Technical certificate, instruction for installation and use. Sauna heater VIENYBĖ- P K6M ĮST :2003 ГОСТ

Similar documents
SAUNA HEATER INSTALLATION AND OPERATING MANUAL

KALVIS-2-20, 2-25, 2-30, 2-40

User Manual. 60 cm Knob control 4 zone ceramic cooktop

PER-EKO type KSW & KSW PLUS Instruction Manual

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

GECE cm touch control ceramic hob. GECE cm touch control ceramic hob

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

INSTRUCTION MANUAL. UBES60SS2 60cm 4 Solid plate electric hob

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Sauna Heater. Installation and Manual

Installation & Manual. Model T-25

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

Assembly- and User Manual Electric Infrared- Patio Heater MODEL: Geda HS - 2 kw Art. Nr. HS 10000

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100

INSTALLATION AND OPERATING MANUAL

V-ZUG Ltd. Range hood. Mistral/Bora. Operating instructions

V-ZUG Ltd. Range hood. Levante. Operating instructions

User s Manual WS-5830SS WS-5836SS WS-5842SS

INSTRUCTION. for installation and operation of solid fuel fireplace

INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

INSTRUCTIONS AND WARRANTY

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

USER S GUIDE WATER HEATED AIR CURTAINS

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Installation and Operating Instructions. Models: T4-12LOW-9IS

Rocket heater GAMERA

Table of contents. Installation instructions 3 4. Connecting the electric heater to electrical network 4. Control unit 4. Temperature restrictor 4

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Installation and Operating Instructions. Models: T4-12LOW-9IS-1

RANGE HOODS RANGE HOOD INSTALLATION & OPERATIONS MANUAL

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

Technical documentation WATER HEATED AIR CURTAIN MODELS: REVENTON GROUP AERIS 100WN-1P REVENTON GROUP AERIS 150WN-1P REVENTON GROUP AERIS 200WN-1P

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

COOKER HOOD INSTRUCTIONS MANUAL MODEL

Installation and Operating Instructions. Models: T4-13DM-SLI-1 T4-14DM-LOW-1 T4-15DM-CUR-1 T4-18GBOX

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

Operating instructions for the DA 8-2 Extractor

'' Stone Fireplace Model# SRFP41301 Instructions Manual

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Index I. INSTALLATION DIAGRAM... WIRING DIAGRAMS...

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

PELLETS BURNER 15-60kW MOC

INSTRUCTIONS AND WARRANTY

600mm Electric Cooktop with Solid Elements

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

INSTALLATION AND OPERATION MANUAL

Duetto. Electric sauna infrared emitter. Instructions for installation and use. Made in Finland

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

Installation and Operating Instructions

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

TECHNICAL PASSPORT INSTALLATION AND MAINTENANCE MANUAL

60cm Built-In Ceramic Cooktop

GUH90 90 cm Canopy Hood

Andiron / Tipi Burner

Installation and Operating Instructions

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

Conditions for the provision of services Valid from 1 November only for the Jablotron Alarms series of alarms

Electric Cooker. Important Please read these instructions fully before installing or using

GB User and maintenance manual

DESIGN CLASS FUNCTION

OWNERS MANUAL. PLEASE READ THIS MANUAL BEFORE OPERATION

Cat 5 Pro Vacuum OPERATOR S MANUAL

INSTALLATION AND SERVICE INSTRUCTIONS. The biggest Czech producer of fi replace inserts. Accurate and precise design of details

INSTRUCTIONS AND WARRANTY MODEL NO. SI70 STEAM, SPRAY & SURGE/BURST IRON

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Guide to Condition Reports for Domestic Electrical Installations

Warmth, from the heart of J.A. Roby

INSTALLATION INSTRUCTIONS USER GUIDE

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

User and maintenance manual

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

General Care and Safety Guide

INSTRUCTIONS AND WARRANTY

USER MANUAL 9kW LILLY PELLET STOVE

V-ZUG Ltd. Range hood DW-SE/DI-SE. Operating instructions

DXP-PB-2-8 Manual 8 Par-Bake & Form Dough Press

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

INSTRUCTIONS AND WARRANTY MODEL NO. SSI28 STEAM, SPRAY & SURGE/BURST IRON

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

ELX -GN Instructions. Electrolux Front Load Washing Machine Class Action Settlement Claim Form Instructions GENERIC CLAIM FORM

The Morsø S100 Series

Installation and Operating Instructions

Transcription:

EN Technical certificate, instruction for installation and use Sauna heater VIENYBĖ- P K6M ĮST 8271432-33:2003 ГОСТ 9817-95

