Recorders

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

instrumentation Hydrogen Analyzer Systems Unrivaled safety and technical expertise from the market leader in hydrogen measurement

COMMANDER 1900 Series Circular Chart Recorders. Operating Guide. Recorder Versions COMMANDER deg F ABB Instrumentation

Low Temperature Zirconia Oxygen Analyzer

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

4600 Series Operating Instructions. Models 4623 and 4628 Conductivity Transmitters To Meet United States Pharmacopœia (USP 23) Regulations

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

DB5 Intrinsically Safe Sounder Type DB-5

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

EXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics

An Introduction to KC Controls Ltd

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

COMMANDER 150. User Guide Universal Process Indicator A1

VERSAFLOW VORTEX Supplementary instructions

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Survey of electrical equipment installed in hazardous areas on tankers

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

4) Intrinsic Safety Certification

INSTRUCTION MANUAL (ATEX / IECEx)

Zirconia Oxygen Probe

RFM Series RFM-ISR Barrier. Installation Manual

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Approved by: Document no.: EGT

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

SET Installation and Operating Instructions. Level switch for one sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Annubar Flowmeter Series

Dräger Polytron 5700 IR Detection of flammable gases and vapours

OPTIBAR DP 7060 Supplementary Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Intrinsically Safe Solutions

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Quick Start Guide For the

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

SET-2000 Hi Level/Oil

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Universal Tank Alarm Type Installation, Operation & Maintenance

Manual for QX0201 Push Button

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Sieger Apex. Flexibility that meets your requirements

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

LC2200 Level Controller Installation and Maintenance Instructions

Inductive slot sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

RT FLOW RATE TOTALISER

SIMRAD GD10 IR GAS DETECTOR

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Intrinsically Safe Flame Detector Installation Guide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

OilSET-1000 (12 VDC)

Size and rating wise typical Third Party Inspection certificates for the models of Valves

Electrical Installations Design, Selection, Erection and Inspection

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

Manual Power relay SR853

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Analyze IT Monitors for Organic Pollution, Surrogate Color, THM Precursor Measurement and Coagulation Control

IECEx Certificate of Conformity

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

OPTIWAVE X500 Supplementary Instructions

14300 MAINS SEPARATOR ALARM MANUAL

Model 144H. Product Data Sheet , Rev DB February Content

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

BA374C Intrinsically safe field mounting indicating temperature transmitter

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Technical Manual for the Alarm Pull Station PH1

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

IECEx Certificate of Conformity

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Dräger Polytron 5720 IR Detection of carbon dioxide

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

INSTRUCTION MANUAL (ATEX)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Transcription:

EXGP Oxygen Analyzer System (ATEX) Installation Guide Interface Electronics Unit DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS

ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. BS EN ISO 9001 RE GISTERED Cert. No. Q5907 EN 29001 (ISO 9001) Lenno, Italy Cert. No. 9/90A The NAMAS Calibration Laboratory No. 0255 is just one of the ten flow calibration plants operated by the Company, and is indicative of our dedication to quality and accuracy. 0255 Stonehouse, U.K. Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Note. Clarification of an instruction or additional information. Caution. An instruction that draws attention to the risk of damage to the product, process or surroundings. Information. Further reference for more detailed information or technical details. Although Warning hazards are related to personal injury, and Caution hazards are associated with equipment or property damage, it must be understood that operation of damaged equipment could, under certain operational conditions, result in degraded process system performance leading to personal injury or death. Therefore, comply fully with all Warning and Caution notices. Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of the Marketing Communications Department. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

CONTENTS 1 INTRODUCTION Section Page 1 INTRODUCTION... 1 1.1 Documentation... 1 1.2 Certification... 1 1.3 System Hardware... 2 2 PREPARATION... 3 2.1 Checking the Code Number... 3 3 MECHANICAL INSTALLATION... 4 3.1 Siting Requirements... 4 3.2 Mounting... 5 4 ELECTRICAL INSTALLATION... 6 4.1 Cable and Gland Specifications... 6 4.2 Access to Terminals... 7 4.3 Zener Barriers... 8 4.4 Cable Routing... 9 4.5 Electrical Connections... 10 4.6 Selecting Mains Voltage... 11 4.7 Re-sealing the Cover after Connection... 12 4.8 Switching Power On... 12 4.9 System Calibration... 12 1.1 Documentation Fig. 1.1 Documentation for the EXGP Oxygen Analyzer System is shown in Fig. 1.1. 1.2 Certification The Interface Electronics Unit is certified to the ATEX Directive and CENELEC Standards BS EN50014 and BS EN50018 flameproof II 2G EEx d IIB T6 (Baseefa03ATEX0384). Certificates and drawings are available for inspection and/or copies can be obtained on application to the Company. INTERFACE UNIT Certification Product Identification Mechanical Installation Electrical Installation Part No. IM/EXGP INT TRANSMITTER Product Identification Mechanical Installation Electrical Connections Controls & Displays Operation Programming Part No. IM/EXGP 4600 PROBE Product Identification Mechanical Installation Connections Fault Finding Part No. IM/EXGP PB SPECIFICATION SHEET Full Specification Part No. SS/EXGP Fig. 1.1 System Documentation 1

