Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Similar documents
Acoustical Surfaces, Inc.

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Report of Surface Burning Characteristics Test on Acoustical Panel

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

We Identify and S.T.O.P. Your Noise Problems

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

SIGMADEK, LTD. FIRE TEST REPORT

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

FUNDERMAX GMBH FIRE TEST REPORT

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

Public Comment No. 2-NFPA [ Section No ]

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

Report on Public Input June 2014 NFPA 101

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

File E Project 97SC January 21, 1998 REPORT

F, T, L and W Ratings - What are the Code & Testing Requirements?

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Materials Testing by Gregory Havel

SOUTHWEST RESEARCH INSTITUTE

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

BCTC CARPET TECHNICAL CENTRE

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Public Comment No. 1-NFPA [ Section No ]

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Classification of Fire Performance of Wall and Ceiling Lining Materials

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

First Revision No. 6-NFPA [ Section No. 2.2 ]

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

Fire Performance of Translucent Systems

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

FACADES AND FIRE The Essential Elements

CEPE guidance to a quality control fire test regime for intumescent coatings Date of issue: 24 May 2011

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

PART 1 GENERAL 1.01 SUMMARY

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

NF X : Parts 1, 2, 3, 4 & 5

CERTIFICATION BULLETIN

J-PRO TM Cable Support System

CERTIFICATE OF COMPLIANCE

Heat and Smoke Release of a Ceiling-Installed Speaker

2.2 Factors in design

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Saving lives with coatings

PART 1 GENERAL 1.01 SUMMARY

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Transcription:

February, 11 Revised February 28, 11 Jotun UAE Ltd (LLC) Mr. Richard Mann Al Quozind District Dubai, 3671 UAE Our Reference: Subject: SV18666/11CA24 Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC) Dear Mr. Mann: This is a Report summarizing the results of tests conducted under the Commercial Inspection and Testing Services (CITS) program identified as Assignment No. 11CA24. GENERAL: The results relate only to items tested. METHOD: Each test was conducted in accordance with Standard ANSI/UL723, Tenth Edition, dated September, 8, "Test for Surface Burning Characteristics of Building Materials", (ASTM E84-). The test determines the Surface Burning Characteristics of the material, specifically the flame spread and smoke developed indices when exposed to fire. The maximum distance the flame travels along the length of the sample from the end of the igniting flame is determined by observation. The Flame Spread Index of the material is derived by plotting the progression of the flame front on a time-distance basis, ignoring any flame front recession, and using the equations described below: A. CFS =.515 A T when A T is less than or equal to 97.5 minute-foot. B. CFS = 49/ (195-A T ) when A T is greater than 97.5 minute-foot. Where A T = total area under the time distance curve expressed in minute-foot. The Smoke Developed Index (SDI) is determined by rounding the Calculated Smoke Developed (CSD) as described in UL 723. The CSD is determined by the output of photoelectric equipment operating across the furnace flue pipe. A curve is developed by plotting the values of light absorption (decrease in cell output) against time. The CSD is derived by expressing the net area under the curve for the material tested as a percentage of the area under the curve for untreated red oak.

The CSD is expressed as: CSD = (A m /A ro ) x Where: CSD = Calculated Smoke Developed A m = the area under the curve for the test material. A ro = the area under the curve for untreated red oak. SAMPLES: The samples utilized in this investigation were neither prepared nor selected by a Laboratories' representative such that no verification of composition can be provided. Test No. Sample Description System 1 Penguard Express ZP at 1 x 125 Microns Steelmaster 6 / 1 at 2x 3 microns DFT Waterfine Top coat at 2 x 6 Microns DFT coating on steel substrate 2 Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 35 microns DFT intumescent intumescent coating on steel substrate Due to the rigidity of the test samples, supplementary means of support was not required. RESULTS: The results are tabulated below are considered applicable only to the specific samples tested. Data sheets and graphical plots of flame travel versus time and smoke developed versus time are also enclosed. Table 1: Test Summary Test No. Test Code Sample Description 1 91116 2 91117 CFS Calculated Flame Spread FSI Flame Spread Index CSD Calculated Smoke Developed SDI Smoke Developed Index Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 3 microns DFT Waterfine Top coat at 2 x 6 Microns DFT intumescent coating on steel substrate 4.31 5 11.9 Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 35 microns DFT intumescent coating on steel substrate 14.4 15 69.8 7