Certificate of acceptance Sauna heater Vienybė - PK6M Prior to installing and using the sauna heater (hereinafter heater ) make sure to carefully read this manual. This will help you install the product correctly and use it in a most efficient manner as well as prevent possible accidents. When buying the heater familiarize yourself with warranty terms and conditions, check if the acceptance certificate is filled out completely and correctly. Production No. Complies with requirements ГОСТ 9817-95 and ĮST 8271432-33:2003 and ready for use Manufacturing Date TABLE OF CONTENTS Gathered by 1. T echnical parameters... 4 2. Description of the construction... 4 3. Installation... 4 3.1.Fire safety requirements... 5 3.2.Requirements for chimney... 6 4. Handling and maintenance... 6 5. Common failures... 6. Safety requirements... 7 7. Transportation and storage... 7 8. Product components... 8 9. Warranty... 8 Date of purchase 10 3

1. Technical parameters Main technical parameters Fuel used* Total power Coefficient of efficiency, % not less than when firing with wood Diameter of the chimney of the heater Units kw % mm Minimal thrust of the chimney Pa Mouth volume Measurements of the loading hole Measurements (LxBxH) dm 3 mm mm Heated volume when the coefficient of thermal resistance of the building is 2.5, m3 m 3 Consumption of dry wood at nominal capacity** kg/h Weight, not more than kg wood 6 70 Ø150 10 25 231x204 795x504x847 12 20 2, 75 62 *Can also use sawdust briquettes. ** The burning time of the load of fuel depends on the type of fuel, its' calorific capacity, outside temperature and other factors. The heater is designed for home sauna or steam bath heating. 2. Description of the construction The body of the heater is welded from 4, 6 mm steel sheet and covered with protective decorative facing (Pic. 1, pos. 10). A heat resistant ceramic glass (pos. 3) is installed inside the door (pos. 2) of the heater. The glass conducts heat and allows seeing fire. At the bottom of the mouth of the heater there is a cast iron firegrate (pos. 5) and an ashbin (pos. 4) underneath it. The front panel (pos. 1) of the heater may be removed by unscrewing four bolts. It is very convenient when installing the heater. The primary amount of air supplied into the mouth flows through the openings at the bottom of the door. The amount of supplied air may be adjusted with the help of a valve (pos. 9). The heater is painted with heat resistant paint. WARNING! When heating the handle of the door (pos. 2) becomes hot, therefore, wear gloves when opening and closing. To General Manager of AB Umega Application for warranty service I..., have bought a product made by your company ( name, surname or company name) product......, serial No....,... (product name) (date of manufacture) ( date of purchase, place, name of a purchase document and number) After having read the user's manual and product's technical datasheet, I hereby declare that the product is installed in compliance with requirements set in the technical datasheet and is being used in a way it is intended for and in compliance with requirements set in the user's manual. Taking into consideration the foregoing, I have a claim in respect of this product:................ I believe that defects listed in the claim occurred due to imperfection of your product and hereby ask you to send your representatives in order to inspect the connected product, to identify the defects and to rectify them. Should there be determined that the abovementioned defects were caused by improper connection or misuse of the product, or should there be determined that there are no warranty defects, I undertake to reimburse transportation expenses of your representatives (0. 23 / km) and pay for the time spent in the trip and place of inspection ( 8.69 / h) to each service team member (not more than three employees). I agree that the above-mentioned expenses were recovered from me in accordance with the legislation of LR, provided that I do not reimburse them within 7 calendar days. 3.Installation The place where the heater will be installed must have sufficient air supply necessary for combustion and must meet the construction standards and regulations. The heater must be filled with granite stones broken into pieces not larger than 100 mm in diameter; the gap for air circulation must be left (Pic. 1). My address...., telephone.... Name, surname Signature 4 9

