Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Similar documents
A Guide to Commercial Hot Water from Hamworthy. Introducing Hamworthy s Product Ranges for Hot Water Generation:

Hamworthy. Powerstock. Calorifiers and Storage Tanks Single and Twin Coils Capacities 160 litres to 995 litres

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

Hamworthy Dorchester DR-FC Evo 98%

CI/Sfb. (53.5) Xh. March Conventional Flue Fan Flued Balanced Flue Direct Storage Tanks

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Knight & Charger Water Heaters

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Powerstock Storage Tank

Copper-Fin GAS-FIRED WATER HEATERS

LBF RANGE BALANCED FLUED WATER HEATERS

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

Hoval Cosmo Combination boilers. High efficiency heating combined with economic DHW generation. Boiler outputs from 100 to 1450kW.

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

INSTALLATION AND USER INSTRUCTIONS

Installation, Operating and Servicing Instructions

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Dovre 250 Cast Iron Gas Stove

Hamworthy. Fleet Wall Hung. Condensing Boilers Natural Gas Outputs 40kW to 150kW 5 YEAR HEAT EXCHANGER WARRANTY

Baxi Maxflow Combi WM

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

INSTALLATION GUIDE, OPERATION AND SERVICE MANUAL

Hamworthy Fleet Vertical Floor Standing. Condensing Boilers Natural Gas Outputs 80kW to 1050kW 5 YEAR HEAT EXCHANGER WARRANTY

BFM Balanced flue commercial water heater

Installation and Servicing Instructions. Alpha GasSaver GS-1

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Installation & Technical Guide. Domestic & Commercial.

1 VICTRIX ZEUS Superior kw I features

Sirius FS. Working towards a cleaner future

Sirius WH. Working towards a cleaner future

Multipoint Technical Data

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Baxi Maxflow Combi FS

Owner s Guide and Installation Instructions

MAX O GAZ. Condensing water heater TECHNICAL MANUAL

ADMP. Commercial Atmospheric Water Heater ADM - 40/50/60/80/90/115. Installation, User and Service Manual. Innovation has a name.

BFC Cyclone Condensing Glass-Lined Water Heater

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Installation and Servicing Instructions. Alpha FlowSmart

The iqe Boiler Range. Combination and System T Boilers.


Hotflo. Unvented point of use hot water

Hamworthy. Purewell VariHeat

FASTflo. Working towards a cleaner future

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Light commercial products. High output boilers Cascade systems

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

INSTALLATION AND MANINTENANCE INSTRUCTIONS

MODEL BTI 65 G InsTALLATIOn AnD user InsTRucTIOn united kingdom / IRELAnD HOT WATER storage HEATER

Combined electric boiler and domestic hot water store

Knight. Installation, Commissioning, User & Maintenance Instructions. Traditionally Gas Fired Single Flue Water Heater with Pilot Ignition

SPECIFICATIONS - NIKE

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

SECTION 1 - INSTALLATION UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER 1.1 MODE

CLASSICflo Fan Flued range Gas fired, fan flued storage water heaters for natural gas Models RFF 13/175 and RFF 18/270

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

Warmth, efficiency, and total peace of mind.

Installation and Servicing Instructions. Alpha CB50

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

Owner s Guide and Installation Instructions Gas Domestic Indoor Water Heater

Technical Data Manual Model Nos. and pricing: see Price List

ENERGY TOP. Condensing boiler solutions

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Hamworthy. Wessex Modumax. High Efficiency, Fully Modulating Boilers Condensing & Non Condensing, Pre-mix, Gas Fired. Outputs 100kW to 750kW

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Installation and Servicing Instructions. Alpha GasSaver GS-2

Stored Water District Heating Interface Units. Heat Interface Units

Charger range. the Knight & Technical Specification. Our conventionally flued gas fired storage water heaters.

kw Btu/h Metres Feet l/min. Gal/min C C

RAYPAK HOT WATER & HEATING

Water Heating Systems

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

INSTALLATION - AND USER INSTRUCTIONS

Knight Gas Fired Single Flue Water Heater with Pilot Ignition

95% Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular Boilers. Wessex ModuMax mk3. New. Restyled with latest Siemens controls


AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

Powerstock - Storage Tank Range

Installation, Operating and Servicing Instructions

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

Andrews Water Heaters

Broag Pressurisation equipment

Transcription:

Exceeds Minimum Requirements Hamworthy Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters 18.9 kw to 20.1 kw, Natural Gas or LPG Continuous outputs 369 l/h to 392 l/h

