Optical benefits associated with PrismaLED technology. Enhanced Lumen Maintenance due to self cleaning design. Patented design delivering genuine solution for new and retrofit solutions to replace 400W HID. Delivers a system life of 100,000 hours. Value Proposition
Rail Logistics Sports Retail Exhibition Halls Application
Prismatic Glass Optics Thermal Shock Longevity UV Impervious Recyclable Temp Resistance Chemical Resistance Low Dirt Accumulation
Why Glass?
Lumen Maintenance
Optical Performance Discomfort Glare Colour Consistency Minimising LED Failure Maximising Optical Control
Optical Performance Broad Distribution 1.2:1 to 1.7:1 Extensive Distribution 1.7:1 to 2.2:1 Intensive Distribution 0.9:1 to 1.2:1 Focused Distribution 0.7:1 to 0.9:1
System Longevity System Life of over 100,000 hours at L70F10.
Product Specification 70CRI or 80CRI options available. Lumen packages ranging from 20,000 to 39,000 with efficacies of 101 lpw. IP20 luminaire with IP65 optical chamber. TA -20 o C to +45 o C. Wire guard and safety chain attachment options. Single or Twin Suspension.
Emergency No emergency kit available with the power to run the LED s. Limited space within the luminaire.
Three hours non-maintained emergency solution. EMCA Recap Emergency ballast with DALI as standard and integrated battery pack (12V/340mA) Emergency indicator built into cover plate. Safety chain attachment included as standard.
Performance Data Product Code Drive Current (ma) Lumens + Power Consumption (W)* Luminaire Performance (LPW) Power Factor (Ø) HAL.L3947 700mA c.38500 385 100 TBC HAL.L3247 700mA c.31869 308 103 TBC HAL.L2247 700mA c.22106 230 94 TBC HAL.L3448 700mA c.34000 385 89 TBC HAL.L2748 700mA c.27000 308 87 TBC HAL.L2048 700mA c.20000 235 85 TBC * Subject to final testing +Dependent on distribution.
Life (000's) 100 System LED 90 Performance Data Estimated system rated life of 100,000 hrs L70F10 @ TA 25 o C. LED life of >100,000 hours 80 70 60 50 40 25oC 35oC 40oC 45oC Ambient Temp
New Build Performance Example Parameters Dirty environment Reflectance s C50%, W30%, F10% Room dimensions (m): Length: 50, Width: 30, Height: 9. Luminaire Installation height of 9m. Total area 450m 2 Target Lux : 500, Uniformity : >0.60 as per BSEN12464-1 2011 45 luminaires 28 luminaires
Retrofit Performance Example HALOPRISM Retrofit 50 HALOPRISM high bay luminaires Luminous flux: c24,000 lm Luminous efficiency: 102 lm/w Existing Luminaires 84 400W HIE High bay luminaire Luminous flux: 32,500 lm Luminous efficiency: 75 lm/w or 50 6x80 Whitecroft Fluorescent Luminous flux: 39300 lm Luminous efficiency: 74 lm/w
Choosing replacement method Retrofit One-for-One replacement Optimised replacement
Using the right Maintenance Factor for every application Retrofit Lamp Lumen Maintenance Factor Room Surface Maintenance Factor MF = LLMF LMF RSMF Luminaire Maintenance Factor Every installation has MF 1 (100%) at time 00:00 MF can emphasize the importance of a quality, long lasting luminaire MF affects the quantities of the luminaires, especially when there is high depreciation. The MF used by competitor should be known and validated. MF LLMF LMF (10000 RSMF ( 2yrs hours) cleaning) Haloprism 0.91 1 0.97 0.94 Gentlespace 0.81 1 0.86 0.94 Durosite 0.81 1 0.86 0.94 Litex 0.81 1 0.86 0.94 Cooper high bay 0.74 1 0.79 0.94 Zumtobel Graf 0.81 1 0.86 0.94 PLS HTPSP 0.73 0.92 0.982 0.81 PPS HTPSP 0.85 0.92 0.982 0.94 I-Beam 0.81 1 0.86 0.94 Proteon 0.81 1 0.86 0.94 T5 80W 0.50 0.9 0.59 0.94 HIE 400W (magnetic) 0.37 0.66 0.59 0.94
Controlling Haloprism DALI controlled 1. Well established protocol in the market 2. Compatible with any standard DALI system 3. No necessity for a bespoke control solution unless required 4. 3 addresses / luminaire more demanding wiring and commissioning. 5. The design must be always assessed from a controls point of view before giving budget cost. 6. Any last minute changes should always be reported to verify they are within the control system s potential. 7. Avoid frequent on/off switching. 8. A single driver model will be released in the near future (currently being tested)
Amortisation on Retrofit Installation Including luminaire and running cost Performance
Amortisation on Retrofit Installation Including luminaire and running cost Exceptional vertical illumination Improved Light Control Better Uniformity Low Glare = Performance Increase in task performance Reduction in number of rejects Accident Reduction
Controls Analogue Fast Dim 1-10V (.ANF). DALI control (3 x DALI addresses) Constant Lumen Output 70%, 80% & 90% maintaining 50% of the LED light engines or LED s. Standalone high-bay analogue presence detector PIR kit for 360 o and aisle. HEL.PIR
Key Competitors
Key Competitors Product Lumen Range LPW CRI Lifetime @ L70 Ta IP Rating Controls Option DALI/1-10V 12,600 28,000 90-100 70 & 80 50,000 TBC IP65 DALI 11,000-25,000 80-102 70 100000-40 o C to 65 o C IP66 No 10,000-24,000 82 93 75 75,000-30 o C to 45 o C IP65 DALI 10,300 20,700 95-105 75 50,000-30 o C to 40 o C IP65 DALI 20,000 39,000 85-101 70 & 80 100000-20 o C to 45 o C IP20/ IP65 (optic) DALI and 1-10V
Product Positioning
Product Positioning - Unique prismatic glass lens with LED technology - PrismaLED. - Highest lumen package available. - Advanced lumen Maintenance. - Thermal management delivers a system life of 100,000. - Sealed optical chamber. - Premium MIRO Silver reflector system - Dynamic temperature sensing and control. - Pluggable and removable driver tray. - Luminaire designed to conduct and convect heat. - 25,000 hours system life. - Passive convective cooling - Light weight and rigid construction - Direct replacement for fluorescent luminaires - 100,000 system life but limited lumen maintenance
Marketing Support
Marketing Support