1 INTRODUCTION 1.3 System Hardware Fig. 1.2 The Interface Electronics Unit is an explosion proof wall-mounted unit with no external user controls. The unit has been designed for use in an area in which explosive atmospheres are present in quantities that require special precautions for the construction and use of electrical apparatus. The unit converts two intrinsically safe mv input signals from an EXGP probe (connected via zener barriers) into two ma output signals for retransmission to a 4680 or 4685 Series transmitter. The unit can only be connected to a EXGP Probe see Section 4 of the Probe Guide. HAZARDOUS AREA (ATEX Zone 1, Gas Group IIB) NON HAZARDOUS AREA Flameproof Interface Electronics Unit Certified to the ATEX Directive and CENELEC Standards BS EN50014 and BS EN50018 flameproof II 2G EEx d IIB T6 4680 Transmitter 4685 Transmitter or Flue Process 600 C to 1400 C (1250 C continuous) EXGP Probe Simple Device Conforming to BS5345 Part 4: 1977 Retransmission Output Mains Supply Reference Air Line Entry or R Type Thermocouple mv Signal (0 to 1400 C) Two 4 to 20mA Output Signals (0 to 1400 C and 0.25 to 25%O 2 ) Mains Supply O 2 mv Signal ( 20 to +180mV) I.S. Cabling Regulated Reference Air Unit (003000241) Mains Powered Pump Unit (003000240) or Mains Supply Fig. 1.2 System Schematic 2

2 PREPARATION 2.1 Checking the Code Number Fig. 2.1 DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS TYPE: SERIAL No. Ltd. Stonehouse England GL10 3TA EXGP INTERFACE ELECTRONICS COVER SCREW GRADE A2 70 MINIMUM 1180 EXGP/0002x0 Year II 2G EEx d IIB T6 Baseefa03ATEX0384 Vin 230VAC Amax 200mA ZENER DIODE SAFTY BARRIERS FITTED INSIDE MANUFACTURER : MTL [EEx ia] IIC (T amb 60ºC) TYPE : 760cc BAS01ATEX7202 EXGP Interface Electronics Unit EXGP/000 X X X Electronics Mains Supply For EXGP Probes 2 230V 115V 1 2 Alarms Not Fitted 0 Fig. 2.1 Checking the Code Number 3

DO NOT OPEN WHEN FLAMMABLE DO NOT OPEN WHEN FLAMMABLE DO NOT OPEN WHEN FLAMMABLE DO NOT OPEN WHEN FLAMMABLE 3 MECHANICAL INSTALLATION 3.1 Siting Requirements Fig. 3.1 Caution. When siting the Interface Electronics Unit choose a location free from excessive vibration. Maximum Distance 230ft (70m) A Maximum Distance of Interface Electronics Unit to EXGP Probe Maximum Distance 3281ft (1000m) B Maximum Distance of Interface Electronics Unit to 4600 Transmitter Unit 40 C Max. IP66 20 C Min. (NEMA 4X) C Within Temperature Limits D Within Environmental Limits Caution. 40 C is the certified maximum ambient temperature. Fig. 3.1 Siting Requirements 4

3 MECHANICAL INSTALLATION 3.2 Mounting Figs. 3.2 and 3.3 Warning. Installation and repair must only be carried out by the manufacturer, authorized agents or persons conversant with the construction standards for hazardous area certified equipment. D 6.69 (170) 14.37 (365) DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS 6.02 (153) 16.14 (410) 2.18 (55.5) 2.55 (65) 2.55 2.18 (65) (55.5) 11.81 (300) Min. Distance (For Door Clearance) 14.96 (380) Fig. 3.2 Overall Dimensions Information. It is preferable to mount the box at a level which allows easy access for connection and disconnection. 2 Drill suitable holes 1 Mark fixing centres (see Fig. 3.2) DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS Fix instrument to wall using suitable fixings ( 1 / 2 in or M12) 3 Fig. 3.3 Mounting 5