Single Fire Tube, Direct Gas-Fired Storage Water Heaters The Hamworthy Dorchester DR-S storage water heaters offer a practical and efficient means of producing domestic hot water and are suitable for smaller commercial applications requiring a maximum continuous output of up to 392 litres/hour. These single fire tube gas-fired water heaters are available with a choice of fully automatic ignition in the DR-SA range or permanent pilot ignition in the DR-SE range. Both ranges have the same atmospheric burners and very similar water storage tanks. Each range offers two equivalent models and these can provide maximum continuous outputs of 369 litres/hour and 392 litres/hour, based on a 44ºC temperature rise. For the Dorchester DR-SA and DR-SE respectively, storage capacities are 278 litres and 372 litres and maximum output powers are 18.9 kw and 20.1 kw using natural gas, or 17.6 kw and 19.1 kw using LPG. The DR-SA and DR-SE water heaters are the smallest in the Hamworthy Dorchester range, with straight forward controls for ease and simplicity of operation; and yet built to the same exacting high standards as all other water heaters in the Hamworthy Dorchester family for the safe production of potable domestic hot water (DHW). If no electrically-powered options are specified, the Dorchester DR-SE models can be operated without a power supply in their basic form, as they use a piezo ignition and thermocouple-type safety controls. This means they can be an ideal choice for use in applications such as campsites and temporary buildings, and wherever access to a mains power supply may be limited. Options Natural gas or LPG Unvented supply kit Top-to-bottom pump recirculation kit Flexible replacement magnesium anodes Electrical anode protection Time clock control kit (DR-SE only) Exceeds Part L minimum requirements Magnesium sacrificial anode for corrosion protection Clean out door for easy maintenance Simple operation DR-SE can operate without power supply Ideal for close to point-of-use small commercial applications and, in the case of the Dorchester DR-SE, can be used without a mains power supply. Dorchester DR-SA automatic ignition direct-fired water heater in a plant room BENEFITS 2

Typical Layout Dorchester DR-SA Draught diverter Hot water outlet Cold-water inlet (c/w inlet tube) Combustion products discharge safety device T&P valve connection Steel cylinder Outer casing Insulation Baffle Single fire tube Vitreous enamel coating on water-side surfaces Magnesium anode Gas control valve Control panel (DR-SA only) Clean out door Drain valve and secondary return connection Atmospheric burner Intermittent pilot burner and flame probe (DR-SA only) Dorchester DR-SE Lower cylinder and ignition system detail Gas control valve Drain valve and secondary return connection Permanent pilot burner and thermocouple (DR-SE only) Atmospheric burner 3

Specification The Dorchester DR-SA is the automatic ignition variant and includes a fully electronic gas valve, spark ignition system, control and high limit thermostats, safety thermostat and lockout indicator light and reset button. A further thermostat is located on the draught diverter as a combustion products discharge safety device, to detect flue gas spillage and to shut down the burner in the event of a down draught condition. The Dorchester DR-SE is the permanent pilot variant based on the Dorchester DR-SA but with self-energised controls and a permanent pilot ignition system. The Dorchester DR-S range of water heaters are manufactured to the highest standards using the latest production technology to ensure a high quality long lasting finish in every product configuration. Compliance is assured with stringent controls in accordance with the European Standards and each model carrying the CE mark for compliance with the European standard BS EN 89:2000. All Dorchester DR-S models exceed the minimum efficiency requirements of the Building Regulations, Part L, and each is designed to meet the latest HSC requirements for the control of Legionellosis. a a Water Heater Construction The water heater cylinders are constructed from high grade steel and given a high quality vitreous enamel coating. The fabrication of the cylinder and welding is completed fully before the enamel is applied, ensuring that the integrity of the coating is not affected during manufacture. During enamelling, the cylinder and associated heat exchanger fire tube undergo a precise glass coating process where the unit is rotated in every direction to ensure an even glaze is applied throughout. Surplus material is drained before the unit is then baked at 840ºC to complete the adhesion of the glaze to water-side surfaces of the cylinder and heat exchanger fire tube, providing a long lasting, hygienic and corrosion resistant finish. The cylinder is covered with a 50 mm layer of CFC-free foam insulation to ensure that standing losses are kept to a minimum. Burner The atmospheric burner is a single, stainless steel, annular burner mounted at the base of the cylinder and draws air in naturally (no fan) in the space under the unit, which must be kept clear. Heat Exchanger and Flue Connection The heat exchanger has a single vertical fire tube which is fitted with steel baffles in order to maximise the heat transfer. The fire tube exits the cylinder through a draught diverter for connection to a flue system. Fully Automatic Ignition (DR-SA) Dorchester DR-SA models are equipped with a fully automatic ignition system. An electronic soft start gas valve and spark electrode ensures reliable burner operation. If the flame is not established within the safety period, the controller locks out and must be reset manually. Permanent Pilot Ignition (DR-SE) Dorchester DR-SE models are equipped with a permanent pilot ignition system with automatic gas valve and safety pilot which is monitored by means of a thermocouple device. A piezo spark device is fitted to provide ignition for the pilot flame. Inspection and Clean Out Door The Dorchester DR-S models have an easily accessible clean out door that allows for the inspection and cleaning of the tank's interior, as required by the recommendations of the HSC for the control of Legionellosis, including Legionnaires disease, along with suitable tappings to facilitate an optional top-to-bottom recirculation kit. Dorchester DR-SA cutaway with covers removed, showing fire tube and baffles, anode, clean out door and annular burner Open Vented or Unvented Water Supplies The water heaters are suitable for open vented water supplies but can also be used with unvented water supplies using an optional unvented supply kit. 4

