CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

INDOOR COILS INDOOR COILS. Airflow Capacities 400 to 2,250 CFM [188.8 to L/s] FORM NO. C REV. 14 Supersedes Form No. C Rev.

Commercial High-Efficiency Condensing Units

13 SEER CONDENSING UNITS

HEAT PUMPS UPNL- FORM NO. P REV. 4 Supersedes Form No. P Rev. 3

16 SEER TWO-STAGE AIR CONDITIONERS

HEAT PUMPS UPNL- FORM NO. P REV. 5 Supersedes Form No. P Rev. 4

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

Commercial High-Efficiency Condensing Units

HEAT PUMPS Equipped with the Award Winning Comfort Control System RPNL- JEZ Six Models 13.0

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

14.5 SEER HEAT PUMPS. Featuring New Industry Standard R-410A Refrigerant 14PJM SERIES

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TZPL SERIES. Applications Thermal Zone remote heat pumps offer comfort and dependability for single, multi-family and light commercial applications.

2 shp 13 lc 1 36 t - 1 a

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL SPECIFICATIONS

MAC N-407 Air-Cooled Chiller

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MAC-120HE-03 Air-Cooled Chiller

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

AIR HANDLERS AIR HANDLERS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Rheem High Efficiency Air Handler

T P A 120 S 4 S N 1 Y

TECHNICAL SPECIFICATIONS

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

13 SEER CONDENSING UNITS

MERIT SERIES Up Flow / Horizontal

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Rheem High Efficiency Air Handler

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

PRODUCT SPECIFICATIONS

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Standard Efficiency Air Handler

MERIT Series R-410A - Upflow / Horizontal

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Rheem Commercial High-Efficiency Condensing Units

WCH5**4. Product Specifications

CWA4 Chilled & Hot Water Fan Coil

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

PAJ3. Product Specifications

MERIT Series R-410A - Upflow / Horizontal

R4H4. Product Specifications

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

R4H4. Product Specifications

Visit us at For the latest technical information,

HIGH EFFICIENCY AIR HANDLER

13 GEP A L P - 1 A

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Ruud Standard Efficiency Air Handler

Product Specifications. Vertical Floor Consoles By First Co.

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

N4H4. Product Specifications

HIGH EFFICIENCY AIR HANDLER

General Description. Operation

Transcription:

fit,/5, Bw %* FORM NO. A11-149 REV. 1 Supersedes Form No A11-149 Rev 0 Seven Models Cooling Capacities 19,500 to RAMA- SERIES Nominal Sizes 1 Vz to 5 Tons The Rheem ClassicXII Super High Efficiency RAMA- Condensing Unit was designed with performance in mind. These units offer comfort, energy conservation and dependability for single, multi-family and light commercial applications. The Rheem Classic XD RAMA- Condensing Units are the result of an ongoing development program for improved efficiencies. With 's ranging to 12.4, these units continue a tradilion of high efficiency Attractive, louvered wrap-around jacket protects the coil from yard hazards and weather extremes. Top grille is steel reinforced for extra strength. Cabinet Is powder painted for all-weather protection. Air is discharged upward away from bushes and shrubs. The discharge pattern of the top grille provides minimum air restriction, resulting in quiet fan operation. Exclusive Combination Grille/Motor Mount secures the motor to the underside o^ the discharge grille. The grille protects the motor windings and bearings from ram and snow All controls are accessible by removing one service panel. Removable top grille provides access to the condenser fan motor and condenser coil. Single speed motor designed for low speed, quiet. energy-saving operation 'CERTIFIED UNDER THE A R I CERTIFICATION PROGRAM A. R I STANDARD 210"