The Classification Marking of Underwriters Laboratories Inc. on the product is the only method provided by Underwriters Laboratories Inc. to identify products which have been produced under its Classification and Follow-Up Service. No use of a Classification Marking has been authorized as a result of this investigation. Since the anticipated work has been completed, we have instructed our Accounting Department to terminate the investigation and invoice you for the charges incurred to date. Should you have any questions, please contact the undersigned. Very truly yours Reviewed by: Jamila Shawon (ext. 4267) James Smith (ext. 42666) Project Engineer Staff Engineering Associate Fire Protection Division Fire Protection Division

Project: 11CA24 File: SV18666 TestCode: 91116 Tested by: SCOTT KNIGHTON Engineer: JAMILA SHAWON Date: 11-2-9 TEST METHOD: The test was conducted in accordance with UL 723, Tenth Edition. Client Name: JOTUN UAE LTD (LLC) Test Duration minutes Test No.: 1 Hot Test: No Mounting: Self Test Type: CITS Burn-Out Required: No Test Sample: Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 3 microns DFT Waterfine Top coat at 2 x 6 Microns DFT intumescent coating on steel substrate FLAME SPREAD RESULTS Flame Spread Data Distance (Feet) Ignition 68.5 98 1 128 Time (Sec) Calculated Flame Spread (CFS): 4.31 Flame Spread Index (FSI): 5 Time to Ignition (sec): 68 Maximum Flame Spread (ft): 1. Area Under the Flame Spread Curve (ft.-min): 8.4 SMOKE RESULTS Calculated Smoke Developed (CSD): 11.9 Smoke Developed Index (SDI): Area Under the Smoke Curve (Obs-min.): 8.84 Area Under Red Oak Curve (Obs-min.): 74.7 Post-Test Observations Discoloration (Feet From Burner): 24 Melt (Feet From Burner): 9.5 Char (Feet From Burner): 5 ULS-723-BIKT-DataSheet-1 Form Issued: 4-1-28 Form Page 4 Form Revised: 7-15- Form Copyright 7 Underwriters Laboratories Inc. Only those products bearing the UL mark should be considered as being covered by UL

Obscuration (%) Flame Spread (feet) Flame Spread / Smoke Results JOTUN UAE LTD (LLC) Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 3 microns DFT Waterfine Top coat at 2 x 6 Microns DFT intumescent coating on steel substrate 9 8 7 6 5 4 3 % Obscuration Flame Spread 2 4 6 8 Time (Minutes) 18 16 14 12 8 6 4 2 Test Num.: 1 Flame Spread Index: 5 SV18666 / 11CA24 Smoke Developed Index: 91116 Max. Flame Spread (ft.): 1.

Project: 11CA24 File: SV18666 TestCode: 91117 Tested by: SCOTT KNIGHTON Engineer: JAMILA SHAWON Date: 11-2-9 TEST METHOD: The test was conducted in accordance with UL 723, Tenth Edition. Client Name: JOTUN UAE LTD (LLC) Test Duration minutes Test No.: 2 Hot Test: No Mounting: Self Test Type: CITS Burn-Out Required: No Test Sample: Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 35 microns DFT intumescent coating on steel substrate FLAME SPREAD RESULTS Flame Spread Data Distance (Feet) Ignition 46.5 98 1 1 1.5 126 2 14 2.5 15 3 176 3.5 188 Time (Sec) Calculated Flame Spread (CFS): 14.4 Flame Spread Index (FSI): 15 Time to Ignition (sec): 46 Maximum Flame Spread (ft): 3.5 Area Under the Flame Spread Curve (ft.-min): 27.3 SMOKE RESULTS Calculated Smoke Developed (CSD): 69.8 Smoke Developed Index (SDI): 7 Area Under the Smoke Curve (Obs-min.): 51.68 Area Under Red Oak Curve (Obs-min.): 74.7 Post-Test Observations Discoloration (Feet From Burner): 24 Melt (Feet From Burner): 18 Char (Feet From Burner): 5 ULS-723-BIKT-DataSheet-1 Form Issued: 4-1-28 Form Page 6 Form Revised: 7-15- Form Copyright 7 Underwriters Laboratories Inc. Only those products bearing the UL mark should be considered as being covered by UL

Obscuration (%) Flame Spread (feet) Flame Spread / Smoke Results JOTUN UAE LTD (LLC) Penguard Express ZP at 1 x 125 Microns DFT Steelmaster 6 / 1 at 2x 35 microns DFT intumescent coating on steel substrate 9 8 7 6 5 4 3 % Obscuration Flame Spread 2 4 6 8 Time (Minutes) 18 16 14 12 8 6 4 2 Test Num.: 2 Flame Spread Index: 15 SV18666 / 11CA24 Smoke Developed Index: 7 91117 Max. Flame Spread (ft.): 3.5