Specification Unvented Supply Kit (Optional) All Dorchester water heaters are suitable for installation in direct unvented water supply systems when installed with the optional unvented supply kit. The expansion vessel included in the kit is sized for the water heater and local pipe work only, and should be re-sized if used on larger systems. The unvented supply kit allows the water heater to be fed directly from the mains water supply or from a booster pump set without the need for header tanks. The kit contains all of the additional parts required to satisfy the Water Supply (water fittings) Regulations 1999, including: Strainer Pressure reducing valve Isolating non-return valve Expansion relief valve Tundish 24 litre expansion vessel with wall bracket Pressure and temperature relief valve (which locates directly into the water heater). Temperature Control The outlet temperature of the heater is regulated by the control thermostat which is housed in the control panel. The operating temperature set point is adjustable from 40 C to 80 C (DR-SA) or 81 C (DR-SE). The high temperature limit setting is 90 C, at which point the unit will shut down and require manual reset. Time Clock Control, DR-SE only (Optional) Where there is a requirement for control by an external signal, such as from a time clock or safety interlocks, then an optional control kit can be fitted. The kit comprises a solenoid valve that fits between the control valve and the burner. The kit requires a 230V, 50Hz single phase power supply. Corrosion Protection: Magnesium Sacrificial Anodes DR-SE and DR-SA models are all fitted with removable magnesium sacrificial anodes as standard, ensuring excellent protection against corrosion. Clearance is required above the unit for maintenance and replacement of the magnesium sacrificial anodes. Flexible Replacement Magnesium Sacrificial Anodes (Optional) Flexible replacement magnesium anodes can be ordered as an option where clearance above the unit is restricted. The fixed anodes can be used from installation, and when in need of replacement, then the flexible anodes can be used. These sausage-shaped anodes comprise several small magnesium bars that are chain linked together. Electrical Anode Protection (Optional) In areas of the country with particularly soft water supplies having electrical conductivity less than 200 microsiemens, such as Scotland, Devon and Cornwall, magnesium sacrificial anodes may not be fully effective in providing protection against internal corrosion. The optional electrical protection replaces the magnesium sacrificial anodes and is effective in providing internal corrosion protection with water supplies having electrical conductivity levels as low as 125 microsiemens. It is essential for correct operation that an uninterrupted 24-hour power supply is maintained at all times to ensure proper protection of the unit. Electrical anode protection will be factory fitted where specified at the time of ordering. Top-to-Bottom Pump Recirculation Kit (Optional) In order to prevent stratification within the heater, thus creating a zone of lower temperature water that can possibly lead to the proliferation of Legionella bacteria, a top to bottom re-circulation kit should be specified. The top to bottom circulator should be controlled to run during the anti- Legionella purge cycle. Alternatively, by constantly returning water from the flow connection back into the base of the heater, a uniform temperature is maintained. The kit includes a pump, isolation valves, non-return valve and pipe work for fitting on site. Combustion Products Discharge Safety Device If a water heater is to be installed in a habitable area then it is a requirement of EN 89 that it be fitted with a device that detects the spillage of combustion products and shuts down the appliance. A habitable area includes kitchens, shower blocks, workshops or any other area that is occupied. A combustion products discharge safety device is fitted as standard on Dorchester DR-SA and DR-SE water heaters, and comprises a thermostat that is fitted to the rim of the draught diverter. In the event of flue gas spillage occurring due to down draught or lack of buoyancy in the flue system, the thermostat will shut down the heater. Fuel Options All Dorchester water heaters are suitable for both natural gas and LPG fuel. The fuel type must be specified at the time of ordering. It is strongly recommended that on LPG installations, gas detection equipment is fitted and that this equipment is positioned near the heater and at low level. It is also imperative that the plant room is ventilated at high and low level. The LPG variants of the Dorchester DR-SE and DR-SA must not be installed in basement plant rooms. Flue System The Dorchester DR-SA and DR-SE water heaters are suitable for B23 open flue applications. Although there are no dedicated flue terminals and flue components available for the Dorchester DR-SA and DR-SE water heater, we work in partnership with Midtherm Engineering to provide a comprehensive flue design and installation package for all of the Dorchester range of water heaters including the Dorchester DR-SA and DR-SE. Contact your Hamworthy Area Sales Manager about your bespoke flue requirements: Tel 0845 450 2865 Email sales@hamworthy-heating.com 5