^ Sll*SI 1 -i - - * «V All controls and compressor are accessible for servicing by removal of the service panel y Drawn Painted Base Pan ">' Engineering Features RAMA- Series Condensing Units 1. Scroll compressor is hermetically sealed and incorporates interna! high temperature motor overload protection, and durable insulation on the motor windings It is internally spring mounted and externally mounted on rubber grommets to reduce vibration and noise. 2. Compressors have an internal pressure relief assembly to protect against excessive pressure differential. 3. All refrigerant connections are on the exterior of the unit, located close to the ground for neat appearing installations. 4. Cabinet is constructed of powder painted galvanized steel The full wraparound louvered grille protects the coil from damage 5. Copper Tube Aluminum Fin coils are used on all models 6. The control box is located in the top corner of the cabinet providing for easy access through a service panel. 7. Service valves are standard on all models. 8. Power and control wiring are kept separate. 9. Every unit is factory charged and tested. 10. Separate compressor compartment for easy service access. 11. Drawn, painted base pan for extra corrosion resistance and sound reduction 12. RAMA- Series has a 10 year compressor limited warranty, factory installed low pressure control, high pressure control, compressor sound enclosure, and a liquid line filter drier 13. Anti-Short cycle time delay control Field Installed Accessories Low Ambient Switch Cycles outdoor fan to maintain adequate condensing pressures assuring liquid refrigerant flow to the coil. Allows indoor cooling with outdoor temperatures down to 0 o F. (Model No RXAD-A04) It is recommended that this control be installed in units to be operated at outdoor ambient temperatures under 70 o F. W^, *"1, vi t COPELAND COMPLIANT SCROLL Copeland's new scroll compressor is the key to efficiency for this Rheem model It's the latest in high-efficiency compressor technology. The advanced compliant scroll compressor offers low noise and vibration characteristics and features tolerance to liquid refrigerant and system contamination The Copeland Compliant Scroll also has low start torque, eliminating start problems in the field. And its unique design enables the RAMA- condensing unit to perform more efficiently i, «ir Model Number Identification R M A 024 RHEEM CONDENSING UNIT TYPE-M SUPER Hl-EFFICIENCY DESIGN SERIES NOMINAL COOLING CAPACITY 018= 18,000 024 = 24,000 030 = 30,000 036 = 36,000 042 = 048 = 48,000 060 = 60,000 ELECTRICAL DESIGNATION J = 208/230-1-60 (SCROLL COMPRESSOR) COMPRESSOR) (SCROLL VARIATIONS A = DELUXE MODEL CONNECTION TYPE S = SWEAT