8.Product components Sauna heater Vienybė PK 6M 1 unit Technical passport of the heater 1 unit 9.Warranty Manufacturer guarantees that the fireplace complies with ĮST 8271432-33:2003 and ГОСТ 9817-95 requirements provided that transportation, storing, installation and usage requirements were met. A 24-month after purchase warranty is given to the product; a filled out acceptance certificate and a document certifying the purchase must be submitted. For firegrate 6 month warranty. When selling a product a seller must inform a client about the terms and conditions of the warranty, he/she must fill out the acceptance certificate and hand in the user's manual. During the warranty period AB UMEGA is obliged to execute repairs free of charge provided the defects occurred due to the fault of the manufacturer. The warranty shall not be applied if: 1.Documents certifying the purchase are not submitted (VAT invoice, cheque or a cash receipt). 2.The acceptance certificate is lost; 3.The acceptance certificate is not filled out (date of sale is missing, seal of the store is missing, serial number of the heater is missing or differs from the one on the heater); 4.The heater is damaged mechanically; 5.It is determined that the heater was repaired by a third party; 6.The heater was used in a way that is not indicated in the user's manual (inappropriate fuel must not be used); 7.Failure of the heater was caused by faulty installation or connection. 8.Failure was caused by willful changes of the construction; 9.Failure was caused by a natural disaster; 10.Deformations occurred or the metal burned out due to heating at a higher than the nominal rate. 11.The warranty is not applied to the glass of the door; 12.The warranty is not applied to vermiculite bricks; I have Acquainted myself with the terms and conditions of the warranty. Client's surname, signature and date. 3.1. Fire safety requirements Pic.1. VIENYBE- Pk6M 1.Front panel. 2. Door. 3. Glass. 4. Ashbin. 5. Firegrate. 6. Mouth. 9. Air supply valve. 10. Furnishing panels. 11. Stones. 12. Sauna wall. 13. Rockwool S30 50. 14.Fire knife. 15.Bottom fire knife - A400x850 mm metal sheet must be placed on the flammable floor in front of the mouth; - The heater must be connected to the chimney which should meet construction standards and rules and thrust of which is at least 10 Pa. - For the connection of the heater to the chimney steel pipes must be used, thickness of which must be at least 1.5 mm. - The chimney must meet construction standards and regulations. - The installed and connected heater must be approved by a fire safety specialist; - The heater must not be installed on the wooden floor; the floor must have at least 50 mm thick concrete cover with a metal sheet on top. - The heater must be placed only next to the brick wall of the sauna; - The minimum distance between the heater and walls/ceiling of the sauna is shown in Pic. 2 and 3. - The heater must be installed in a way that it would be possible to replace it without breaking down the walls of the sauna, i.e. the distance between the back of the heater and the wall must be at least 300 mm., the duct of the mouth must pass through the opening in the wall freely after the front panel of the door is removed; - The duct of the mouth of the heater must have at least 30 mm thick rock wool insulation; - Wooden ceiling must have at least 50 mm thick layer of rock wool insulation which must be covered with a sheet of galvanized steel or aluminum (see Pic. 3). 8 5

Brick wall Front shield 3 pieš. Akmens Rock wool vata Galvanized Cinkuotos skardos steel or aluminum arba aliuminio sheet lakštas Rockwol 300 Throughout Visu perimetru the perimeter Metal sheet Metalinis Metal lakštas sheet Concrete Betoninis foundation pagrindas 3. 2.Requirements for chimney Pic. 2. Рi с. 3. - - The chimney, the flue and the air ducts should meet construction standards and rules. The inlet into the chimney must be as short as possible and must be directed upwards. The total length of the inlet must not exceed 2 m. The pipe must be secured in place with the help of a clamp; - The diameter of the chimney must be at least 150 mm; - This opening must be free of any other additional connections working contemporaneously; - If the chimney is connected with an additional bend, it's diameter must be at least as the diameter of the chimney of the heater; - Connection points and inlets into the chimney must be sealed properly. 4.Handling and maintenance Only adults who have acquainted themselves with the construction and user's manual of this heater may use it and perform maintenance works. When the heater is fired up for the first time, volatile materials having unpleasant smell are released, this is caused by heating paint. When this happens the room must be ventilated well. After the first heating the paint of the heater will solidify completely. In order to maintain the highest efficiency of the heater the chimney flue and the inner surfaces should be cleaned periodically. The time intervals between the cleaning of the heater depend on the quality of fuel (especially humidity), heating intensity, thrust of the chimney and other factors. It is recommended to clean the heater once or twice per year. When cleaning the accumulated ash and smut is removed. The surface and the glass shall be cleaned only when the heater is cold. A dry cloth shall be used for this. Common synthetic cleaners may be used to clean glass. Make sure the firegrate is clean; do not let the ashbin to become overfilled. 5.Common failures Due to improper cleaning the paint wears out and abrasion marks are seen on the glass. Cracked vermiculite bricks. New bricks may be ordered from the manufacturer of the heater. Broken door, cracked glass. Replacement and fitting of the door is a complex task, the same is true for replacement of glass. Therefore, it should performed by professionals. A replacement glass may be ordered from the manufacturer of the heater. 6.Safety requirements You shall not: - Dry fuel or other flammable materials near or on the heater; - Use flammable liquids (such as petrol, kerosene etc.) to fire up the heater; - Leave doors and covers open when firing the heater; - Touch the glass of the door or the upper part of the furnishing with bare hands when the heater is hot; - Spill ash and cinder near inhabited places; - Leave the attendance of the heater for children. 7.Transportation and storage The heater may be transported with the help of any kind of transport with a cover, when transporting, the heater must maintain vertical position. When the weather is dry the heater may be transported uncovered. Safeguards shall be used to prevent falling or scratching during transportation. Do not hit, tumble or drop the heater when loading/unloading. The heaters shall be stored in a dry place free of vapors of chemically active substances. NOTE: If the supply agreement does not provide otherwise, the heaters shall be stored and transported secured on a wooden pallet and wrapped in a polyethylene film. 6 7