Technical Data Specification Units Dorchester DR-SA/SE Model DR-SA 16 DR-SE 16 DR-SA 19 DR-SE 19 Continuous output with 44ºC ΔT l/h 369 392 Continuous output with 50ºC ΔT l/h 325 345 Continuous output with 55ºC ΔT l/h 295 314 Water Storage capacity litres 278 372 Maximum operating water pressure (open vented) bar 8 Maximum operating water pressure (unvented) bar 3.5 (=cold feed pressure reducing valve preset in unvented kit option) Expansion relief valve setting (open vented kit) bar 5 Building Regulations thermal efficiency gross % 76.54 Energy Heating-up time, ΔT = 44ºC min. 45 57 Heating-up time, ΔT = 50ºC min. 51 65 Heating-up time, ΔT = 55ºC min. 57 71 Standby losses kw/24h 11.3 n/a Gas Nat. Gas G20-20mbar LPG G31-37mbar Flue Input power, gross maximum kw 24.7 26.2 Output power maximum kw 18.9 20.1 Gas inlet pressure nominal mbar 20 Gas flow rate maximum@1013.25 mbar and 15ºC m³/h 2.4 2.5 Input power, gross/ (net) maximum kw 22.5 24.5 Output maximum kw 17.6 19.1 Gas inlet pressure nominal mbar 37 Gas flow rate maximum@1013.25 mbar and 15ºC kg/h 1.6 1.8 Approximate flue gas volume @15 C, 9.8% CO 2, N.T.P. (Nat. Gas-G20) m 3 /h 30.4 31.7 Flue gas temperature maximum C 275 Flue draught requirements mbar -0.125 Power consumption DR-SE (DR-SA) W 30 (0) General Electrical supply V AC 230 V 1 Ph 50 Hz Weight when empty kg 117 122 144 149 Approximate shipping weight kg 122 127 149 154 Maximum floor load/ weight filled with water kg 395 400 516 521 6

Dimensional Details Dimensions and Clearances Hot water outlet Cold water outlet Clean out door D 410 Temperature and pressure relief valve tapping 1000 410 500 410 500 F 2 1 F 2 1 N 375 210 R S B M A 210 340 L Clean out door Plan View DR-SA L Drain valve Plan View DR-SE Clearances: Allow minimum 1000 mm above water heater, 1000 mm around the controls and clean out doors and 500 mm around all other sides. Gas control valve Gas control valve Drain valve Front View DR-SE Part-Front View DR-SA All dimensions in mm Ref Dimensions Units Dorchester DR-SA/SE Model DR-SA 16 DR-SE 16 DR-SA 19 DR-SE 19 A Total height mm 1585 1780 B Cylinder height mm 1450 1640 D Water heater diameter mm 645 675 F Depth mm 770 735 775 765 L Gas control valve position mm 355 370 M Cold water inlet connection height/(size) mm/(inch) 1505 (1ʺ-11.5 NPT male) 1685 (1¼ʺ-11.5 NPT male) N Hot water outlet connection height/(size) mm/(inch) 1505 (1ʺ-11.5 NPT male) 1685 (1¼ʺ-11.5 NPT male) R Drain valve connection height/(size) mm/(inch) 285 (¾ʺ -14 NPT female) S T & P valve connection height/(size). mm/(inch) 1280 (¾ʺ -14 NPT female) 1460 (¾ʺ -14 NPT female) Gas inlet connection size inch Rp ½ʺ female Air Supply and Ventilation An adequate supply of fresh air for combustion and ventilation must be provided in accordance with BS5440 (<70 kw Net) and BS6644 (>70 kw Net). Air supply and ventilation must be sized for the entire plant, with calculations based on the combined net heat input of all gas fired appliances within the plant room or compartment. Compartment Ventilation Open Flue Direct to outside air High level 5 cm 2 /kw net input Low level 10 cm 2 /kw net input Plant Room Ventilation Open Flue Direct to outside air High level 2 cm 2 /kw net input Low level 4 cm 2 /kw net input 7

Hamworthy Heating Accreditations Customer Service Centre Hamworthy Heating Limited Fleets Corner, Poole, Dorset BH17 0HH ISO 9001 Quality Management System ISO 14001 Environmental Management System OHSAS 18001 Health & Safety Management System The printed version of this brochure is produced using environmentally friendly print solutions in partnership with our suppliers Telephone: 0845 450 2865 Email: sales@hamworthy-heating.com Web: www.hamworthy-heating.com Hamworthy reserves the right to make changes and improvements which may necessitate alteration to the specification without prior notice. Dorchester, Powerstock and Hamworthy are registered trademarks of Hamworthy Heating Limited. 500002630 A