Table 1 Condensing Unit Refrigerant Tubing Data Model RAMA- 018 024 030 036 042 046 060 Factory Charge, Oz. 85 1 192 Refrigerant Suction Connection Size On Unit Refrigerant Liquid Connection Size On Unit Recommended Suction and Liquid Line Sizes (O.D.) For Vsrlous Lengtti Runs Lengths up to 30 Feet Lengths 31 to 45 Feet Lengths 46 to 60 Feet Lengths 61 to 90 Feet Lengths 91 to 120 Feet Lengths 121 to 150 Feet Suet. Liq Va" 0 D W 0 D 3 /4" [ D Sweat W I D Sweat IVs" ID. Sweat 3/V'OD Suet. Vs" 0 D 3/4 " 0 D Liq 20''/4"OD Balance s /i6" OD 5 /i6" 10 Sweat 5/16" 0 D 7 /o" 0 D W 25' 5 /i6"od Balance 3/B" OD Suet. 3/d"0D W or^/e" OD See Capacity Multiplier ^"orl'/a" OD See Capacity Multiplier Liq IS'Vi" O.D Balance 5 /i6"0d ffl's/ie" OD Balance VB" OD 0 D 3 /o" I D Sweat 3 /8 " 0 D 1VB"OD IVa'OD 25,3 /e" 0 D Balance 1/2" 0 D 1Ve"OD 20' 3 /8" OD Balance Vs" 0 D Suet. 3/4" OD I 3/4" 0r7/ s"qd See Capacity Multiplier -/B" or I'/s" 0 D See Capacity Multiplier IVB" 0 D Liq 6/16" 0 D 10,5 /i6" OD Balance 3 /8" OD 10'3/a"OD Balance 1 /?" OD Suet. W 0 D Liq. 3/-t" or 7 /a"od See Capacity Multiplier ao's/ib" OD Balance 3 /e"od WorlVs-'OD See Capacity Multiplier 3 /8" 0 D Suet 3/4" 0 D s/vorr/a" QD See Capacity Multiplier Va" or IVs" 0 D. See Capacity Multiplier Liq 60' 5 /i6" O.D Balance 3 /B" 0 D y 3 /8"0D Balance 1 /?" OD Capacity Multiplier For Varying Suction Line Sizes and Length Runs Suction Tubing Size 0 D 30 Ft. Length 60 Ft. Length 90 Ft. Length 120 Ft. Length 5 /8 3 /4 95 Vs 94 91.95 3/-, 94 94 150 Ft Length 94 Factory charge is sufficient for 25 fl. of recdmmended liquid line and matching evaporator For different lengths, adjust charge accordingly V-t" liquid line ±.3 oz. per foot s/ie" liquid line ± 4 oz. per foot 3 /fl" liquid line ± 6 oz. per foot, /2" liquid line ± 1.2 oz. per fool 3 /4.. 3/4 7 /B 1 1 /a 1.01. 95.94 94..93. 92 1 Capacity mulliplier x rated capacity = actual capacity Example -024 with 60' of 3 lt" 0 D Suction Line 24.000 x = 23.520 BTUH 3/4 Vfs 94 92 7 h 1 1 /B 92 V2" 0 D V2" 0 D 7 /B 1 1 /B 13/B 94 93 IVs" 0 D 1 1 /B"OD 1 1 /8 13/8 95 93 91 Approx. s/ie" I D will accept 'A" 0 D held liquid line Requires adapter supplied with unit (packed inside) Table 2 Nominal Tons Vh 2 2 1 /2 3 3 4 5 Horizontal Run 7*" 7," 74" S/l B" 5/lB" 3/8 " 3/8" Liquid Line Sizing (O.D.) Vertical Run %-3/V %-VV' & 20%- 5 /i6" 40%-Vr &60%-s/,6" 20%-74"&%-s/i6" %- 5 /l6" %-s/i6" &20 0 /o- 3 /e" 40%-5/i6" &60%- 3 /e" CD See Table 1 if horizontal run exceeds 30 feet, The smaller size tubing must be at Ifie bottom of the run The combinalion shown wil! result in approximately zero net pressure drop for vertical run Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, and Local codes, regulations, and practices. RHEEM AIR CONDITIONING DIVISION PO Box 17O10, Fort Smith, Arkansas 917 7010 'In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice." PRINTED IN U S A 6-93 BP FORM NO All-149 REV 1 SupGrsedes Form No. All-149 Rev O