4 ELECTRICAL INSTALLATION Warning. Mains Power Before making any connections, ensure that the power supply, any high voltage-operated control circuits and high common mode voltages are switched off. 4.1 Cable and Gland Specifications Caution. Installation and repair must only be carried out by the manufacturer, authorized agents or persons conversant with the construction standards for hazardous area certified equipment. The specifications detailed in Table 4.1 are for system electrical requirements only. The Capacitance and Inductance or Inductance to Resistance (L/R) ratio of the cables connected to the output (hazardous area terminals) of the zener barriers mounted in the EXGP Interface Electronics Unit must not exceed the values detailed in Table 4.1. All cables must be suitable for flameproof 'd' type enclosures for mechanical construction. Glands used on the Interface Electronics Unit must be certified flameproof EEx d 'Barrier Gland' type. 4.1.1 EXGP Probe to Interface Electronics Unit Table 4.1 G land Specification - Probe Cable Specification (Intrinsically Safe Signals) Gland Specification - Interface Unit M16 Non-certified M16 Non-certified R Type Thermocouple (mv) Input: 16/0.2, 2-core, overall screened, R-type thermocouple compensating cable, conforming to BS4937. C apacitance 3µ f, Inductance 0.20mH, L/R Ratio 28µ H/ Ω Oxygen (mv) Input: 16/0.2, 2-core copper, overall screened C apacitance 3µ f, Inductance 0.20mH, L/R Ratio 28µ H/ Ω M20 flameproof certified barrier gland 'd' M20 flameproof certified barrier gland 'd' Table 4.1 Cable and Gland Specifications (electrical requirements only) 6

4 ELECTRICAL INSTALLATION 4.1.2 Interface Electronics Unit to Transmitter Table 4.2 4680 4685 or G land Specification Interface Cable Specification (EEx d Signals) Gland Specification Transmitter M20 flameproof gland 'd' certified barrier Retransmission (ma) Output Signals (Oxygen and Temperature): 16/0.2, 4-core 2TP copper, overall screen, flameproof. (Not supplied) NB: max loop resistance 750Ω. 4680: M20 Uncertified (fitted) 4685: No gland required M20 flameproof gland 'd' certified barrier 4.2 Access to Terminals Fig. 4.1 Mains Power Supply: 3-core, 0.5mm copper (min.) (Not supplied) 4680: M20 Uncertified (fitted) 4685: No gland required Table 4.2 Cable and Gland Specifications (electrical requirements only) 1 Remove flange bolts (16) 2 Insert bolt from underside of flange and screw in to break the seal between the lid and the base DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS Warning. The flange faces are flameproof paths and must be free from damage. If faces are damaged in any way the Interface Electronics Unit must be returned to the manufacturer for replacement. DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS Fig. 4.1 Access to Terminals 3 Open casing 7

4 ELECTRICAL INSTALLATION 4.3 Zener Barriers Fig. 4.2 The two zener barriers fitted to the unit are identified by a label positioned under the barrier see Fig. 4.2. Warning. Always refer to the label for correct orientation and re-connection if a new zener barrier is fitted. NON I.S. TERMINALS SAFE AREA TERMINALS 1 2 1 2 MTL 760ac SHUNT DIODE SAFETY BARRIER MTL 760ac SHUNT DIODE SAFETY BARRIER 3 4 3 4 HAZARDOUS AREA TERMINALS I.S. TERMINALS Fig. 4.2 Zener Barrier Identification Label 8

4 ELECTRICAL INSTALLATION 4.4 Cable Routing Fig. 4.3 I.S. CABLES I.S. Earth Screen Leads Power Supply Earth (Ground) I.S. Cabling Non-I.S. Cabling Caution. Clip the I.S. cabling away from other cabling. Fig. 4.3 Cable Routing 9

4 ELECTRICAL INSTALLATION 4.5 Electrical Connections Fig. 4.4 Warning. The power supply earth (ground) must be connected to ensure safety to personnel and reduction of the effects of radio frequency interference (RFI). Connect the power supply earth (ground) lead directly to the case earth stud and not to the 'E' terminal. Earth Studs E TB5 TB4 TB1 + + E L N Cell Output (4 to 20mA) Temperature Output (4 to 20mA) Power Supply Earth Busbar Zenner Barrier EXGP Probe Leads Screen Connections Intrinsically Safe Signals from EXGP Probe + Probe Temperature Thermocouple + Cell Output mv Fig. 4.4 Electrical Connections 10