Performance Data @ ARI Standard Conditions Cooling Outdoor Unit RAMA- Model Numbers Coil and/or Air Handler Capacity Sensible o FDB/67 o FWB Air 95 0 FDB Outdoor Air Latent Single Phase Three Phase ARI Sound Rating CFIW RCBA-2453+ RXCT-ACA RCBA-2453+ RXCT-ACA {RBEA-14) 19,500 19, 13.001 13, 6,4 6,4 1,757 1,731 RCBA-2453+ RXCT-ACA (RBHA-14) 19, 13, 6,4 1.731 018JA RCGA-24A1 RCGA-24A1 (RBEA-14) 19,500 19, 13,001 13, 6,4 6.4 1.757 1,731 RCGA-24A1 (RBHA-14) RCTB-A024 RCTB-AD24 (RHQA-08) 19. 20.000 20,400 13, 13,400 13, 6,4 6, 6, 1,731 1,747 1,6 13 00 RCAB-A025 2 14,416 6,4 2,048 795 RCAB-A025 {RHQA-08) 2 14,616 6,4 1,928 1 RCAH-Z025 RCBA-2457+ RXCT-ACB 2 22,400 14,2 15,200 6,0 2,029 2,093 5 RCBA-2457+ RXCT-ACB (RBEA-14) 22, RCeA-2457+ RXCT-ACB (RBHA-14) 22, 024JA RCEH-Z025 RC6A-24A2 RCGA-24A2 (RBEA-14) RCGA-24A2 {RBHA-14} 2 22,400 22, " 22, 14,2 15,200 6,0 2,049 2,093 " 5 RCLB-A024 22, 15,504 7,2 2,073 10. RCLB-A024 (RHQA-08) 23,200 15,904 7,2 1,4 11.50 RCPB-C024 RCTB-A024 2 22, 14,416 15,368 6,4 7,232 2.048 2,055 12,00 795 RCTB-A024 (RHQA-08) 23,000 15,8 7,232 1,957 13.00, RCTH-A024 23,000 15,640 7,360 2,081 RCAB-A031 29,000 20,590 8,410 2,673 10.30 RCAH-ZD37 RCBA-3665+ RXCT-ACC 28, 30,000 20,306 21,331 8,294 8.669 2,673 2,691 10 15 RCBA-3665+ RXCT-ACC {RBEA-17) 21,531 RCBA-3665+ RXCT-ACC {RBHA-17) 21,531 RCEH-Z031 29.000 20,590 8,410 2,685 10.25 030JA RCGA-36A1 RCGA-36A1 (RBEA-17} 30,000 21,331 21,531 8.669 2,691 RCGA-36A1 (RBHA-17) 21.531 RCLB-A030 30, 21.6 8,874 2,6 10 85 RCLB-A030(RHGA-13) 30, 21.926 8,874 2,644 11 20 RCPB-C036 20,874 8,526 2,685 10 45 RCTB-A036 30,400 21,584 8,816 2,690 12 15 RCTB-A036(RHQA-13) RCTH-A036 30, 30.400 21,4 21,584 8.816 8,816 2,627 2,690 12 55 12 10 RCAB-A037 RCAH-Z037 33,400 33, 23,714 23,856 9,686 9,744 3,227 3,246 10.10 10.15 RCBA-3673+ RXCT-ACD 35,400 24,6 3,263 RCBA-3673+ RXCT-ACD (RBEA-17) RCBA-3673+ RXCT-ACD {RBHA-17) 35, 35, 25,186 25,186 RCEH-Z037 34,000 24,140 9.860 3,238 10.25 036JA RCGA-36A2 RCGA-36A2 {RBEA-17) RCGA-36A2 {RBHA-17) RCLB-A036 RCLB-A036(RHQA-13) 35,400 35, 35, 35, 36,000 24,6 25.186 25,186 25,418 25,618, 3,263 3,269 3,258 ' 10.85 ' 10.95 RCPB-C036 34,400 24,424 9,6 3,245 (0.40 RCTB-A036 RCTB-A036 (RHQA-13) RCTB-A037 35, 35, 36, 25,418 25,418 25,6 10.614 3,269 3,240 3,283 12,15 12,25 ' RCTB-A037 (RHQA-16) 37,000 26,386 10,614 3,190 12. RCTH-A036 35, 25,2 10,324 3,266 Highest sales volume tested combination required by D 0 E test procedures. Sound rating m accordance with ARI Standard 270 Expansion Valve Kit