4 ELECTRICAL INSTALLATION 4.6 Selecting Mains Voltage Fig. 4.5 115 2 115V 115 1 230V 230 0 Power Supply not Fitted Code Label see Fig. 2.1 TYPE: SERIAL No. Ltd. Stonehouse England GL10 3TA EXGP INTERFACE ELECTRONICS COVER SCREW GRADE A2 70 MINIMUM 1180 EXGP/0002x0 Year II 2G EEx d IIB T6 Baseefa03ATEX0384 Vin 230VAC Amax 200mA ZENER DIODE SAFTY BARRIERS FITTED INSIDE MANUFACTURER : MTL [EEx ia] IIC (T amb 60ºC) TYPE : 760cc BAS01ATEX7202 Fig. 4.5 Selecting Mains Voltage 11

4 ELECTRICAL INSTALLATION 4.7 Re-sealing the Cover after Connection Fig. 4.6 Warning. Ensure all electrical connections have been made correctly before re-sealing and securing the cover. Do not switch on mains power until the cover has been re-sealed and secured with all 16 (SS Grade A2 70) cover bolts tightened evenly to approx. 10Nm. There should be no visible gap in the joint between lid and base. If in doubt check that a 0.20mm feeler gauge does not fit into the gap at any point. 5 Insert and tighten flange bolts to approximately 10Nm 1 Remove bolt from rear of casing 2 Apply grease (part no. CG5317) to flange DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS DO NOT OPEN WHEN ENERGISED OR WHEN AN EXPLOSIVE GAS 4 Ensure witness around entire flange 3 Close casing Fig. 4.6 Securing the Cover 4.8 Switching Power On Information. Ensure the Probe has been installed and connected correctly see Sections 3 and 6 of the Probe Guide. If a 4680 or 4685 Transmitter unit is used,ensure that it has been installed and connected correctly as detailed in Sections 3 and 4 of thetransmitter Guide. Before switching the transmitter on, refer to Section 5 for Controls and Displays and Section 6 for Instrument Start-up. The interface unit has no independent ON/OFF switch and must be powered-up from the mains switch. 4.9 System Calibration The interface unit is calibrated from the transmitter see Section 7 of the Transmitter Guide for system calibration. For other transmitters refer to the relevant instruction manual supplied with the instrument. If a fault is suspected, calibrate the unit as detailed in the Electrical Calibration Supplement. If the fault persists, return the unit to the Company. 12

PRODUCTS & CUSTOMER SUPPORT Products Automation Systems for the following industries: Chemical & Pharmaceutical Food & Beverage Manufacturing Metals and Minerals Oil, Gas & Petrochemical Pulp and Paper Drives and Motors AC and DC Drives, AC and DC Machines, AC motors to 1kV Drive systems Force Measurement Servo Drives Customer Support We provide a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United Kingdom ABB Limited Tel: +44 (0)1480 826 661 Fax: +44 (0)1480 827 856 United States of America ABB Inc. Tel: +1 215 674 6000 Fax: +1 215 674 7183 Controllers & Recorders Single and Multi-loop Controllers Circular Chart, Strip Chart and Paperless Recorders Paperless Recorders Process Indicators Flexible Automation Industrial Robots and Robot Systems Flow Measurement Electromagnetic Magnetic Flowmeters Mass Flow Meters Turbine Flowmeters Wedge Flow Elements Marine Systems & Turbochargers Electrical Systems Marine Equipment Offshore Retrofit and Referbishment Process Analytics Process Gas Analysis Systems Integration Transmitters Pressure Temperature Level Interface Modules Valves, Actuators and Positioners Control Valves Actuators Positioners Water, Gas & Industrial Analytics Instrumentation ph, conductivity, and dissolved oxygen transmitters and sensors ammonia, nitrate, phosphate, silica, sodium, chloride, fluoride, dissolved oxygen and hydrazine analyzers. Zirconia oxygen analyzers, katharometers, hydrogen purity and purge-gas monitors, thermal conductivity. Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: 1. A listing evidencing process operation and alarm logs at time of failure. 2. Copies of operating and maintenance records relating to the alleged faulty unit.

ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the UK (09.03) ABB 2003 IM/EXGP INT Issue 4 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 827856 ABB Inc. 2175 Lockheed Way Carson City, NV 89706 USA Tel: +1 775 883 4366 Fax: +1 775 883 4373