(continued) Outdoor Unit RAMA- 042JA [ 048JA V J 060JA Model Numbers RCAB-A049 RCAH-Z049 Coil and/or Air Handler RCBA-48-l- RXCT-ACE RCBA-48-f- RXCT-ACE (RBEA-21) RCBA-48-l- RXCT-ACE (RBHA-21) RCEH-Z049 RCGA-48A1 RCGA-48A1 (RBEA-21) RCGA-48A1 (RBHA-21) RCLB-A048 RCLB-AO-IStRHQA-ie) RCLB-B048 RCLB-B048(RHQA-16) RCMB-A048 RCMB'A048(RHQA-16) RCPB-C042 RCTB-A048 RCTB-A048(RHOA-16) RCTH-A048 RCBA-48+ RXCT-ACE RCBA-48+ RXCT-ACE (RBEA-21) RCBA-48+ RXCT-ACE (RBHA-21) RCGA-48A1 RCGA-48A1 (RBEA-21) RCGA-48A1 (RBHA-21) RCTB-A060 RCTB-A060(RHGA-16). : " 49,000 " RCTB-B060 RCTB-B060(RHQA-16) RCTH-A048(RHQA-16) RCTH-A060 I. RCBA-6089+ RXCT-ACF flcba-60a9-f- RXCT-ACF (RBFA-24) RCBA-6089-l- RXCT-ACF (RBHA-24) RCGA-60A1 RCGA-60A1 {RBEA-21) RCGA-60A1 (RBHA'24) RCQB-B060 RCQB-B060 (RHQA-20) RCQB-C060 RCQB-C060 (RHQA-20) Capacily 39,500 40,000 40,000 44,000 42,500 42,500 42.500 43,000 40,500 42,500 47,000 47,000. 47,000 47,000 47,0.00 Mm 48,500. 48^500 ;. 49,000 49,000 49,00.0 56.000 56.000 Sensible 27,650 28,000 28,000 3 29,750 29,750 29.750 30,250 28,350 29,750 32,6 32,6 32,6 =32,6 32V6 32,6 33,950 :3.4,450 -. 33,950 34,450 34,300 34,300 38,4 38,4 38,4 38,4 38.4 38,4 8D 0 fdb/67 0 FWlB Air 95 0 FDBOuWporAfr Latent 11,850 12,000 0 12, 12, 12,150 12, 12, 1.4,301 14,550 14,550. 14i550 14,550 14,700 14,700 17,2 17,2 1 17,2 17,2 17,2 16, 16, 16. 16, Single Phase. Tola! 3,7 3,828 3,871 3.750 3,750 3,846 3,871 3,750 3.750 3,889 3,793 3,864 3,7 3,864 3,755 3,857 3.871 3,733 3,846 4,352 4,352 4,350 4,261; 4,350 4,261 4,26.1 4,395 5.283 5,283 5,318 5.318 5,318 5,318 10 05 10 10 10 05 10.60 11 35 10 75 1 10 75 1120 10 20 12.20 11 90 12,40 12.30 " 12,75 12.30 12.75 12.75 12.35 Three Phase ;., -'-.-. 1 ARl ; Sound Raling 8.0 7,8 7,8. 7 ;.8.', ' 't;8. 7;8-. cm 1.400 1.400 1,4D0 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1.900 1.900 J,900 Highest sales volume tested combination required by D 0 E lest procedures. Sound rating in accordance with ARl Standard 270 Expansion Valve Kit. Model, No. RAMA-. 018JA 024JA 030JA 036JA 042JA 048JA 060JA Phase Hertz Volts Compr. RLA 9 0/9 0 12 9/12 9 13 5/13 5 18 0/18 0 19 9/19 9 23 7/23 7 28 9/2B 9 Compr. LRA 49 62 5 90 5 107 129 169 ELECTRICAL Faii Motor FLA 8 8 12 1 2 20 20 20 Min. Circuit Ampacity Amps 13/13 16/16 18/18 24/24 26/26 32/32 39/39 fuse oi HACR Circuit Breaker Min. Amps 15/15 20/20 25/25 30/30 35/35 40/40 50/50 Max. Amps 20/20 25/25 30/30 40/40 45/45 50/50 60/60 Face Area Sq. Ft. 15 8 15 8 158 15 8 158 173 20 8 Outdoor Coil Rows 2 2 PHYSICAL CFM 2947 2029 2947 2947 35 3944 35 R22 Oz. 88 85 95 1 192 Het Lbs. 200 184 189 1 201 270 309 Weight Shipping Lbs. 217 201 206 213 218 287 332

Unit Dimensions FIGURE 1 DIMENSIONS t AIR DISCHARGE ALLOW 60" CLEARANCE ACCESS PANEL AIR (NLETS (LOUVERS] ALLOW 12" MIN CLEARANCE 3 SIDES ALLOW 24" ACCESS CLEARANCE SERVICE FITTINGS HIGH VOLTAGE CONNECTION Wa?' LIQUID LINE CONNECTION HIGH PRESSURE CONTROL MANUAL RESET VAPOR LINE CONNECTION 27B" DIA ACCESSORY KNOCKOUTS SERVICE ACCESS TO ELECTRICAL & VALVES ALLOW 24" CLEARANCE ONE SIDE Model Number RAMA- -018/-024/-030-036/-042/-048-060 Height "H" (Inches) 263/4 343A Length "L" (Inches) 429/! B 43 Width "W" (Inches) 31 31 GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Compressor.. Any Other Part.. Ten (10) Years One (1) Year 'For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Factory for a Copy. BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER.